Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Angiology ; 55(5): 557-60, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15378119

RESUMO

The totally implantable catheter system has gained popularity as venous access when prolonged treatment is needed. Despite its frequent use, intravascular fracture and embolization of catheter fragments from implantable venous port-catheter systems present a rare but potentially life-threatening complication. Any implanted catheters should therefore be removed after completion of the treatment or the system's integrity should be monitored on a regular basis. This report illustrates such a case, which presented with ventricular tachycardia triggered by changes in body position from a fractured Mediport catheter with cardiac migration. A 34-year-old woman had a venous port catheter (Mediport) implanted into the right subclavian vein for neoadjuvant radio-chemotherapy for Hodgkin's lymphoma. Owing to the patient's difficult venous access the catheter was left in situ after treatment. Three years after insertion of the Mediport she presented with shortness of breath and palpitations when lying in the left lateral position. Physical examination revealed no abnormalities. An electrocardiogram was within normal rhythm. An outpatient Holter monitor revealed multiple episodes of nonsustained and sustained ventricular tachycardia triggered by lying in the left lateral position. A chest radiograph showed a normal location of the port-system, but the distal fragment of the catheter had embolized into the right ventricle. The embolized fragment was extracted with a gooseneck snare technique and the reservoir of the system was removed under local anesthesia without any complications. The patient was free of symptoms at 7 seven months follow-up.


Assuntos
Cateterismo Venoso Central/efeitos adversos , Cateteres de Demora/efeitos adversos , Falha de Equipamento , Migração de Corpo Estranho , Bombas de Infusão Implantáveis , Taquicardia Ventricular/etiologia , Adulto , Cateterismo Venoso Central/instrumentação , Remoção de Dispositivo , Eletrocardiografia , Eletrocardiografia Ambulatorial , Feminino , Seguimentos , Ventrículos do Coração , Doença de Hodgkin/tratamento farmacológico , Humanos , Postura , Radiografia Torácica , Fatores de Tempo , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA