Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Vasc Interv Radiol ; 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38942284

RESUMO

PURPOSE: The purpose of this study was to retrospectively analyze the degree of renal function deterioration after renal cryoablation in patients with a solitary functioning kidney based on ablation volume. MATERIALS AND METHODS: Over a 15-year period, 81 percutaneous cryoablations were performed in solitary functioning kidneys. After exclusion of patients with baseline end-stage renal disease(ESRD) and insufficient follow up, analysis was performed on 65 procedures in 52 patients (40 male, mean age 63.5 years). The post-cryoablation renal function was based on the lowest serum creatinine within 6 months post-procedure. Renal function change was defined as percentage glomerular filtration rate(GFR) change. Volumetric analysis was performed on the target lesion, renal parenchyma, and ablation zone. RESULTS: The median tumor diameter was 2.0cm (range 0.8-4.7cm). The median baseline GFR decreased from 56.4 mL/min/1.73m2 (range 17.5-89.7) to 46.9 (range 16.5-89.7) at median 95 days (p<0.001), equating to an -7.9% median renal function change (range -45.0 to +30.7). All patients had stage 2 or worse chronic kidney disease and baseline function did not correlate with renal function change. The median volume of ablated parenchyma was 19.7mL (range 2.4-87.3mL), equating to 8.1% (range 0.7-37.2%) of total parenchyma. The volume of parenchymal volume ablated correlated significantly with renal function loss, while age, hypertension, and diabetes mellitus did not. No patients developed ESRD within 1 year after cryoablation. CONCLUSION: Cryoablation in solitary functioning kidneys resulted in a modest reduction in renal function, even in patients with chronic kidney disease and ablations up to 20% of renal parenchymal volume.

2.
J Vasc Interv Radiol ; 34(4): 710-715, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36718760

RESUMO

PURPOSE: To compare the diagnostic accuracy and adverse event rates of intravascular ultrasound (US)-guided transvenous biopsy (TVB) versus those of computed tomography (CT)-guided percutaneous needle biopsy (PNB) for retroperitoneal (RP) lymph nodes. MATERIALS AND METHODS: In this single-institution, retrospective study, 32 intravascular US-guided TVB procedures and a sample of 34 CT-guided PNB procedures for RP lymph nodes where targets were deemed amenable to intravascular US-guided TVB were analyzed. Procedural metrics, including diagnostic accuracy, defined as diagnostic of malignancy or a clinically verifiable benign result, and adverse event rates were compared. RESULTS: The targets of intravascular US-guided TVB were primarily aortocaval (47%, 15/32) or precaval (34%, 11/32), whereas those of CT-guided PNB were primarily right pericaval (44%, 15/34) or retrocaval (44%, 15/34) (P < .001). The targets of intravascular US-guided TVB averaged 2.4 cm in the long axis (range, 1.3-3.7 cm) compared with 2.9 cm (range, 1.4-5.7 cm) for those of CT-guided PNB (P = .02). There was no difference in the average number of needle passes (3.8 for intravascular US-guided TVB vs 3.9 for CT-guided PNB; P = .68). The diagnostic accuracy was 94% (30/32) and the adverse event rate was 3.1% (1/32) for intravascular US-guided TVB, similar to those of CT-guided PNB (accuracy, 91% [31/34]; adverse event rate, 2.9% [1/34]). CONCLUSIONS: Intravascular US-guided TVB had a diagnostic accuracy and adverse event rate similar to CT-guided PNB for RP lymph nodes, indicating that intravascular US-guided TVB may be as safe and effective as conventional biopsy approaches for appropriately selected targets.


Assuntos
Biópsia Guiada por Imagem , Linfonodos , Humanos , Estudos Retrospectivos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Tomografia Computadorizada por Raios X , Ultrassonografia de Intervenção/efeitos adversos
3.
J Vasc Interv Radiol ; 34(10): 1680-1689.e2, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37400054

RESUMO

PURPOSE: To compare the laboratory markers of acute liver injury after transjugular intrahepatic portosystemic shunt (TIPS) creation performed using intravascular ultrasound (IVUS) guidance with those using other techniques. MATERIALS AND METHODS: This single-center, retrospective study examined 293 TIPS procedures performed between 2014 and 2022 (160 men; mean age, 57.4 years; 71.7% with ascites, 158 with IVUS). Laboratory changes on postprocedural day (PPD) 1 were classified based on Common Terminology Criteria for Adverse Events (CTCAE) grades and were compared between IVUS and non-IVUS cases. RESULTS: IVUS cases had a lower baseline Model for End-Stage Liver Disease (MELD) score (12.5 vs 13.7, P = .016), higher pre- (16.8 vs 15.2, P = .009), and post-TIPS (6.6 vs 5.4 mm Hg, P < .001) pressure gradient, smaller stent diameter (9.2 vs 9.9 mm, P < .001), and fewer needle passes (2.4 vs 4.2, P < .001). IVUS predicted a lower PPD 1 CTCAE grade for aspartate transaminase (8.0% vs 22.2% grade ≥ 2, P = .010), alanine transaminase (ALT) (2.2% vs 7.1%, P = .017), and bilirubin (9.4% vs 26.2%, P < .001), findings confirmed using multivariable regression and propensity score analysis. IVUS predicted fewer adverse events (1.3% vs 8.1%, P = .008) and an increased likelihood of PPD 1 discharge (81% vs 59%, P = .004). IVUS was not associated with differences in PPD 30 MELD scores or 30-day survival; however, higher PPD 1 ALT (ß = 1.96, P = .008) and bilirubin levels (ß = 1.38, P = .004) predicted larger PPD 30 MELD score increase. Higher increases in ALT level predicted worse 30-day survival (hazard ratio, 1.93; P = .021). CONCLUSION: IVUS resulted in less laboratory evidence of acute liver injury immediately following TIPS creation.

4.
J Vasc Interv Radiol ; 33(12): 1513-1518.e1, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36084844

RESUMO

A technique to create a coaxial, self-expanding stent graft inside a constraining, bare-metal, balloon-expandable stent for transjugular intrahepatic portosystemic shunt (TIPS) reduction is described. The key steps are performed on a back table rather than inside the patient, and the resulting construct is deployed using standard unsheathing maneuvers. The construct was used in 4 patients to make 6 TIPS diameter reductions (mean postreduction diameter, 6 mm; range, 0-8 mm), all resulting in increases in the portosystemic pressure gradient (mean increase, 6 mm Hg; range, 1-19 mm Hg). On average, hepatic encephalopathy improved 1 point on the West Haven scale (range, 0-2).


Assuntos
Encefalopatia Hepática , Procedimentos de Cirurgia Plástica , Derivação Portossistêmica Transjugular Intra-Hepática , Humanos , Derivação Portossistêmica Transjugular Intra-Hepática/efeitos adversos , Politetrafluoretileno , Stents , Resultado do Tratamento
5.
J Vasc Interv Radiol ; 31(2): 243-250, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31706885

RESUMO

PURPOSE: To compare outcomes after conversion of arteriovenous (AV) access to Hemodialysis Reliable Outflow (HeRO) graft vs stent deployment in patients with arm swelling owing to ipsilateral central vein stenosis. MATERIALS AND METHODS: This single-center retrospective study comprised 48 patients (19 men, mean age 58 y) with arm swelling ipsilateral to AV access and central vein stenosis over a 13-year period who had clinical follow-up and without prior central stents. Twenty-one patients underwent placement of a HeRO graft with anastomosis of the HeRO graft to the existing graft or fistula, and 27 patients underwent central venous stent deployment. Symptomatic improvement in arm swelling and access patency rates after intervention were ascertained from medical records. RESULTS: Improvement in swelling within 1 month after HeRO conversion and stent deployment was found in 95% and 89%, respectively (P = .62). Swelling eventually recurred in 16 patients (59%) treated with stents compared with 1 patient (5%) who underwent HeRO conversion (P < .001). Primary access patency was statistically significantly longer after HeRO conversions than stent deployments, with 6- and 12-month primary patency rates of 89% and 72% vs 47% and 11% (P < .001). HeRO conversions also resulted in longer 6- and 12-month secondary access patency rates (95% and 95% vs 79% and 58%, P = .006). Mean number of interventions per 1,000 access days to maintain secondary patency was 2.7 for the HeRO group vs 6.3 for the stent group. CONCLUSIONS: Although stent deployment and HeRO graft conversion are effective for alleviating arm swelling in the short term in patients receiving hemodialysis with clinically significant arm swelling and functioning AV access, the HeRO graft has more durable results.


Assuntos
Angioplastia com Balão/instrumentação , Derivação Arteriovenosa Cirúrgica/instrumentação , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Oclusão de Enxerto Vascular/cirurgia , Diálise Renal , Stents , Extremidade Superior/irrigação sanguínea , Angioplastia com Balão/efeitos adversos , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
8.
Clin Imaging ; 110: 110142, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38696997

RESUMO

PURPOSE: The purpose of this study was to evaluate long-term morphologic changes occurring in the liver after TIPS creation with correlation with hepatic function to gain insight on the physiologic impact of TIPS on the liver. METHODS: This retrospective study included patients who underwent TIPS creation between 2005 and 2022 and had contrasted CT or MRI studies prior to and between 1 and 2 years post procedure. Strict exclusion criteria were applied to avoid confounding. Parenchymal volume and vessel measurements were assessed on the pre- and post-TIPS CT or MRI and MELD scores calculated. RESULTS: Of 580 patients undergoing TIPS creation, 65 patients (mean age, 55 years; 36 males) had pre-TIPS and post-TIPS imaging meeting inclusion criteria at median 16.5 months. After TIPS, the mean MELD score increased (12.9 to 15.4; p = 0.008) and total liver volume decreased (1730 to 1432 mL; p < 0.001). However, the magnitude of volume change did not correlate with MELD change. Neither portosystemic gradient nor TIPS laterality correlated with total or lobar hepatic volume changes or MELD changes. The main portal vein diameter increased (15.0 to 18.7 mm; p < 0.001). Thrombosis of the hepatic vein used for TIPS creation resulted in a mean increase in MELD of +4.1 compared to -2.1 in patients who had a patent and normal hepatic vein (p = 0.007). CONCLUSIONS: Given lack of correlation between portosystemic gradient, hepatic atrophy, hepatic function, and TIPS laterality, the alterations in portal flow dynamics after TIPS may not be impactful to hepatic function. However, hepatic vein patency after TIPS correlated with improved hepatic function.


Assuntos
Fígado , Imageamento por Ressonância Magnética , Derivação Portossistêmica Transjugular Intra-Hepática , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Resultado do Tratamento
9.
Clin Imaging ; 94: 103-107, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36525881

RESUMO

BACKGROUND: Intraprocedural Cone Beam CT (CBCT) is assessed to examine if use improves diagnosis and embolization rates of acute lower GI bleed (LGIB) and if automatic vessel detection (AVD) software can identify feeding vessels (FV) for embolization. METHODS: Patients with inconclusive DSA findings had CBCT and retrospective analysis with AVD software (Innova 3100, GE Company, USA). Technical success was defined as the ability to detect a lower GIB site while clinical success was defined as successful embolization without evidence of rebleeding or death within 30 days. AVD technical success was defined by the ability to identify the FV on both CTA and CBCT upon independent review by 3 blinded IRs, who also assigned a degree of certainty on a 5-point Likert scale. RESULTS: 74 patients in total were treated for lower GI bleed of which 34 had indeterminate DSA. Of those, 10 patients received DSA only, of which 1 was super selective. 24 patients with GIB on pre-procedural CTA and inconclusive DSA underwent CBCT. Use of CBCT identified 9 bleeds not seen on DSA and an additional source artery in 1 case representing a 42% change in intraprocedural management as all findings were embolized. When a bleed could not be identified on CBCT, but the FV could be identified on CTA, the same suspected FV could be selected on AVD 62% of the time with an average certainty of 4.0. CONCLUSION: CBCT is useful in the intraprocedural detection of GIB when DSA is indeterminate. Furthermore, AVD software can feasibly be utilized to accurately identify FVs for empiric treatment when intraprocedural imaging is inconclusive. LEVEL OF EVIDENCE: Level III, therapeutic study.


Assuntos
Embolização Terapêutica , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Estudos Retrospectivos , Angiografia Digital/métodos , Embolização Terapêutica/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Hemorragia Gastrointestinal/diagnóstico por imagem , Hemorragia Gastrointestinal/terapia
10.
Clin Imaging ; 82: 117-120, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34808582

RESUMO

BACKGROUND: Adenomyosis is a common gynecologic pathology that relies on diagnostic imaging to guide treatment. Accuracy of both pelvic ultrasound and magnetic resonance imaging (MRI) when specifically evaluating for the presence of adenomyosis is high. However, the accuracy of reported rates in clinical practice is less well understood. PURPOSE: To demonstrate the accuracy in reporting of adenomyosis on pelvic ultrasound and MRI compared to histopathology in common clinical practice. BASIC PROCEDURES: An institutional database was searched for women with a pelvic ultrasound and a pelvic MRI with a subsequent hysterectomy. Findings were extracted from radiology and pathology reports, and the documented presence or absence of adenomyosis was recorded for each modality. Blinded radiologists viewed each imaging pair to directly evaluate for adenomyosis. MAIN FINDINGS: Compared to prior published data, imaging had lower accuracy in clinical practice when adenomyosis was not specifically evaluated for. For the finding of adenomyosis, pelvic ultrasound had a sensitivity of 10.9%, a specificity of 98.3%, positive predictive value (PPV) of 77.8%, negative predictive value (NPV) of 66.7%, an accuracy of 67.2%, and a diagnostic odds ratio (DOR) of 7. Pelvic MRI had a sensitivity of 29.7%, specificity of 85.3%, PPV of 52.8%, NPV of 68.8%, an accuracy of 65.6%, and DOR of 2.5. Overall accuracy of MRI improved when adenomyosis was directly evaluated for (82.4% vs 65.6%). PRINCIPLE CONCLUSIONS: Without direct communication to evaluate for adenomyosis, pelvic ultrasound and MRI may underestimate or misreport adenomyosis. Providers should be aware of these discrepancies when relying on radiology reports to guide treatment and potential interventions when diagnosing and managing adenomyosis.


Assuntos
Adenomiose , Endometriose , Patologia Cirúrgica , Adenomiose/diagnóstico por imagem , Adenomiose/cirurgia , Endometriose/diagnóstico por imagem , Endometriose/cirurgia , Feminino , Humanos , Imageamento por Ressonância Magnética , Sensibilidade e Especificidade , Ultrassonografia
11.
J Vasc Access ; : 11297298211048061, 2021 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-34892983

RESUMO

BACKGROUND: The purpose of this study was to assess the feasibility and outcomes of recanalization and subsequent HeRO graft outflow component insertion across stent interstices in patients with an otherwise abandoned upper extremity. METHODS: Over a 10-year period, 15 patients underwent central venous recanalization by interventional radiology across the interstices of one or more occluded stents for the purpose of subsequent HeRO graft creation. A tunneled central venous catheter was left across the stent and occlusions with tip in right atrium. On a later date, the catheter was used for rapid guidewire access for HeRO graft implantation in the OR by vascular surgery. Procedural and clinical outcomes were determined by retrospective review. Primary and secondary HeRO graft patency rates were estimated with the Kaplan-Meier technique. RESULTS: The technical success rates of recanalization across stent interstices was 100% (15/15). Between one and four overlapping stent walls were traversed. The technical success of the patients who underwent attempted HeRO graft implantation with outflow component traversing across stent interstices was 91% (11/12). No major complications were encountered with either recanalization or HeRO graft implantation. The primary and secondary HeRO patency rates at 12 months were 64% and 80%, respectively. CONCLUSION: HeRO graft insertion across stent interstices is feasible and can provide effective permanent AV access; thus, the presence of stents across the subclavian and brachiocephalic veins should not be considered a contraindication.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA