Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 118
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37294671

RESUMO

AIMS: To define a stepwise application of left bundle branch pacing (LBBP) criteria that will simplify implantation and guarantee electrical resynchronization. Left bundle branch pacing has emerged as an alternative to biventricular pacing. However, a systematic stepwise criterion to ensure electrical resynchronization is lacking. METHODS AND RESULTS: A cohort of 24 patients from the LEVEL-AT trial (NCT04054895) who received LBBP and had electrocardiographic imaging (ECGI) at 45 days post-implant were included. The usefulness of ECG- and electrogram-based criteria to predict accurate electrical resynchronization with LBBP were analyzed. A two-step approach was developed. The gold standard used to confirm resynchronization was the change in ventricular activation pattern and shortening in left ventricular activation time, assessed by ECGI. Twenty-two (91.6%) patients showed electrical resynchronization on ECGI. All patients fulfilled pre-screwing requisites: lead in septal position in left-oblique projection and W paced morphology in V1. In the first step, presence of either right bundle branch conduction delay pattern (qR or rSR in V1) or left bundle branch capture Plus (QRS ≤120 ms) resulted in 95% sensitivity and 100% specificity to predict LBBP resynchronization, with an accuracy of 95.8%. In the second step, the presence of selective capture (100% specificity, only 41% sensitivity) or a spike-R <80 ms in non-selective capture (100% specificity, sensitivity 46%) ensured 100% accuracy to predict resynchronization with LBBP. CONCLUSION: Stepwise application of ECG and electrogram criteria may provide an accurate assessment of electrical resynchronization with LBBP (Graphical abstract).


Assuntos
Fascículo Atrioventricular , Terapia de Ressincronização Cardíaca , Humanos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco , Resultado do Tratamento
2.
Ann Dermatol Venereol ; 146(10): 634-639, 2019 Oct.
Artigo em Francês | MEDLINE | ID: mdl-31122751

RESUMO

BACKGROUND: Anti-PD-1 and anti-CTLA-4 monoclonal antibodies are used in melanoma, while anti-PD-1 are also used in Hodgkin's lymphoma. Primary central nervous system lymphoma is a rare form of non-Hodgkin's lymphoma with few effective treatments. However, several recent studies have reported multiple cases of non-Hodgkin's lymphoma and primary central nervous system lymphoma treated by anti-PD-1 antibodies with favourable responses. PATIENTS AND METHODS: This study focuses on the case of a 59-year-old man with metastatic melanoma treated by immunotherapy (anti-CTLA-4 followed by anti-PD-1). He underwent 28 courses of therapy with pembrolizumab. Treatment was stopped after clinical and radiological remission. The patient presented left hemiparesis and a primary central nervous system lymphoma was diagnosed two months after discontinuation of immunotherapy. He started urgent high-dose methotrexate chemotherapy but without significant results. Despite second-line chemotherapy with R-ICE (rituximab-ifosfamide, carboplatin and etoposide), the patient died. DISCUSSION: Several hypotheses may be advanced regarding a possible relationship between immunotherapy and the occurrence of this primary central nervous system lymphoma. The lymphoma may have been pre-existing and controlled by immunotherapy, but progressing rapidly after treatment, or it may have been induced by the immunotherapy. However, immunotherapy may have played no role; the relationship between melanoma and lymphoma is well known. CONCLUSION: While immunotherapy cannot be unequivocally incriminated in primary central nervous system lymphoma, this case raises many questions about the imputability of immunotherapy in the occurrence of secondary cancers, including lymphomas.


Assuntos
Anticorpos Monoclonais Humanizados/uso terapêutico , Antineoplásicos Imunológicos/uso terapêutico , Neoplasias Encefálicas/patologia , Linfoma Difuso de Grandes Células B/patologia , Melanoma/tratamento farmacológico , Neoplasias Encefálicas/diagnóstico por imagem , Evolução Fatal , Humanos , Linfoma Difuso de Grandes Células B/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Paresia/etiologia , Neoplasias Cutâneas/tratamento farmacológico
3.
Transpl Infect Dis ; 20(4): e12894, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29603514

RESUMO

INTRODUCTION: While the growing knowledge on HIV among solid organ transplant recipients (SOT) is limited to either pretransplant infection or allograft transmission, there are only sparse reports describing HIV-infection after transplantation through sexual route, the primary mode of transmission in the general population. METHODS: From two different centers, we report nine new cases of HIV infection in SOT recipients attributed to sexual acquisition: eight cases of kidney-transplant recipients and one heart-transplant recipient. FINDINGS: There were nine cases of post-transplant HIV-infection detected among 14 526 transplants performed 1998 to 2015. In 6/9 cases, infection was contracted 5 years after SOT. All but one patient had stable allograft function under immunosuppressive therapy. The main trigger to diagnosis was late CMV disease and sexually transmitted diseases; five patients had CDC-stage 3 HIV infection. In 7/9 patients, virologic response and CD4 recovery were achieved within 3 months after starting antiretroviral therapy (ART). After an average of 3.6 years post diagnosis, 5/9 patients remained alive with well-controlled infection and functioning allograft. CONCLUSION: Sexual acquisition of HIV infection after SOT represents a difficult challenge, as it may occur in any kind of transplant and at any time. The course of infection resembles that of the general population, with life-threatening infectious complications, but good response to ART. Assessment of lifestyle and risk behavior is paramount, as indications may be not disclosed without direct questioning.


Assuntos
Antivirais/uso terapêutico , Infecções por HIV/epidemiologia , Transplante de Coração/efeitos adversos , Transplante de Rim/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Adulto , Feminino , Seguimentos , Rejeição de Enxerto/prevenção & controle , HIV/efeitos dos fármacos , HIV/isolamento & purificação , Infecções por HIV/tratamento farmacológico , Infecções por HIV/virologia , Comportamentos de Risco à Saúde , Humanos , Imunossupressores/uso terapêutico , Estilo de Vida , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/tratamento farmacológico , Complicações Pós-Operatórias/virologia , Resposta Viral Sustentada
6.
Am J Transplant ; 16(1): 21-8, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26523614

RESUMO

Cardiovascular diseases have become a significant cause of morbidity in patients with human immunodeficiency virus (HIV) infection. Heart transplantation (HT) is a well-established treatment of end-stage heart failure (ESHF) and is performed in selected HIV-infected patients in developed countries. Few data are available on the prognosis of HIV-infected patients undergoing HT in the era of combined antiretroviral therapy (cART) because current evidence is limited to small retrospective cohorts, case series, and case reports. Many HT centers consider HIV infection to be a contraindication for HT; however, in the era of cART, HT recipients with HIV infection seem to achieve satisfactory outcomes without developing HIV-related events. Consequently, selected HIV-infected patients with ESHF who are taking effective cART should be considered candidates for HT. The present review provides epidemiological data on ESHF in HIV-infected patients from all published experience on HT in HIV-infected patients since the beginning of the epidemic. The practical management of these patients is discussed, with emphasis on the challenging issues that must be addressed in the pretransplant (including HIV criteria) and posttransplant periods. Finally, proposals are made for future management and research priorities.


Assuntos
Terapia Antirretroviral de Alta Atividade/efeitos adversos , Infecções por HIV/complicações , Insuficiência Cardíaca/cirurgia , Transplante de Coração , Infecções por HIV/tratamento farmacológico , Insuficiência Cardíaca/induzido quimicamente , Humanos , Prognóstico
7.
Europace ; 18(2): 232-7, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25883077

RESUMO

AIMS: Matrix metalloproteinases (MMPs) and their tissue inhibitors (TIMPs) are involved in cardiac remodelling. Available information regarding their prognostic utility in heart failure (HF) and cardiac resynchronization therapy (CRT) is controversial. The aim of this study was to analyse MMP-2 and TIMP-1 levels as predictors of long-term mortality in HF patients treated with CRT. METHODS AND RESULTS: We prospectively included 42 consecutive patients with successfully implanted CRT. Matrix metalloproteinase-2 and TIMP-1 assays were performed prior to implant. Patients were evaluated at baseline and at the outpatient clinic at 6-month intervals. Clinical response, left ventricular (LV) remodelling, and mortality were analysed. During a mean follow-up of 60 ± 34 months, long-term mortality from any cause was 36% (15 patients). The cause of death was end stage of HF in 12 patients, sudden death in 2 patients, and 1 unknown. After adjustment using a Cox regression model, the independent predictors of long-term mortality were baseline TIMP-1, hazard ratio (HR) 1.18 (95% confidence interval (95% CI) [1.05-1.33], P = 0.007), baseline glomerular filtration rate (GFR), HR 0.97 (95% CI [0.94-1.00], P = 0.05), and permanent atrial fibrillation (AF), HR 3.14 (95% CI [1.02-9.67], P = 0.04). Area under receiver operating characteristic curve for TIMP-1 was 0.79 (95% CI [0.63-0.94]). Tissue inhibitor of matrix metalloproteinase-1 ≥ 248 ng/mL predicts mortality with 80% sensitivity and 71% specificity. CONCLUSION: Tissue inhibitor of matrix metalloproteinase-1 is a powerful predictor of long-term mortality in HF patients treated with CRT.


Assuntos
Terapia de Ressincronização Cardíaca/mortalidade , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Inibidor Tecidual de Metaloproteinase-1/sangue , Função Ventricular Esquerda , Remodelação Ventricular , Idoso , Área Sob a Curva , Biomarcadores/sangue , Terapia de Ressincronização Cardíaca/efeitos adversos , Causas de Morte , Intervalo Livre de Doença , Feminino , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/fisiopatologia , Transplante de Coração , Humanos , Estimativa de Kaplan-Meier , Masculino , Metaloproteinase 2 da Matriz/sangue , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Prospectivos , Curva ROC , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
9.
Europace ; 16(9): 1342-9, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24576973

RESUMO

AIMS: Patients with heart failure (HF) as well as atrial fibrillation (AF) have suboptimal response to cardiac resynchronization therapy (CRT). Identification of mechanical abnormalities, amenable to correction with CRT, might improve the selection of candidates and CRT efficiency. We evaluated whether abnormal septal motion, assessed by the presence of septal flash (SF) is related to CRT response in patients with AF. METHODS AND RESULTS: Ninety-four CRT patients with AF were included. Echocardiography was performed in all subjects at baseline and at 12-month follow-up. Abnormal septal motion was defined by the presence of SF (early septal inward/outward motion within the isovolumic contraction period/QRS duration). Response to CRT was defined as a reduction (>15%) of the end-systolic volume of the left ventricle (LV). Univariate and multivariate analyses were performed to identify the predictors of CRT response. The mean age was 69 ± 8 years, 79% were males, and 59% of patients responded to CRT. Cardiovascular death was 14.4% and all-cause mortality was 16.5% during follow-up. Patients with SF at baseline that was acutely corrected by CRT were significantly more likely to respond than patients without SF. Baseline SF was an independent predictor of CRT response (OR 5.24; 95% CI 1.95-14.11). CONCLUSION: Abnormal septal motion, assessed by the presence of SF, is a mechanism amenable to CRT correction. Its correction is associated with a higher likelihood of CRT response in HF patients with long-standing AF. This could improve the selection of candidates to CRT in a subgroup with particularly poor response and long-term prognosis.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Terapia de Ressincronização Cardíaca/métodos , Septos Cardíacos/diagnóstico por imagem , Idoso , Doença Crônica , Feminino , Seguimentos , Humanos , Masculino , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento , Ultrassonografia
10.
Transpl Infect Dis ; 16(4): 631-3, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24903646

RESUMO

Toxoplasma gondii is an opportunistic pathogen that causes neurologic and extraneurologic manifestations in immunosuppressed patients. Encephalitis and intracranial mass lesions are easily recognized as typical manifestations of toxoplasmosis. However, meningitis caused by T. gondii is a rare condition with very few cases described in the literature. We present the case of a heart transplant recipient who developed toxoplasmic encephalitis associated with meningitis. After an extensive review of the medical literature, we found only 1 case of meningitis in solid organ transplant recipients and <25 cases in immunosuppressed patients, such as patients infected with human immunodeficiency virus or those with Hodgkin's disease. In this report, we consider toxoplasmosis in the differential diagnosis of meningitis in immunocompromised individuals.


Assuntos
Encefalite/parasitologia , Transplante de Coração/efeitos adversos , Meningite/parasitologia , Toxoplasmose Cerebral/etiologia , Antiprotozoários/administração & dosagem , Antiprotozoários/uso terapêutico , Clindamicina/administração & dosagem , Clindamicina/uso terapêutico , Quimioterapia Combinada , Humanos , Masculino , Meningite/complicações , Pessoa de Meia-Idade , Inibidores da Síntese de Proteínas/administração & dosagem , Inibidores da Síntese de Proteínas/uso terapêutico , Pirimetamina/administração & dosagem , Pirimetamina/uso terapêutico , Toxoplasmose Cerebral/parasitologia
11.
Heart Rhythm ; 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38906515

RESUMO

BACKGROUND: Left bundle branch pacing (LBBP) is considered an alternative to cardiac resynchronization therapy (CRT). However, LBBP is not suitable for all patients with heart failure. OBJECTIVE: The aim of our study was to identify predictors of unsuccessful LBBP implantation in CRT candidates. METHODS: A cohort of consecutive patients with indications for CRT were included. Clinical, echocardiographic, and electrocardiographic variables were prospectively recorded. RESULTS: A total of 187 patients were included in the analysis. LBBP implantation was successful in 152 of 187 patients (81.2%) and failed in 35 of 187 patients (18.7%). The causes of unsuccessful implantation were unsatisfactory paced QRS morphology (28 of 35 [80%]), inability to screw the helix (4 of 35 [11.4%]), lead instability (2 of 35 [5.7%]), and high pacing thresholds (1 of 35 [2.8%]). The left ventricular end-diastolic diameter (LVEDD), non-LBBB (left bundle branch block) QRS morphology, and QRS width were predictors of failed implantation according to the univariate analysis. According to the multivariate regression analysis, LVEDD (odds ratio 1.31 per 5-mm increase; 95% confidence interval 1.05-1.63 per 5-mm increase; P = .02) and non-LBBB (odds ratio 3.07; 95% confidence interval 1.08-8.72; P = .03) were found to be independent predictors of unsuccessful LBBP implantation. An LVEDD of 60 mm has 60% sensitivity and 71% specificity for predicting LBBP implant failure. CONCLUSION: When LBBP was used as CRT, LVEDD and non-LBBB QRS morphology predicted unsuccessful implantation. Non-LBBB triples the likelihood of failed implantation independent of LVEDD. Caution should be taken when considering these parameters to plan the best pacing strategy for patients.

12.
Eur Heart J Cardiovasc Imaging ; 25(10): 1394-1404, 2024 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-38768299

RESUMO

AIMS: Longitudinal dyssynchrony correction and 'strain' improvement by comparable cardiac resynchronization therapy (CRT) techniques is unreported. Our purpose was to compare echocardiographic dyssynchrony correction and 'strain' improvement by conduction system pacing (CSP) vs. biventricular pacing (BiVP) as a marker of contractility improvement during 1-year follow-up. METHODS AND RESULTS: A treatment-received analysis was performed in patients included in the LEVEL-AT trial (NCT04054895), randomized to CSP or BiVP, and evaluated at baseline (ON and OFF programming) and at 6 and 12 months (n = 69, 32% women). Analysis included intraventricular (septal flash), interventricular (difference between left and right ventricular outflow times), and atrioventricular (diastolic filling time) dyssynchrony and 'strain' parameters [septal rebound, global longitudinal 'strain' (GLS), LBBB pattern, and mechanical dispersion). Baseline left ventricular ejection fraction (LVEF) was 27.5 ± 7%, and LV end-systolic volume (LVESV) was 138 ± 77 mL, without differences between groups. Longitudinal analysis showed LVEF and LVESV improvement (P < 0.001), without between-group differences. At 12-month follow-up, adjusted mean LVEF was 46% with CSP (95% CI 42.2 and 49.3%) vs. 43% with BiVP (95% CI 39.6 and 45.8%), (P = 0.31), and LVESV was 80 mL (95% CI 55.3 and 104.5 mL) vs. 100 mL (95% CI 78.7 and 121.6 mL), respectively (P = 0.66). Longitudinal analysis showed a significant improvement of all dyssynchrony parameters and GLS over time (P < 0.001), without differences between groups. Baseline GLS significantly correlated with LVEF and LVESV at 12-month follow-up. CONCLUSION: CSP and BiVP provided similar dyssynchrony and 'strain' correction over time. Baseline global longitudinal 'strain' predicted ventricular remodelling at 12-month follow-up.


Assuntos
Terapia de Ressincronização Cardíaca , Humanos , Feminino , Masculino , Terapia de Ressincronização Cardíaca/métodos , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Ecocardiografia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/diagnóstico por imagem , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/terapia , Disfunção Ventricular Esquerda/fisiopatologia , Estudos Longitudinais , Seguimentos
13.
J Card Fail ; 19(2): 80-6, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23384632

RESUMO

BACKGROUND: The aim of this study was to assess the presence of evidence of ventricular mechanical dyssynchrony in patients with isolated left ventricular noncompaction cardiomyopathy (IVNC) and the potential usefulness of cardiac resynchronization therapy (CRT) in those patients. METHODS AND RESULTS: We studied 25 patients consecutively diagnosed with IVNC and a control group of 50 patients with dilated cardiomyopathy of different etiologies. Mechanical dyssynchrony was assessed by echocardiography by the presence of a septal flash, the time from peak septal to posterior wall displacement, and the time from septal to lateral wall peak systolic velocity. Among the patients with IVNC, 9 received CRT and were followed at 12 months. Overall, dyssynchrony parameters were significantly more frequent in IVNC, regardless of QRS duration. All 9 IVNC patients treated with CRT showed a septal flash, and a favorable response was observed in 8/9 patients (89%) regardless of QRS width. CONCLUSIONS: The presence of mechanical dyssynchrony, amenable to correction with CRT, is common in patients with IVNC, independently from QRS width. This might be related to altered electrical endocardial activation associated with abnormal myocardium and could be the justification for the high response rate to CRT observed in these patients.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Cardiomiopatia Dilatada/fisiopatologia , Cardiomiopatia Dilatada/terapia , Adulto , Idoso , Fenômenos Biomecânicos/fisiologia , Terapia de Ressincronização Cardíaca/tendências , Cardiomiopatia Dilatada/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
14.
JACC Clin Electrophysiol ; 8(11): 1431-1445, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36424012

RESUMO

BACKGROUND: Conduction system pacing (CSP) has emerged as an alternative to biventricular pacing (BiVP). Randomized studies comparing both therapies are scarce and do not include left bundle branch pacing. OBJECTIVES: This study aims to compare ventricular resynchronization achieved by CSP vs BiVP in patients with cardiac resynchronization therapy indication. METHODS: LEVEL-AT (Left Ventricular Activation Time Shortening with Conduction System Pacing vs Biventricular Resynchronization Therapy) was a randomized, parallel, controlled, noninferiority trial. Seventy patients with cardiac resynchronization therapy indication were randomized 1:1 to BiVP or CSP, and followed up for 6 months. Crossover was allowed when primary allocation procedure failed. Primary endpoint was the change in left ventricular activation time, measured using electrocardiographic imaging. Secondary endpoints were left ventricular reverse remodeling and the combined endpoint of heart failure hospitalization or death at 6-month follow-up. RESULTS: Thirty-five patients were allocated to each group. Eight (23%) patients crossed over from CSP to BiVP; 2 patients (6%) crossed over from BiVP to CSP. Electrocardiographic imaging could not be performed in 2 patients in each group. A similar decrease in left ventricular activation time was achieved by CSP and BiVP (-28 ± 26 ms vs -21 ± 20 ms, respectively; mean difference -6.8 ms; 95% CI: -18.3 ms to 4.6 ms; P < 0.001 for noninferiority). Both groups showed a similar change in left ventricular end-systolic volume (-37 ± 59 mL CSP vs -30 ± 41 mL BiVP; mean difference: -8 mL; 95% CI: -33 mL to 17 mL; P = 0.04 for noninferiority) and similar rates of mortality or heart failure hospitalizations (2.9% vs 11.4%, respectively) (P = 0.002 for noninferiority). CONCLUSIONS: Similar degrees of cardiac resynchronization, ventricular reverse remodeling, and clinical outcomes were attained by CSP as compared to BiVP. CSP could be a feasible alternative to BiVP. (LEVEL-AT [Left Ventricular Activation Time Shortening With Conduction System Pacing vs Biventricular Resynchronization Therapy]; NCT04054895).


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Sistema de Condução Cardíaco , Bloqueio de Ramo , Doença do Sistema de Condução Cardíaco/terapia , Remodelação Ventricular
15.
Transplant Proc ; 51(10): 3424-3427, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31810509

RESUMO

BACKGROUND: Pulmonary function tests (PFTs) are often impaired in patients with advanced heart failure. There is limited data about their impact on survival after heart transplantation (HT). We sought to assess the prevalence and type of PFT abnormalities in patients on HT waiting list and their impact on outcomes. METHODS: We performed a retrospective analysis of a prospective registry of consecutive patients undergoing HT between 2012 and 2018. Patients were classified into 4 groups according to pre-HT PFT results: 1. normal pattern: forced vital capacity (FVC) ≥ 80% and forced expiratory volume in 1 second (FEV1) to FVC ratio (FEV1/FVC) ≥ 0.7; 2. obstructive: FEV1/FVC < 0.7; 3. nonobstructive: FEV1/FVC ≥ 0.7 and FVC < 80% when total lung capacity value was not available; and 4. restrictive: FEV1/FVC ≥ 0.7 and total lung capacity < 80%. The prevalence of impaired carbon monoxide diffusing capacity corrected for hemoglobin < 80% and FEV1 < 70% was also analyzed. High-urgency HT patients and those referred from other centers without quantitative pulmonary evaluation were excluded. RESULTS: Among 123 patients who underwent HT, 83 patients with complete PFT were included. Median follow-up was 2.7 ± 1.9 years. Of these, 29 (34.9%) had an obstructive pattern, 20 (24.1%) a nonobstructive, 18 (21.7%) a restrictive, and 16 (19.3%) a normal pattern. Fifty-one (61.4%) patients had FEV1 < 70% and 58 (69.9%) a carbon monoxide diffusing capacity corrected for hemoglobin < 80%. There was a tendency to lower survival in all altered PFT groups compared with normal (P = .054) but not within the other groups. Patients with an impaired FEV1 had significantly higher mortality than patients with normal values (P = .008). Area under receiver operating characteristic curve for FEV1 was 0.73 (95% confidence interval [0.60-0.86]). A cutoff value of FEV1 (60.5) predicts mortality with 66% sensitivity and 64% specificity. CONCLUSIONS: PFT alterations have a very high prevalence on HT waiting list patients. Patients with impaired FEV1 had worse outcomes after heart transplantation.


Assuntos
Insuficiência Cardíaca/complicações , Transplante de Coração , Pneumopatias/complicações , Adulto , Feminino , Transplante de Coração/mortalidade , Humanos , Pulmão/fisiopatologia , Pneumopatias/epidemiologia , Pneumopatias/fisiopatologia , Masculino , Pessoa de Meia-Idade , Prevalência , Curva ROC , Testes de Função Respiratória , Estudos Retrospectivos
16.
Clin Cardiol ; 30(3): 141-3, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17385702

RESUMO

Cardiac resynchronization therapy (CRT) is a new method for the correction of inter- and/or intraventricular conduction delays of patients with heart failure. The long-term impact of CRT on central hemodynamics is not fully characterized. We performed complete right heart catheterization studies in 31 patients receiving a CRT device pre and 6 months after implantation. Most of the patients improved in their NYHA stage, their LVEF, and in parallel showed reduced right atrial (RA) pulmonary artery (PA) and pulmonary capillary wedge (PCW) pressures and pulmonary vascular resistance both at rest and at 25 watts. In addition, we found a reduction in heart rate accompanied by an increased mean arterial pressure both at rest and at 25 watts. Accordingly, brain natriuretic peptide levels (BNP) were lowered. It was concluded that, besides other well-known effects on ventricular coordination, central hemodynamics after 6 months were improved during CRT.


Assuntos
Estimulação Cardíaca Artificial , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Adulto , Biomarcadores/sangue , Cateterismo Cardíaco , Doença da Artéria Coronariana/complicações , Estimulação Elétrica , Feminino , Seguimentos , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/etiologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Marca-Passo Artificial , Pressão Propulsora Pulmonar , Volume Sistólico , Resultado do Tratamento , Resistência Vascular , Pressão Ventricular
17.
Carbohydr Polym ; 172: 142-151, 2017 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-28606520

RESUMO

Polyelectrolyte complexes (PECs) based on Alginate and Chitosan were prepared for biomedical application. These two biopolymers are valuable resources for biomedical applications. In the present work, three PECs materials were produced using three different drying techniques: hot air drying, lyophilization and supercritical CO2 drying. The choice of the drying technique allowed producing different type of structures, with different porosity scale. In order to evaluate their potential as intra-abdominal wound dressings, swelling ability in various media, enzymatic resistance and drug release behavior of the resulting materials was studied. It was shown that the increase of the porosity improved the swelling ability, without altering the resistance of the materials, whereas drug release studies revealed that the majority of the drug was released within the first 24h whatever the drying process.

19.
Artigo em Inglês | MEDLINE | ID: mdl-16547655

RESUMO

INTRODUCTION: Cardiac resynchronization therapy (CRT) using coronary sinus (CS) leads is a new method for the therapy of congestive heart failure (CHF). Because the intervention is more complex than regular pacemaker implantations, information on the feasibility and side effects of this method are of interest. METHODS: From 1999 to June 2005, CRT implantations were attempted in 244 patients (pts; mean age 64+/-12 years, range 14-90 years), 82% were male, 44% had coronary artery disease, 29% were in atrial fibrillation, 71 had preexisting pacemakers. RESULTS: In 97% of the pts the intervention was successful (27% of the systems with defibrillation capabilities). In 285 interventions, 255 CS leads were positioned according to CS vein anatomy in 130 posterolateral, 97 anterolateral and 28 anterior side branches (16 patients received 2 CS leads). Over-the-wire leads were used in 88%, 71% were additionally preshaped. We observed no mortality but 37 complications (12.5%): CS dissection in 9, CS perforation in 1, ventricular fibrillation in 4, asystole in 5, pulmonary edema in 1, pneumothorax in 2, need for early CS lead revision in 19 (dislodgement n=7, phrenic nerve stimulation n=12) and infection with explantation in 2 cases. An improvement in NYHA functional class was found in 88% of pts (only 55% if anterior lead position). CONCLUSION: Perioperative complications during CS lead implantation occur in 10-15% of cases. Most patients responded well to CRT. Patients should be informed about the possible need for a reoperation. During implantation, immediate defibrillation and stimulation capabilities must be available. Anterior lead positions should be avoided.


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/prevenção & controle , Eletrodos Implantados , Marca-Passo Artificial/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Implantação de Prótese/estatística & dados numéricos , Medição de Risco/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estimulação Cardíaca Artificial/estatística & dados numéricos , Comorbidade , Vasos Coronários/cirurgia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Veias/cirurgia
20.
Herzschrittmacherther Elektrophysiol ; 17(4): 185-90, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17211748

RESUMO

BACKGROUND: Acute studies in cardiac resynchronization therapy (CRT) showed that hemodynamic effects may depend on the coronary sinus (CS) lead position. However, there are no data on the longterm effect of CS lead position. METHODS: In 45 heart failure patients with left bundle branch block and QRS >150 ms (age 59+/-10 years, 17 dilative cardiomyopathy, 23 ischemic, 5 valvular), biventricular pacemakers were implanted. CS leads were positioned in posterior (P, n=15), lateral (L, n=19) or, if no other option available, anterior (A, n=11) side branches. Before and 6 months after implantation, clinical state, echocardiography, brain natriuretic peptide (BNP) and right heart catheterization were evaluated. RESULTS: Baseline parameters were similar between groups. After 6 months, there were 32/34 responders in groups P and L compared to 7/11 responders in group A (94 vs groups P and L: Arterial pressure +8 and +9% vs +2%; PCWP -23 and -15% vs -4%, pulmonary pressure -18 and -12% vs -3% (p<0.01 for A vs P+L); cardiac index +21 and +12% vs +11% (p=0.03 for A vs P). BNP was reduced by 55, 35, and 27% (p=0.05 for A vs P). Ejection fraction increased in P and L by 40 and 41%, respectively, but only by +19% in A (p<0.03 for A vs P+L). CONCLUSION: Chronic CRT improves ejection fraction, BNP and hemodynamic measurements predominantly in patients with lateral and posterior CS lead positions. Anterior lead positions should be avoided.


Assuntos
Pressão Sanguínea/fisiologia , Bloqueio de Ramo/terapia , Débito Cardíaco/fisiologia , Eletrocardiografia , Insuficiência Cardíaca/terapia , Frequência Cardíaca/fisiologia , Contração Miocárdica/fisiologia , Marca-Passo Artificial , Pressão Propulsora Pulmonar/fisiologia , Volume Sistólico/fisiologia , Idoso , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/fisiopatologia , Dióxido de Carbono/sangue , Cateterismo Cardíaco , Ecocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Hemoglobinometria , Humanos , Masculino , Pessoa de Meia-Idade , Oxigênio/sangue , Função Ventricular Esquerda/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA