Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Heliyon ; 10(9): e30837, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38774106

RESUMO

Infrapositioning of implants in the maxillary anterior region can cause esthetic complications, including soft tissue problems. These complications commonly occur in implants placed in young adults. However, there are many clinical reports of implant infrapositioning in the maxillary anterior region after the fourth decade of life. This clinical report describes a case of infrapositioning of the maxillary central incisor wherein esthetic results were obtained through surgical and prosthetic approaches. The surgical approach improved the gingiva shape using the tunnel technique, and the prosthetic approach increased gingiva thickness by adjusting the shape of the abutment, resulting in a shape similar to the natural teeth.

2.
Sci Rep ; 14(1): 19185, 2024 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-39160217

RESUMO

Axial displacement of prosthetic components is a major concern in implant dentistry, particularly during screw tightening. However, implant manufacturers provide different recommended torques for tightening implant prosthetic components, which can lead to errors in prosthesis fit before and after impression making. Implant-abutment connection angle or abutment geometries can affect axial displacement. This study aimed to compare the axial displacement between conventional and digital components based on the tightening torque and differences in the implant-abutment connection angles and geometries. The results showed that scan bodies with different implant-abutment connection geometries exhibited smaller axial displacement with increasing tightening torque than other prosthetic components. Except for the scan bodies, there was no difference in the axial displacement of prosthetic components when tightened with the same torque. However, regardless of the use of digital or conventional method of impression making, the axial displacement between the impression making component and the abutment when tightened to the recommended torques were significantly different. In addition, axial displacement was affected by the internal connection angle. The results of this study indicate that the tightening torque and geometry of prosthetic components should be considered to prevent possible misfits which can occur before and after impression making.


Assuntos
Implantes Dentários , Torque , Humanos , Desenho Assistido por Computador , Técnica de Moldagem Odontológica , Dente Suporte , Projeto do Implante Dentário-Pivô/métodos
3.
Front Public Health ; 12: 1250945, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38410670

RESUMO

Introduction: Low-renin hypertension (LRH) accounts for approximately one-third of patients with hypertension and are more prevalent in women and the older adult population. Previous study has found a link between the renin-angiotensin-aldosterone system (RAAS) and sex hormones. However, there are insufficient data on the relationship between LRH and metabolic or musculoskeletal outcomes in older adults. Methods and materials: Among the 343 participants from a population-based cohort study conducted between May 2018 and August 2019, a total of 256 (86 men older than 50 years and 170 postmenopausal women) were included. The presence of LRH was defined as plasma renin activity (PRA) <1 ng/mL/h and systolic blood pressure (BP) ≥130 or diastolic BP ≥80 mmHg based on the 2017 ACC/AHA guidelines. Individuals with missing data, and those who had used medications that could affect PRA within the past six months were excluded. Bone mineral density (BMD), trabecular bone score (TBS), and appendicular lean mass (ALM) index were assessed using dual-energy X-ray absorptiometry; degraded TBS was defined as partially degraded to degraded levels (≤1.350). Muscle function was assessed according to the Asian Working Group for Sarcopenia guidelines. PRA was measured using radioimmunoassay. Results: The median age was 66 [61-72] years, and the body mass index (BMI) was 24.7 [23.0-26.4] kg/m2. Individuals with LRH, accounting for 34.8%, had lower diabetes mellitus; more dyslipidemia; and poorer muscle function, BMD, and TBS than those in the non-LRH group. In addition, PRA was positively correlated with C-peptide, HOMA-IR, TBS, and ALM index. After adjusting for covariates including age and BMI, LRH was negatively associated with femur neck T-score (adjusted ß = -0.30, 95% CI [-0.55 to -0.05], p = 0.021) and the presence of LRH was significantly associated with degraded TBS in women (adjusted odds ratio = 3.00, 95% CI [1.36-6.58], p = 0.006). Conclusion: Our findings suggest that LRH can influence clinical features and metabolic risk in older adults. Notably, LRH in postmenopausal women was linked to lower femur neck T-scores and degraded TBS, indicating sex-specific effects of LRH on bone health. Larger prospective studies are required to elucidate how changes in the RAAS affect metabolic and musculoskeletal outcomes in older adults.


Assuntos
Densidade Óssea , Renina , Masculino , Humanos , Feminino , Idoso , Estudos de Coortes , Densidade Óssea/fisiologia , Absorciometria de Fóton/métodos , República da Coreia/epidemiologia
4.
J Clin Med ; 13(1)2023 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-38202149

RESUMO

Evaluating tooth mobility is clinically significant, not only for diagnosing periodontal tissues but also in determining the overall periodontal treatment plan. Numerous studies related to tooth mobility have been conducted over the years, including the proposal of various classifications as well as the development of electronic devices for objective measurement. However, there is still no consensus on the measurement methods and criteria for assessing tooth mobility. In this study, we provide a comprehensive review of past and current tooth mobility classification and measurement methods. In order to propose a new method to intuitively evaluate tooth mobility based on previous studies, a digital approach capable of recording tooth micromovements induced by dynamic load should be considered.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA