Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Aerosol Sci ; 166: 106052, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35935165

RESUMO

In the wake of the COVID-19 pandemic, interest in understanding the turbulent dispersion of airborne pathogen-laden particles has significantly increased. The ability of infectious particles to stay afloat and disperse in indoor environments depends on their size, the environmental conditions and the hydrodynamics of the flow generated by the exhalation. In this work we analyze the impact of three different aspects, namely, the buoyancy force, the upper airways geometry and the head rotation during the exhalation on the short-term dispersion. Large-Eddy Simulations have been used to assess the impact of each separate effect on the thermal puff and particle cloud evolution over the first 2 s after the onset of the exhalation. Results obtained during this short-term period suggest that due to the rapid mixing of the turbulent puff, buoyancy forces play a moderate role on the ability of the particles to disperse. Because of the enhanced mixing, buoyancy reduces the range and increases the vertical size of the small particle clouds. In comparison to the fixed frame case, head rotation has been found to notably affect the size and shape of the cloud by enhancing the vertical transport as the exhalation axial direction sweeps vertically during the exhalation. The impact of the upper airway geometry, in comparison to an idealized mouth consisting in a pipe of circular section, has been found to be the largest when it is considered along with the head rotation.

2.
Nano Lett ; 17(2): 606-614, 2017 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-28060521

RESUMO

Although a number of techniques exist for generating structured organic nanocomposites, it is still challenging to fabricate them in a controllable, yet universal and scalable manner. In this work, a microfluidic platform, exploiting superfast (milliseconds) time intervals between sequential nanoprecipitation processes, has been developed for high-throughput production of structured core/shell nanocomposites. The extremely short time interval between the sequential nanoprecipitation processes, facilitated by the multiplexed microfluidic design, allows us to solve the instability issues of nanocomposite cores without using any stabilizers. Beyond high throughput production rate (∼700 g/day on a single device), the generated core/shell nanocomposites harness the inherent ultrahigh drug loading degree and enhanced payload dissolution kinetics of drug nanocrystals and the controlled drug release from polymer-based nanoparticles.

3.
J Biomech Eng ; 137(12): 121008, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26473395

RESUMO

With the increased availability of computational resources, the past decade has seen a rise in the use of computational fluid dynamics (CFD) for medical applications. There has been an increase in the application of CFD to attempt to predict the rupture of intracranial aneurysms, however, while many hemodynamic parameters can be obtained from these computations, to date, no consistent methodology for the prediction of the rupture has been identified. One particular challenge to CFD is that many factors contribute to its accuracy; the mesh resolution and spatial/temporal discretization can alone contribute to a variation in accuracy. This failure to identify the importance of these factors and identify a methodology for the prediction of ruptures has limited the acceptance of CFD among physicians for rupture prediction. The International CFD Rupture Challenge 2013 seeks to comment on the sensitivity of these various CFD assumptions to predict the rupture by undertaking a comparison of the rupture and blood-flow predictions from a wide range of independent participants utilizing a range of CFD approaches. Twenty-six groups from 15 countries took part in the challenge. Participants were provided with surface models of two intracranial aneurysms and asked to carry out the corresponding hemodynamics simulations, free to choose their own mesh, solver, and temporal discretization. They were requested to submit velocity and pressure predictions along the centerline and on specified planes. The first phase of the challenge, described in a separate paper, was aimed at predicting which of the two aneurysms had previously ruptured and where the rupture site was located. The second phase, described in this paper, aims to assess the variability of the solutions and the sensitivity to the modeling assumptions. Participants were free to choose boundary conditions in the first phase, whereas they were prescribed in the second phase but all other CFD modeling parameters were not prescribed. In order to compare the computational results of one representative group with experimental results, steady-flow measurements using particle image velocimetry (PIV) were carried out in a silicone model of one of the provided aneurysms. Approximately 80% of the participating groups generated similar results. Both velocity and pressure computations were in good agreement with each other for cycle-averaged and peak-systolic predictions. Most apparent "outliers" (results that stand out of the collective) were observed to have underestimated velocity levels compared to the majority of solutions, but nevertheless identified comparable flow structures. In only two cases, the results deviate by over 35% from the mean solution of all the participants. Results of steady CFD simulations of the representative group and PIV experiments were in good agreement. The study demonstrated that while a range of numerical schemes, mesh resolution, and solvers was used, similar flow predictions were observed in the majority of cases. To further validate the computational results, it is suggested that time-dependent measurements should be conducted in the future. However, it is recognized that this study does not include the biological aspects of the aneurysm, which needs to be considered to be able to more precisely identify the specific rupture risk of an intracranial aneurysm.


Assuntos
Aneurisma Roto/fisiopatologia , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Circulação Cerebrovascular , Aneurisma Intracraniano/fisiopatologia , Modelos Cardiovasculares , Simulação por Computador , Humanos , Resistência ao Cisalhamento
4.
J Biomech Eng ; 135(2): 021016, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23445061

RESUMO

Stimulated by a recent controversy regarding pressure drops predicted in a giant aneurysm with a proximal stenosis, the present study sought to assess variability in the prediction of pressures and flow by a wide variety of research groups. In phase I, lumen geometry, flow rates, and fluid properties were specified, leaving each research group to choose their solver, discretization, and solution strategies. Variability was assessed by having each group interpolate their results onto a standardized mesh and centerline. For phase II, a physical model of the geometry was constructed, from which pressure and flow rates were measured. Groups repeated their simulations using a geometry reconstructed from a micro-computed tomography (CT) scan of the physical model with the measured flow rates and fluid properties. Phase I results from 25 groups demonstrated remarkable consistency in the pressure patterns, with the majority predicting peak systolic pressure drops within 8% of each other. Aneurysm sac flow patterns were more variable with only a few groups reporting peak systolic flow instabilities owing to their use of high temporal resolutions. Variability for phase II was comparable, and the median predicted pressure drops were within a few millimeters of mercury of the measured values but only after accounting for submillimeter errors in the reconstruction of the life-sized flow model from micro-CT. In summary, pressure can be predicted with consistency by CFD across a wide range of solvers and solution strategies, but this may not hold true for specific flow patterns or derived quantities. Future challenges are needed and should focus on hemodynamic quantities thought to be of clinical interest.


Assuntos
Aneurisma/fisiopatologia , Bioengenharia , Circulação Sanguínea , Simulação por Computador , Hidrodinâmica , Pressão , Congressos como Assunto , Humanos , Cinética , Sociedades Científicas
5.
Cardiovasc Eng Technol ; 9(4): 544-564, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30203115

RESUMO

PURPOSE: Image-based computational fluid dynamics (CFD) is widely used to predict intracranial aneurysm wall shear stress (WSS), particularly with the goal of improving rupture risk assessment. Nevertheless, concern has been expressed over the variability of predicted WSS and inconsistent associations with rupture. Previous challenges, and studies from individual groups, have focused on individual aspects of the image-based CFD pipeline. The aim of this Challenge was to quantify the total variability of the whole pipeline. METHODS: 3D rotational angiography image volumes of five middle cerebral artery aneurysms were provided to participants, who were free to choose their segmentation methods, boundary conditions, and CFD solver and settings. Participants were asked to fill out a questionnaire about their solution strategies and experience with aneurysm CFD, and provide surface distributions of WSS magnitude, from which we objectively derived a variety of hemodynamic parameters. RESULTS: A total of 28 datasets were submitted, from 26 teams with varying levels of self-assessed experience. Wide variability of segmentations, CFD model extents, and inflow rates resulted in interquartile ranges of sac average WSS up to 56%, which reduced to < 30% after normalizing by parent artery WSS. Sac-maximum WSS and low shear area were more variable, while rank-ordering of cases by low or high shear showed only modest consensus among teams. Experience was not a significant predictor of variability. CONCLUSIONS: Wide variability exists in the prediction of intracranial aneurysm WSS. While segmentation and CFD solver techniques may be difficult to standardize across groups, our findings suggest that some of the variability in image-based CFD could be reduced by establishing guidelines for model extents, inflow rates, and blood properties, and by encouraging the reporting of normalized hemodynamic parameters.


Assuntos
Angiografia Cerebral/métodos , Circulação Cerebrovascular , Hemodinâmica , Aneurisma Intracraniano/diagnóstico por imagem , Artéria Cerebral Média/diagnóstico por imagem , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Velocidade do Fluxo Sanguíneo , Humanos , Imageamento Tridimensional , Aneurisma Intracraniano/fisiopatologia , Artéria Cerebral Média/fisiopatologia , Valor Preditivo dos Testes , Prognóstico , Interpretação de Imagem Radiográfica Assistida por Computador , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Estresse Mecânico
6.
Cardiovasc Eng Technol ; 9(4): 565-581, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30191538

RESUMO

PURPOSE: Advanced morphology analysis and image-based hemodynamic simulations are increasingly used to assess the rupture risk of intracranial aneurysms (IAs). However, the accuracy of those results strongly depends on the quality of the vessel wall segmentation. METHODS: To evaluate state-of-the-art segmentation approaches, the Multiple Aneurysms AnaTomy CHallenge (MATCH) was announced. Participants carried out segmentation in three anonymized 3D DSA datasets (left and right anterior, posterior circulation) of a patient harboring five IAs. Qualitative and quantitative inter-group comparisons were carried out with respect to aneurysm volumes and ostia. Further, over- and undersegmentation were evaluated based on highly resolved 2D images. Finally, clinically relevant morphological parameters were calculated. RESULTS: Based on the contributions of 26 participating groups, the findings reveal that no consensus regarding segmentation software or underlying algorithms exists. Qualitative similarity of the aneurysm representations was obtained. However, inter-group differences occurred regarding the luminal surface quality, number of vessel branches considered, aneurysm volumes (up to 20%) and ostium surface areas (up to 30%). Further, a systematic oversegmentation of the 3D surfaces was observed with a difference of approximately 10% to the highly resolved 2D reference image. Particularly, the neck of the ruptured aneurysm was overrepresented by all groups except for one. Finally, morphology parameters (e.g., undulation and non-sphericity) varied up to 25%. CONCLUSIONS: MATCH provides an overview of segmentation methodologies for IAs and highlights the variability of surface reconstruction. Further, the study emphasizes the need for careful processing of initial segmentation results for a realistic assessment of clinically relevant morphological parameters.


Assuntos
Angiografia Cerebral/métodos , Circulação Cerebrovascular , Hemodinâmica , Aneurisma Intracraniano/diagnóstico por imagem , Artéria Cerebral Média/diagnóstico por imagem , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/etiologia , Aneurisma Roto/fisiopatologia , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Imageamento Tridimensional , Aneurisma Intracraniano/complicações , Aneurisma Intracraniano/fisiopatologia , Pessoa de Meia-Idade , Artéria Cerebral Média/fisiopatologia , Valor Preditivo dos Testes , Prognóstico , Interpretação de Imagem Radiográfica Assistida por Computador , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Estresse Mecânico , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/etiologia , Hemorragia Subaracnóidea/fisiopatologia
7.
Adv Mater ; 27(14): 2298-304, 2015 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-25684077

RESUMO

A versatile and robust microfluidic nanoprecipitation platform for high throughput synthesis of nanoparticles is fabricated. The versatility of this platform is proven through the successful preparation of different types of nanoparticles. This platform presents great robustness, with homogeneous nanoparticles always being obtained, regardless of the formulation parameters. The diameter and surface charge of the prepared nanoparticles can also be easily tuned.


Assuntos
Dispositivos Lab-On-A-Chip , Nanopartículas/química , Nanotecnologia/instrumentação , Técnicas de Química Sintética
8.
Sci Rep ; 5: 13606, 2015 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-26391513

RESUMO

Thrombus formation is a multiscale phenomenon triggered by platelet deposition over a protrombotic surface (eg. a ruptured atherosclerotic plaque). Despite the medical urgency for computational tools that aid in the early diagnosis of thrombotic events, the integration of computational models of thrombus formation at different scales requires a comprehensive understanding of the role and limitation of each modelling approach. We propose three different modelling approaches to predict platelet deposition. Specifically, we consider measurements of platelet deposition under blood flow conditions in a perfusion chamber for different time periods (3, 5, 10, 20 and 30 minutes) at shear rates of 212 s(-1), 1390 s(-1) and 1690 s(-1). Our modelling approaches are: i) a model based on the mass-transfer boundary layer theory; ii) a machine-learning approach; and iii) a phenomenological model. The results indicate that the three approaches on average have median errors of 21%, 20.7% and 14.2%, respectively. Our study demonstrates the feasibility of using an empirical data set as a proxy for a real-patient scenario in which practitioners have accumulated data on a given number of patients and want to obtain a diagnosis for a new patient about whom they only have the current observation of a certain number of variables.


Assuntos
Plaquetas/fisiologia , Modelos Teóricos , Agregação Plaquetária , Trombose , Algoritmos , Simulação por Computador , Humanos , Reprodutibilidade dos Testes
9.
ACS Appl Mater Interfaces ; 7(27): 14822-32, 2015 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-26098382

RESUMO

Herein, we report the production of monodisperse hollow microparticles from three different polymers, namely, pH-responsive acetylated dextran and hypromellose acetate succinate and biodegradable poly(lactic-co-glycolic acid), at varying polymer concentrations using a poly(dimethylsiloxane)-based microfluidic device. Hollow microparticles formed during solvent diffusion into the continuous phase when the polymer close to the interface solidified, forming the shell. In the inner part of the particle, phase separation induced solvent droplet formation, which dissolved the shell, forming a hole and a hollow-core particle. Computational simulations showed that, despite the presence of convective recirculation around the droplet, the mass-transfer rate of the solvent dissolution from the droplet to the surrounding phase was dominated by diffusion. To illustrate the potential use of hollow microparticles, we simultaneously encapsulated two anticancer drugs and investigated their loading and release profiles. In addition, by utilizing different polymer shells and polymer concentrations, the release profiles of the model drugs could be tailored according to specific demands and applications. The high encapsulation efficiency, controlled drug release, unique hollow microparticle structure, small particle size (<7 µm), and flexibility of the polymer choice could make these microparticles advanced platforms for pulmonary drug delivery.


Assuntos
Cápsulas/química , Dimetilpolisiloxanos/química , Combinação de Medicamentos , Composição de Medicamentos/instrumentação , Microfluídica/instrumentação , Absorção Fisico-Química , Simulação por Computador , Desenho de Fármacos , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Modelos Químicos , Tamanho da Partícula , Polímeros/química , Porosidade
11.
Thromb Res ; 131(2): 116-24, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23260443

RESUMO

Hemodynamics applied to mechanobiology offers powerful means to predict thrombosis, and to understand the kinetics of thrombus formation on areas of vascular damage in blood flowing through the human circulatory system. Specifically, the advances in computational processing and the progress in modeling complex biological processes with spatio-temporal multi-scale methods have the potential to shift the way in which cardiovascular diseases are diagnosed and treated. This article systematically surveys the state of the art of macroscopic computational fluid dynamics (CFD) Computational fluid dynamics techniques for modeling thrombus formation, highlighting their strengths and weaknesses. In particular, a comprehensive and systematic revision of the hemodynamics models and methods is given, and the strengths and weaknesses of those employed for studying thrombus formation are highlighted.


Assuntos
Modelos Cardiovasculares , Trombose/patologia , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Hemodinâmica , Humanos
12.
Microfluid Nanofluidics ; 13(2): 227-237, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23795150

RESUMO

Capillary-driven flow (CD-flow) in microchannels plays an important role in many microfluidic devices. These devices, the most popular being those based in lateral flow, are becoming increasingly used in health care and diagnostic applications. CD-flow can passively pump biological fluids as blood, serum or plasma, in microchannels and it can enhance the wall mass transfer by exploiting the convective effects of the flow behind the meniscus. The flow behind the meniscus has not been experimentally identified up to now because of the lack of high-resolution, non-invasive, cross-sectional imaging means. In this study, spectral-domain Doppler optical coherence tomography is used to visualize and measure the flow behind the meniscus in CD-flows of water and blood. Microchannels of polydimethylsiloxane and glass with different cross-sections are considered. The predictions of the flow behind the meniscus of numerical simulations using the power-law model for non-Newtonian fluids are in reasonable agreement with the measurements using blood as working fluid. The extension of the Lucas-Washburn equation to non-Newtonian power-law fluids predicts well the velocity of the meniscus of the experiments using blood.

13.
Interface Focus ; 1(3): 338-48, 2011 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-22670204

RESUMO

Cerebral aneurysms are abnormal focal dilatations of artery walls. The interest in virtual tools to help clinicians to value the effectiveness of different procedures for cerebral aneurysm treatment is constantly growing. This study is focused on the analysis of the influence of different stent deployment approaches on intra-aneurysmal haemodynamics using computational fluid dynamics (CFD). A self-expanding stent was deployed in an idealized aneurysmatic cerebral vessel in two initial positions. Different cases characterized by a progression of simplifications on stent modelling (geometry and material) and vessel material properties were set up, using finite element and fast virtual stenting methods. Then, CFD analysis was performed for untreated and stented vessels. Haemodynamic parameters were analysed qualitatively and quantitatively, comparing the cases and the two initial positions. All the cases predicted a reduction of average wall shear stress and average velocity of almost 50 per cent after stent deployment for both initial positions. Results highlighted that, although some differences in calculated parameters existed across the cases based on the modelling simplifications, all the approaches described the most important effects on intra-aneurysmal haemodynamics. Hence, simpler and faster modelling approaches could be included in clinical workflow and, despite the adopted simplifications, support clinicians in the treatment planning.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA