RESUMO
BACKGROUND: Despite the use of two crossed Perclose ProGlide™ (Abbott Vascular Devices) is the most widespread technique to close the main arterial access in transfemoral transcatheter aortic valve implantation (TF-TAVI), the safest and most effective strategy still remains much debated. AIMS: The aim of the present study was to evaluate the performance of a single Perclose ProGlide suture-mediated closure device to obtain femoral hemostasis after sheathless implantation of self-expanding transcatheter heart valves through their 14 F-equivalent fix delivery systems. METHODS: This prospective observational study included 439 patients undergoing TF-TAVI at the "Montevergine" Clinic of Mercogliano, Italy. All patients underwent hemostasis of the large-bore access using a single Perclose ProGlide with preclose technique, after sheathless implantation of self-expanding transcatheter heart valves through 14 F-equivalent fix delivery systems. A multidetector computed tomography analysis of size, tortuosity, atherosclerotic, and calcification burdens of the ilio-femoral access route was made by a dedicated corelab. Vascular complications (VCs), percutaneous closure device (PCD) failure, and bleedings were adjudicated by a clinical events committee. RESULTS: A total of 81 different VCs were observed in 60 patients (13.7%); among these, 41 (5% of patients) were categorized as major. PCD failure occurred in 14 patients (3.2%). At the logistic regression analysis, no predictors of PCD failure have been identified. CONCLUSION: This registry suggests that the use of a single suture-mediated closure device could be considered a safe and efficient technique to achieve access site hemostasis in patients undergoing TF-TAVI through 14 F-equivalent fix delivery systems.
Assuntos
Cateterismo Periférico , Artéria Femoral , Técnicas Hemostáticas , Punções , Técnicas de Sutura , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Humanos , Artéria Femoral/diagnóstico por imagem , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Prospectivos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Cateterismo Periférico/efeitos adversos , Idoso , Técnicas Hemostáticas/instrumentação , Técnicas Hemostáticas/efeitos adversos , Técnicas de Sutura/efeitos adversos , Técnicas de Sutura/instrumentação , Fatores de Risco , Fatores de Tempo , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Itália , Desenho de Equipamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Hemorragia/etiologia , Hemorragia/prevenção & controleRESUMO
L-Arginine (L-Arg), is a semi-essential amino acid involved in the formation of nitric oxide. The functional relevance of L-Arg in diabetes mellitus has been evaluated both in animal models and in human subjects. In the literature there are several lines of evidence indicating that L-Arg has beneficial effects in diabetes and numerous studies advocate its administration to attenuate glucose intolerance in diabetic patients. Here we present a comprehensive overview of the main studies exploring the effects of L-Arg in diabetes, including preclinical and clinical reports on this topic.
Assuntos
Diabetes Mellitus , Intolerância à Glucose , Animais , Humanos , Arginina/metabolismo , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/tratamento farmacológico , Óxido Nítrico/metabolismoRESUMO
PURPOSE: The aim of this study was to assess the efficacy and safety of the novel SLR (SELUTION sustained-limus-release) drug-coated balloon (DCB) in the treatment of the femoropopliteal steno-occlusive disease. MATERIALS AND METHODS: From February 2021 to March 2022, 80 consecutive patients (age: 69.5±8.23 years; total number of lesions: 80) with a steno-occlusive lesion of superficial femoral artery were enrolled at our center. A total of 60 patients (75%) had claudication, whereas 20 (25%) had chronic limb-threatening ischemia (CLTI). The mean lesion length was 171±82.22 mm. The primary efficacy outcome was primary patency at 12 months, defined as freedom from restenosis determined by a duplex ultrasound peak systolic velocity ratio ≤2.4. The secondary efficacy outcome was freedom from clinically-driven target lesion revascularization (CD-TLR) at 12 months. The primary safety outcome was a composite of freedom from device- and procedure-related mortality, major target limb amputation, and clinically-driven target lesion urgent revascularization (endovascular or bypass graft) at 30 days and 12 months. RESULTS: Device success was achieved in all 80 patients. One death on day 7 from cardiovascular complications was ruled procedure-related because it occurred within the first 30 days from the discharge. Two patients with CLTI experienced planned minor amputations of target limb, and one patient underwent urgent bypass graft of the target vessel for early occlusion at 60 days from the index procedure. The primary safety outcome was 98.7% and 97.5% at 30 days and 12 months, respectively. At 1 year, primary patency was 86.3%, and freedom from CD-TLR was 96.2%. CONCLUSION: These findings suggest that using a novel sirolimus-coated balloon is a safe and effective treatment option for femoropopliteal steno-occlusive lesions in a variety of clinical and anatomical settings. These results will need to be confirmed by long-term follow-up and randomized controlled trials. CLINICAL IMPACT: In femoropopliteal steno-occlusive lesions paclitaxel drug-coated devices have been proved to be able to achieve a better vessel patency during follow-up compared with uncoated balloon, but according to a recent meta-analysis they may carry an elevated risk of late mortality. Sirolimus results in a wider therapeutic range with a 3-fold higher margin of safety. Sirolimus coated devices have recently been proposed as an alternative. This study suggests that using a novel sirolimus-coated balloon is a safe and effective treatment option for femoropopliteal steno-occlusive lesions.
RESUMO
BACKGROUND: Aortic valve stenosis (AS) is the most common valvular heart disease worldwide. When timely intervention is performed, aortic valve replacement can improve patients' quality and duration of life. Load-independent left ventricular (LV) functional assessments, such as myocardial work indices (MWIs) and LV diastolic function parameters, could help clinicians decide on the optimal timing of intervention. AIMS: To evaluate the reliability of MWI in AS patients and the changes in MWI and LV diastolic function after transcatheter aortic valve replacement (TAVR). METHODS: We enrolled 53 consecutive patients with severe AS undergoing TAVR admitted between March 2021 and November 2021. MWIs and LV diastolic function were assessed before and after TAVR for each patient. RESULTS: All MWIs and LV diastolic function indices improved after TAVR. The degree of MWIs improvement was higher in patients with lower prior-TAVR MWI values, while the more severe the impairment of diastolic function, the greater the post-TAVR benefit. CONCLUSION: The introduction of myocardial work parameters into the routine assessment of patients with AS could improve our understanding of cardiac performance and aid in identifying the optimal timing for surgical or percutaneous treatment.
Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Reprodutibilidade dos Testes , Resultado do Tratamento , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Função Ventricular Esquerda , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Índice de Gravidade de Doença , Estudos RetrospectivosRESUMO
BACKGROUND: Endarterectomy is considered the gold standard therapy for common femoral artery (CFA) steno-occlusive lesions, but a significant risk of perioperative mortality and complications has been reported. OBJECTIVE: Aim of this study is to evaluate the efficacy at a long-term follow-up of patients with CFA steno-occlusive lesions treated with directional atherectomy and drug coated balloon (DCB). MATERIAL AND METHODS: In this single-center registry, 78 patients (male: 80.7%; age: 71 ± 15 years; occlusions: 25%) with 80 CFA lesions were included, with 39.7% of them undergoing directional atherectomy and drug coated balloon due to critical limb ischemia and 60.3% due to lower-limb intermittent claudication. The long-term follow-up was completed by 75 patients (3 years). The 31 patients with critical ischemia (39.7%) were further subdivided into 20 (25.6%) patients with pain at rest and 11 (14.1%) with trophic changes, ulcers and/or tissue loss. We considered the primary and the secondary outcome, referring, respectively to peak systolic velocity ratio (PSVR) ≥ 2.4 on duplex or > 50% stenosis on digital subtraction angiography at 36 months and to clinically driven target lesion revascularization at 36 months. RESULTS: The primary and secondary outcome was obtained in 84% and 86.7% of patients, at 36 months of follow up. Bailout stenting was necessary in 6/80 cases (7.5%) for suboptimal result. Freedom from MALE was obtained in 98.6% of patients. CONCLUSIONS: These results confirm that directional atherectomy and drug coated balloon strategy for the treatment of CFA lesions is effective at a long-term follow-up and could be considered as a good alternative to surgery.
Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/efeitos adversos , Aterectomia/efeitos adversos , Materiais Revestidos Biocompatíveis , Artéria Femoral , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Artéria Poplítea , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução VascularRESUMO
Performing transcatheter aortic valve implantation with high implantation technique, i.e. with an aorto-ventricular ratio > 60/40, reduces the need of permanent pacemaker implantation. Valve calcification and prosthesis oversizing are predictors of permanent pacemaker implantation, but there are no available data on their role when transcatheter aortic valve implantation is performed with an aorto-ventricular ratio > 60/40. The aim of this study was to evaluate the effect of leaflets/annulus calcification and prosthesis oversizing on the incidence of permanent pacemaker implantation after transcatheter aortic valve implantation with a high implantation technique. Transcatheter aortic valve implantation was performed in 48 patients implanting a balloon-expandable transcatheter heart valve with an aorto-ventricular ratio > 60/40. Calcium burden was assessed by preprocedural multidetector computed tomography. An invasive electrophysiological study was performed before and after transcatheter aortic valve implantation. Five patients (10.4%) needed permanent pacemaker implantation. At univariate analysis, baseline right bundle branch block and postprocedural PR, QRS and His-ventricular interval elongation significantly predicted permanent pacemaker implantation (p < 0.05). Receiver-operating characteristic curve analysis showed a correlation between transcatheter heart valve oversizing and permanent pacemaker implantation need, with the best cut-off being 17% (AUC = 0.72, p = 0.033). Linear regression analysis demonstrated that QRS complex elongation was related to total, left and non-coronary leaflet calcification (p < 0.05). This study demonstrates that, when transcatheter aortic valve implantation is performed using a balloon-expandable transcatheter heart valve deployed with an aorto-ventricular ratio > 60/40, the presence of leaflets/annulus calcification or the need to oversize the prosthesis correlate with the occurrence of pathological cardiac conduction delays.
Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do TratamentoRESUMO
The expansion of coronavirus disease 2019 (COVID-19) prompted measures of disease containment by the Italian government with a national lockdown on March 9, 2020. The purpose of this study is to evaluate the rate of hospitalization and mode of in-hospital treatment of patients with chronic limb-threatening ischemia (CLTI) before and during lockdown in the Campania region of Italy. The study population includes all patients with CLTI hospitalized in Campania over a 10-week period: 5 weeks before and 5 weeks during lockdown (n = 453). Patients were treated medically and/or underwent urgent revascularization and/or major amputation of the lower extremities. Mean age was 69.2 ± 10.6 years and 27.6% of the patients were women. During hospitalization, 21.9% of patients were treated medically, 78.1% underwent revascularization, and 17.4% required amputations. In the weeks during the lockdown, a reduced rate of hospitalization for CLTI was observed compared with the weeks before lockdown (25 vs 74/100,000 inhabitants/year; incidence rate ratio: 0.34, 95% CI 0.32-0.37). This effect persisted to the end of the study period. An increased amputation rate in the weeks during lockdown was observed (29.3% vs 13.4%; p < 0.001). This study reports a reduced rate of CLTI-related hospitalization and an increased in-hospital amputation rate during lockdown in Campania. Ensuring appropriate treatment for patients with CLTI should be prioritized, even during disease containment measures due to the COVID-19 pandemic or other similar conditions.
Assuntos
COVID-19/epidemiologia , COVID-19/virologia , Extremidades/fisiopatologia , Hospitalização/estatística & dados numéricos , Isquemia/epidemiologia , SARS-CoV-2/patogenicidade , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença Crônica , Estudos Transversais , Feminino , Humanos , Isquemia/fisiopatologia , Isquemia/virologia , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/complicações , Doença Arterial Periférica/virologia , Estudos Retrospectivos , Fatores de RiscoRESUMO
Significant paravalvular leak regurgitation (PVLR) after transcatheter aortic valve replacement (TAVR) is a well-known complication associated with disabling symptoms related to heart failure and hemolysis or both, with poor prognostic implications. Although challenging and technically demanding, percutaneous closure is an effective treatment option for high-risk patients with symptomatic PVLR. Here, we present two cases of transcatheter PVLR closure after replacement of third-generation (one self-expandable and one balloon-expandable) transcatheter aortic valves, each with peculiar challenges, and the strategies adopted to increase the success rate of percutaneous closure.
Assuntos
Insuficiência da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/instrumentação , Angioplastia com Balão/métodos , Insuficiência da Valva Aórtica/etiologia , Cateterismo Cardíaco/instrumentação , Feminino , Humanos , MasculinoRESUMO
Aims: Preliminary data on Sapien 3 valve (S3-THV) use for transcatheter aortic valve implantation have shown an increased permanent pacemaker implantation (PPMI) rate with respect to Sapien XT valve. Aim of this study was to investigate the role of S3-THV position in the left ventricular outflow tract (LVOT) on electrocardiographic changes suggestive of atrioventricular (ΔPR) and/or intraventricular (ΔQRS) conduction abnormalities and 30 days PPMI rate. Methods and results: Eighty-six consecutive patients treated with S3-THV were included in the study. All patients underwent clinical and electrocardiogram evaluation. Left ventricular outflow tract prosthesis depth was assessed by fluoroscopy and expressed quantitatively (mm) and as aorto-ventricular ratio (AVR). Eight patients (9.3%) needed PPMI at 30 days. A low AVR (≤60/40) predicted PPMI (OR = 6.09, 95% CI 1.19-31.01, P = 0.030) and resulted into higher PPMI rate, compared with higher AVR (30.0 vs. 6.6%, P = 0.017). For each millimetre increase in the LVOT prosthesis depth PPMI risk increased by 1.41 times (95% CI 1.06-1.87, P = 0.017). In patients with low AVR, ΔPR was higher than in those with higher AVR (33.4 ± 56.7 vs. 12.1 ± 19.4 ms, P = 0.021) and ΔPR was associated to LVOT prosthesis depth (ß = 0.286, P = 0.009). Furthermore, ΔPR was associated with risk of PPMI (OR = 1.03, 95% CI 1.01-1.06, P = 0.024). Conclusions: A low AVR is associated to higher ΔPR and PPMI rates. The correlation between LVOT prosthesis depth with ΔPR and higher PPMI rate suggests the need of a careful S3-THV implantation.
Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/transplante , Arritmias Cardíacas/etiologia , Valvuloplastia com Balão/efeitos adversos , Frequência Cardíaca , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Distribuição de Qui-Quadrado , Eletrocardiografia , Feminino , Humanos , Itália , Modelos Lineares , Modelos Logísticos , Masculino , Análise Multivariada , Razão de Chances , Marca-Passo Artificial , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do TratamentoRESUMO
BACKGROUND: Through contemporary literature, the optimal strategy to manage coronary chronic total occlusions (CTOs) remains under debate. OBJECTIVES: The aim of the Italian Registry of Chronic Total Occlusions (IRCTO) was to provide data on prevalence, characteristics, and outcome of CTO patients according to the management strategy. METHODS: The IRCTO is a prospective real world multicentre registry enrolling patients showing at least one CTO. Clinical and angiographic data were collected independently from the therapeutic strategy [optimal medical therapy (MT), percutaneous coronary intervention (PCI), or coronary artery bypass grafting (CABG)]; a comparative 1-year clinical follow-up was performed. RESULTS: A total of 1777 patients were enrolled for an overall CTO prevalence of 13.3%. The adopted therapeutic strategies were as follows: MT in 826 patients (46.5%), PCI in 776 patients (43.7%), and CABG in the remaining 175 patients (9.8%). At 1-year follow-up, patients undergoing PCI showed lower rate of major adverse cardiac and cerebrovascular events (MACCE) (2.6% vs. 8.2% and vs. 6.9%; P < 0.001 and P < 0.01) and cardiac death (1.4% vs. 4.7% and vs. 6.3%; P < 0.001 and P < 0.001) in comparison with those treated with MT and CABG, respectively. After propensity score-matching analysis, patients treated with PCI showed lower incidence of cardiac death (1.5 vs. 4.4%; P < 0.001), acute myocardial infarction (1.1 vs. 2.9%; P = 0.03), and re-hospitalization (2.3 vs. 4.4% P = 0.04) in comparison with those managed by MT. CONCLUSIONS: Our data showed how CTO PCI might significantly improve the survival and decrease MACCE occurrence at 1 year follow-up in comparison with MT and/or CABG.
Assuntos
Oclusão Coronária/terapia , Idoso , Fármacos Cardiovasculares/uso terapêutico , Doença Crônica , Angiografia Coronária/mortalidade , Ponte de Artéria Coronária/mortalidade , Ponte de Artéria Coronária/estatística & dados numéricos , Oclusão Coronária/mortalidade , Feminino , Humanos , Itália/epidemiologia , Masculino , Intervenção Coronária Percutânea/mortalidade , Intervenção Coronária Percutânea/estatística & dados numéricos , Prevalência , Estudos Prospectivos , Sistema de Registros , Resultado do Tratamento , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/terapiaRESUMO
The interventional treatment of coronary artery disease (CAD) has undergone significant improvements thanks to technological innovations. Nowadays, percutaneous coronary intervention (PCI) with drug-eluting stent (DES) implantation is the standard of care for the treatment of CAD. Nevertheless, the non-negligible incidence of in-stent restenosis (ISR) and suboptimal results in various anatomical settings has led to the development of drug-coated balloons (DCBs). DCBs are catheter-based balloons whose surface is coated with an anti-proliferative drug (mainly Paclitaxel or Sirolimus) loaded onto the balloon surface with different technologies and dose concentrations. In the beginning, these devices were used for the treatment of ISR showing an excellent efficacy profile in the inhibition of intimal hyperplasia. Subsequently, several studies evaluated their use in other angiographical and clinical contexts such as de novo lesions, small vessel disease, diffuse coronary disease, bifurcation lesions, acute coronary syndromes, high-bleeding risk and diabetic patients. This comprehensive review aims to describe the main DCB platforms on the market, their fields of application with the main supporting studies and their future perspectives.
RESUMO
Over the last few decades, endovascular revascularization techniques have revolutionized the treatment of peripheral artery disease, offering a less invasive alternative to surgery. However, the successful treatment of heavily calcified lesions is often compromised by various vascular complications, including recoils, dissections, and the need for target vessel reinterventions. This has prompted the development of several tools for lesion preparation, with the aim of achieving better procedural outcomes. This review aims to summarize the main characteristics and current evidence related to the available devices for preparing severely calcified peripheral lesions.
Assuntos
Procedimentos Endovasculares , Doença Arterial Periférica , Calcificação Vascular , Humanos , Procedimentos Endovasculares/métodos , Doença Arterial Periférica/terapia , Doença Arterial Periférica/cirurgia , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia , Índice de Gravidade de DoençaRESUMO
Aims Invasive cardiologists are the most exposed to ionizing radiation among health professionals and show an increased rate of somatic DNA damage. To evaluate the effects of chronic low-dose exposure to ionizing radiation on redox state and apoptotic activation. Methods and results We enrolled 10 healthy exposed professionals (all interventional cardiologists, Group II, exposed: age = 38 ± 5 years) and 10 age- and gender-matched unexposed controls (Group I, non-exposed). Exposed subjects had a median exposure of 4 mSv/year (range 1-8) by film badge dosimetry (below lead apron). We measured reduced glutathione (GSH, a marker of antioxidant response) in erythrocytes and plasma generation of hydrogen peroxide (a marker of oxyradical stress) by ferrous oxidation-xylenol orange assay in plasma. In both groups, lymphocytes were isolated and caspase-3 activity (a marker of apoptotic response) measured at baseline and following 2 Gy in vitro irradiation. Exposed subjects showed a three-fold increase in hydrogen peroxide (Group I = 2.21 ± 1.03 vs. II = 6.51 ± 1.55 µM H(2)O(2) equivalents) and a 1.7-fold increase in GSH (I = 12.37 ± 1.22 vs. II = 20.61 ± 2.16 mM). Exposed subjects also showed higher values of caspase-3 activity, both at baseline and-more strikingly-following high-dose radiation challenge. Conclusion In interventional cardiologists, chronic exposure to low-dose radiation is associated with an altered redox balance mirrored by an increase in hydrogen peroxide and with two possibly adaptive cellular responses: (i) an enhanced antioxidant defence (increase in GSH, counteracting increased oxyradical stress) and (ii) an increased susceptibility to apoptotic induction which might efficiently remove genetically damaged cells.
Assuntos
Apoptose/efeitos da radiação , Cardiologia , Exposição Ocupacional/efeitos adversos , Oxirredução/efeitos da radiação , Radiação Ionizante , Adulto , Antioxidantes/metabolismo , Biomarcadores/metabolismo , Estudos de Casos e Controles , Caspase 3/metabolismo , Eritrócitos/química , Eritrócitos/efeitos da radiação , Glutationa/metabolismo , Humanos , Masculino , Doses de Radiação , Espécies Reativas de Oxigênio/metabolismoRESUMO
Carotid artery stenting (CAS) is usually performed through a femoral vascular access using 6-9 Fr guiding catheters. We investigated whether a systematic distal radial approach using 5 Fr guiding sheaths was a safe and effective alternative to transfemoral approach for CAS. From July 2020 to October 2022, two operators at our center systematically performed CAS using a 5 Fr distal radial approach in consecutive patients. The main endpoints of the study were procedural success via distal radial and via proximal or distal radial access. The learning curve was evaluated by comparing the first half of patients versus the second half of patients enrolled. Procedural data and 30-day clinical outcomes were collected. Fifty-one patients were prospectively enrolled. CAS was effectively performed via distal radial access in 45 patients (88%). Overall radial artery success was 92%. Distal radial CAS was successfully performed in 20 out of the first 25 patients enrolled (80%), and in 25 of the last 26 patients enrolled (96%; p = 0.07). Significantly less contrast was administered in the last 26 patients compared to the first 25 enrolled (110 (70, 140) mL vs. 120 (107, 150) mL; p = 0.045). Radial artery occlusion was reported in 1 patient (2%). Only 1 minor stroke (2%) was reported in-hospital and at 30-day follow-up. In conclusion, distal radial CAS using 5 Fr catheters was a safe procedure with a high success rate. The procedure had a relatively short learning curve in operators familiar with transfemoral CAS.
RESUMO
BACKGROUND: Acute kidney injury (AKI) after transcatheter aortic valve implantation (TAVI) is a frequent complication associated with adverse outcomes and mortality. Various scores have been developed to predict this complication in the coronary setting. However, none have ever been tested in a large TAVI population. This study aimed to evaluate the power of four different scores in predicting AKI after TAVI. METHODS: Overall, 1535 consecutive TAVI patients from the observational multicentric "Magna Graecia" TAVI registry were included in the analysis. Of the study population, 235 (15.31%) developed AKI early. The Mehran, William Beaumont Hospital, CR4EATME3AD3, and ACEF scores were calculated retrospectively. RESULTS: The patients who developed TAVI-related AKI had significantly higher absolute values of all risk scores than those who did not. The receiver-operating characteristic analysis also showed a significant correlation between these four scores and AKI, but without a significant difference among all of them (p value = 0.176). Nevertheless, based on their area under the curve values (≤0.604 for all), none had adequate diagnostic accuracy in predicting TAVI-related AKI. Importantly, multivariate analysis identified myocardial revascularization close to the TAVI procedure and implantation of self-expanding prostheses, as well as atrial fibrillation, low-osmolar contrast media administration, corrected contrast medium volume, and any transfusion (p value < 0.05 for all) as independent risk factors for AKI. CONCLUSIONS: Although high values of current AKI risk scores are significantly associated with the development of this complication, these are not sufficiently accurate. Further studies are needed so that a TAVI-dedicated AKI risk score may be created.
Assuntos
Injúria Renal Aguda , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodosRESUMO
OBJECTIVE: Ischemia with nonobstructive coronary arteries (INOCA) is a prevailing finding in patients with angina. However, the main factors underlying the risk of being rehospitalized for chest pain in patients with INOCA remain mostly unknown. RESEARCH DESIGN AND METHODS: We evaluated INOCA patients referred to the "Casa di Cura Montevergine" in Mercogliano (Avellino), Italy, from January 2016 to January 2021 for percutaneous coronary intervention (PCI). In these subjects, we assessed the impact of the stress hyperglycemia ratio (SHR), defined as the ratio of mmol/L blood glucose and % HbA1c, on the risk of rehospitalization for chest pain. RESULTS: A total of 2,874 patients with INOCA successfully completed the study. At the 1-year follow-up, the risk of rehospitalization for chest pain was significantly higher (P < 0.001) in INOCA patients with SHR >1 compared to patients with SHR ≤1. These findings were confirmed by multivariable analyses (adjusting for potential confounders, including age, BMI, blood pressure, heart rate, chronic kidney disease, and cholesterol), propensity score matching, and inverse probability of treatment weighting. CONCLUSIONS: Our data indicate, to our knowledge for the first time, that SHR on hospital admission significantly and independently increases the risk of rehospitalization for chest pain in INOCA patients.
Assuntos
Doença da Artéria Coronariana , Hiperglicemia , Intervenção Coronária Percutânea , Humanos , Vasos Coronários , Hospitalização , Dor no Peito/etiologia , Isquemia , Doença da Artéria Coronariana/complicaçõesRESUMO
BACKGROUND: The primary patency rate of superficial femoral artery (SFA) after percutaneous transluminal angioplasty (PTA) has improved with the use of self-expanding stents. However, occurrence of in-stent restenosis (ISR) still represents a frequent problem. Despite different studies have assessed the role of atherectomy and drug coated balloons (DCBs), no long-term data exist about combined use. The aim of this study was to evaluate safety and efficacy of combined treatment with Jetstream (Boston Scientific Corp., Marlborough, MA, USA) atherectomy and DCB for SFA intrastent restenosis (ISR) at 2-year follow-up. METHODS: 30 patients treated with PTA from November 2018 to September 2019 at Montevergine Clinic (Mercogliano, Avellino, Italy) were included in this analysis. All patients underwent PTA of SFA-ISR with Jetstream Atherectomy System followed by paclitaxel eluting balloon treatment. Patients were evaluated at 30 days, and every 3 months up to 24. RESULTS: Technical and procedural success was achieved in every patient. No in-hospital major adverse cardiac and cerebrovascular events occurred. No acute and sub-acute(in-hospital) procedure related complications occurred. During follow-up, 1 patient died due to stroke. Primary patency rate at 12 months was 93.4%. Primary patency rate at 24 months was 83.4%. Secondary patency rate at 24 months was 96.7%. One minor amputation, planned before treatment, was performed in the first 30 days. CONCLUSIONS: Our data suggest that combined therapy with Rotational Atherectomy and DCBs for SFA-ISR represents a safe and effective procedure with a high rate of primary patency at 2-year follow-up.
Assuntos
Angioplastia com Balão , Aterectomia Coronária , Reestenose Coronária , Doença Arterial Periférica , Humanos , Artéria Femoral/cirurgia , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/métodos , Reestenose Coronária/etiologia , Resultado do Tratamento , Doença Arterial Periférica/terapiaRESUMO
BACKGROUND: Cardiac fibrosis represents a key element in the pathophysiology of heart failure with preserved ejection fraction (HFpEF), a condition highly prevalent amongst geriatric patients, especially if diabetic. The microRNA 181c (miR-181c) has been shown to be associated with the response to exercise training in HFpEF patients and has been also linked to diabetic cardiovascular complications. However, the underlying mechanisms have not been fully elucidated. OBJECTIVE: To measure circulating miR-181c in elderly patients with HFpEF and diabetes mellitus (DM) and identify gene targets pathophysiologically relevant in HFpEF. METHODS: We quantified circulating miR-181c in frail older adults with a confirmed diagnosis of HFpEF and DM, and, as control, we enrolled age-matched subjects without HFpEF and without DM. We validated in human cardiac fibroblasts the molecular mechanisms linking miR-181c to a pro-fibrotic response. RESULTS: 51 frail patients were included :34 patients with DM and HFpEF and 17 age-matched controls. We observed that miR-181c was significantly upregulated (p < 0.0001) in HFpEF patients vs controls. We confirmed in vitro that miR-181c is targeting PRKN and SMAD7. CONCLUSIONS: We demonstrate that miR-181c levels are significantly increased in frail elderly adults with DM and HFpEF and that miR-181c targets PRKN and SMAD7 in human cardiac fibroblasts.
Assuntos
Diabetes Mellitus , Insuficiência Cardíaca , MicroRNAs , Humanos , Idoso , Insuficiência Cardíaca/genética , Insuficiência Cardíaca/metabolismo , Volume Sistólico/fisiologia , Fibrose , MicroRNAs/genética , MicroRNAs/metabolismo , Fibroblastos/metabolismo , Ubiquitina-Proteína Ligases/metabolismo , Proteína Smad7/genética , Proteína Smad7/metabolismoRESUMO
BACKGROUND: Surgical mortality risk scores, even if not properly designed and rarely tested in the transcatheter aortic valve implantation (TAVI) setting, still guide the heart team in managing significant aortic stenosis. METHODS: After splitting 1763 consecutive patients retrospectively based on their mortality risk thresholds, the composite endpoint early safety (ES) was adjudicated according to Valve Academic Research Consortium (VARC)-2 and -3 consensus documents. RESULTS: ES incidence was higher if VARC-2 rather than VARC-3 defined. Despite only patients showing VARC-2 ES had significantly lower absolute values of all three main risk scores, these last still failed to foresee both VARC-2 and -3 ES in intermediate-risk patients. The receiver operating characteristic analysis also showed a significant correlation, but with poor diagnostic accuracy, among the three scores and only VARC-2 ES; moreover, the absence of VARC-2 ES and low-osmolar contrast media administration were identified as independent predictors of 1-year mortality and absence of VARC-3 ES, respectively. Finally, even a single complication included in the ES definition could significantly affect 1-year mortality. CONCLUSION: Currently, the most used mortality risk scores do not have adequate diagnostic accuracy in predicting ES after TAVI. The absence of VARC-2, instead of VARC-3, ES is an independent predictor of 1-year mortality.