Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Can Assoc Radiol J ; 74(1): 127-136, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35593132

RESUMO

Purpose: To evaluate the image quality of low voltage chest computed tomography with enhancement (CECT) using low-concentration-iodine contrast media (LCCM). Method: From 9 December to 19 December 2019, three different protocols were used for 263 patients undergoing chest CECT. Chest CECT was done using routine (300 mgI/ml contrast media with 100 kVp) protocol (group 1), LCCM (240 mgI/ml contrast media)-100 kVp protocol (group 2) and LCCM-80 kVp protocol (group 3) in 91, 97 and 75 patients, respectively. The overall diagnostic acceptability, anatomical depiction, noise and contrast-related artifacts were assessed. Additionally, the mean attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and figure of merit (FOM) in the aorta and the main pulmonary trunk were measured. Results: The overall diagnostic acceptability scores were not significantly different between groups 1 and 2 (P = .261); group 3 demonstrated significantly lower overall diagnostic acceptability score compared with group 1 (P = .011) or group 2 (P < .001). However, in CECT with iterative reconstruction (IR), the overall diagnostic acceptability scores did not show significant difference among 3 groups. Group 3 showed significantly lower effective radiation dose compared with group 1 (2.33 vs 1.22 mSv, P < .001) or group 2 (2.28 vs .22 mSv, P < .001). Conclusions: In 100 kVp chest CECT, the image quality of using 240 mg/mL iodinated contrast media is comparable to that using 300 mg/mL iodine contrast media, regardless of application of IR; with IR, chest CECT using 80 kVp and 240 mg/mL iodinated contrast media results in acceptable image quality and lower radiation dose.


Assuntos
Meios de Contraste , Iodo , Humanos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Razão Sinal-Ruído , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
2.
Can Assoc Radiol J ; 74(1): 137-146, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35840350

RESUMO

Purpose: To comprehensively evaluate qualitative and quantitative features for predicting invasiveness of pure ground-glass nodules (pGGNs) using multiplanar computed tomography. Methods: Ninety-three resected pGGNs (16 atypical adenomatous hyperplasia [AAH], 18 adenocarcinoma in situ [AIS], 31 minimally invasive adenocarcinoma [MIA], and 28 invasive adenocarcinoma [IA]) were retrospectively included. Two radiologists analyzed qualitative and quantitative features on three standard planes. Univariable and multivariable logistic regression analyses were performed to identify features to distinguish the pre-invasive (AAH/AIS) from the invasive (MIA/IA) group. Results: Tumor size showed high area under the curve (AUC) for predicting invasiveness (.860, .863, .874, and .893, for axial long diameter [AXLD], multiplanar long diameter, mean diameter, and volume, respectively). The AUC for AXLD (cutoff, 11 mm) was comparable to that of the volume (P = .202). The invasive group had a significantly higher number of qualitative features than the pre-invasive group, regardless of tumor size. Six out of 59 invasive nodules (10.2%) were smaller than 11 mm, and all had at least one qualitative feature. pGGNs smaller than 11 mm without any qualitative features (n = 16) were all pre-invasive. In multivariable analysis, AXLD, vessel change, and the presence or number of qualitative features were independent predictors for invasiveness. The model with AXLD and the number of qualitative features achieved the highest AUC (.902, 95% confidence interval .833-.971). Conclusion: In adenocarcinomas manifesting as pGGNs on computed tomography, AXLD and the number of qualitative features are independent risk factors for invasiveness; small pGGNs (<11 mm) without qualitative features have low probability of invasiveness.


Assuntos
Adenocarcinoma in Situ , Adenocarcinoma de Pulmão , Adenocarcinoma , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Estudos Retrospectivos , Invasividade Neoplásica/diagnóstico por imagem , Adenocarcinoma de Pulmão/diagnóstico por imagem , Adenocarcinoma de Pulmão/patologia , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/patologia , Adenocarcinoma in Situ/diagnóstico por imagem , Adenocarcinoma in Situ/patologia , Adenocarcinoma in Situ/cirurgia , Tomografia Computadorizada por Raios X/métodos , Hiperplasia
3.
Can Assoc Radiol J ; 74(4): 723-736, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36882380

RESUMO

Purpose: To evaluate the feasibility and usefulness of T1 and T2 mapping in characterization of mediastinal masses. Methods: From August 2019 through December 2021, 47 patients underwent 3.0-T chest MRI with T1 and post-contrast T1 mapping using modified look-locker inversion recovery sequences and T2 mapping using a T2-prepared single-shot shot steady-state free precession technique. Mean native T1, native T2, and post-contrast T1 values were measured by drawing the region of interest in the mediastinal masses, and enhancement index (EI) was calculated using these values. Results: All mapping images were acquired successfully, without significant artifact. There were 25 thymic epithelial tumors (TETs), 3 schwannomas, 6 lymphomas, and 9 thymic cysts, and 4 other cystic tumors. TET, schwannoma, and lymphoma were grouped together as "solid tumor," to be compared with thymic cysts and other tumors ("cystic tumors"). The mean post-contrast T1 mapping (P < .001), native T2 mapping (P < .001), and EI (P < .001) values showed significant difference between these two groups. Among TETs, high risk TETs (thymoma types B2, B3, and thymic carcinoma) showed significantly higher native T2 mapping values (P = .002) than low risk TETs (thymoma types A, B1, and AB). For all measured variables, interrater reliability was good to excellent (intraclass coefficient [ICC]: .869∼.990) and intrarater reliability was excellent (ICC: .911∼.995). Conclusion: The use of T1 and T2 mapping in MRI of mediastinal masses is feasible and may provide additional information in the evaluation of mediastinal masses.


Assuntos
Linfoma , Cisto Mediastínico , Timoma , Neoplasias do Timo , Humanos , Timoma/patologia , Cisto Mediastínico/patologia , Estudos de Viabilidade , Reprodutibilidade dos Testes , Neoplasias do Timo/diagnóstico por imagem , Neoplasias do Timo/patologia , Imageamento por Ressonância Magnética/métodos , Linfoma/diagnóstico por imagem
4.
Eur Radiol ; 32(7): 4361-4373, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35230519

RESUMO

OBJECTIVES: To evaluate the quality of radiomics studies using cardiac magnetic resonance imaging (CMR) according to the radiomics quality score (RQS), Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD) guidelines, and the standards defined by the Image Biomarker Standardization Initiative (IBSI) and identify areas needing improvement. MATERIALS AND METHODS: PubMed and Embase were searched to identify radiomics studies using CMR until March 10, 2021. Of the 259 identified articles, 32 relevant original research articles were included. Studies were scored according to the RQS, TRIPOD guidelines, and IBSI standards by two cardiac radiologists. RESULTS: The mean RQS was 14.3% of the maximum (5.16 out of 36). RQS were low for the demonstration of validation (-60.6%), calibration statistics (1.6%), potential clinical utility (3.1%), and open science (3.1%) items. No study conducted a phantom study or cost-effectiveness analysis. The adherence to TRIPOD guidelines was 55.9%. Studies were deficient in reporting title (3.1%), stating objective in abstract and introduction (6.3% and 9.4%), missing data (0%), discrimination/calibration (3.1%), and how to use the prediction model (3.1%). According to the IBSI standards, non-uniformity correction, image interpolation, grey-level discretization, and signal intensity normalization were performed in two (6.3%), four (12.5%), six (18.8%), and twelve (37.5%) studies, respectively. CONCLUSION: The quality of radiomics studies using CMR is suboptimal. Improvements are needed in the areas of validation, calibration, clinical utility, and open science. Complete reporting of study objectives, missing data, discrimination/calibration, how to use the prediction model, and preprocessing steps are necessary. KEY POINTS: • The quality of science in radiomics studies using CMR is currently inadequate. • RQS were low for validation, calibration, clinical utility, and open science; no study conducted a phantom study or cost-effectiveness analysis. • In stating the study objective, missing data, discrimination/calibration, how to use the prediction model, and preprocessing steps, improvements are needed.


Assuntos
Imageamento por Ressonância Magnética , Biomarcadores , Calibragem , Humanos , Imageamento por Ressonância Magnética/métodos , Prognóstico
5.
Eur Radiol ; 31(11): 8282-8290, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33890148

RESUMO

OBJECTIVES: To evaluate the effectiveness and safety of pleural anesthesia for CT-guided transthoracic needle biopsy (TNB). METHODS: This retrospective study was performed between March 2019 and August 2019 in a tertiary care hospital. Patients undergoing CT-guided TNB received either (a) pleural and skin anesthesia (pleural anesthesia group) or (b) skin anesthesia only (skin anesthesia group). Pain score was reported on a 0-5 numeric rating scale, and pain scores 3-5 were classified as significant pain. The relationship between pleural anesthesia and pain score, significant pain, and pneumothorax was assessed by using multivariable linear and logistic regression models. RESULTS: A total of 111 patients (67 men, 66.0 ± 11.4 years) were included (pleural anesthesia group, 38; skin anesthesia group, 73). Pleural anesthesia group reported lower pain score (1.4 ± 1.0 vs. 2.3 ± 1.1, p < 0.001) and less frequent significant pain (18.4% [7/38] vs. 42.5% [31/73], p = 0.020) than skin anesthesia group. Pain score was negatively associated with pleural anesthesia (ß = -0.93, p < 0.001) and positively associated with procedure time (ß = 0.06, p < 0.001). Significant pain was negatively associated with pleural anesthesia (p = 0.004, adjusted odds ratio [OR] = 0.21 [95% confidence interval: 0.07, 0.61]) and positively associated with procedure time (p < 0.001, adjusted OR = 1.15 [95% confidence interval: 1.07, 1.24]). Pleural anesthesia was not associated with pneumothorax or chest tube placement (p = 0.806 and 0.291, respectively). CONCLUSION: Pleural anesthesia reduces subjective pain without increasing the risk of pneumothorax. KEY POINTS: • Local pleural anesthesia is a simple method that can be added to the conventional skin anesthesia for CT-guided transthoracic needle biopsy. • The addition of local pleural anesthesia can effectively reduce pain compared to the conventional skin anesthesia method. • This procedure is not associated with an increased risk of pneumothorax or chest tube placement.


Assuntos
Manejo da Dor , Pneumotórax , Anestesia Local , Biópsia por Agulha , Humanos , Biópsia Guiada por Imagem , Pulmão , Masculino , Dor , Pneumotórax/etiologia , Radiografia Intervencionista , Estudos Retrospectivos , Fatores de Risco , Tomografia Computadorizada por Raios X
7.
Radiology ; 287(2): 442-451, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29272215

RESUMO

Purpose To investigate the diagnostic utility of dual-energy computed tomography (CT)-based monochromatic imaging for myocardial delayed enhancement (MDE) assessment in patients with cardiomyopathy. Materials and Methods The institutional review board approved this prospective study, and informed consent was obtained from all participants who were enrolled in the study. Forty patients (27 men and 13 women; mean age, 56 years ± 15 [standard deviation]; age range, 22-81 years) with cardiomyopathy underwent cardiac magnetic resonance (MR) imaging and dual-energy CT. Conventional (120-kV) and monochromatic (60-, 70-, and 80-keV) images were reconstructed from the dual-energy CT acquisition. Subjective quality score, contrast-to-noise ratio (CNR), and beam-hardening artifacts were compared pairwise with the Friedman test at post hoc analysis. With cardiac MR imaging as the reference standard, diagnostic performance of dual-energy CT in MDE detection and its predictive ability for pattern classification were compared pairwise by using logistic regression analysis with the generalized estimating equation in a per-segment analysis. The Bland-Altman method was used to find agreement between cardiac MR imaging and CT in MDE quantification. Results Among the monochromatic images, 70-keV CT images resulted in higher subjective quality (mean score, 3.38 ± 0.54 vs 3.15 ± 0.43; P = .0067), higher CNR (mean, 4.26 ± 1.38 vs 3.93 ± 1.33; P = .0047), and a lower value for beam-hardening artifacts (mean, 3.47 ± 1.56 vs 4.15 ± 1.67; P < .0001) when compared with conventional CT. When compared with conventional CT, 70-keV CT showed improved diagnostic performance for MDE detection (sensitivity, 94.6% vs 90.4% [P = .0032]; specificity, 96.0% vs 94.0% [P = .0031]; and accuracy, 95.6% vs 92.7% [P < .0001]) and improved predictive ability for pattern classification (subendocardial, 91.5% vs 84.3% [P = .0111]; epicardial, 94.3% vs 73.5% [P = .0001]; transmural, 93.0% vs 77.7% [P = .0018]; mesocardial, 85.4% vs 69.2% [P = .0047]; and patchy. 84.4% vs 78.4% [P = .1514]). For MDE quantification, 70-keV CT showed a small bias 0.1534% (95% limits of agreement: -4.7013, 5.0080). Conclusion Dual-energy CT-based 70-keV monochromatic images improve MDE assessment in patients with cardiomyopathy via improved image quality and CNR and reduced beam-hardening artifacts when compared with conventional CT images. © RSNA, 2017 Online supplemental material is available for this article.


Assuntos
Cardiomiopatias/patologia , Imageamento por Ressonância Magnética , Miocárdio/patologia , Interpretação de Imagem Radiográfica Assistida por Computador , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Cardiomiopatias/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
8.
AJR Am J Roentgenol ; 210(1): 43-51, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29091002

RESUMO

OBJECTIVE: The purpose of this study is to investigate adverse prognostic CT findings in patients with advanced-stage lung adenocarcinoma who are receiving epidermal growth factor receptor (EGFR)-tyrosine kinase inhibitor (TKI) therapy as first-line therapy. MATERIALS AND METHODS: We included 199 patients (71 men and 128 women; mean ± SD age, 64.3 ± 11.2 years) with stage IIIB or IV lung adenocarcinoma who received first-line EGFR-TKI therapy between January 2009 and December 2015. Clinical findings and imaging parameters on CT images obtained before TKI therapy were analyzed, including tumor size, TNM category according to the seventh edition of the American Joint Committee on Cancer lung cancer TNM staging system, tumor type, the presence of cavity or necrosis, pleural effusion, and metastasis to pleura, lung, and distant organs. Response evaluation was performed according to the Response Evaluation Criteria in Solid Tumor version 1.1 guidelines. Correlation of clinical and radiologic findings with durations of progression-free survival (PFS) and overall survival (OS) was evaluated using a Cox proportional hazard model. RESULTS: Pleural effusion (hazard ratio [HR], 2.095; 95% CI, 1.394-3.147; p < 0.001) and an N2 or N3 tumor category (HR, 2.145; 95% CI, 1.280-3.594; p = 0.004) were significantly associated with a short PFS duration in multivariate analysis. Older age (HR, 1.040; 95% CI, 1.014-1.067; p = 0.002), an N2 or N3 tumor category (HR, 2.427; 95% CI, 1.068-5.518; p = 0.034), pleural effusion (HR, 1.903; 95% CI, 1.105-3.276; p = 0.020), and distant metastasis (HR, 2.795; 95% CI, 1.356-5.765; p = 0.005) were associated with a short OS duration in multivariate analysis. CONCLUSION: Pre-TKI therapy CT findings of pleural effusion and high N-category tumors are associated with short durations of PFS and OS in patients with lung adenocarcinoma who are receiving EGFR-TKI therapy.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/tratamento farmacológico , Cloridrato de Erlotinib/uso terapêutico , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/tratamento farmacológico , Inibidores de Proteínas Quinases/uso terapêutico , Quinazolinas/uso terapêutico , Adenocarcinoma/patologia , Adenocarcinoma de Pulmão , Adulto , Idoso , Idoso de 80 Anos ou mais , Receptores ErbB , Feminino , Gefitinibe , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Derrame Pleural/diagnóstico por imagem , Derrame Pleural/etiologia , Prognóstico , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Adulto Jovem
9.
Eur Radiol ; 27(5): 1992-2001, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27553938

RESUMO

OBJECTIVES: To investigate the diagnostic value of dual-energy computed tomography (DECT) in differentiating between low- and high-risk thymomas and thymic carcinomas. MATERIALS: Our institutional review board approved this study, and patients provided informed consent. We prospectively enrolled 37 patients (20 males, mean age: 55.6 years) with thymic epithelial tumour. All patients underwent DECT. For quantitative analysis, two reviewers measured the following tumour parameters: CT attenuation value in contrast Hounsfield units (CHU), iodine-related HU and iodine concentration (mg/ml). Pathological results confirmed the final diagnosis. RESULTS: Of the 37 thymic tumours, 23 (62.2 %) were low-risk thymomas, five (13.5 %) were high-risk thymomas and nine (24.3 %) were thymic carcinomas. According to quantitative analysis, iodine-related HU and iodine concentration were significantly different among low-risk thymomas, high-risk thymomas and thymic carcinomas (median: 29.78 HU vs. 14.55 HU vs. 19.95 HU, p = 0.001 and 1.92 mg/ml vs. 0.99 mg/ml vs. 1.18 mg/ml, p < 0.001, respectively). CONCLUSION: DECT using a quantitative analytical method based on iodine concentration measurement can be used to differentiate among thymic epithelial tumours using single-phase scanning. KEY POINTS: • IHU and IC were lower in high-risk thymomas/carcinomas than in low-risk thymomas • IHU and IC were lower in advanced-stage thymomas than in early-stage thymomas • Dual-energy CT helps differentiate among thymic epithelial tumours.


Assuntos
Carcinoma/diagnóstico por imagem , Neoplasias Epiteliais e Glandulares/diagnóstico por imagem , Timoma/diagnóstico por imagem , Neoplasias do Timo/diagnóstico por imagem , Adulto , Idoso , Carcinoma/patologia , Meios de Contraste , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Iopamidol , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Neoplasias Epiteliais e Glandulares/patologia , Estudos Prospectivos , Timoma/patologia , Neoplasias do Timo/patologia , Tomografia Computadorizada por Raios X/métodos , Carga Tumoral
10.
Radiology ; 280(1): 49-57, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27322972

RESUMO

Purpose To evaluate the feasibility of equilibrium contrast material-enhanced dual-energy cardiac computed tomography (CT) to determine extracellular volume fraction (ECV) in nonischemic cardiomyopathy (CMP) compared with magnetic resonance (MR) imaging. Materials and Methods This study was approved by the institutional review board; informed consent was obtained. Seven healthy subjects and 23 patients (six with hypertrophic CMP, nine with dilated CMP, four with amyloidosis, and four with sarcoidosis) (mean age ± standard deviation, 57.33 years ± 14.82; 19 male participants [63.3%]) were prospectively enrolled. Twelve minutes after contrast material injection (1.8 mL/kg at 3 mL/sec), dual-energy cardiac CT was performed. ECV was measured by two observers independently. Hematocrit levels were compared between healthy subjects and patients with the Mann-Whitney U test. In per-subject analysis, interobserver agreement for CT was assessed with the intraclass correlation coefficient (ICC), and intertest agreement between MR imaging and CT was assessed with Bland-Altman analysis. In per-segment analysis, Student t tests in the linear mixed model were used to compare ECV on CT images between healthy subjects and patients. Results Hematocrit level was 43.44% ± 1.80 for healthy subjects and 41.23% ± 5.61 for patients with MR imaging (P = .16) and 43.50% ± 1.92 for healthy subjects and 41.35% ± 5.92 for patients with CT (P = .15). For observer 1 in per-subject analysis, ECV was 34.18% ± 8.98 for MR imaging and 34.48% ± 8.97 for CT. For observer 2, myocardial ECV was 34.42% ± 9.03 for MR imaging and 33.98% ± 9.05 for CT. Interobserver agreement for ECV at CT was excellent (ICC = 0.987). Bland-Altman analysis between MR imaging and CT showed a small bias (-0.06%), with 95% limits of agreement of -1.19 and 1.79. Compared with healthy subjects, patients with hypertrophic CMP, dilated CMP, amyloidosis, and sarcoidosis had significantly higher myocardial ECV at dual-energy equilibrium contrast-enhanced cardiac CT (all P < .01) in per-segment analysis. Conclusion Myocardial ECV with dual-energy equilibrium contrast-enhanced CT showed good agreement with MR imaging findings, suggesting the potential of myocardial tissue characterization with CT. (©) RSNA, 2016.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Intensificação de Imagem Radiográfica/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Estudos de Viabilidade , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Estudos Prospectivos , Reprodutibilidade dos Testes
11.
Radiology ; 281(2): 597-605, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27203543

RESUMO

Purpose To evaluate the feasibility of a simultaneous single scan of regional krypton and iodine concentrations by using dual-energy computed tomography (CT). Materials and Methods The study was approved by the institutional animal experimental committee. An airway obstruction model was first made in 10 beagle dogs, and a pulmonary arterial occlusion was induced in each animal after 1 week. For each model, three sessions of dual-energy CT (80% krypton ventilation [krypton CT], 80% krypton ventilation with iodine enhancement [mixed-contrast agent CT], and iodine enhancement [iodine CT]) were performed. Krypton maps were made from krypton and mixed-contrast agent CT, and iodine maps were made from iodine and mixed-contrast agent CT. Observers measured overlay Hounsfield units of the diseased and contralateral segments on each map. Values were compared by using the Wilcoxon signed-rank test. Results In krypton maps of airway obstruction, overlay Hounsfield units of diseased segments were significantly decreased compared with those of contralateral segments in both krypton and mixed-contrast agent CT (P = .005 for both). However, the values of mixed-contrast agent CT were significantly higher than those of krypton CT for both segments (P = .005 and .007, respectively). In iodine maps of pulmonary arterial occlusion, values were significantly lower in diseased segments than in contralateral segments for both iodine and mixed-contrast agent CT (P = .005 for both), without significant difference between iodine and mixed-contrast agent CT for both segments (P = .126 and .307, respectively). Conclusion Although some limitations may exist, it might be feasible to analyze regional krypton and iodine concentrations simultaneously by using dual-energy CT. © RSNA, 2016.


Assuntos
Obstrução das Vias Respiratórias/diagnóstico por imagem , Iodo/farmacocinética , Criptônio/farmacocinética , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Animais , Meios de Contraste/administração & dosagem , Meios de Contraste/farmacocinética , Cães , Estudos de Viabilidade , Iodo/administração & dosagem , Criptônio/administração & dosagem
12.
Eur Radiol ; 26(9): 3162-70, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26638163

RESUMO

OBJECTIVES: The purpose of this study was to determine whether dual-energy computed tomography (DECT) angiography could differentiate pulmonary thromboembolism (PTE) from pulmonary artery sarcoma (PAS). METHODS: We prospectively enrolled 19 patients that had a filling defect in the main pulmonary artery on DECT. Six patients who had PAS and underwent DECT were retrospectively enrolled for comparison. Pathological results or follow-up CT after anticoagulation therapy were used to make the final diagnosis. Two investigators measured the following parameters at the filling defect in the main pulmonary artery: CT attenuation density [Hounsfield units (HU)], iodine-related HU (IHU) and iodine concentration (IC, mg/ml). RESULTS: From a total of 25 patients (M:F = 10:15; mean age, 65 years old), 19 were categorised into the PTE group and six were categorised into the PAS group. The mean HU values were not significantly different between the PTE and PAS groups (45.5 ± 15.9 vs 47.1 ± 9.2 HU; P = 0.776). However, the mean IHU and IC values of the lesions were significantly different between the PTE and PAS groups (10.6 ± 7.2 vs 27.9 ± 9.1 HU; P = 0.004, and 0.61 ± 0.39 vs 1.49 ± 0.57; P = 0.001). CONCLUSIONS: DECT angiography using a quantitative analytic methodology can be used to differentiate PTE and PAS. KEY POINTS: • DECT can be useful for differentiation of PAS and PTE. • With quantitative analysis, DECT offers tissue characterisation by detecting lesion parameter increases. • The patients without predisposing factors for PTE can be candidates for DECT.


Assuntos
Neoplasias Pulmonares/diagnóstico , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico , Sarcoma/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Idoso , Angiografia , Diagnóstico Diferencial , Feminino , Humanos , Neoplasias Pulmonares/complicações , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Embolia Pulmonar/etiologia , Estudos Retrospectivos , Sarcoma/complicações
13.
Int J Med Sci ; 13(8): 620-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27499694

RESUMO

Patients with end-stage renal disease (ESRD) show characteristic abnormalities in cardiac structure and function. We evaluated the influence of these abnormalities on adverse cardiopulmonary outcomes after living donor kidney transplantation in patients with valid preoperative transthoracic echocardiographic evaluation. We then observed any development of major postoperative cardiovascular complications and pulmonary edema until hospital discharge. In-hospital major cardiovascular complications were defined as acute myocardial infarction, ventricular fibrillation/tachycardia, cardiogenic shock, newly-onset atrial fibrillation, clinical pulmonary edema requiring endotracheal intubation or dialysis. Among the 242 ESRD study patients, 9 patients (4%) developed major cardiovascular complications, and 39 patients (16%) developed pulmonary edema. Diabetes, ischemia-reperfusion time, left ventricular end-diastolic diameter (LVEDd), left ventricular mass index (LVMI), right ventricular systolic pressure (RVSP), left atrium volume index (LAVI), and high E/E' ratios were risk factors of major cardiovascular complications, while age, LVEDd, LVMI, LAVI, and high E/E' ratios were risk factors of pulmonary edema. The optimal E/E' cut-off value for predicting major cardiovascular complications was 13.0, showing 77.8% sensitivity and 78.5% specificity. Thus, the patient's E/E' ratio is useful for predicting in-hospital major cardiovascular complications after kidney transplantation. We recommend that goal-directed therapy employing E/E' ratio be enacted in kidney recipients with baseline diastolic dysfunction to avert postoperative morbidity. (http://Clinical Trials.gov number: NCT02322567).


Assuntos
Doenças Cardiovasculares/diagnóstico , Insuficiência Cardíaca Diastólica/diagnóstico , Falência Renal Crônica/fisiopatologia , Transplante de Rim/efeitos adversos , Edema Pulmonar/diagnóstico , Idoso , Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/fisiopatologia , Ecocardiografia Doppler , Feminino , Insuficiência Cardíaca Diastólica/diagnóstico por imagem , Insuficiência Cardíaca Diastólica/etiologia , Insuficiência Cardíaca Diastólica/fisiopatologia , Humanos , Falência Renal Crônica/complicações , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/diagnóstico por imagem , Doadores Vivos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Edema Pulmonar/diagnóstico por imagem , Edema Pulmonar/fisiopatologia , Fatores de Risco
14.
J Magn Reson Imaging ; 41(3): 747-54, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24500856

RESUMO

PURPOSE: To evaluate the usefulness of thin-section single-shot turbo spin echo with half-Fourier acquisition (SS-TSE-HF) alone for evaluation of local invasion of lung cancer. MATERIALS AND METHODS: Our Institutional Review Board approved this retrospective study. Thirty-six patients with lung cancer who underwent magnetic resonance imaging (MRI) for evaluation of local invasion followed by curative surgery from July 2008 to June 2012 were enrolled in this study. Two reviewers independently and blindly reviewed computed tomography (CT) and MRI (thin-section SS-TSE-HF and conventional MRI, which consisted of conventional axial SS-TSE-HF, dynamic MRI with respiratory and/or cardiac cine, and T1 -weighted high-resolution isotropic volume examination [THRIVE]) for the presence of local invasion. Diagnostic performances were evaluated using gross surgical findings and pathological results as a standard reference. RESULTS: The overall diagnostic performance for detecting local invasion of lung cancer between the two reviewers were as follows: specificity and accuracy of thin-section SS-TSE-HF (89.0% and 87.5%) were significantly higher than those of CT (25.6% and 46.9%, P < 0.001 for both) or conventional MRI (61.0% and 69.5%, P < 0.001 and P = 0.008, respectively). Sensitivity was 84.8% for thin-section SS-TSE-HF with the same value for CT (P = 0.246) and conventional MRI (P = 0.209). CONCLUSION: Thin-section SS-TSE-HF sequence alone without any contrast agent demonstrated a relatively high diagnostic performance in evaluation of local invasion of lung cancer.


Assuntos
Análise de Fourier , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
15.
Korean J Radiol ; 25(7): 634-643, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38942457

RESUMO

OBJECTIVE: This study aimed to evaluate the diagnostic efficacy and safety of low-contrast-dose, dual-source dual-energy CT before transcatheter aortic valve replacement (TAVR) in patients with compromised renal function. MATERIALS AND METHODS: A total of 54 consecutive patients (female:male, 26:38; 81.9 ± 7.3 years) with reduced renal function underwent pre-TAVR dual-energy CT with a 30-mL contrast agent between June 2022 and March 2023. Monochromatic (40- and 50-keV) and conventional (120-kVp) images were reconstructed and analyzed. The subjective quality score, vascular attenuation, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were compared among the imaging techniques using the Friedman test and post-hoc analysis. Interobserver reliability for aortic annular measurement was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. The procedural outcomes and incidence of post-contrast acute kidney injury (AKI) were assessed. RESULTS: Monochromatic images achieved diagnostic quality in all patients. The 50-keV images achieved superior vascular attenuation and CNR (P < 0.001 in all) while maintaining a similar SNR compared to conventional CT. For aortic annular measurement, the 50-keV images showed higher interobserver reliability compared to conventional CT: ICC, 0.98 vs. 0.90 for area and 0.97 vs. 0.95 for perimeter; 95% limits of agreement width, 0.63 cm² vs. 0.92 cm² for area and 5.78 mm vs. 8.50 mm for perimeter. The size of the implanted device matched CT-measured values in all patients, achieving a procedural success rate of 92.6%. No patient experienced a serum creatinine increase of ≥ 1.5 times baseline in the 48-72 hours following CT. However, one patient had a procedural delay due to gradual renal function deterioration. CONCLUSION: Low-contrast-dose imaging with 50-keV reconstruction enables precise pre-TAVR evaluation with improved image quality and minimal risk of post-contrast AKI. This approach may be an effective and safe option for pre-TAVR evaluation in patients with compromised renal function.


Assuntos
Meios de Contraste , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Idoso , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Doses de Radiação , Reprodutibilidade dos Testes , Insuficiência Renal , Estudos Retrospectivos , Razão Sinal-Ruído
16.
ESC Heart Fail ; 2024 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-38616291

RESUMO

The prevention and management of cancer therapy-related cardiac dysfunction (CTRCD) have become increasingly important. Recent studies have revealed the crucial role of genetics in determining the susceptibility to development of CTRCD. We present a case of a 65-year-old woman with breast cancer who developed recurrent CTRCD following low-dose chemotherapy, despite lacking conventional cardiovascular risk factors. Her medical history included anthracycline-associated cardiomyopathy, and her condition deteriorated significantly after treatment with HER2-targeted therapies. Through the use of multimodal imaging, we detected severe left ventricular systolic dysfunction. Further investigation with genetic testing revealed a likely pathogenic variant in the TNNT2 gene, suggesting a genetic predisposition to CTRCD. This case implies the potential role of genetic screening in identifying patients at risk for CTRCD and advocates for personalized chemotherapy and cardioprotective strategies.

17.
J Vasc Interv Radiol ; 24(9): 1353-60, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23891048

RESUMO

PURPOSE: To evaluate the prevalence of inferior mesenteric artery (IMA) collaterals to the uterus found during uterine artery embolization (UAE), associated risk factors, and clinical outcomes. MATERIALS AND METHODS: The records of 559 women who underwent UAE during the period 2008-2011 for uterine fibroids or adenomyosis found on magnetic resonance imaging were retrospectively analyzed. If IMA collaterals to the uterus were suspected on aortography performed after embolization, selective angiography was performed. Risk factors for IMA collaterals to the uterus were analyzed, including the presence of adenomyosis, baseline uterine volume, or prior pelvic surgery. RESULTS: Collaterals to the uterus were found from the ovarian artery (n = 21; 3.8%), IMA (n = 7; 1.3%), round ligament artery (n = 1; 0.2%), and internal pudendal artery (n = 1; 0.2%). IMA collaterals were found in seven patients. Of 185 patients, 6 (3.2%) had adenomyosis, with or without fibroids, which was significantly more frequent than the 1 (0.27%) of 374 patients who had fibroids only (P = .006). On multiple logistic regression analysis, the presence of adenomyosis (odds ratio, 19.556; P = .0168) and uterine volume (odds ratio, 1.003; P = .0069) were independent factors for the presence of IMA collaterals. Of the seven patients with IMA collaterals, embolization was not attempted in six, resulting in clinical failure in four. One patient who underwent IMA embolization with coils experienced clinical improvement. CONCLUSIONS: The IMA was the second most common (1.3%) source of collaterals to the uterus. IMA collaterals were more frequent in patients with adenomyosis than in patients with fibroids only, resulting in high frequency of treatment failure.


Assuntos
Leiomioma/diagnóstico por imagem , Leiomioma/terapia , Artérias Mesentéricas/diagnóstico por imagem , Embolização da Artéria Uterina/estatística & dados numéricos , Artéria Uterina/diagnóstico por imagem , Neoplasias Uterinas/diagnóstico por imagem , Neoplasias Uterinas/terapia , Adenomiose/diagnóstico por imagem , Adenomiose/epidemiologia , Adulto , Causalidade , Feminino , Humanos , Leiomioma/epidemiologia , Pessoa de Meia-Idade , Prevalência , Radiografia , República da Coreia/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Neoplasias Uterinas/epidemiologia
18.
Thorac Cancer ; 14(24): 2459-2466, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37409441

RESUMO

BACKGROUND: Pulmonary mucosa-associated lymphoid tissue (MALT) lymphoma sometimes presents as large pulmonary nodules composed of small nodular opacities (galaxy sign) on computed tomography (CT). The aim of this study was to assess the presence, usefulness, and pathological characteristics of the galaxy sign on CT of pulmonary MALT lymphoma. METHODS: From January 2011 to December 2021, chest CTs of 43 patients with pulmonary MALT lymphoma were reviewed by two radiologists for the galaxy sign and various other findings. Interreader agreement to characterize the galaxy sign and factors associated in making a correct first impression on CT prior to pathological diagnosis were assessed. Resected specimens were reviewed by two pathologists, and the proportion of peripheral lymphoma infiltrates was compared between lesions with and without the galaxy sign. RESULTS: Of 43 patients, 22 patients (44.2%) showed the galaxy sign (κ = 0.768, p < 0.0001). The galaxy sign (p = 0.010) was associated with making a correct first impression on CT prior to pathological diagnosis. On pathological examination, lesions showing the galaxy sign on CT demonstrated a significantly higher proportion of peripheral lymphoma infiltrates (p = 0.001). CONCLUSION: The galaxy sign can be seen on CT of pulmonary MALT lymphoma with a higher proportion of peripheral lymphoma infiltrates and may be useful in making a correct diagnosis of pulmonary MALT lymphoma.


Assuntos
Neoplasias Brônquicas , Linfoma de Zona Marginal Tipo Células B , Humanos , Linfoma de Zona Marginal Tipo Células B/diagnóstico , Radiografia , Tecido Linfoide/patologia , Mucosa
19.
Korean J Radiol ; 24(5): 395-405, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37133210

RESUMO

OBJECTIVE: This study aimed to develop and validate models using radiomics features on a native T1 map from cardiac magnetic resonance (CMR) to predict left ventricular reverse remodeling (LVRR) in patients with nonischemic dilated cardiomyopathy (NIDCM). MATERIALS AND METHODS: Data from 274 patients with NIDCM who underwent CMR imaging with T1 mapping at Severance Hospital between April 2012 and December 2018 were retrospectively reviewed. Radiomic features were extracted from the native T1 maps. LVRR was determined using echocardiography performed ≥ 180 days after the CMR. The radiomics score was generated using the least absolute shrinkage and selection operator logistic regression models. Clinical, clinical + late gadolinium enhancement (LGE), clinical + radiomics, and clinical + LGE + radiomics models were built using a logistic regression method to predict LVRR. For internal validation of the result, bootstrap validation with 1000 resampling iterations was performed, and the optimism-corrected area under the receiver operating characteristic curve (AUC) with 95% confidence interval (CI) was computed. Model performance was compared using AUC with the DeLong test and bootstrap. RESULTS: Among 274 patients, 123 (44.9%) were classified as LVRR-positive and 151 (55.1%) as LVRR-negative. The optimism-corrected AUC of the radiomics model in internal validation with bootstrapping was 0.753 (95% CI, 0.698-0.813). The clinical + radiomics model revealed a higher optimism-corrected AUC than that of the clinical + LGE model (0.794 vs. 0.716; difference, 0.078 [99% CI, 0.003-0.151]). The clinical + LGE + radiomics model significantly improved the prediction of LVRR compared with the clinical + LGE model (optimism-corrected AUC of 0.811 vs. 0.716; difference, 0.095 [99% CI, 0.022-0.139]). CONCLUSION: The radiomic characteristics extracted from a non-enhanced T1 map may improve the prediction of LVRR and offer added value over traditional LGE in patients with NIDCM. Additional external validation research is required.


Assuntos
Cardiomiopatia Dilatada , Humanos , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/patologia , Miocárdio/patologia , Meios de Contraste , Estudos Retrospectivos , Valor Preditivo dos Testes , Gadolínio , Remodelação Ventricular , Imagem Cinética por Ressonância Magnética/métodos
20.
Quant Imaging Med Surg ; 13(12): 8729-8738, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38106336

RESUMO

This study aimed to examine the imaging characteristics and clinical implications of atypical pleural lesions that mimic bone tumors and form along the inner margins of consecutive ribs. This retrospective analysis included 45 atypical pleural lesions arising from 13 patients who underwent chest computed tomography (CT) between April 2021 and March 2023. The clinical features, CT findings, and radiologic diagnoses prior to pathologic identification were examined. Pathological findings were reviewed in the surgically resected case. Subgroup analysis was performed based on the presence of concurrent typical pleural plaques. The mean age of the patients was 69.3±8.4 years with a predominance of males (76.9%). The lesions primarily exhibited unilateral involvement (84.6%), being most frequently located in the right mid-level posterior region. Calcification was present in 75.6% of cases, typically seen continuously along the ribs (82.4%). Adjacent rib changes were observed in 28.9% of cases. These lesions were frequently misdiagnosed as osteochondromas or bony spurs (55.6%) by thoracic radiologists. No significant growth was observed during follow-up (n=11, 47±41 months), and the pathological findings were consistent with pleural plaques. Patients with concurrent typical pleural plaques had more atypical pleural lesions without statistical significance (P=0.071) and showed a more even distribution (P=0.039). In conclusion, atypical pleural lesions resembling bone tumors along consecutive ribs represent a distinct subset of pleural plaques. Their unique distribution and morphology should be recognized by radiologists to avoid misinterpretation and unnecessary interventions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA