Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 128
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Exp Eye Res ; 247: 110045, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39154819

RESUMO

The choroid, which is a highly vascularized layer between the retina and sclera, is essential for supplying oxygen and nutrients to the outer retina. Choroidal vascular dysfunction has been implicated in numerous ocular diseases, including age-related macular degeneration, central serous chorioretinopathy, polypoidal choroidal vasculopathy, and myopia. Traditionally, the in vivo assessment of choroidal blood flow relies on techniques such as laser Doppler flowmetry, laser speckle flowgraphy, pneumotonometry, laser interferometry, and ultrasonic color Doppler imaging. While the aforementioned methods have provided valuable insights into choroidal blood flow regulation, their clinical applications have been limited. Recent advancements in optical coherence tomography and optical coherence tomography angiography have expanded our understanding of the choroid, allowing detailed visualization of the larger choroidal vessels and choriocapillaris, respectively. This review provides an overview of the available techniques that can investigate the choroid and its blood flow in vivo. Future research should combine these techniques to comprehensively image the entire choroidal microcirculation and develop robust methods to quantify choroidal blood flow. The potential findings will provide a better picture of choroidal hemodynamics and its effect on ocular health and disease.


Assuntos
Corioide , Fluxo Sanguíneo Regional , Tomografia de Coerência Óptica , Corioide/irrigação sanguínea , Corioide/diagnóstico por imagem , Humanos , Fluxo Sanguíneo Regional/fisiologia , Tomografia de Coerência Óptica/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Fluxometria por Laser-Doppler/métodos , Angiofluoresceinografia/métodos , Microcirculação/fisiologia , Técnicas de Diagnóstico Oftalmológico
2.
Retina ; 42(3): 529-539, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35188491

RESUMO

PURPOSE: To evaluate the interrelationship between macular sensitivity and retinal perfusion density (PD) in eyes with myopic macular degeneration (MMD). METHODS: One hundred and thirty-eight highly myopic eyes from 82 adult participants were recruited. Macular sensitivity was evaluated using the Microperimeter MP-3. Retinal PD was measured using the PLEX Elite 9000 swept source optical coherence tomography angiography. Macular sensitivity values between different categories of MMD and its relationship with optical coherence tomography angiography measurements were evaluated using multivariable linear mixed models, adjusting for age and axial length. RESULTS: Macular sensitivity reduced with increasing severity of MMD (ß ≤ -0.95, P < 0.001), whereas the best-corrected visual acuity was not associated with MMD severity (P > 0.04). Persons who were older (ß = -0.08, P < 0.001), with longer axial length (ß = -0.32, P = 0.005), presence of macular diffuse choroidal atrophy (ß = -2.16, P < 0.001) or worse MMD (ß = -5.70, P < 0.001), and presence of macular posterior staphyloma (ß ≤ -2.98, P < 0.001) or Fuchs spot (ß = -1.58, P = 0.04) were associated with reduced macular sensitivity. Macular sensitivity was significantly associated with deep retinal PD in MMD (ß = 0.15, P = 0.004) but not with superficial retinal PD (P = 0.62). CONCLUSION: There was a strong correlation between reduced macular sensitivity and increasing MMD severity, even in mild MMD independent of the best-corrected visual acuity. Furthermore, macular sensitivity was correlated with deep retinal PD, suggesting a vasculature-function relationship in MMD.


Assuntos
Degeneração Macular/fisiopatologia , Miopia Degenerativa/fisiopatologia , Retina/fisiologia , Vasos Retinianos/fisiopatologia , Adulto , Idoso , Comprimento Axial do Olho , Capilares/fisiopatologia , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Degeneração Macular/diagnóstico , Masculino , Pessoa de Meia-Idade , Miopia Degenerativa/diagnóstico , Refração Ocular , Sensibilidade e Especificidade , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia , Testes de Campo Visual , Campos Visuais/fisiologia
3.
Am J Physiol Heart Circ Physiol ; 320(1): H23-H28, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33275537

RESUMO

In neural tissues, the coupling between neural activity and blood flow is a physiological key principle in blood flow regulation. We used optical coherence tomography angiography to investigate stimulus-evoked hemodynamic responses in different microvascular layers of the human retina. Twenty-two healthy subjects were included. Vessel density before and during light stimulation was measured using optical coherence tomography angiography and assessed for the superficial, intermediate, and deep capillary plexus of the retinal circulation. Volumetric blood flow was measured using a custom-built Doppler optical coherence tomography system. Our results show that flicker stimulation induced a significant increase in the vessel density of +9.9 ± 6.7% in the superficial capillary plexus, +6.6 ± 1.7% in the intermediate capillary plexus, and +4.9 ± 2.3% in the deep capillary plexus. The hyperemic response of the superficial capillary plexus was significantly higher compared to the intermediate capillary plexus (P = 0.02) and deep capillary plexus (P = 0.002). Volumetric retinal blood flow increased by +39.9 ± 34.9% in arteries and by +29.8 ± 16.8% in veins. In conclusion, we showed a strong increase in the retinal microvascular density in response to light stimulation, with the most pronounced effect in the superficial capillary plexus. This is compatible with the hypothesis that the microvasculature exerts an important function in mediating functional hyperemia in humans.NEW & NOTEWORTHY We present vessel density alterations in response to flicker stimulation using optical coherence tomography angiography and identified the superficial capillary plexus as the layer with the most pronounced effect. This points out the physiological importance of the microvasculature in mediating functional hyperemia and suggests a fine-tuned plexus-specific mechanism to meet cellular metabolic demands.


Assuntos
Angiografia , Microcirculação , Microvasos/diagnóstico por imagem , Acoplamento Neurovascular , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica , Adulto , Feminino , Voluntários Saudáveis , Humanos , Luz , Masculino , Microcirculação/efeitos dos fármacos , Microvasos/fisiologia , Microvasos/efeitos da radiação , Estimulação Luminosa , Fluxo Sanguíneo Regional , Vasos Retinianos/fisiologia , Vasos Retinianos/efeitos da radiação , Adulto Jovem
4.
Ophthalmology ; 128(3): 393-400, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32739337

RESUMO

PURPOSE: To evaluate the association between different classes of antihypertensive medication with retinal nerve fiber layer (RNFL) and ganglion cell-inner plexiform layer (GC-IPL) thickness in a nonglaucomatous multiethnic Asian population. DESIGN: Population-based, cross-sectional study. PARTICIPANTS: A total of 9144 eyes for RNFL analysis (2668 Malays, 3554 Indians, and 2922 Chinese) and 8549 eyes for GC-IPL analysis (2460 Malays, 3230 Indians, and 2859 Chinese) aged 44 to 86 years. METHODS: Participants underwent standardized systemic and ocular examinations and interviewer-administered questionnaires for collection of data on medication and other variables. Intraocular pressure (IOP) readings were obtained by Goldmann applanation tonometry before pupil dilation for fundoscopy and OCT imaging. Blood pressure (BP) was measured with an automatic BP monitor. Mean arterial pressure (MAP) was defined as diastolic BP plus 1/3 (systolic BP - diastolic BP). Regression models were used to investigate the association of antihypertensive medication with OCT measurements of RNFL and GC-IPL. MAIN OUTCOME MEASURES: Average and sectoral RNFL and GC-IPL thickness. RESULTS: After adjusting for age, gender, ethnicity, MAP, IOP, body mass index (BMI), and presence of diabetes, we found that participants taking any type of antihypertensive medication (ß = -0.83; 95% confidence interval [CI], -1.46 to -0.02; P = 0.01), specifically angiotensin-converting enzyme inhibitors (ACEIs) (ß = -1.66; 95% CI, -2.57 to -0.75; P < 0.001) or diuretics (ß = -1.38; 95% CI, -2.59 to -0.17; P < 0.05), had thinner average RNFL in comparison with participants who were not receiving antihypertensive treatment. Use of a greater number of antihypertensive medications was significantly associated with thinner average RNFL (P for trend = 0.001). This association was most evident in the inferior RNFL quadrant in participants using ACEIs (ß = -2.44; 95% CI, -3.99 to -0.89; P = 0.002) or diuretics (ß = -2.76; 95% CI, -4.76 to -0.76; P = 0.007). A similar trend was noted in our analysis of macular GC-IPL thickness. CONCLUSIONS: Use of 2 or more antihypertensive medications, ACEI, and diuretics were associated with a loss of structural markers of retinal ganglion cell health in a multiethnic Asian population.


Assuntos
Inibidores da Enzima Conversora de Angiotensina/efeitos adversos , Anti-Hipertensivos/efeitos adversos , Diuréticos/efeitos adversos , Fibras Nervosas/efeitos dos fármacos , Doenças Retinianas/induzido quimicamente , Células Ganglionares da Retina/efeitos dos fármacos , Neurônios Retinianos/efeitos dos fármacos , Adulto , Idoso , Idoso de 80 Anos ou mais , Pressão Arterial/efeitos dos fármacos , Pressão Sanguínea/efeitos dos fármacos , Estudos Transversais , Feminino , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Doenças Retinianas/diagnóstico , Células Ganglionares da Retina/patologia , Neurônios Retinianos/patologia , Inquéritos e Questionários , Tomografia de Coerência Óptica , Tonometria Ocular
5.
Opt Lett ; 45(14): 3977-3980, 2020 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-32667332

RESUMO

In Fourier domain optical coherence tomography (FDOCT), the depth profile is mirrored about the zero delay between the sample and reference optical paths, limiting the imaging depth to half of the entire ranging space and undermining the optimal sensitivity window. We present a new method, to the best of our knowledge, to remove the complex conjugate artifact by using circularly polarized light as reference. Quadrature detection of the complex fringe is achieved by utilizing the intrinsic λ/4 delay between two polarization channels. We use passive broadband polarization optics to control the polarization state of the light in the reference and sample arms and a balanced polarization diversity detection unit to simultaneously detect phase-shifted fringes. We demonstrate a 40 dB artifact suppression ratio with a swept-source optical coherence tomography system. Our proposed method is immune to sample motion and laser phase noise, and imposes no restrictions to the source bandwidth, imaging speed, or computational power. In vivo images of the human finger, as well as the cornea and retina of a non-human primate, were demonstrated.

6.
Ophthalmology ; 125(11): 1729-1740, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29961552

RESUMO

PURPOSE: To evaluate changes in lamina cribrosa (LC) shape, curvature, and depth after trabeculectomy. DESIGN: Prospective, observational case series. PARTICIPANTS: A total of 112 patients (118 eyes) with open- or closed-angle glaucoma undergoing trabeculectomy. METHODS: The optic nerve head was imaged using enhanced depth imaging spectral-domain OCT before trabeculectomy and at 6 follow-up visits throughout the first postoperative year. The anterior LC surface and Bruch's membrane opening were marked in the serial horizontal B scans for the analysis of LC parameters using Morphology 1.0 software. Postoperative morphologic LC changes were assessed. MAIN OUTCOME MEASURES: The postoperative LC global shape index (GSI), nasal-temporal (N-T) and superior-inferior (S-I) curvatures, and mean and sectoral LC depth (LCD). RESULTS: The mean LC GSI increased only during the early postoperative period (P = 0.02), resulting in a change toward the saddle-rut shape. There was a flattening of the LC curvature in N-T (P < 0.001) and S-I (P = 0.003) meridians 12 months after trabeculectomy. A shallowing of the mean and sectoral LCD from baseline was significant throughout the entire follow-up period (P < 0.001) and progressed up to postoperative month 6. Twenty-eight patients showed a deepening of the LC from baseline in at least 1 visit. Eyes with shallower LCD compared with baseline responded to intraocular pressure (IOP) reduction with greater movement anteriorly than eyes with deeper LCD (P = 0.002). Greater IOP reduction (P = 0.007), less retinal nerve fiber layer thinning over the year (P = 0.003), and more superiorly-inferiorly curved baseline LC (P = 0.001) were associated with an increase in GSI. Younger age and IOP reduction were related to LC shallowing (P < 0.001, P = 0.002) and N-T flattening (P < 0.001). CONCLUSIONS: In most eyes, trabeculectomy resulted in long-term flattening and shallowing of the LC. However, in some eyes, LC deepened from baseline. Change in LC global shape appeared to be temporal. Reduction in IOP plays an important role in the early phase of LC change; however, in the later phase, LC remodeling may play a crucial role in view of stable IOP.


Assuntos
Glaucoma de Ângulo Fechado/cirurgia , Glaucoma de Ângulo Aberto/cirurgia , Disco Óptico/patologia , Doenças do Nervo Óptico/diagnóstico , Trabeculectomia/métodos , Idoso , Feminino , Seguimentos , Glaucoma de Ângulo Fechado/diagnóstico por imagem , Glaucoma de Ângulo Aberto/diagnóstico por imagem , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Disco Óptico/diagnóstico por imagem , Doenças do Nervo Óptico/fisiopatologia , Período Pós-Operatório , Estudos Prospectivos , Células Ganglionares da Retina/patologia , Tonometria Ocular , Acuidade Visual/fisiologia , Testes de Campo Visual , Campos Visuais/fisiologia
7.
Ophthalmology ; 124(9): 1271-1279, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28461014

RESUMO

PURPOSE: To investigate the difference in corneal hysteresis (CH) and corneal resistance factor (CRF) between Indian and Chinese populations. DESIGN: Population-based cross-sectional study. PARTICIPANTS: Three hundred eighty-two Singaporean Indian persons and 764 Singaporean Chinese 50 years of age or older were included from the Singapore Indian Eye Study and Singapore Chinese Eye Study, respectively. METHODS: Participants underwent standardized systemic and ocular examinations and interviewer-administered questionnaires for risk factor assessment. The CH and CRF were measured with the Ocular Response Analyzer (Reichert Ophthalmic Instruments, Buffalo, NY). Information on genetic ancestry was derived using principal component analysis. Linear regression models were used to investigate the association of CH and CRF with potential risk factors. MAIN OUTCOME MEASURES: Corneal hysteresis and CRF. RESULTS: After excluding participants with a history of intraocular surgery, a diagnosis of glaucoma suspect or glaucoma, refractive surgery, or presence of corneal abnormalities, CH and CRF readings were available for 382 Indian persons. For each Indian participant, 2 Chinese participants were selected and matched for age and gender (n = 764). There were no differences in the clinical measurements of CH (10.6±1.6 mmHg; P = 0.670) or CRF (10.3±1.7 mmHg; P = 0.103) between the ethnic groups. However, after adjusting for covariates, Indian persons had, on average, 0.18-mmHg higher CH levels than in Chinese (95% confidence interval [CI], 0.02-0.38; P = 0.031). Consistently, CH level was correlated significantly with genetic ancestry in the Southeast Asian population. Corneal resistance factor level was not associated independently with self-reported ethnicity (95% CI, -0.10 to 0.29; P = 0.335). CONCLUSIONS: Chinese have lower CH than Indian persons, and this disparity may reflect biomechanical differences of the cornea.


Assuntos
Povo Asiático/etnologia , Córnea/fisiologia , Elasticidade/fisiologia , Idoso , Povo Asiático/genética , Fenômenos Biomecânicos , Paquimetria Corneana , Estudos Transversais , Técnicas de Diagnóstico Oftalmológico/instrumentação , Feminino , Estudo de Associação Genômica Ampla , Humanos , Índia/epidemiologia , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Polimorfismo de Nucleotídeo Único , Fatores de Risco , Singapura/epidemiologia , Inquéritos e Questionários , Tonometria Ocular
8.
Ophthalmology ; 123(10): 2077-84, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27521171

RESUMO

PURPOSE: To determine the association of iris surface features with iris volume change after physiologic pupil dilation in adults. DESIGN: Cross-sectional observational study. PARTICIPANTS: Chinese adults aged ≥ 50 years without ocular diseases. METHODS: Digital iris photographs were taken from eyes of each participant and graded for crypts (by number and size) and furrows (by number and circumferential extent) following a standardized grading scheme. Iris color was measured objectively, using the Commission Internationale de l'Eclairage (CIE) L* color parameter (higher value denoting lighter iris). The anterior segment was imaged by swept-source optical coherence tomography (SS-OCT) (Casia; Tomey, Nagoya, Japan) under bright light and dark room conditions. Iris volumes in light and dark conditions were measured with custom semiautomated software, and the change in iris volume was quantified. Associations of the change in iris volume after pupil dilation with underlying iris surface features in right eyes were assessed using linear regression analysis. MAIN OUTCOME MEASURES: Iris volume change after physiologic pupil dilation from light to dark condition. RESULTS: A total of 65 Chinese participants (mean age, 59.8±5.7 years) had gradable data for iris surface features. In light condition, higher iris crypt grade was associated independently with smaller iris volume (ß [change in iris volume in millimeters per crypt grade increment] = -1.43, 95% confidence interval [CI], -2.26 to -0.59; P = 0.001) and greater reduction of iris volume on pupil dilation (ß [change in iris volume in millimeters per crypt grade increment] = 0.23, 95% CI, 0.06-0.40; P = 0.010), adjusting for age, gender, presence of corneal arcus, and change in pupil size. Iris furrows and iris color were not associated with iris volume in light condition or change in iris volume (all P > 0.05). CONCLUSIONS: Although few Chinese persons have multiple crypts on their irides, irides with more crypts were significantly thinner and lost more volume on pupil dilation. In view that the latter feature is known to be protective for acute angle-closure attack, it is likely that the macroscopic and microscopic composition of the iris is a contributing feature to angle-closure disease.


Assuntos
Imageamento Tridimensional , Pressão Intraocular/fisiologia , Iris/anatomia & histologia , Pupila/fisiologia , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Feminino , Seguimentos , Gonioscopia , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Projetos Piloto , Valores de Referência , Estudos Retrospectivos
9.
Ophthalmology ; 122(11): 2169-78, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26256834

RESUMO

PURPOSE: To determine the prevalence of age-related cataract and its ancestral and socioeconomic risk factors in a multi-ethnic Asian population. DESIGN: Population-based, cross-sectional study. PARTICIPANTS: A total of 10 033 adults (3353 Chinese, 3280 Malays, and 3400 Indians) aged >40 years in the Singapore Epidemiology of Eye Diseases Study. METHODS: Study participants were invited for a structured interview and received a standardized comprehensive eye examination. Digital lens photographs were taken from eyes of each participant and graded for nuclear, cortical, and posterior subcapsular (PSC) cataract, following the Wisconsin Cataract Grading System. Prevalence data were compared with the Blue Mountains Eye Study (BMES) in Australia. Information on medical and lifestyle factors was collected using questionnaires and blood samples. To increase the precision of racial definition, genetic ancestry was derived from genome-wide single nucleotide polymorphism markers using principal component analysis. Regression models were used to investigate the association of cataract with socioeconomic factors (education and income) and genetic ancestry. MAIN OUTCOME MEASURES: Age-related cataract. RESULTS: A total of 8750 participants (94.0%) had gradable lens photographs. The age-standardized prevalence of cataract surgery in Chinese (16.0%), Malays (10.6%), and Indians (20.2%) was higher than in white subjects (4.1%). We found the age-standardized cataract prevalence in Chinese (30.4%), Malays (37.8%), and Indians (33.1%) was higher than in whites (18.5%). Cataract was 1.5 to 2 times more common in Asians and began 10 years earlier than in white subjects. Malays had significantly higher age-standardized prevalence of nuclear, cortical, and PSC cataract than Chinese (P<0.001). The severity of nuclear, cortical, and PSC cataract was significantly correlated with genetic ancestry in our South East Asian population. Less education and lower income were associated with cataract for Chinese and Indians but not Malays. The presence of visual impairment associated with cataract was higher in people aged ≥60 years and Malays. CONCLUSIONS: We showed that people of different Asian ethnicities had a higher prevalence and earlier age of onset of cataract than Europeans. People of Malay ancestry have a greater severity for all cataract subtypes than people of Chinese ancestry. Education and income were associated with cataract for certain Asian subgroups.


Assuntos
Povo Asiático/etnologia , Catarata/etnologia , Etnicidade , Classe Social , Adulto , Idoso , Idoso de 80 Anos ou mais , Austrália/epidemiologia , Catarata/genética , Extração de Catarata/estatística & dados numéricos , Estudos Transversais , Escolaridade , Feminino , Humanos , Renda , Masculino , Pessoa de Meia-Idade , Prevalência , Fatores de Risco , Singapura/epidemiologia , Inquéritos e Questionários , População Branca/etnologia
10.
Ophthalmology ; 121(10): 2013-22, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24950592

RESUMO

PURPOSE: To determine the ethnic differences in the distribution of intraocular pressure (IOP) and central corneal thickness (CCT) in a multi-ethnic Asian population by self-reported ethnicity and genetic ancestry. DESIGN: Population-based, cross-sectional study. PARTICIPANTS: A total of 10 033 adults (3353 Chinese, 3280 Malays, and 3400 Indians) aged >40 years. METHODS: Participants underwent standardized systemic and ocular examinations and interviewer-administered questionnaires for risk factor assessment. The IOP readings were obtained by Goldmann applanation tonometry (Haag-Streit, Konig, Switzerland) before pupil dilation. The CCT was measured with ultrasound pachymetry. Genetic ancestry was derived using principal component (PC) analysis. Regression models were used to investigate the association of IOP and CCT with potential risk factors and genetic ancestry. MAIN OUTCOME MEASURES: Intraocular pressure and CCT. RESULTS: After excluding participants with a history of glaucoma surgery or medication, refractive surgery, corneal edema, or corneal dystrophy, IOP and CCT readings were available for 3251 Chinese, 3232 Malays, and 3317 Indians. The mean IOP readings in the Chinese, Malay, and Indian participants were 14.3±3.1, 15.3±3.7, and 15.8±2.9 mmHg, respectively (P < 0.001). The prevalence of participants with IOP ≥21 mmHg was 2.6% in Chinese, 6.2% in Malays, and 4% in Indians (P < 0.001). In the multivariate regression analysis, the Malay and Indian participants on average had 0.81 and 1.43 mmHg higher IOP levels, respectively, than Chinese (P < 0.001). The mean CCT reading was 552.3±33.4 µm in Chinese, 540.9±33.6 µm in Malays, and 540.4±33.6 µm in Indians (P < 0.001). The percentage of participants with CCT <555 µm was 52.8% in Chinese, 68.5% in Malays, and 66.2% in Indians (P < 0.001). The IOP and CCT levels are significantly correlated with genetic ancestry in our South East Asian population. CONCLUSIONS: Chinese have the thickest CCT but lowest IOP among the 3 major ethnic groups. In addition, there is a higher proportion of Malays with IOP ≥21 mmHg and CCT <555 µm compared with the Chinese or Indians. This disparity across ethnic groups should be taken into account by future studies investigating IOP and CCT as risk factors or diagnostic tests for glaucoma in Asian populations.


Assuntos
Povo Asiático/estatística & dados numéricos , Córnea/anatomia & histologia , Pressão Intraocular/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , China , Estudos Transversais , Feminino , Humanos , Índia , Malásia , Masculino , Pessoa de Meia-Idade , Análise de Regressão
11.
Aust N Z J Obstet Gynaecol ; 54(2): 108-16, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24576045

RESUMO

INTRODUCTION: Cervical length measurement by transvaginal scanning (TVS) has been proposed by some as a universal screening test for preterm labour. The presence of prominent cervical mucous may affect assessment of the cervix; however, the exact technique to measure the cervix when there is prominent mucous or funnelling has not been described. We evaluated the level of agreement in cervical length measurements amongst Australian specialists and sonographers reporting on cervical assessment using an online survey. METHODS: We conducted an online survey with 11 images of the cervix to assess how obstetric sonographers and sonologists report on the cervix when there is prominent mucous or funnelling. They were asked five questions about the image of the cervix. A kappa coefficient was calculated from the responses. RESULTS: We had 151 complete responses to the online survey. For the images which showed funnelling or prominent cervical mucous, there was little agreement regarding the cervix being open or closed and regards the location of the internal os. The Kappa coefficient was 0.22 indicating a low level of agreement for the location of the internal os. CONCLUSION: There is lack of agreement amongst Australian specialists and sonographers reporting on cervical assessment when there is prominent mucous or funnelling seen in the cervix. We propose a method to standardise reporting on the cervix incorporating the chorioamniotic membrane for the identification of the inner cervical os when there is prominent mucous or funnelling.


Assuntos
Medida do Comprimento Cervical , Muco do Colo Uterino/diagnóstico por imagem , Austrália , Colo do Útero/diagnóstico por imagem , Coleta de Dados , Feminino , Humanos , Nova Zelândia , Gravidez
12.
Clin Exp Optom ; 107(2): 110-121, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38266148

RESUMO

The use of optical coherence tomography angiography (OCTA) holds significant promise for optometrists in the diagnosis and management of glaucoma. It offers reliable differentiation of glaucomatous eyes from healthy ones and extends monitoring capabilities for advanced cases. OCTA represents a valuable addition to traditional assessment methods, particularly in complex cases. Glaucoma, a major cause of irreversible blindness, is traditionally diagnosed using structural and functional metrics. With growing interest, OCTA is being explored to diagnose, monitor, and manage glaucoma. This review focuses on the application of OCTA in glaucoma patients. A database search was carried out using Embase Elsevier (n = 664), PubMed (n = 574), and Cochrane Central Register of Controlled Trials (n = 19) on 15 August 2023. After deduplication and screening, 272 original papers were included in the narrative review. Inclusion criteria comprised English-language original studies on OCTA use in human glaucoma patients, with or without healthy controls. Exclusion criteria encompassed animal studies, in-vivo/in-vitro research, reviews, and congress abstracts. OCTA has good repeatability and reproducibility. OCTA metrics have good discriminatory power to differentiate glaucomatous eyes from healthy eyes and show strong associations with structural changes and visual field defects. OCTA can extend the monitoring of advanced glaucoma, addressing the 'floor effect' of traditional structural measurements. OCTA metrics can be affected by the choice of OCTA machine, post-image processing algorithms, systemic diseases, and ocular factors. Image artefacts can affect the accuracy of OCTA measurements, and proper scan quality evaluation is crucial to ensure reliable results. Additionally, artificial intelligence techniques offer promise for enhancing the diagnostic accuracy of OCTA by combining data from various retinal layers and regions. OCTA complements traditional methods in assessing glaucoma, especially in challenging cases, providing valuable insights for detection and management. Further research and clinical validation are needed to integrate OCTA into routine practice.


Assuntos
Glaucoma , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Glaucoma/diagnóstico por imagem , Glaucoma/diagnóstico , Angiofluoresceinografia/métodos , Reprodutibilidade dos Testes , Células Ganglionares da Retina/patologia , Disco Óptico/diagnóstico por imagem , Campos Visuais/fisiologia
13.
Sci Rep ; 14(1): 17909, 2024 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-39095380

RESUMO

The effect of diabetes mellitus (DM) on individual retinal layers remains incompletely understood. We evaluated the intra-retinal layer thickness alterations in 71 DM eyes with no diabetic retinopathy (DR), 90 with mild DR, and 63 with moderate DR without macular edema, using spectral-domain optical coherence tomography (SD-OCT) and the Iowa Reference Algorithm for automated retinal layer segmentation. The average thickness of 10 intra-retinal layers was then corrected for ocular magnification using axial length measurements, and pairwise comparisons were made using multivariable linear regression models adjusted for gender and race. In DM no DR eyes, significant thinning was evident in the ganglion cell layer (GCL; p < 0.001), inner nuclear layer (INL; p = 0.001), and retinal pigment epithelium (RPE; p = 0.014) compared to normal eyes. Additionally, mild DR eyes exhibited a thinner inner plexiform layer (IPL; p = 0.008) than DM no DR eyes. Conversely, moderate DR eyes displayed thickening in the INL, outer nuclear layer, IPL, and retinal nerve fiber layer (all p ≤ 0.002), with notably worse vision. These findings highlight distinctive patterns: early diabetic eyes experience thinning in specific retinal layers, while moderate DR eyes exhibit thickening of certain layers and slightly compromised visual acuity, despite the absence of macular edema. Understanding these structural changes is crucial for comprehending diabetic eye complications.


Assuntos
Retinopatia Diabética , Tomografia de Coerência Óptica , Tomografia de Coerência Óptica/métodos , Humanos , Masculino , Feminino , Retinopatia Diabética/diagnóstico por imagem , Retinopatia Diabética/patologia , Pessoa de Meia-Idade , Idoso , Retina/diagnóstico por imagem , Retina/patologia , Edema Macular/diagnóstico por imagem , Edema Macular/patologia , Macula Lutea/diagnóstico por imagem , Macula Lutea/patologia , Epitélio Pigmentado da Retina/patologia , Epitélio Pigmentado da Retina/diagnóstico por imagem , Células Ganglionares da Retina/patologia
14.
Ann N Y Acad Sci ; 1531(1): 49-59, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38084081

RESUMO

This study aimed to examine the impact of diabetes and hypertension on retinal nerve fiber layer (RNFL) thickness components. Optical coherence tomography (OCT) measurements do not consider blood vessel contribution, which this study addressed. We hypothesized that diabetes and/or hypertension would lead to thinner RNFL versus controls due to the vascular component. OCT angiography was used to measure the RNFL in 121 controls, 50 diabetes patients, 371 hypertension patients, and 177 diabetes patients with hypertension. A novel technique separated the RNFL thickness into original (vascular component) and corrected (no vascular component) measurements. Diabetes-only (98 ± 1.7 µm; p = 0.002) and diabetes with hypertension (99 ± 0.8 µm; p = 0.001) patients had thinner original RNFL versus controls (102 ± 0.8 µm). No difference was seen between hypertension-only patients (101 ± 0.5 µm; p = 0.083) and controls. After removing the blood vessel component, diabetes/hypertension groups had thinner corrected RNFL versus controls (p = 0.024). Discrepancies in diabetes/hypertension patients were due to thicker retinal blood vessels within the RNFL thickness (p = 0.002). Our findings suggest that diabetes and/or hypertension independently contribute to neurodegenerative thinning of the RNFL, even in the absence of retinopathy. The differentiation of neuronal and vascular components in RNFL thickness measurements provided by the novel technique highlights the importance of considering vascular changes in individuals with these conditions.


Assuntos
Diabetes Mellitus , Hipertensão , Doenças Retinianas , Humanos , Células Ganglionares da Retina , Fibras Nervosas , Hipertensão/complicações , Tomografia de Coerência Óptica/métodos
15.
Ann N Y Acad Sci ; 1540(1): 338-349, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39177491

RESUMO

The study aimed to evaluate the impact of compensating retinal nerve fiber layer (RNFL) thickness for demographic and anatomical factors on glaucoma detection in Chinese and Indian adults. A population-based study included 1995 healthy participants (1076 Chinese and 919 Indians) to construct a multivariable linear regression compensation model. This model was applied to 357 Chinese glaucoma patients, 357 healthy Chinese, and 357 healthy Indians using Cirrus spectral-domain optical coherence tomography (OCT). The compensated RNFL thickness considered age, refractive error, optic disc parameters, and retinal vessel density. Results showed that although the average RNFL thickness was significantly higher in Chinese participants compared to Indians, the compensation model reduced this difference to nonsignificance. Moreover, the compensation model significantly improved the area under the receiver operating characteristic curve (0.90 vs. 0.78; p<0.001), sensitivity (75% vs. 51%), and specificity (67% vs. 32%) in distinguishing Chinese glaucoma patients from healthy Indian individuals. The compensation model significantly enhanced the diagnostic accuracy of RNFL thickness in distinguishing glaucoma in the Chinese ethnic group compared to the OCT instrument's default values. These results suggest that modifying RNFL measurements based on individual characteristics can yield substantial benefits for glaucoma detection across ethnicities.


Assuntos
Glaucoma , Fibras Nervosas , Tomografia de Coerência Óptica , Humanos , Glaucoma/diagnóstico , Fibras Nervosas/patologia , Masculino , Feminino , Pessoa de Meia-Idade , Tomografia de Coerência Óptica/métodos , Adulto , Povo Asiático , Retina/diagnóstico por imagem , Retina/patologia , Índia , Idoso , Células Ganglionares da Retina/patologia , China/epidemiologia , Etnicidade
16.
J Pers Med ; 14(8)2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39202025

RESUMO

BACKGROUND: The goal of the present study was to identify differences in retinal microvasculature between healthy Caucasians and healthy Asians in order to provide a better understanding of the variability between different ethnic groups. METHODS: In this cross-sectional study, 191 healthy Chinese and Caucasian participants were enrolled. They underwent optical coherence tomography angiography (OCTA) scans with Zeiss Cirrus HD-5000 Spectral-Domain with AngioPlex. Linear regression models were used to investigate the association of OCTA metrics with potential risk factors. RESULTS: Whereas participants in both groups are comparable in age and sex, Chinese participants had a longer axial length, higher spherical equivalent, higher intraocular pressure (p < 0.001), and a significantly higher perfusion density of large vessels in the superficial capillary plexus (p < 0.001). Regarding the foveolar avascular area (FAZ), Chinese participants had a larger superficial FAZ, a wider superficial FAZ perimeter, and a more circular deep FAZ shape (p < 0.001). CONCLUSIONS: There are significant differences in the retinal vasculature between Caucasian and Asian eyes as measured using OCTA. This needs to be considered when developing normative databases. Whether such findings relate to inter-racial differences in the incidence of retinal vascular disease remains to be shown.

17.
BMJ Open Diabetes Res Care ; 12(1)2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38167606

RESUMO

INTRODUCTION: Diabetic retinopathy (DR) is a leading cause of preventable blindness among working-age adults, primarily driven by ocular microvascular complications from chronic hyperglycemia. Comprehending the complex relationship between microvascular changes in the eye and disease progression poses challenges, traditional methods assuming linear or logistical relationships may not adequately capture the intricate interactions between these changes and disease advances. Hence, the aim of this study was to evaluate the microvascular involvement of diabetes mellitus (DM) and non-proliferative DR with the implementation of non-parametric machine learning methods. RESEARCH DESIGN AND METHODS: We conducted a retrospective cohort study that included optical coherence tomography angiography (OCTA) images collected from a healthy group (196 eyes), a DM no DR group (120 eyes), a mild DR group (71 eyes), and a moderate DR group (66 eyes). We implemented a non-parametric machine learning method for four classification tasks that used parameters extracted from the OCTA images as predictors: DM no DR versus healthy, mild DR versus DM no DR, moderate DR versus mild DR, and any DR versus no DR. SHapley Additive exPlanations values were used to determine the importance of these parameters in the classification. RESULTS: We found large choriocapillaris flow deficits were the most important for healthy versus DM no DR, and became less important in eyes with mild or moderate DR. The superficial microvasculature was important for the healthy versus DM no DR and mild DR versus moderate DR tasks, but not for the DM no DR versus mild DR task-the stage when deep microvasculature plays an important role. Foveal avascular zone metric was in general less affected, but its involvement increased with worsening DR. CONCLUSIONS: The findings from this study provide valuable insights into the microvascular involvement of DM and DR, facilitating the development of early detection methods and intervention strategies.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Adulto , Humanos , Retinopatia Diabética/etiologia , Retinopatia Diabética/diagnóstico , Estudos Retrospectivos , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Microvasos
18.
Transl Vis Sci Technol ; 13(5): 9, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38743409

RESUMO

Purpose: To assess the diagnostic performance and structure-function association of retinal retardance (RR), a customized metric measured by a prototype polarization-sensitive optical coherence tomography (PS-OCT), across various stages of glaucoma. Methods: This cross-sectional pilot study analyzed 170 eyes from 49 healthy individuals and 68 patients with glaucoma. The patients underwent PS-OCT imaging and conventional spectral-domain optical coherence tomography (SD-OCT), as well as visual field (VF) tests. Parameters including RR and retinal nerve fiber layer thickness (RNFLT) were extracted from identical circumpapillary regions of the fundus. Glaucomatous eyes were categorized into early, moderate, or severe stages based on VF mean deviation (MD). The diagnostic performance of RR and RNFLT in discriminating glaucoma from controls was assessed using receiver operating characteristic (ROC) curves. Correlations among VF-MD, RR, and RNFLT were evaluated and compared within different groups of disease severity. Results: The diagnostic performance of both RR and RNFLT was comparable for glaucoma detection (RR AUC = 0.98, RNFLT AUC = 0.97; P = 0.553). RR showed better structure-function association with VF-MD than RNFLT (RR VF-MD = 0.68, RNFLT VF-MD = 0.58; z = 1.99; P = 0.047) in glaucoma cases, especially in severe glaucoma, where the correlation between VF-MD and RR (r = 0.73) was significantly stronger than with RNFLT (r = 0.43, z = 1.96, P = 0.050). In eyes with early and moderate glaucoma, the structure-function association was similar when using RNFLT and RR. Conclusions: RR and RNFLT have similar performance in glaucoma diagnosis. However, in patients with glaucoma especially severe glaucoma, RR showed a stronger correlation with VF test results. Further research is needed to validate RR as an indicator for severe glaucoma evaluation and to explore the benefits of using PS-OCT in clinical practice. Translational Relevance: We demonstrated that PS-OCT has the potential to evaluate the status of RNFL structural damage in eyes with severe glaucoma, which is currently challenging in clinics.


Assuntos
Glaucoma , Fibras Nervosas , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Campos Visuais , Humanos , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Masculino , Feminino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Projetos Piloto , Campos Visuais/fisiologia , Glaucoma/fisiopatologia , Glaucoma/diagnóstico por imagem , Idoso , Células Ganglionares da Retina/patologia , Curva ROC , Testes de Campo Visual/métodos , Adulto , Pressão Intraocular/fisiologia
19.
Br J Ophthalmol ; 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38719343

RESUMO

BACKGROUND/AIMS: To investigate whether compensating retinal nerve fibre layer (RNFL) thickness measurements for demographic and anatomical ocular factors can strengthen the structure-function relationship in patients with glaucoma. METHODS: 600 eyes from 412 patients with glaucoma (mean deviation of the visual field (MD VF) -6.53±5.55 dB) were included in this cross-sectional study. Participants underwent standard automated perimetry and spectral-domain optical coherence tomography imaging (Cirrus; Carl Zeiss Meditec). Compensated RNFL thickness was computed considering age, refractive error, optic disc parameters and retinal vessel density. The relationship between MD VF and RNFL thickness measurements, with or without demographic and anatomical compensation, was evaluated sectorally and focally. RESULTS: The superior arcuate sector exhibited the highest correlation between measured RNFL and MD VF, with a correlation of 0.49 (95% CI 0.37 to 0.59). Applying the compensated RNFL data increased the correlation substantially to 0.62 (95% CI 0.52 to 0.70; p<0.001). Only 61% of the VF locations showed a significant relationship (Spearman's correlation of at least 0.30) between structural and functional aspects using measured RNFL data, and this increased to 78% with compensated RNFL measurements. In the 10°-20° VF region, the slope below the breakpoint for compensated RNFL thickness demonstrated a more robust correlation (slope=1.66±0.18 µm/dB; p<0.001) than measured RNFL (slope=0.27±0.67 µm/dB; p=0.688). CONCLUSION: Compensated RNFL data improve the correlation between RNFL measurements and VF parameters. This indicates that creating structure-to-function maps that consider anatomical variances may aid in identifying localised structural and functional loss in glaucoma.

20.
Transl Vis Sci Technol ; 13(1): 5, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38197730

RESUMO

Purpose: We wanted to develop a deep-learning algorithm to automatically segment optic nerve head (ONH) and macula structures in three-dimensional (3D) wide-field optical coherence tomography (OCT) scans and to assess whether 3D ONH or macula structures (or a combination of both) provide the best diagnostic power for glaucoma. Methods: A cross-sectional comparative study was performed using 319 OCT scans of glaucoma eyes and 298 scans of nonglaucoma eyes. Scans were compensated to improve deep-tissue visibility. We developed a deep-learning algorithm to automatically label major tissue structures, trained with 270 manually annotated B-scans. The performance was assessed using the Dice coefficient (DC). A glaucoma classification algorithm (3D-CNN) was then designed using 500 OCT volumes and corresponding automatically segmented labels. This algorithm was trained and tested on three datasets: cropped scans of macular tissues, those of ONH tissues, and wide-field scans. The classification performance for each dataset was reported using the area under the curve (AUC). Results: Our segmentation algorithm achieved a DC of 0.94 ± 0.003. The classification algorithm was best able to diagnose glaucoma using wide-field scans, followed by ONH scans, and finally macula scans, with AUCs of 0.99 ± 0.01, 0.93 ± 0.06 and 0.91 ± 0.11, respectively. Conclusions: This study showed that wide-field OCT may allow for significantly improved glaucoma diagnosis over typical OCTs of the ONH or macula. Translational Relevance: This could lead to mainstream clinical adoption of 3D wide-field OCT scan technology.


Assuntos
Glaucoma , Disco Óptico , Humanos , Disco Óptico/diagnóstico por imagem , Inteligência Artificial , Tomografia de Coerência Óptica , Estudos Transversais , Glaucoma/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA