RESUMO
Excimer Laser Coronary Atherectomy (ELCA) is a well-established therapy that emerged for the treatment of peripheral vascular atherosclerosis in the late 1980s, at a time when catheters and materials were rudimentary and associated with the most serious complications. Refinements in catheter technology and the introduction of improved laser techniques have led to their effective use for the treatment of a wide spectrum of complex coronary lesions, such as thrombotic lesions, severe calcific lesions, non-crossable or non-expandable lesions, chronic occlusions, and stent under-expansion. The gradual introduction of high-energy strategies combined with the contrast infusion technique has enabled us to treat an increasing number of complex cases with a low rate of periprocedural complications. Currently, the use of the ELCA has also been demonstrated to be effective in acute coronary syndrome (ACS), especially in the context of large thrombotic lesions.
Assuntos
Aterectomia Coronária , Intervenção Coronária Percutânea , Aterectomia Coronária/métodos , Angiografia Coronária , Humanos , Lasers de Excimer/uso terapêutico , Intervenção Coronária Percutânea/métodos , Tecnologia , Resultado do TratamentoRESUMO
Interventional cardiac procedures can be complex and involve extensive use of low dose rate fluoroscopy and high dose rate in image acquisition mode; hence, staff may receive significant radiation exposure. Radiation exposure to operators was assessed in 173 procedures. Fluoroscopy time, number of acquired images and dose-area product were recorded and occupational dose assessed with thermoluminescence dosemeters. The effective dose to the operator was compared with relevant literature data: values found were generally lower than those reported for other interventional cardiology laboratories. This is probably because of the strict radiation protection policy in our centre. Higher effective doses were found for defibrillator implantation and percutaneous transluminal coronary angiography procedures; for other cardiac procedures, effective dose was lower. Yearly extrapolated occupational doses to cardiologists are lower than the regulatory dose limit and in the lower band of doses reported in the literature.
Assuntos
Cardiologia/métodos , Angiografia Coronária/métodos , Eletrofisiologia/métodos , Fluoroscopia/métodos , Exposição Ocupacional , Proteção Radiológica/métodos , Radiografia Intervencionista/métodos , Algoritmos , Desfibriladores , Hemodinâmica , Humanos , Doses de Radiação , Monitoramento de Radiação/métodosRESUMO
With the increase in number and complexity of interventional cardiology (IC) procedures, it is important to monitor skin dose in order to decrease skin injuries. This study investigated radiation doses for patients undergoing IC procedures, compare results with the literature and define a local dose-area product trigger level for operators to identify situations likely to exceed the threshold for transient skin erythema of 2 Gy. Dosimetric data were collected for 77 haemodynamic and 90 electrophysiological procedures. Mean maximum local skin doses (MSDs) were 0.28 Gy for coronary angiography, 1.03 Gy for percutaneous transluminal coronary angioplasty (PTCA), 0.03 Gy for pacemaker insertion, 0.17 Gy for radiofrequency ablation for nodal tachycardia, 0.10 Gy for WPW and 0.22 Gy for atrial flutter. Since MSD values for the other procedures were well below the deterministic effect limit, a trigger level of 140 Gy cm2 was derived for PTCA procedures alone.