Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Fluoresc ; 33(1): 393-399, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36434442

RESUMO

pH plays a crucial role in cells, especially mitochondria, an important organelle. Developing probes with well-performance for pH detection is still in great demand. Therefore, we first synthesized an indole-based probe (MC-ID-OL) to detect mitochondrial pH changes. The emission wavelength of MC-ID-OL is 649 nm, which does not reach the near-infrared region (650-900 nm). To further enlarge the emission wavelength, probe MC-BI-OL was developed by replacing indolenine with benzoindole. As expected, the emission wavelength changed from 649 to 656 nm. MC-BI-OL probes could also detect pH changes and mitochondria's highly reversible proportional fluorescence localization. In addition, the fluorescence imaging of the MC-BI-OL in HeLa cells demonstrated that this probe could sense changes in the pH of mitochondria in cells.


Assuntos
Colorimetria , Corantes Fluorescentes , Humanos , Células HeLa , Concentração de Íons de Hidrogênio , Mitocôndrias
2.
J Fluoresc ; 2023 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-37498366

RESUMO

Fluorescent probes are sensitive, selective, nontoxic in detection and thus provided a new solution in biomedical, environmental monitoring, and food safety. In order to expand the application of fluorescent probes in various fields, the paper discusses the design, synthesis, and characterization of fluorescent probes, explores new design and development trends of fluorescent probes in various fields, and improves the performance and applicability of fluorescent probes by using new materials and technologies to meet the evolving demands of molecular detection in various fields.

3.
J Formos Med Assoc ; 121(10): 1972-1980, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35216883

RESUMO

BACKGROUND: The study aimed to explore the characteristics, predictors, and chronological trends of outcomes for adult out-of-hospital cardiac arrests (OHCAs) with shockable rhythms. METHODS: A 7-year, community-wide observational study using an Utstein-style registry was conducted. Patients who were not transported, those who experienced trauma and those who lacked electronic electrocardiography data were excluded; those with initial shockable rhythms of ventricular fibrillation (VF) or pulseless ventricular tachycardia (pVT) were included. Outcomes were survival of discharge (SOD) and favorable neurological status (CPC 1-2). The outcome predictors, chronological trends, and their relationship with system interventions were analyzed. RESULTS: Of the 1544 shockable OHCAs (incidence 12.6%) included, 97.6% had VF and 2.4% had pVT. VF showed better outcomes than pVT. Predictors for both outcomes (SOD; CPC 1-2) were chronological change (adjusted odds ratio [aOR]: 1.133; 1.176), younger age (aOR: 0.973; 0.967), shorter response time (aOR: 0.998; 0.999), shorter scene time (aOR: 0.999; 0.999), witnessed collapse (aOR: 1.668; 1.670), and bystander cardiopulmonary resuscitation (BCPR) (aOR: 1.448; 1.576). Predictors for only SOD were public location (aOR: 1.450) and successful prehospital defibrillation (aOR: 3.374). The use of the supraglottic airway was associated with adverse outcomes. Chronologically with system interventions, BCPR rate, the proportion of shockable OHCA, and improved neurological outcomes increased over time. CONCLUSION: The incidence of shockable OHCA remained low in Asian community. VF showed better outcomes than pVT. Over time, the incidence of shockable rhythm, BCPR rate and patient outcomes did improve with health system interventions. The number of prehospital defibrillations did not predict outcomes.


Assuntos
Reanimação Cardiopulmonar , Serviços Médicos de Emergência , Parada Cardíaca Extra-Hospitalar , Taquicardia Ventricular , Humanos , Parada Cardíaca Extra-Hospitalar/epidemiologia , Parada Cardíaca Extra-Hospitalar/terapia , Prognóstico , Sistema de Registros , Taquicardia Ventricular/complicações , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/terapia , Taiwan/epidemiologia , Fibrilação Ventricular/complicações , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/terapia
4.
Mater Sci Eng C Mater Biol Appl ; 63: 185-91, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27040210

RESUMO

A biomarker is related to the biological status of a living organism and shows great promise for the early prediction of a related disease. Herein we presented a novel structured light-addressable potentiometric sensor (LAPS) for the determination of a model biomarker, human immunoglobulin G (hIgG). In this system, the goat anti-human immunoglobulin G antibody was used as recognition element and covalently immobilized on the surface of light-addressable potentiometric sensor chip to capture human immunoglobulin G. Due to the light addressable capability of light-addressable potentiometric sensor, human immunoglobulin G dissolved in the supporting electrolyte solution can be detected by monitoring the potential shifts of the sensor. In order to produce a stable photocurrent, the laser diode controlled by field-programmable gate array was used as the light emitter to drive the light-addressable potentiometric sensor. A linear correlation between the potential shift response and the concentration of human immunoglobulin G was achieved and the corresponding regression equation was ΔV (V)=0.00714ChIgG (µg/mL)-0.0147 with a correlation coefficient of 0.9968 over a range 0-150 µg/mL. Moreover, the light-addressable potentiometric sensor system also showed acceptable stability and reproducibility. All the results demonstrated that the system was more applicable to detection of disease biomarkers with simple operation, multiple-sample format and might hold great promise in various environmental, food, and clinical applications.


Assuntos
Biomarcadores/análise , Potenciometria , Técnicas Biossensoriais , Humanos , Imunoglobulina G/análise , Luz , Limite de Detecção , Espectroscopia Fotoeletrônica , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA