Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Am J Emerg Med ; 35(12): 1984.e1-1984.e2, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29037581

RESUMO

OBJECTIVE: Pulmonary embolism is a relatively common clinical presentation of venous thromboembolism, which develops in relation to acute pulmonary arterial occlusion mostly caused by thrombi of the lower limbs. CASE REPORT: 29year old female admitted to emergency department with pulmonary thromboembolism due to an ingestion of 17 Diana 35 pills (2 mg cyproterone acetate and 0.035mg ethinyl estradiol) in a suicide attempt without any previously known predisposing factors. After thrombolytic therapy, the patient was discharged with oral warfarin treatment. DISCUSSION: We know that exogenous estrogen increase the risk of venous thromboembolism in therapeutic use. It should be kept in mind that even single ingestion of a single high-dose exogenous estrogen intake may induce pulmonary thromboembolism.


Assuntos
Anticoagulantes/uso terapêutico , Anticoncepcionais Orais Hormonais/intoxicação , Overdose de Drogas/complicações , Embolia Pulmonar/induzido quimicamente , Tentativa de Suicídio , Varfarina/uso terapêutico , Adulto , Feminino , Humanos , Embolia Pulmonar/terapia , Terapia Trombolítica/métodos , Resultado do Tratamento
2.
ChemistryOpen ; 13(2): e202300120, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37824210

RESUMO

Point-of-care diagnosis is crucial to control the spreading of viral infections. Here, universal-modifiable probe-gated silica nanoparticles (SNPs) based lateral flow assay (LFA) is developed in the interest of the rapid and early detection of viral infections. The most superior advantage of the rapid assay is its utility in detecting various sides of the virus directly from the human swab samples and its adaptability to detect various types of viruses. For this purpose, a high concentration of fluorescein and rhodamine B as a reporting material was loaded into SNPs with excellent loading capacity and measured using standard curve, 4.19 µmol ⋅ g-1 and 1.23 µmol ⋅ g-1 , respectively. As a model organism, severe acute respiratory syndrome coronavirus-2 (CoV-2) infections were selected by targeting its nonstructural (NSP9, NSP12) and envelope (E) genes as target sites of the virus. We showed that NSP12-gated SNPs-based LFA significantly outperformed detection of viral infection in 15 minutes from 0.73 pg ⋅ mL-1 synthetic viral solution and with a dilution of 1 : 103 of unprocessed human samples with an increasing test line intensity compared to steady state (n=12). Compared to the RT-qPCR method, the sensitivity, specificity, and accuracy of NSP12-gated SNPs were calculated as 100 %, 83 %, and 92 %, respectively. Finally, this modifiable nanoparticle system is a high-performance sensing technique that could take advantage of upcoming point-of-care testing markets for viral infection detections.


Assuntos
COVID-19 , Nanopartículas , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Teste para COVID-19 , Sistemas Automatizados de Assistência Junto ao Leito
3.
Talanta ; 246: 123429, 2022 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-35461114

RESUMO

Viral infection has been one of the major health issues for human life. The real-time reverse transcription polymerase chain reaction (RT-PCR)-based detection has primarily been used for virus detection as a highly reliable procedure. However, it is a relatively long and multi-stage process. In addition, required skilled personnel and complex instrumentation presents difficulties in large scale monitoring efforts. Therefore, we report here a direct and fast detection method for CoV-2 genome as applied in the nose-throat swab samples without any further processing. The detection principle is based on fluorescein-loaded mesoporous silica nanoparticles capped by specific gene sequences probes immobilized on the surface of the nanoparticles. Upon hybridization with the target viral genome, the fluorescein molecules were released from the mesopores. Testing with synthetic oligonucleotides, the NSP12 gene-based detection resulted in a strong signal. Target detection time could be optimized to 15 min and the limit of detection was 1.4 RFU with 84% sensitivity with clinical samples (n = 43).


Assuntos
COVID-19 , Nanopartículas , Fluoresceínas , Humanos , RNA Viral/genética , SARS-CoV-2 , Sensibilidade e Especificidade , Dióxido de Silício
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA