Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Phys Rev Lett ; 130(5): 051801, 2023 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-36800472

RESUMO

The KamLAND-Zen experiment has provided stringent constraints on the neutrinoless double-beta (0νßß) decay half-life in ^{136}Xe using a xenon-loaded liquid scintillator. We report an improved search using an upgraded detector with almost double the amount of xenon and an ultralow radioactivity container, corresponding to an exposure of 970 kg yr of ^{136}Xe. These new data provide valuable insight into backgrounds, especially from cosmic muon spallation of xenon, and have required the use of novel background rejection techniques. We obtain a lower limit for the 0νßß decay half-life of T_{1/2}^{0ν}>2.3×10^{26} yr at 90% C.L., corresponding to upper limits on the effective Majorana neutrino mass of 36-156 meV using commonly adopted nuclear matrix element calculations.

2.
Phys Rev Lett ; 130(5): 051803, 2023 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-36800477

RESUMO

The COHERENT Collaboration searched for scalar dark matter particles produced at the Spallation Neutron Source with masses between 1 and 220 MeV/c^{2} using a CsI[Na] scintillation detector sensitive to nuclear recoils above 9 keV_{nr}. No evidence for dark matter is found and we thus place limits on allowed parameter space. With this low-threshold detector, we are sensitive to coherent elastic scattering between dark matter and nuclei. The cross section for this process is orders of magnitude higher than for other processes historically used for accelerator-based direct-detection searches so that our small, 14.6 kg detector significantly improves on past constraints. At peak sensitivity, we reject the flux consistent with the cosmologically observed dark-matter concentration for all coupling constants α_{D}<0.64, assuming a scalar dark-matter particle. We also calculate the sensitivity of future COHERENT detectors to dark-matter signals which will ambitiously test multiple dark-matter spin scenarios.

3.
Phys Rev Lett ; 129(8): 081801, 2022 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-36053683

RESUMO

We measured the cross section of coherent elastic neutrino-nucleus scattering (CEvNS) using a CsI[Na] scintillating crystal in a high flux of neutrinos produced at the Spallation Neutron Source at Oak Ridge National Laboratory. New data collected before detector decommissioning have more than doubled the dataset since the first observation of CEvNS, achieved with this detector. Systematic uncertainties have also been reduced with an updated quenching model, allowing for improved precision. With these analysis improvements, the COHERENT Collaboration determined the cross section to be (165_{-25}^{+30})×10^{-40} cm^{2}, consistent with the standard model, giving the most precise measurement of CEvNS yet. The timing structure of the neutrino beam has been exploited to compare the CEvNS cross section from scattering of different neutrino flavors. This result places leading constraints on neutrino nonstandard interactions while testing lepton flavor universality and measures the weak mixing angle as sin^{2}θ_{W}=0.220_{-0.026}^{+0.028} at Q^{2}≈(50 MeV)^{2}.

4.
Phys Rev Lett ; 126(1): 012002, 2021 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-33480779

RESUMO

We report the first measurement of coherent elastic neutrino-nucleus scattering (CEvNS) on argon using a liquid argon detector at the Oak Ridge National Laboratory Spallation Neutron Source. Two independent analyses prefer CEvNS over the background-only null hypothesis with greater than 3σ significance. The measured cross section, averaged over the incident neutrino flux, is (2.2±0.7)×10^{-39} cm^{2}-consistent with the standard model prediction. The neutron-number dependence of this result, together with that from our previous measurement on CsI, confirms the existence of the CEvNS process and provides improved constraints on nonstandard neutrino interactions.

5.
Phys Rev Lett ; 122(19): 192501, 2019 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-31144924

RESUMO

We present a precision analysis of the ^{136}Xe two-neutrino ßß electron spectrum above 0.8 MeV, based on high-statistics data obtained with the KamLAND-Zen experiment. An improved formalism for the two-neutrino ßß rate allows us to measure the ratio of the leading and subleading 2νßß nuclear matrix elements (NMEs), ξ_{31}^{2ν}=-0.26_{-0.25}^{+0.31}. Theoretical predictions from the nuclear shell model and the majority of the quasiparticle random-phase approximation (QRPA) calculations are consistent with the experimental limit. However, part of the ξ_{31}^{2ν} range allowed by the QRPA is excluded by the present measurement at the 90% confidence level. Our analysis reveals that predicted ξ_{31}^{2ν} values are sensitive to the quenching of NMEs and the competing contributions from low- and high-energy states in the intermediate nucleus. Because these aspects are also at play in neutrinoless ßß decay, ξ_{31}^{2ν} provides new insights toward reliable neutrinoless ßß NMEs.

6.
Eur Phys J C Part Fields ; 77(11): 785, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-31997932

RESUMO

This paper reports on the development of a technology involving 100 Mo -enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ( ∼ 1 kg ), high optical quality, radiopure 100 Mo -containing zinc and lithium molybdate crystals have been produced and used to develop high performance single detector modules based on 0.2-0.4 kg scintillating bolometers. In particular, the energy resolution of the lithium molybdate detectors near the Q-value of the double-beta transition of 100 Mo (3034 keV) is 4-6 keV FWHM. The rejection of the α -induced dominant background above 2.6 MeV is better than 8 σ . Less than 10 µ Bq/kg activity of 232 Th ( 228 Th ) and 226 Ra in the crystals is ensured by boule recrystallization. The potential of 100 Mo -enriched scintillating bolometers to perform high sensitivity double-beta decay searches has been demonstrated with only 10 kg × d exposure: the two neutrino double-beta decay half-life of 100 Mo has been measured with the up-to-date highest accuracy as T 1 / 2 = [6.90 ± 0.15(stat.) ± 0.37(syst.)] × 10 18 years . Both crystallization and detector technologies favor lithium molybdate, which has been selected for the ongoing construction of the CUPID-0/Mo demonstrator, containing several kg of 100 Mo .

7.
Artigo em Inglês | MEDLINE | ID: mdl-18244818

RESUMO

Eye movements (EMs) are an important aspect of human visual behavior. The temporal and space-variant nature of sampling a visual scene requires frequent attentional gaze shifts (saccades) to fixate onto different parts of an image. Fixations are often directed toward the most informative regions in the visual scene. We introduce a model and its simulation that can select such regions based on prior knowledge of similar scenes. Having representations of scenes as a probabilistic combination of regions with certain properties, it is possible to assess the likely contribution of each region in the successive recognition process. Using Bayesian conditional probabilities for each region given the scene category, the model can then predict the informative value of that region and initiate a spatial information-gathering algorithm analogous to an EM saccade to a new fixation.

8.
Chem Heterocycl Compd (N Y) ; 47(12): 1516-1526, 2012 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-24501430

RESUMO

Organocuprates efficiently undergo reaction with heterocyclic propargyl mesylates at low temperature to produce N-fused heterocycles. The copper reagent plays a "double duty" in this cascade transformation, which proceeds through an SN2'-substitution followed by a consequent cycloisomerization step.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA