Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

País/Região como assunto
Intervalo de ano de publicação
1.
Int Endod J ; 57(1): 64-77, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37814380

RESUMO

AIM: To determine the cytotoxicity mechanism of 2.5% calcium hypochlorite [Ca(OCl)2 ] in L929 fibroblasts and the effect of this solution on human osteoblast-like cells (Saos-2) mineralization, compared to that of 2.5% sodium hypochlorite (NaOCl). METHODOLOGY: L929 fibroblasts were exposed to Ca(OCl)2 and NaOCl at different dilutions for 10 min. Cell metabolism was assessed by methyl-thiazole-tetrazolium (MTT); lysosome integrity, by neutral red (NR) assay; type of cell death, by flow cytometry (apoptosis/necrosis); cytoskeleton, by actin and α-tubulin fluorescence and cell ultrastructure, by transmission electron microscopy (TEM). The alkaline phosphatase (ALP) activity and mineralized nodule formation were determined in Saos-2 by thymolphthalein release and alizarin red staining (ARS), respectively. The data were analysed by two-way anova and Bonferroni's post-test (α = .05). RESULTS: Ca(OCl)2 promoted higher cell viability and a lower percentage of apoptosis and necrosis than NaOCl (p < .05). Ca(OCl)2 and NaOCl decreased cell metabolism and lysosome integrity, induced the breakdown of microtubules and actin filaments, promoted alterations of rough endoplasmic reticulum and disruption of mitochondrial cristae. Additionally, Ca(OCl)2 did not induce ALP activity and had no effect on mineralized nodules formation. CONCLUSIONS: Although Ca(OCl)2 and NaOCl promoted the same cytotoxicity mechanism, Ca(OCl)2 was less cytotoxic than NaOCl. As for ALP activity, no differences were observed between NaOCl and Ca(OCl)2 . The production of mineralized nodules induced by Ca(OCl)2 was lower than those induced by NaOCl, but was not different from those induced by the control group.


Assuntos
Fibroblastos , Hipoclorito de Sódio , Humanos , Hipoclorito de Sódio/toxicidade , Necrose , Osteoblastos , Irrigantes do Canal Radicular/farmacologia
2.
Int Endod J ; 55(11): 1252-1261, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35976101

RESUMO

AIM: The aim of the study was to assess biofilm removal efficacy of GentleWave System and passive ultrasonic irrigation (PUI). METHODOLOGY: Twenty-two human mandibular molars with Vertucci's type II configuration in the mesial root were selected. Teeth were autoclaved, inoculated with dental plaque and incubated in a CDC biofilm reactor for two weeks. The mesial roots were instrumented up to 20.06 file (V-Taper) for the GentleWave group and up to 35.04 file (Vortex Blue) for PUI group. Irrigation was performed using GentleWave and PUI irrigation protocols (n = 11). Dentine debris on paper points samples were obtained for quantitative real-time polymerase chain reaction (qPCR) and 16S ribosomal RNA gene sequencing (next-generation aequencing-NGS). For qPCR, a non-parametric test (α = 0.05) was used. Next-generation sequencing data were analysed using mothur, with alpha diversity calculated as the Shannon and Chao1 indices and Bray-Curtis dissimilarities were used for beta diversity. Differences in alpha diversity and abundances of genera were evaluated using Kruskal-Wallis test. Differences in community composition were evaluated using analysis of similarity with Bonferroni correction for multiple comparisons. RESULTS: Quantitative real-time polymerase chain reaction results showed that the reduction estimated in percentages for both groups was equivalent (p > .05). NGS analysis showed that both techniques promoted a significant reduction in reads and OTUs number (p < .05). Shannon alpha diversity and Chao1 index showed no differences between pre- or post-treatment samples for both groups (p > .05). Additionally, pre-treatment communities differed from post-treatment samples in both groups regarding bacterial taxa reduction (ANOSIM R = 0.50 and 0.55, p < .001). CONCLUSIONS: Bacterial reduction in mesial roots of mandibular molars prepared to 35.04 with PUI was similar to those prepared to 20.06 with a multisonic irrigant activation system.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Biofilmes , Humanos , Dente Molar , Irrigantes do Canal Radicular , Preparo de Canal Radicular/métodos , Irrigação Terapêutica/métodos , Ultrassom
3.
Heliyon ; 10(1): e23060, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38192787

RESUMO

Sodium hypochlorite (NaOCl) cytotoxicity has been assessed using different methodologies, which has led to arbitrary interpretations. This scoping review aimed to discuss the different methodological protocols for assessing NaOCl cytotoxicity. A literature review performed in the PubMed and Embase databases up to July 2023 identified manuscripts reporting NaOCl cytotoxicity. The dataset identified 546 publications, further screened by 2 reviewers. Ninety studies were identified and mined methodologically to collect information on cell type, cytotoxicity assay, NaOCl dilution solutions, presence of fetal bovine serum (FBS), and NaOCl exposure time. The culture medium used in cytotoxicity assays contains buffering substances that neutralize the pH of NaOCl, thus reducing its cytotoxicity, an approach that may lead to bias when solutions with different pH are compared. For short exposure periods, as in simulations to evaluate the contact between irrigant and periapical tissue cells during chemo-mechanical preparation, NaOCl dilution should be performed with saline, which does not buffer the irrigant. For long exposure periods, as in simulations of irrigant extrusions, NaOCl should be diluted in the culture medium, to reproduce the expected buffering effect occurring in extrusions. The presence of FBS in culture medium can decrease NaOCl toxicity. There is no standardization of NaOCl cytotoxicity methodologies. This poses the risk of arriving at incorrect results and, therefore, pertinent tests must be refined.

4.
Int J Dent ; 2024: 5945033, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38957372

RESUMO

Objective: To evaluate the solubility and the volumetric and morphological alterations of bioceramic filling material (Bio-CP) for primary teeth. Materials and Methods: Bio-CP, Calen thickened with zinc oxide (Calen-ZO), and with zinc oxide eugenol (ZOE) were placed in 1- or 2-mm-diameter polyethylene tubes and immersed in water or phosphate-buffered saline (PBS) for 30 days. The solubility (mass loss) was assessed using methodology modified from ISO 6876. Filling capacity, volumetric changes, and presence of voids were assessed by microcomputed tomography (micro-CT). The surface distribution of the chemical elements and the crystalline phases was evaluated by energy scattering X-ray scanning electron microscopy (SEM-EDX) and X-ray diffraction (XRD) to detect hydroxyapatite precipitate and components. The Shapiro-Wilk, Kruskal-Wallis, and Dunn's or two-way ANOVA and Tukey post hoc test were used (α = 0.05). Results: The solubility was ZOE > Calen-ZO = Bio-CP. Calen-ZO and Bio-CP were more soluble in water than in PBS. All the materials showed greater solubility in 2-mm tube diameter in both PBS and distilled water, except for Bio-CP in distilled water, which showed no difference between both tube diameters (1 and 2 mm). Only Calen-ZO and ZOE were analyzed by micro-CT, because Bio-CP separated into two phases during scanning. Calen-ZO had greater volumetric loss and presence of voids than ZOE in water, but there was no difference in PBS. The hydroxyapatite precipitate on the surface of Bio-CP and Calen-ZO was detected after immersion in PBS. Conclusion: Although Bio-CP had acceptable solubility and filling capacity, its composition did not allow a proper volumetric and void assessment. From a clinical perspective, Bio-CP has the potential to become a suitable material for root canal filling in primary teeth. Nonetheless, its composition must first be revised to achieve better chemical stability prior to its recommendation.

5.
Aust Endod J ; 49(2): 358-364, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35932460

RESUMO

Two patients were admitted to the dental clinic to evaluate two right mandibular first molars (both FDI no. 46). In Case 1, there was an accidental instrument separation, which was thought to have been bypassed; however, the instrument was located beyond the apical foramen, in the alveolar bone. The 1-week follow-up revealed that the fragment was close to the inferior alveolar nerve, thus allowing surgical removal to be performed. In Case 2, two separated instruments located in the apical third of the mesiobuccal and mesiolingual canals were removed using the HBW ultrasonic ring coupled to ISO 10 and 15 hand instruments. The 3-month and 1-year follow-ups (Case 1), and the 2-year and 3-year follow-ups (Case 2) showed a favourable evolution in both cases. It can be concluded that both the surgical approach and the HBW ultrasonic ring are viable options for the removal of separated instruments in unfavourable locations.


Assuntos
Preparo de Canal Radicular , Ultrassom , Humanos , Cavidade Pulpar , Ápice Dentário , Dente Molar/diagnóstico por imagem , Dente Molar/cirurgia , Instrumentos Odontológicos
6.
Tissue Cell ; 83: 102157, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37451011

RESUMO

Cysteine proteases orchestrate bone remodeling, and are inhibited by cystatins. In reinforcing our hypothesis that exogenous and naturally obtained inhibitors of cysteine proteases (cystatins) act on bone remodeling, we decided to challenge osteoblasts with sugarcane-derived cystatin (CaneCPI-5) for up to 7 days. To this end, we investigated molecular issues related to the decisive, preliminary stages of osteoblast biology, such as adhesion, migration, proliferation, and differentiation. Our data showed that CaneCPI-5 negatively modulates both cofilin phosphorylation at Ser03, and the increase in cytoskeleton remodeling during the adhesion mechanism, possibly as a prerequisite to controlling cell proliferation and migration. This is mainly because CaneCPI-5 also caused the overexpression of the CDK2 gene, and greater migration of osteoblasts. Extracellular matrix remodeling was also evaluated in this study by investigating matrix metalloproteinase (MMP) activities. Our data showed that CaneCPI-5 overstimulates both MMP-2 and MMP-9 activities, and suggested that this cellular event could be related to osteoblast differentiation. Additionally, differentiation mechanisms were better evaluated by investigating Osterix and alkaline phosphatase (ALP) genes, and bone morphogenetic protein (BMP) signaling members. Altogether, our data showed that CaneCPI-5 can trigger biological mechanisms related to osteoblast differentiation, and broaden the perspectives for better exploring biotechnological approaches for bone disorders.


Assuntos
Cistatinas , Cisteína Proteases , Saccharum , Osteogênese/genética , Saccharum/genética , Diferenciação Celular/genética , Cistatinas/genética , Cistatinas/farmacologia , Cistatinas/metabolismo , Fatores de Transcrição/metabolismo , Cisteína Proteases/metabolismo , Osteoblastos , Proteína Morfogenética Óssea 2/metabolismo
7.
Restor Dent Endod ; 47(1): e11, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35284323

RESUMO

This study aimed to describe the outcomes of the GentleWave system (GW) (Sonendo) on root canal treatment. Published articles were collected from scientific databases (MEDLINE/PubMed platform, Web of Science, Scopus, Science Direct and Embase). A total of 24 studies were collected from August/2014 to July/2021, 20 in vitro and 4 clinical. GW System was not associated with extrusion of the irrigant, promoted faster organic dissolution than conventional syringe irrigation (CSI), passive ultrasonic irrigation (PUI) continuous ultrasonic irrigation (CUI) and EndoVac, reduced more bacterial DNA and biofilm than PUI and CUI, promoted higher penetration of sodium hypochlorite into dentinal tubules than PUI and CUI in vitro, and removed more intracanal medication than CSI and PUI. GW was able to remove pulp tissue and calcifications. Moreover, its ability to remove hard-tissue debris and smear layer was better than that of CSI, and its ability to remove root canal obturation residues was lower or similar to that of PUI, and similar to that of CSI and EndoVac. Regarding root canal obturation of minimally instrumented molar canals, GW was associated with high-quality obturation. Clinically, the success rate of endodontic treatment using GW was 97.3%, and the short-term postoperative pain in the GW group was not different from CSI. Further research, mainly clinical, is needed to establish whether GW has any advantages over other available irrigation methods.

8.
Restor Dent Endod ; 47(4): e35, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36518617

RESUMO

Although the success rates of microsurgery and micro-resurgery are very high, the influence of a recurrent perforation combined with radicular cyst remains unclear. A 21-year-old white female patient had a history of root perforation in a previously treated right maxillary lateral incisor. Analysis using cone-beam computed tomography (CBCT) revealed an extensive and well-defined periapical radiolucency, involving the buccal and palatal bone plate. The perforation was sealed with bioceramic material (Biodentine) in the pre-surgical phase. In the surgical phase, guided tissue regeneration (GTR) was performed by combining xenograft (lyophilized bovine bone) and autologous platelet-rich fibrin applied to the bone defect. The root-end preparation was done using an ultrasonic tip. The retrograde filling was performed using a bioceramic material (Biodentine). Histopathological analysis confirmed a radicular cyst. The patient returned to her referring practitioner to continue the restorative procedures. CBCT analysis after 1-year recall revealed another perforation in the same place as the first intervention, ultimately treated by micro-resurgery using the same protocol with GTR, and a bioceramic material (MTA Angelus). The 2-year recall showed healing and bone neoformation. In conclusion, endodontic micro-resurgery with GTR showed long-term favorable results when a radicular cyst and a recurrent perforation compromised the success.

9.
Braz Dent J ; 33(2): 1-11, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35508031

RESUMO

The aim was to assess the physicochemical properties and the penetration into dentinal tubules of calcium hypochlorite solution [Ca(OCl)2], with or without surfactants. The surfactants benzalkonium chloride, cetrimide, Tween 80 and Triton X-100 were mixed at different concentrations with sodium hypochlorite solution (NaOCl), Ca(OCl)2 and distilled water (control). Once the critical micellar concentration (CMC) of the surfactants in Ca(OCl)2 and NaOCl was determined, pH, free chlorine, surface tension and free calcium ions were evaluated. The penetration into dentinal tubules of NaOCl and Ca(OCl)2, with or without benzalkonium chloride and Triton X-100 [surfactants that promoted the lowest surface tension of Ca(OCl)2], was assessed using human premolars stained with crystal violet. The statistical tests were one-way ANOVA and Tukey's post-test, Kruskal-Wallis and Dunn's post-test, two-way ANOVA and Bonferroni's post-test, and t-test; depending on the assay. The addition of surfactants reduced the surface tension of NaOCl and Ca(OCl)2, and did not alter the pH or the free available chlorine of either solution. The addition of all surfactants increased the availability of free calcium ions in Ca(OCl)2, especially benzalkonium chloride. Ca(OCl)2 exhibited lower penetration into dentinal tubules than NaOCl, and the addition of surfactants did not improve the penetration of Ca(OCl)2, but did increase the penetration of NaOCl. It can be concluded that the addition of surfactants to Ca(OCl)2 did not increase the penetration into dentinal tubules, but it did promote lower surface tension, without changing the pH or free available chlorine values, and higher availability of free calcium ions in Ca(OCl)2.


Assuntos
Irrigantes do Canal Radicular , Hipoclorito de Sódio , Compostos de Benzalcônio , Cálcio , Compostos de Cálcio , Cloro , Humanos , Octoxinol , Irrigantes do Canal Radicular/química , Hipoclorito de Sódio/química , Tensoativos/química
10.
Aust Endod J ; 48(1): 91-97, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34310795

RESUMO

The aim was to assess the effect of XP-endo Finisher (XPF) on multispecies biofilm removal, in comparison with passive ultrasonic irrigation (PUI) and conventional syringe irrigation (CSI), by scanning electron microscope (SEM). Fifty mandibular first premolars were instrumented, longitudinally sectioned. The split halves were incubated for 4 days with a broth obtained from three bacteria strains: Enterococcus faecalis, Eikenella corrodens and Streptococcus anginosus. Subsequently, the re-approximated split halves were irrigated with 4% sodium hypochlorite (NaOCl) or water using CSI, and the final irrigation protocols were CSI with 4% NaOCl (CSI+4%NaOCl), PUI+4%NaOCl, XPF+4%NaOCl and CSI+water. The analysis of biofilm removal was performed using SEM images. There were no differences between PUI and XPF (P > 0.05), and both groups promoted higher biofilm removal than CSI+4%NaOCl and CSI+water groups (P < 0.05). It can be concluded the multispecies biofilm removal was significantly improved using XPF and PUI when compared to CSI.


Assuntos
Cavidade Pulpar , Irrigantes do Canal Radicular , Biofilmes , Cavidade Pulpar/microbiologia , Microscopia Eletrônica de Varredura , Irrigantes do Canal Radicular/uso terapêutico , Hipoclorito de Sódio/uso terapêutico , Irrigação Terapêutica/métodos , Ultrassom , Água
11.
J Endod ; 48(12): 1502-1510.e1, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36243176

RESUMO

INTRODUCTION: The research for alternative irrigating solutions is ongoing, since no "ideal" solution has yet been found. Octenidine dihydrochloride (OCT) has been indicated as an endodontic irrigant because it has adequate antimicrobial and biological properties. The present study aimed to assess the effects of OCT on proliferation, migration, and induction of the osteogenic phenotype of stem cells from human dental pulp and apical papilla. METHODS: Cells were collected from human third molars and exposed to different doses of OCT, chlorhexidine (CHX), sodium hypochlorite (NaOCl), and ethylenediaminetetraacetic acid (EDTA) to determine cell viability by alamarBlue assay; proliferation by bromodeoxyuridine incorporation; migration by the Transwell assay; alkaline phosphatase activity by thymolphthalein release; and production of mineralized nodules by alizarin red staining. The results were analyzed by 1- or 2-way analysis of variance and Tukey (α = .05). RESULTS: CHX promoted lower cell viability, followed by OCT, NaOCl, and EDTA, especially at intermediate doses (P < .05). Cells exposed to CHX had less proliferation than the other groups (P < .05). The Transwell assay revealed no differences among OCT, EDTA, and culture medium (control group) (P > .05). OCT and EDTA induced greater migration than CHX and NaOCl (P < .05). OCT and EDTA induced higher alkaline phosphatase activity than NaOCl and CHX (P < .05). No difference was detected among the groups using alizarin red staining (P > .05). CONCLUSIONS: OCT induced high migration, proliferation, and alkaline phosphatase activity of stem cells from human dental pulp and apical papilla, which could be advantageous for regenerative endodontic procedures.


Assuntos
Osteogênese , Irrigantes do Canal Radicular , Humanos , Irrigantes do Canal Radicular/farmacologia , Ácido Edético/farmacologia , Fosfatase Alcalina , Polpa Dentária , Hipoclorito de Sódio/farmacologia , Clorexidina/farmacologia , Células-Tronco , Proliferação de Células , Papila Dentária
12.
J Appl Oral Sci ; 30: e20210575, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35352771

RESUMO

OBJECTIVE: To assess the effects of different peracetic acid (PAA) formulations on smear layer (SL) removal, dentine erosion, cytotoxicity, and antibiofilm activity. METHODOLOGY: SL removal and dentine erosion were assessed using 90 premolars, distributed into six groups, according to final irrigation: PAA formulations (1% Sigma, 1% Bacterend OX, 1% Arposept, and 0.09-0.15% Anioxyde), 17% ethylenediaminetetraacetic acid (EDTA), and water (control). Cytotoxicity was assessed by methyl-thiazol-tetrazolium (MTT) and neutral red assays. Antibacterial and antibiofilm effectiveness was evaluated against Enterococcus faecalis. For cytotoxicity and antibiofilm activity assessment, the 2.5% NaOCl was also included. RESULTS: EDTA, Sigma, and Bacterend OX removed more SL than Arposept, Anioxyde, and water (p<0.05). EDTA caused more severe dentine erosion than Sigma and Bacterend OX (p<0.05). Sigma and Bacterend OX had higher cytotoxicity than the other solutions (p<0.05). NaOCl, Bacterend OX, Sigma, and Anioxyde significantly reduced E. faecalis colony-forming units (CFU) (p<0.05). The 2.5% NaOCl solution promoted greater biofilm biomass reduction (p<0.05) than the other solutions. All PAA formulations promoted greater biomass reduction than 17% EDTA (p<0.05). CONCLUSIONS: Although Sigma and Bacterend OX had higher cytotoxicity, they had a SL removal capability similar to that of EDTA, were as effective as NaOCl against E. faecalis biofilm, and promoted less dentine erosion than EDTA. Arposept and Anioxyde failed to remove the SL, had lower cytotoxicity, and showed less bacterial activity than NaOCl.


Assuntos
Camada de Esfregaço , Biofilmes , Dentina , Humanos , Ácido Peracético/farmacologia , Irrigantes do Canal Radicular/farmacologia , Hipoclorito de Sódio/farmacologia
13.
J Endod ; 47(12): 1947-1952, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34626612

RESUMO

Extrusion of sodium hypochlorite (NaOCl) is a very rare accident with the most common complications including pain, swelling, and hematoma. It can occur even if procedural guidelines, predisposing conditions, and risk factors are taken into consideration. A 59-year-old female patient was admitted to the endodontics department to treat a left maxillary first premolar (World Dental Federation tooth 24). The medical history included osteoporosis and systemic medication with alendronate. Initially, the diagnosis was "symptomatic irreversible pulpitis" with "normal apical tissues." During instrumentation of the buccal canal, accidental extrusion of 2.5% NaOCl occurred into the periapical tissues, resulting from misinterpretation of the working length, and caused severe pain and bleeding. The canal was immediately flushed using copious irrigation with saline solution. An analgesic and corticosteroid were prescribed. At 3 and 7 days, ecchymosis and slight hematoma were observed extraorally in the area of the affected tooth and an intraoral ulceration at the apex of the affected tooth. At 15 days, minimal signs of ecchymosis were observed, and the treatment was resumed. At 30 days after the accident, there was complete remission of the sequelae. The clinical, radiographic, and tomographic assessment after 1 month, 1 year, and 8 years showed favorable case evolution. During the 8-year follow-up, the patient maintained the systemic use of alendronate. It can be concluded that NaOCl extrusion is an accident that causes patients and clinicians to experience an unpleasant consequence. The radiographic working length should always be determined carefully. A successful outcome can be achieved in patients who take alendronate.


Assuntos
Alendronato , Hipoclorito de Sódio , Acidentes , Alendronato/efeitos adversos , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Irrigantes do Canal Radicular/efeitos adversos , Preparo de Canal Radicular , Hipoclorito de Sódio/efeitos adversos
14.
Braz Oral Res ; 35: e074, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34644728

RESUMO

The aim of this study was to assess the influence of micro-computed tomography (micro-CT) voxel size on dentinal microcrack detection after root canal preparation using rotary heat-treated nickel-titanium files. Curved mesial root canals (n = 24) of mandibular molars were prepared using ProDesign Logic 30/.05 (PDL) or HyFlex EDM 25/.08 (HEDM). The specimens were scanned by micro-CT at 5 µm voxel size before and after root canal preparation. The percentage of microcracks was evaluated in images at 5, 10 and 20 µm voxel size, by two examiners at two moments. The Kappa and McNemar tests (α = 0.05) were used. The percentage of dentinal microcracks was similar before and after PDL and HEDM preparations, at 10 and 20 µm (p > 0.05). HEDM showed a higher percentage of dentinal microcracks in the middle third at 5 µm after preparation (p < 0.05). The detection of dentinal microcracks before and after instrumentation using PDL was more accurate at 5 µm than at 20 µm, in all thirds (p < 0.05). Within the limitations of this ex vivo study, as expected, the results showed that different resolutions influence the micro-CT analysis of microcracks. The highest accuracy in detecting microcracks was observed for analyses performed at 5 µm voxel size. HyFlex EDM caused even more microcracks to develop in the middle third, detectable only by visualization of images made at 5 µm voxel size.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Microtomografia por Raio-X
15.
Microsc Res Tech ; 83(4): 375-380, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31833180

RESUMO

The aim was to assess the effects of 1% peracetic acid (PAA) as a single endodontic irrigant on microhardness, roughness, and erosion of root canal dentin, compared with 2.5% sodium hypochlorite (NaOCl) and with 2.5% NaOCl combined with 17% EDTA. Forty human, single-rooted tooth hemisections were submitted to Knoop microhardness test, before and after the following irrigation protocols: PAA = 1% PAA; NaOCl = 2.5% NaOCl; NaOCl-EDTA-NaOCl = 2.5% NaOCl +17% EDTA +2.5% NaOCl; and SS = saline. Another 40 roots were instrumented, irrigated with the same protocols, and sectioned longitudinally. The roughness analysis was performed on the mesial section using a confocal laser scanning microscope, whereas erosion was analyzed on each third of the distal section, using a scanning electron microscope. The data were analyzed using ANOVA and Tukey post-tests, and Kruskal-Wallis and Dunn post-tests (α = .05). The PAA and NaOCl-EDTA-NaOCl groups showed no significant differences (p > .05); both promoted reduction in microhardness and increase in roughness, compared with the NaOCl and SS groups (p < .05). NaOCl-EDTA-NaOCl promoted higher erosion in the cervical and middle thirds than the other groups (p < .05); there was no difference among PAA, NaOCl, and SS (p > .05). There was also no difference among the groups regarding the apical third (p > .05). PAA used as a single endodontic irrigant caused reduction in root canal dentin microhardness and increase in roughness in a similar way to NaOCl-EDTA-NaOCl; however, PAA caused less erosion than NaOCl-EDTA-NaOCl.


Assuntos
Cavidade Pulpar/efeitos dos fármacos , Dentina/efeitos dos fármacos , Ácido Peracético/farmacologia , Irrigantes do Canal Radicular/farmacologia , Dentina/patologia , Humanos , Microscopia Eletrônica de Varredura , Preparo de Canal Radicular , Hipoclorito de Sódio/farmacologia , Propriedades de Superfície , Erosão Dentária , Raiz Dentária/efeitos dos fármacos
16.
Restor Dent Endod ; 45(4): e47, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33294412

RESUMO

OBJECTIVES: The aim of this study was to assess the physicochemical properties, cytotoxicity and penetration into dentinal tubules of ChlorCid™ Surf (3% sodium hypochlorite [NaOCl] with surfactant) in comparison to ChlorCid™ (3% NaOCl without surfactant). MATERIALS AND METHODS: The physicochemical properties evaluated were pH, surface tension, free available chlorine (FAC) and contact angle. Cytotoxicity was evaluated in L929 fibroblasts exposed to the solutions by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide and neutral red assays. Assessment of penetration into dentinal tubules was performed by staining single-rooted permanent human teeth with crystal violet (n = 9), which were irrigated with the solutions and analyzed in cervical, middle and apical segments. Data were analyzed by one-way analysis of variance (ANOVA) and Tukey's post-test, 2-way ANOVA and Bonferroni's post-test or t-test (α = 0.05). RESULTS: ChlorCid™ Surf and ChlorCid™ FAC values were close to those indicated by the manufacturer. ChlorCid™ Surf showed lower surface tension and contact angle on dentin, and higher pH than ChlorCid™ (p < 0.05). The penetration of ChlorCid™ Surf was higher in cervical and middle segments, compared with ChlorCid™ (p < 0.05). There was no difference in irrigant cytotoxicity (p > 0.05). CONCLUSIONS: ChlorCid™ Surf showed lower surface tension, lower contact angle on root canal dentin, higher penetration into dentinal tubules and more alkaline pH, compared with ChlorCid™. However, both solutions showed similar cytotoxicity and FAC content.

17.
Braz Dent J ; 31(5): 511-515, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33146335

RESUMO

This study aimed to assess the physicochemical properties of a repair material in the Brazilian market, BioMTA, in comparison to other two materials currently in use (Biodentine and MTA Angelus). The initial setting time was evaluated using Gillmore needle. The pH was measured with a pH-meter after 24 h, 3, 7, 14 and 21 days. The radiopacity was determined using the equivalence in millimeters of aluminum (mm Al) from digitized occlusal radiographs. Solubility was determined after immersion in water for 7 days. The data were analyzed by one-way ANOVA and Tukey tests (a=0.05). The BioMTA initial setting time (5.2 min) was lower than the other materials (p<0.05). All materials showed an alkaline pH at 21 days. At 24 h, BioMTA was the most alkaline material (p<0.05); and at 3, 7, 14 and 21 days there was no difference between BioMTA and Biodentine (p>0.05), both being more alkaline than MTA Angelus (p<0.05). The radiopacity of BioMTA (4.2 mm Al) was significantly higher compared to Biodentine (p<0.05) and lower than MTA Angelus (p<0.05). The solubility of the materials was -4.2%, -1.6% and 4.1% for BioMTA, MTA Angelus and Biodentine, respectively, with a significant difference between them (p<0.05). Therefore, it can be concluded that BioMTA displayed a shorter setting time, an alkaline pH, a higher radiopacity, and a gain in mass.


Assuntos
Materiais Restauradores do Canal Radicular , Silicatos , Resinas Acrílicas , Compostos de Alumínio , Brasil , Compostos de Cálcio , Combinação de Medicamentos , Teste de Materiais , Óxidos , Solubilidade , Água
18.
Braz Oral Res ; 34: e080, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32696910

RESUMO

The aims of the present study were to compare conventional radiography, radiographs digitized with a scanner or photographic camera, and digital radiography, used to evaluate the radiopacity of endodontic materials, and to compare the accuracy of linear and quadratic models used to convert radiopacity values to equivalent millimeters of aluminum (mm Al). Specimens of AH Plus, Endofill, Biodentine and BioMTA materials (n = 8) were radiographed next to an aluminum step-wedge using radiographic films and digital radiography systems (FONA CMOS sensor, Kodak CMOS sensor and photosensitive phosphor plate-PSP). Conventional radiographs were digitized using a scanner or photographic digital camera. Digital images of all the radiographic systems were evaluated using dedicated software. Optical density units (ODU) of the specimens and the aluminum step-wedge were evaluated by a photo-densitometer (PTDM), used in conventional radiographs. The radiopacity in equivalent mm Al of the materials was determined by linear and quadratic models, and the coefficients of determination (R2) values were calculated for each model. Radiopacity of the materials ranged from -9% to 25% for digital systems and digitized radiographs, compared to the PTDM (p < 0.05). The R2 values of the quadratic model were higher than those of the linear model. In conclusion, the FONA CMOS sensor showed the lowest radiopacity variability of the methodologies used, compared with the PTDM, except for the BioMTA group (higher than PTDM). The quadratic model showed higher R2 values than the linear model, thus indicating better accuracy and possible adoption to evaluate the radiopacity of endodontic materials.


Assuntos
Alumínio , Teste de Materiais , Radiografia Dentária Digital , Filme para Raios X
19.
Braz Dent J ; 30(3): 213-219, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31166398

RESUMO

The aim of this study was to assess cytotoxicity and cell migration of calcium hypochlorite [Ca(OCl)2] and octenidine hydrochloride - OCT (Octenisept®, Schülke & Mayr, Norderstedt, Germany) in L929 and human periodontal ligament (hPDL) cells. The cells were exposed to different doses of different solutions: 2.5% and 5% Ca(OCl)2, 0.1% OCT, 2.5% NaOCl and 2% CHX for 10 min. Cell viability was assessed by methyl-thiazol-tetrazolium (MTT) and neutral red (NR) assays, and cell migration was determined by wound-healing assay. Statistical analysis was performed by two-way ANOVA and Bonferroni tests (α=0.05). The MTT and NR assays revealed that 0.1% OCT was less cytotoxic in hPDL cells (p<0.05), followed by 2% CHX and 2.5% Ca(OCl)2 (p<0.05). There was no significant difference between 2.5% NaOCl and 5% Ca(OCl)2 (p>0.05), but these solutions showed greater cytotoxicity than the others. The result was the same for L929 cells, except that there was no significant difference between 2% CHX and 2.5% Ca(OCl)2 (p>0.05). Wound-healing assay in L929 and hPDL cells showed that cell migration of 0.1% OCT, 2% CHX and 2.5% Ca(OCl)2 groups was higher than 5% Ca(OCl)2 and 2.5% NaOCl groups at 24 h (p<0.05). In conclusion, 0.1% OCT had lower cytotoxicity in tested cell lines than CHX, Ca(OCl)2 and NaOCl. Cell migration was higher for 0.1% OCT, 2% CHX and 2.5% Ca(OCl)2. Therefore, in terms of cytotoxicity, OCT and Ca(OCl)2 have the potential to be used as root canal irrigants.


Assuntos
Ligamento Periodontal , Hipoclorito de Sódio , Compostos de Cálcio , Clorexidina , Humanos , Iminas , Piridinas , Irrigantes do Canal Radicular
20.
Microsc Res Tech ; 81(6): 523-527, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29436057

RESUMO

The aim of this study was to assess the cleaning capacity of the octenidine hydrochloride (OCT) used as root canal irrigant by scanning electron microscopy (SEM) analysis. Sixty human unirradicular extracted teeth were randomly distributed in 6 groups (n = 10) according to irrigant solutions which were used during root canal preparation: G1, 0.1% OCT; G2, 2% chlorhexidine (CHX); G3, 2.5% sodium hypochlorite (NaOCl); G4, OCT + 17% ethylenediaminetetraacetic acid (EDTA); G5, 2.5% NaOCl + 17% EDTA and G6, distilled water. All specimens were instrumented with ProTaper system up to F4. Teeth were sectioned and prepared for SEM. The smear layer was evaluated using a 5-score system and the data were analyzed by Kruskal-Wallis and Dunn (α = 0.05). In all root canal thirds there was no significant difference between OCT, CHX, NaOCl, and water groups (p > .05), and these groups showed higher smear layer values than NaOCl + EDTA and OCT + EDTA groups (p < .05). There was no significant difference between NaOCl + EDTA and OCT + EDTA groups (p > .05). It was concluded that OCT used as a single root canal irrigant presented poor cleaning capacity and could be used in association with a final irrigation with EDTA to obtain smear layer removal.


Assuntos
Clorexidina/farmacologia , Ácido Edético/farmacologia , Piridinas/farmacologia , Irrigantes do Canal Radicular/farmacologia , Preparo de Canal Radicular/métodos , Hipoclorito de Sódio/farmacologia , Dente Pré-Molar , Cavidade Pulpar , Humanos , Iminas , Microscopia Eletrônica de Varredura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA