1.
Sensors (Basel) ; 22(3)2022 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-35161715

RESUMO

In biosensing applications, the exploitation of organic transistors gated via a liquid electrolyte has increased in the last years thanks to their enormous advantages in terms of sensitivity, low cost and power consumption. However, a practical aspect limiting the use of these devices in real applications is the contamination of the organic material, which represents an obstacle for the realization of a portable sensing platform based on electrolyte-gated organic transistors (EGOTs). In this work, a novel contamination-free microfluidic platform allowing differential measurements is presented and validated through finite element modeling simulations. The proposed design allows the exposure of the sensing electrode without contaminating the EGOT device during the whole sensing tests protocol. Furthermore, the platform is exploited to perform the detection of bovine serum albumin (BSA) as a validation test for the introduced differential protocol, demonstrating the capability to detect BSA at 1 pM concentration. The lack of contamination and the differential measurements provided in this work can be the first steps towards the realization of a reliable EGOT-based portable sensing instrument.


Assuntos
Técnicas Biossensoriais , Microfluídica , Eletrodos , Eletrólitos , Transistores Eletrônicos
2.
Small ; 15(41): e1902332, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31441219

RESUMO

The perspective of downscaling organic electrochemical transistors (OECTs) in the nanorange is approached by depositing poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) on electrodes with a nanogap designed and fabricated by electromigration induced break junction (EIBJ) technique. The electrical response of the fabricated devices is obtained by acquiring transfer characteristics in order to clarify the specific main characteristics of OECTs with sub-micrometer-sized active channels (nanogap-OECTs). On the basis of their electrical response to different scan times, the nanogap-OECT shows a maximum transconductance unaffected upon changing scan times in the time window from 1 s to 100 µs, meaning that fast varying signals can be easily acquired with unchanged amplifying performance. Hence, the scaling down of the channel size to the nanometer scale leads to a geometrical paradigm that minimizes effects on device response due to the cationic diffusion into the polymeric channel. A comprehensive study of these features is carried out by an electrochemical impedance spectroscopy (EIS) study, complemented by a quantitative analysis made by equivalent circuits. The propagation of a redox front into the polymer bulk due to ionic diffusion also known as the "intercalation pseudocapacitance" is identified as a limiting factor for the transduction dynamics.

3.
Sensors (Basel) ; 19(20)2019 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-31627267

RESUMO

In-liquid biosensing is the new frontier of health and environment monitoring. A growing number of analytes and biomarkers of interest correlated to different diseases have been found, and the miniaturized devices belonging to the class of biosensors represent an accurate and cost-effective solution to obtaining their recognition. In this study, we investigate the effect of the solvent and of the substrate modification on thin films of organic semiconductor Poly(3-hexylthiophene) (P3HT) in order to improve the stability and electrical properties of an Electrolyte Gated Organic Field Effect Transistor (EGOFET) biosensor. The studied surface is the relevant interface between the P3HT and the electrolyte acting as gate dielectric for in-liquid detection of an analyte. Atomic Force Microscopy (AFM) and X-ray Photoelectron Spectroscopy (XPS) characterizations were employed to study the effect of two solvents (toluene and 1,2-dichlorobenzene) and of a commercial adhesion promoter (Ti Prime) on the morphological structure and electronic properties of P3HT film. Combining the results from these surface characterizations with electrical measurements, we investigate the changes on the EGOFET performances and stability in deionized (DI) water with an Ag/AgCl gate electrode.


Assuntos
Técnicas Biossensoriais , Monitoramento Ambiental , Compostos Organosselênicos/química , Solventes/química , Eletrodos , Microscopia de Força Atômica , Semicondutores , Propriedades de Superfície , Água/química
4.
Anal Chem ; 88(24): 12330-12338, 2016 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-28193067

RESUMO

Biorecognition is a central event in biological processes in the living systems that is also widely exploited in technological and health applications. We demonstrate that the Electrolyte Gated Organic Field Effect Transistor (EGOFET) is an ultrasensitive and specific device that allows us to quantitatively assess the thermodynamics of biomolecular recognition between a human antibody and its antigen, namely, the inflammatory cytokine TNFα at the solid/liquid interface. The EGOFET biosensor exhibits a superexponential response at TNFα concentration below 1 nM with a minimum detection level of 100 pM. The sensitivity of the device depends on the analyte concentration, reaching a maximum in the range of clinically relevant TNFα concentrations when the EGOFET is operated in the subthreshold regime. At concentrations greater than 1 nM the response scales linearly with the concentration. The sensitivity and the dynamic range are both modulated by the gate voltage. These results are explained by establishing the correlation between the sensitivity and the density of states (DOS) of the organic semiconductor. Then, the superexponential response arises from the energy-dependence of the tail of the DOS of the HOMO level. From the gate voltage-dependent response, we extract the binding constant, as well as the changes of the surface charge and the effective capacitance accompanying biorecognition at the electrode surface. Finally, we demonstrate the detection of TNFα in human-plasma derived samples as an example for point-of-care application.


Assuntos
Técnicas Biossensoriais/instrumentação , Transistores Eletrônicos , Fator de Necrose Tumoral alfa/sangue , Capacitância Elétrica , Desenho de Equipamento , Humanos , Dispositivos Lab-On-A-Chip , Semicondutores , Termodinâmica
5.
Sensors (Basel) ; 17(1)2016 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-28042839

RESUMO

In the sensors field the active sensing material frequently needs a controlled temperature in order to work properly. In microsystems technology, micro-machined hotplates represent a platform consisting of a thin suspended membrane where the sensing material can be deposited, usually integrating electrical stimuli and temperature readout. The micro-hotplate ensures a series of advantages such as miniaturized size, fast response, high sensitivity, low power consumption and selectivity for chemical sensing. This work compares the coplanar and the buried approach for the micro-hotplate heaters design with the aim to optimize the fabrication process and to propose a guideline for the choice of the suitable design with respect to the applications. In particular, robust Finite Element Method (FEM) models are set up in order to predict the electrical and thermal behavior of the micro-hotplates. The multiphysics approach used for the simulation allows to match as close as possible the actual device to the predictive model: geometries, materials, physics have been carefully linked to the fabricated devices to obtain the best possible accuracy. The materials involved in the fabrication process are accurately selected in order to improve the yield of the process and the performance of the devices. The fabricated micro-hotplates are able to warm the active region up to 400 °C (with a corresponding power consumption equal to 250 mW @ 400 °C) with a uniform temperature distribution in the buried micro-hotplate and a controlled temperature gradient in the coplanar one. A response time of about 70 ms was obtained on the virtual model, which perfectly agrees with the one measured on the fabricated device. Besides morphological, electrical and thermal characterizations, this work includes reliability tests in static and dynamic modes.

6.
Biochim Biophys Acta ; 1830(9): 4374-80, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23295972

RESUMO

BACKGROUND: Organic electrochemical transistors (OECTs), which are becoming more and more promising devices for applications in bioelectronics and nanomedicine, are proposed here as ideally suitable for sensing and real time monitoring of liposome-based structures. This is quite relevant since, currently, the techniques used to investigate liposomal structures, their stability in different environments as well as drug loading and delivery mechanisms, operate basically off-line and/or with pre-prepared sampling. METHODS: OECTs, based on the PEDOT:PSS conductive polymer, have been employed as sensors of liposome-based nanoparticles in electrolyte solutions to assess sensitivity and monitoring capabilities based on ion-to-electron amplified transduction. RESULTS: We demonstrate that OECTs are very efficient, reliable and sensitive devices for detecting liposome-based nanoparticles on a wide dynamic range down to 10(-5)mg/ml (with a lowest detection limit, assessed in real-time monitoring, of 10(-7)mg/ml), thus matching the needs of typical drug loading/drug delivery conditions. They are hence particularly well suited for real-time monitoring of liposomes in solution. Furthermore, OECTs are shown to sense and discriminate successive injection of different liposomes, so that they could be good candidates in quality-control assays or in the pharmaceutical industry. GENERAL SIGNIFICANCE: Drug loading and delivery by liposome-based structures is a fast growing and very promising field that will strongly benefit from real-time, highly sensitive and low cost monitoring of their dynamics in different pharma and biomedical environments, with a particular reference to the pharmaceutical and production processes, where a major issue is monitoring and measuring the formation and concentration of liposomes and the relative drug load. The demonstrated ability to sense and monitor complex bio-structures, such as liposomes, paves the way for very promising developments in biosensing and nanomedicine. This article is part of a Special Issue entitled Organic Bioelectronics-Novel Applications in Biomedicine.


Assuntos
Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Lipossomos/química , Microfluídica/instrumentação , Microfluídica/métodos , Transistores Eletrônicos , Nanomedicina/instrumentação , Nanomedicina/métodos , Nanopartículas/química , Polímeros/química , Poliestirenos/química , Soluções/química , Tiofenos/química
7.
Biomed Microdevices ; 16(5): 661-70, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24831451

RESUMO

In this work a polymer lab-on-a-chip (LOC), fabricated through MEMS technology, was employed to execute a genetic protocol for the Single Nucleotide Polymorphisms (SNPs) detection. The LOC was made in Poly (methyl methacrylate) (PMMA) and has two levels: the lower one for the insertion and mixing of the reagents, the upper one for the interfacing with the DNA microarray chip. The hereditary hearing loss was chosen as case of study, since the demand for testing such a particular disorder is high and genetics behind the condition is quite clear. The Arrayed Primer EXtension (APEX) genetic protocol was implemented on the LOC to analyze the SNPs. A low density (for detection of up to 10 mutations) and a high density microarray chips (for detection of 245 mutations in 12 genes), containing the primers for the extension, were employed to carry out the APEX reaction on the LOC. Both the microarray chips provide a signal to noise ratio and efficiency comparable with a detection obtained in a conventional protocol in standard conditions. Moreover, significant reduction of the employed PCR volume (from 30 µL to 10 µL) was obtained using the low density chip.


Assuntos
Primers do DNA/química , Dispositivos Lab-On-A-Chip , Análise de Sequência com Séries de Oligonucleotídeos/instrumentação , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Polimorfismo de Nucleotídeo Único , Humanos
8.
Micromachines (Basel) ; 15(6)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38930648

RESUMO

MEMS devices are more and more commonly used as sensors, actuators, and microfluidic devices in different fields like electronics, opto-electronics, and biomedical engineering. Traditional fabrication technologies cannot meet the growing demand for device miniaturisation and fabrication time reduction, especially when customised devices are required. That is why additive manufacturing technologies are increasingly applied to MEMS. In this review, attention is focused on the Italian scenario in regard to 3D-printed MEMS, studying the techniques and materials used for their fabrication. To this aim, research has been conducted as follows: first, the commonly applied 3D-printing technologies for MEMS manufacturing have been illustrated, then some examples of 3D-printed MEMS have been reported. After that, the typical materials for these technologies have been presented, and finally, some examples of their application in MEMS fabrication have been described. In conclusion, the application of 3D-printing techniques, instead of traditional processes, is a growing trend in Italy, where some exciting and promising results have already been obtained, due to these new selected technologies and the new materials involved.

9.
Front Bioeng Biotechnol ; 12: 1346660, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38646009

RESUMO

Several diseases affect the alveoli, and the efficacy of medical treatments and pharmaceutical therapies is hampered by the lack of pre-clinical models able to recreate in vitro the diseases. Microfluidic devices, mimicking the key structural and compositional features of the alveoli, offer several advantages to medium and high-throughput analysis of new candidate therapies. Here, we developed an alveolus-on-a-chip recapitulating the microanatomy of the physiological tissue by including the epithelium, the fibrous interstitial layer and the capillary endothelium. A PDMS device was obtained assembling a top layer and a bottom layer obtained by replica molding. A polycaprolactone/gelatin (PCL-Gel) electrospun membrane was included within the two layers supporting the seeding of 3 cell phenotypes. Epithelial cells were grown on a fibroblast-laden collagen hydrogel located on the top side of the PCL-Gel mats while endothelial cells were seeded on the basolateral side of the membrane. The innovative design of the microfluidic device allows to replicate both cell-cell and cell-extracellular matrix interactions according to the in vivo cell arrangement along with the establishment of physiologically relevant air-liquid interface conditions. Indeed, high cell viability was confirmed for up to 10 days and the formation of a tight endothelial and epithelial barrier was assessed by immunofluorescence assays.

10.
Langmuir ; 29(50): 15711-8, 2013 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-24266688

RESUMO

In this work, photocurable perfluoropolyethers (PFPEs) have been used for the fabrication of microfluidic devices by a direct photolithographic process. During this mask-assisted photopolymerization technique, the material is directly photopolymerized in the presence of a mask, avoiding the use of a master. We demonstrate the high level of control in transferring micropattern features with high density, a minimum transferred size of 15 µm, a high aspect ratio (at least up to 6.5), and complex shapes useful for microfluidic applications. Moreover, we successfully apply this technology to fabricate sealed devices; the fabrication time scale for the overall process is around 5 min. The devices are able to withstand a flow pressure of up to 3.8 bar, as required for most microfluidics. Finally, the devices are tested with a model reaction employing organic solvents.

11.
Lab Chip ; 23(8): 2106-2112, 2023 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-36943724

RESUMO

Deterministic lateral displacement (DLD) is a passive separation method that separates particles by hydrodynamic size. This label-free method is a promising technique for cell separation because of its high size resolution and insensitivity to flow rate. Development of capillary-driven microfluidic technologies allows microfluidic devices to be operated without any external power for fluid pumping, lowering their total cost and complexity. Herein, we develop and test a DLD-based particle and cell sorting method that is driven entirely by capillary pressure. We show microchip self-filling, flow focusing, flow stability, and capture of separated particles. We achieve separation efficiency of 92% for particle-particle separation and more than 99% efficiency for cell-particle separation. The high performance of driven flow and separation along with simplicity of the operation and setup make it a valuable candidate for point-of-care devices.

12.
Biosensors (Basel) ; 13(4)2023 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-37185523

RESUMO

Transglutaminase 2 (TG2) is a ubiquitously expressed member of the transglutaminase family with Ca2+-dependent protein crosslinking activity. Its subcellular localization is crucial in determining its function, and indeed, TG2 is found in the extracellular matrix, mitochondria, recycling endosomes, plasma membrane, cytosol, and nucleus because it is associated with cell growth, differentiation, and apoptosis. It is involved in several pathologies, such as celiac disease, cardiovascular, hepatic, renal, and fibrosis diseases, carrying out opposite functions of up and down regulation in the progression of the same pathology. Therefore, this fine regulation requires a very sensitive and specific method of identification of TG2, which is to be detected in very small quantities in a deregulated condition. Here, we demonstrate the possibility of detecting TG2 down to attomolar concentration by using organic electrochemical transistors driven by gold electrodes functionalized with anti-TG2 antibodies. In particular, a direct correlation between the TG2 concentration and the transistor transconductance values, as extracted from typical transfer curves, was found. Overall, our findings highlight the potentialities of this new biosensing approach for the detection of TG2 in the context of pathological diseases, offering a rapid and cost-effective alternative to traditional methods.


Assuntos
Proteínas de Ligação ao GTP , Proteína 2 Glutamina gama-Glutamiltransferase , Proteínas de Ligação ao GTP/metabolismo , Transglutaminases/metabolismo , Fígado , Apoptose
13.
Micromachines (Basel) ; 14(2)2023 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-36838160

RESUMO

In recent years, studies concerning Organic Bioelectronics have had a constant growth due to the interest in disciplines such as medicine, biology and food safety in connecting the digital world with the biological one. Specific interests can be found in organic neuromorphic devices and organic transistor sensors, which are rapidly growing due to their low cost, high sensitivity and biocompatibility. This trend is evident in the literature produced in Italy, which is full of breakthrough papers concerning organic transistors-based sensors and organic neuromorphic devices. Therefore, this review focuses on analyzing the Italian production in this field, its trend and possible future evolutions.

14.
Biosensors (Basel) ; 13(7)2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37504137

RESUMO

The global COVID-19 pandemic has had severe consequences from the social and economic perspectives, compelling the scientific community to focus on the development of effective diagnostics that can combine a fast response and accurate sensitivity/specificity performance. Presently available commercial antigen-detecting rapid diagnostic tests (Ag-RDTs) are very fast, but still face significant criticisms, mainly related to their inability to amplify the protein signal. This translates to a limited sensitive outcome and, hence, a reduced ability to hamper the spread of SARS-CoV-2 infection. To answer the urgent need for novel platforms for the early, specific and highly sensitive detection of the virus, this paper deals with the use of organic electrochemical transistors (OECTs) as very efficient ion-electron converters and amplifiers for the detection of spike proteins and their femtomolar concentration. The electrical response of the investigated OECTs was carefully analyzed, and the changes in the parameters associated with the transconductance (i.e., the slope of the transfer curves) in the gate voltage range between 0 and 0.3 V were found to be more clearly correlated with the spike protein concentration. Moreover, the functionalization of OECT-based biosensors with anti-spike and anti-nucleocapside proteins, the major proteins involved in the disease, demonstrated the specificity of these devices, whose potentialities should also be considered in light of the recent upsurge of the so-called "long COVID" syndrome.


Assuntos
Técnicas Biossensoriais , COVID-19 , Humanos , COVID-19/diagnóstico , Glicoproteína da Espícula de Coronavírus , Pandemias , SARS-CoV-2 , Transistores Eletrônicos , Proteínas
15.
Biomater Sci ; 11(1): 208-224, 2022 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-36420859

RESUMO

Pancreatic ductal adenocarcinoma (PDAC) mainly develops in the head of the pancreas, within the acino-ductal unit composed of acinar and ductal cells surrounded by pancreatic stellate cells (PSCs). PSCs strongly influence the tumor microenvironment by triggering an intense stromal deposition, which plays a key role in tumor progression and limits drug perfusion. We have developed a microfluidic in vitro model recreating the in vivo tumor-stroma crosstalk to replicate the steps of PDAC evolution towards the establishment of an efficient in vitro platform for innovative therapy validation. The multilayer PDAC-on-chip was designed to culture the PDAC cells and the PSCs embedded in a type I collagen gel in the top and bottom layers, respectively. The presence of a biomimetic nanofibrous membrane in the middle of the chip permits the control of interactions between the two cell lines and the easy analysis of the effects of the crosstalk on cell behavior. First, the PDAC-stromal cell relationship was evaluated under co-culture conditions on 24-well inserts including the PCL/Gel electrospun membrane. This simplified model shows that human fibroblasts change their morphology and secrete larger amounts of IL-6 cytokines in the presence of tumor cells, confirming the activation of stromal cells under co-culture. Then, the PDAC-on-chip system was validated by demonstrating that human fibroblasts seeded in a 3D collagen matrix in the bottom microchannel also change to a myofibroblast-like shape with increased expression of α-SMA and secrete larger amounts of IL-6 cytokines. This microfluidic system is suitable for the evaluation of drug efficacy and serves as a powerful tool for understanding the early evolution steps of PDAC.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Humanos , Interleucina-6 , Neoplasias Pancreáticas/tratamento farmacológico , Carcinoma Ductal Pancreático/patologia , Pâncreas/metabolismo , Microambiente Tumoral , Linhagem Celular Tumoral , Neoplasias Pancreáticas
16.
Biomed Microdevices ; 13(1): 19-27, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20827509

RESUMO

Lab-on-chips (LOCs) are critical systems that have been introduced to speed up and reduce the cost of traditional, laborious and extensive analyses in biological and biomedical fields. These ambitious and challenging issues ask for multi-disciplinary competences that range from engineering to biology. Starting from the aim to integrate microarray technology and microfluidic devices, a complex multilevel analysis platform has been designed, fabricated and tested (All rights reserved-IT Patent number TO2009A000915). This LOC successfully manages to interface microfluidic channels with standard DNA microarray glass slides, in order to implement a complete biological protocol. Typical Micro Electro Mechanical Systems (MEMS) materials and process technologies were employed. A silicon/glass microfluidic chip and a Polydimethylsiloxane (PDMS) reaction chamber were fabricated and interfaced with a standard microarray glass slide. In order to have a high disposable system all micro-elements were passive and an external apparatus provided fluidic driving and thermal control. The major microfluidic and handling problems were investigated and innovative solutions were found. Finally, an entirely automated DNA hybridization protocol was successfully tested with a significant reduction in analysis time and reagent consumption with respect to a conventional protocol.


Assuntos
DNA/análise , DNA/genética , Técnicas Analíticas Microfluídicas/instrumentação , Análise de Sequência com Séries de Oligonucleotídeos/instrumentação , Sequência de Bases , Colorimetria , Dimetilpolisiloxanos/química , Vidro/química , Humanos , Microtecnologia , Hibridização de Ácido Nucleico , Reprodutibilidade dos Testes , Silício/química
17.
Micromachines (Basel) ; 12(3)2021 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-33801509

RESUMO

Initially considered little more than a scientific curiosity, the family of 2D nanomaterials has become increasingly popular over the last decade [...].

18.
J Mater Chem B ; 10(1): 87-95, 2021 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-34870646

RESUMO

In this paper, for the first time to the best of our knowledge, organic electrochemical transistors are employed to investigate the electrical response of human blood, plasma and alternative buffer solutions that inhibit red blood cell (RBC) aggregation. Our focus is on selecting a suitable electrolytic platform and the related operating conditions, where the RBC effect on the OECT response can be observed separately from the strong ionic environment of plasma in whole blood. The transient response of whole blood to pulse experiments is characterized by two time constants, which can be related to blood viscosity and to the capacitive coupling between the ionic and electronic components of the overall system. The role of capacitive effects, likely due to enhanced double-layer formation by negatively charged RBCs, is also confirmed by the increase of transconductance which was found in RBC suspensions as compared to the suspending buffer. Overall, the complex behavior found in these experiments provides new insights for the development of innovative blood-based sensing devices for biomedical applications.


Assuntos
Materiais Biocompatíveis/farmacologia , Técnicas Biossensoriais , Técnicas Eletroquímicas , Eritrócitos/efeitos dos fármacos , Materiais Biocompatíveis/química , Agregação Celular/efeitos dos fármacos , Humanos , Teste de Materiais , Tamanho da Partícula , Transistores Eletrônicos
19.
Nanomaterials (Basel) ; 11(10)2021 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-34685065

RESUMO

This work illustrates focalization performances of a silicon-based bulk acoustic wave device applied for the separation of specimens owing to micrometric dimensions. Samples are separated in the microfluidic channel by the presence of an acoustic field, which focalizes particles or cells according to their mechanical properties compared to the surrounded medium ones. Design and fabrication processes are reported, followed by focalization performance tests conducted either with synthetic particles or cells. High focalization performances occurred at different microparticle concentrations. In addition, preliminary tests carried out with HL-60 cells highlighted an optimal separation performance at a high flow rate and when cells are mixed with micro and nanoparticles without affecting device focalization capabilities. These encouraging results showed how this bulk acoustic wave device could be exploited to develop a diagnostic tool for early diagnosis or some specific target therapies by separating different kinds of cells or biomarkers possessing different mechanical properties such as shapes, sizes and densities.

20.
Nanomaterials (Basel) ; 11(1)2021 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-33406608

RESUMO

We report on the preparation and stereolithographic 3D printing of a resin based on the composite between a poly(ethylene glycol) diacrylate (PEGDA) host matrix and a poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) filler, and the related cumulative volatile organic compounds' (VOCs) adsorbent properties. The control of all the steps for resin preparation and printing through morphological (SEM), structural (Raman spectroscopy) and functional (I/V measurements) characterizations allowed us to obtain conductive 3D objects of complex and reproducible geometry. These systems can interact with chemical vapors in the long term by providing a consistent and detectable variation of their structural and conductive characteristics. The materials and the manufacture protocol here reported thus propose an innovative and versatile technology for VOCs monitoring systems based on cumulative adsorption effects.