Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 107
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Cell ; 156(5): 1017-31, 2014 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-24581499

RESUMO

The spindle assembly checkpoint (SAC) delays anaphase until all chromosomes are bioriented on the mitotic spindle. Under current models, unattached kinetochores transduce the SAC by catalyzing the intramitotic production of a diffusible inhibitor of APC/C(Cdc20) (the anaphase-promoting complex/cyclosome and its coactivator Cdc20, a large ubiquitin ligase). Here we show that nuclear pore complexes (NPCs) in interphase cells also function as scaffolds for anaphase-inhibitory signaling. This role is mediated by Mad1-Mad2 complexes tethered to the nuclear basket, which activate soluble Mad2 as a binding partner and inhibitor of Cdc20 in the cytoplasm. Displacing Mad1-Mad2 from nuclear pores accelerated anaphase onset, prevented effective correction of merotelic errors, and increased the threshold of kinetochore-dependent signaling needed to halt mitosis in response to spindle poisons. A heterologous Mad1-NPC tether restored Cdc20 inhibitor production and normal M phase control. We conclude that nuclear pores and kinetochores both emit "wait anaphase" signals that preserve genome integrity.


Assuntos
Anáfase , Proteínas de Ciclo Celular/metabolismo , Pontos de Checagem da Fase M do Ciclo Celular , Proteínas Mad2/metabolismo , Poro Nuclear/metabolismo , Proteínas Nucleares/metabolismo , Transporte Ativo do Núcleo Celular , Proteínas de Ciclo Celular/genética , Dimerização , Células HCT116 , Células HeLa , Humanos , Interfase , Cinetocoros/metabolismo , Mitose , Proteínas Nucleares/genética
2.
J Shoulder Elbow Surg ; 33(4): 924-931, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37648015

RESUMO

BACKGROUND: The popularity of team handball is increasing, with >10 million children playing this overhead throwing and collision sport with highest demands on the shoulder joint. Because of the risk of recurrent instability, the Latarjet-Patte (LP) procedure has been recommended to treat young competitive players. This is the first LP outcome study in professional handball players. METHODS: We retrospectively included 20 shoulders (18 players [17 male patients]; mean age, 22.9 years [range, 17-35 years]; minimum follow-up period, 2 years; mean follow-up period, 6.6 years) operated on by 3 expert surgeons (2011-2020) with the Walch LP technique. We documented preoperative hyperlaxity (25%, n = 5), affected throwing arm (55%, n = 11), position (backcourt, winger, and goalkeeper, 22% each; full back and pivot, 17% each), >2 dislocations prior (20%, n = 4), >10 dislocations prior (5%, n = 1), previous failed Bankart or humeral avulsion of glenohumeral ligament (HAGL) repair (10%, n = 2), and large Hill-Sachs lesions (HSLs) (20%, n = 4). Clinical and radiographic outcomes, visual analog scale score, Subjective Shoulder Value, Walch-Duplay score, Rowe score, and return-to-sport (RTS) rate were recorded. RESULTS: The RTS rate was 85% (17 of 20 shoulders); rate of RTS at the same level, 80% (16 of 20); and rate of RTS with no throwing pain, 73% (8 of 11). The time to training with a ball was 3.2 months, and the time to competition was 4.9 months. The mean Rowe score, Walch-Duplay score, and Subjective Shoulder Value were 90 points, 88 points, and 89%, respectively. Shoulder symptoms led players to give up handball in 2 cases (10%), whereas 1 player (5%) stopped playing handball for other reasons. We recorded 1 recurrent dislocation (5%) (non-throwing arm, winger, no recurrence after rehabilitation). Persistent apprehension occurred in 1 goalkeeper (5%). Residual pain was seen in 4 shoulders (20%); this was relieved by screw removal in 1. Resistant pain (throwing shoulder) was seen in 2 backcourt players (10%, 1 of whom had a large HSL) and 1 goalkeeper (5%; large HSL with >10 dislocations prior), all 3 of whom were aged > 30 years. Bone block positioning was correct (no lateral overhang) in all shoulders. At final follow-up, 1 shoulder (5%) showed mild arthritic changes (>10 dislocations, large HSL). CONCLUSION: The open LP procedure is consistent in providing shoulder stability combined with return-to-throwing performance in professional handball players with a short time to RTS and high same-level RTS rate without increasing the risk of arthritic changes. Throwing shoulders of backcourt players, large HSLs, or age > 30 years may have an increased risk of persistent symptoms.


Assuntos
Luxações Articulares , Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Criança , Humanos , Masculino , Adulto Jovem , Adulto , Articulação do Ombro/cirurgia , Luxação do Ombro/cirurgia , Luxação do Ombro/etiologia , Instabilidade Articular/cirurgia , Instabilidade Articular/etiologia , Seguimentos , Estudos Retrospectivos , Luxações Articulares/etiologia , Dor/etiologia , Artroscopia/métodos
3.
J Shoulder Elbow Surg ; 33(7): 1570-1576, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38218405

RESUMO

PURPOSE: This study aimed to evaluate whether functional internal rotation (fIR) following reverse shoulder arthroplasty (RSA) differs based on diagnosis of either: primary osteoarthritis (OA) with intact rotator cuff, massive irreparable rotator cuff tear (MICT) or cuff tear arthropathy (CTA). METHODS: A retrospective review was carried out on RSAs performed by a single surgeon with the same implant over a 5-year period. Minimum 2-year follow-up was available in 235 patients; 139 (59.1%) were female, and the mean patient age was 72 ± 8 years. Additional clinical evaluation included the Subjective Shoulder Value and Constant score. Postoperative internal rotation was categorized as type I: hand to the buttock or hip; type II: hand to the lower lumbar region; or type III: smooth motion to at least the upper lumbar region. Type I was considered "nonfunctional" internal rotation, and type II and III were fIR. RESULTS: Preoperatively, internal rotation was classified as type I in 60 patients (25.5%), type II in 114 (48.5%), and type III in 62 (26%). Postoperatively, internal rotation was classified as type I in 70 patients (30%), type II in 86 (36%), and type III in 79 (34%). Compared with preoperative status, fIR improved significantly in OA patients (P < .001), with 49 (52.6%) classified as type II or III postoperatively. In CTA patients, there was no significant change (P = .352). In patients with MICTs, there was a significant loss in fIR postoperatively (P = .003), with 25 patients (30.8%) deteriorating to type I after having either type II or III preoperatively, and only 5 patients (6.1%) improving to either type II or III. CONCLUSIONS: Patients who undergo RSA for primary OA have a better chance of postoperative fIR improvement. A decrease in fIR is common after RSA for MICTs.


Assuntos
Artroplastia do Ombro , Amplitude de Movimento Articular , Lesões do Manguito Rotador , Humanos , Feminino , Masculino , Idoso , Estudos Retrospectivos , Artroplastia do Ombro/métodos , Lesões do Manguito Rotador/cirurgia , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Osteoartrite/cirurgia , Artropatia de Ruptura do Manguito Rotador/cirurgia , Manguito Rotador/cirurgia , Rotação
4.
Artigo em Inglês | MEDLINE | ID: mdl-38857649

RESUMO

BACKGROUND: While forward flexion consistently improves after reverse shoulder arthroplasty (RSA), restoration of internal rotation behind the back (IR1) is much less predictable. This study aims to evaluate the role of the subscapularis tendon in restoration of IR and identify other factors that may influence IR such as anterior scapular tilt and postoperative passive internal rotation at 90° of abduction (IR2). The hypothesis was that IR1 is positively associated with both subscapularis healing, postoperative passive IR2, and anterior scapular tilt. METHODS: A retrospective review was performed on a consecutive series of Grammont style BIO (bony increased offset) RSAs performed by a single surgeon between January 2014 and December 2015. Inclusion criteria were: (1) primary RSA for rotator cuff arthropathy, massive irreparable rotator cuff tear, or primary osteoarthritis with B2 glenoid morphology, (2) minimum of two years clinical follow-up, and (3) complete intraoperative repair of a repairable subscapularis tendon. The primary outcomes were postoperative return of IR1 compared to postoperative IR2, healing rate of subscapularis tendon, and scapular tilt. RESULTS: The cohort included 77 patients, aged 72.6±7.0 years at index surgery and comprising 32 men (42%) and 45 women (58%). At a mean follow-up of 3.3±1.0 years, ultrasound evaluation revealed a successful repair of the subscapularis in 41 patients (53%). Healed subscapularis repair was significantly associated with greater IR1 (85% vs. 53%, p=0.031). A multivariate logistic regression revealed functional postoperative IR1 was independently associated with subscapularis healing (OR, 4.3; 95%CI [1.1-20.2]; p=0.046) as well as greater anterior tilt (OR, 1.2; 95%CI [1.1-1.5]; p=0.008) and postoperative IR2 (OR, 1.09; 95%CI [1.05-1.14]; p<0.001) but lower postoperative passive abduction (OR, 0.96; 95%CI [0.92-1.00], p=0.045). The area under receiver operating characteristic curve obtained with the Youden index was 0.88 with a sensitivity of 81.8% and specificity of 90.6%. CONCLUSIONS: This study revealed that in a Grammont-type RSA, postoperative IR1 recovery is first associated with subscapularis tendon healing, followed by IR2 and finally the ability to tilt the scapula anteriorly. Better understanding of these factors preoperatively may provide greater insight on expected return of functional internal after RSA.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38821171

RESUMO

BACKGROUND: There is a common concern that range of motion (ROM) is negatively affected by the Latarjet procedure. We hypothesize that the Latarjet procedure results in full recuperation of ROM postoperatively and significantly improved patient reported outcome measures. METHODS: Patient data were prospectively collected from a randomized controlled trial to analyze outcomes after open Latarjet procedure. Inclusion criteria involved a minimum follow-up of six months and unilateral shoulder instability. Study outcome was assessed by postoperative ROM at six months postoperatively and compared to the preoperative ROM of the ipsilateral shoulder as well as the ROM of the unaffected contralateral shoulder. All ROM measurements were performed utilizing a motion capture system to ensure consistent and reliable measurements. RESULTS: The study included a total of 84 patients. ROM was measured in external rotation with the shoulder adducted (ER1), external rotation with the shoulder abducted 90 degrees (ER2), internal rotation with the arm abducted 90 degrees (IR2), and active forward elevation (AE). The average difference in ROM between the operated arm vs. the contralateral healthy arm at six months postoperatively was 3.4 degrees in ER1 (p=0.19), 4.2 degrees in ER2 (p=0.086), 2.2 degrees in IR2 (p=0.36), and 2.4 degrees in AE (p=0.045). Sub-analysis of patients with and without sling use revealed no significant difference in ROM between the operated shoulder and contralateral shoulder at six months in either group, with the exception of ER2 in the sling group. In this latter group, ROM was 71 degrees in the operated arm and 79 degrees in the contralateral arm (p=0.0094). Average preoperative pain score was 25.7 (21.4-30.1, 95%CI) vs. 13.0 postoperatively at six months (9.50-16.5, 95%CI) (p <0.00001). Average preoperative SANE instability was 42.9 (38.4-47.3, 95%CI) vs. 86.2 postoperatively at six months (83.6-88.7, 95%CI) (p <0.00001). Average preoperative Rowe score was 38.5 (34.3-42.7, 95%CI) vs. 84.3 at six postoperative months (81.1-87.4, 95%CI) (p<0.00001). CONCLUSIONS: Latarjet procedure performed for anterior instability utilizing a capsular repair result in complete ROM recovery in ER1, ER2, and IR2 at six months postoperatively, with only a slight discrepancy in active elevation. Sling use after the Latarjet procedure results in no benefit over postoperative recovery without the use of a sling. Sling use negatively affects the ROM in ER2, taking as reference the contralateral arm of the same patient, when compared to patients that did not use a sling postoperatively.

6.
J Shoulder Elbow Surg ; 33(5): 1177-1184, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37890765

RESUMO

BACKGROUND: Mixed reality may offer an alternative for computer-assisted navigation in shoulder arthroplasty. The purpose of this study was to determine the accuracy and precision of mixed-reality guidance for the placement of the glenoid axis pin in cadaver specimens. This step is essential for accurate glenoid placement in total shoulder arthroplasty. METHODS: Fourteen cadaveric shoulders underwent simulated shoulder replacement surgery by 7 experienced shoulder surgeons. The surgeons exposed the cadavers through a deltopectoral approach and then used mixed-reality surgical navigation to insert a guide pin in a preplanned position and trajectory in the glenoid. The mixed-reality system used the Microsoft Hololens 2 headset, navigation software, dedicated instruments with fiducial marker cubes, and a securing pin. Computed tomography scans obtained before and after the procedure were used to plan the surgeries and determine the difference between the planned and executed values for the entry point, version, and inclination. One specimen had to be discarded from the analysis because the guide pin was removed accidentally before obtaining the postprocedure computed tomography scan. RESULTS: Regarding the navigated entry point on the glenoid, the mean difference between planned and executed values was 1.7 ± 0.8 mm; this difference was 1.2 ± 0.6 mm in the superior-inferior direction and 0.9 ± 0.8 mm in the anterior-posterior direction. The maximum deviation from the entry point for all 13 specimens analyzed was 3.1 mm. Regarding version, the mean difference between planned and executed version values was 1.6° ± 1.2°, with a maximum deviation in version for all 13 specimens of 4.1°. Regarding inclination, the mean angular difference was 1.7° ± 1.5°, with a maximum deviation in inclination of 5°. CONCLUSIONS: The mixed-reality navigation system used in this study allowed surgeons to insert the glenoid guide pin on average within 2 mm from the planned entry point and within 2° of version and inclination. The navigated values did not exceed 3 mm or 5°, respectively, for any of the specimens analyzed. This approach may help surgeons more accurately place the definitive glenoid component.


Assuntos
Artroplastia do Ombro , Artroplastia de Substituição , Realidade Aumentada , Cavidade Glenoide , Articulação do Ombro , Cirurgia Assistida por Computador , Humanos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Artroplastia de Substituição/métodos , Cirurgia Assistida por Computador/métodos , Cadáver , Imageamento Tridimensional/métodos , Cavidade Glenoide/diagnóstico por imagem , Cavidade Glenoide/cirurgia
7.
J Shoulder Elbow Surg ; 32(9): e464-e474, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36905950

RESUMO

BACKGROUND: Recently, a stemless reverse shoulder arthroplasty (RSA) design was developed to preserve bone stock. Clinical and radiologic studies of this design in larger cohorts with >100 patients are not frequent. The purpose of this study was to present the clinical and radiologic results of a newly developed stemless RSA implant. The hypothesis was that this design would provide similar clinical and radiologic results to other stemless implants, as well as stemmed implants. METHODS: Between September 2015 and December 2019, all patients who underwent primary RSA with a stemless Easytech prosthesis were considered eligible for inclusion in this prospective multicenter study. The minimum follow-up period was 2 years. Clinical outcomes consisted of the Constant score, adjusted Constant score, QuickDASH (short version of Disabilities of the Arm, Shoulder and Hand questionnaire) score, Subjective Shoulder Value, and American Shoulder and Elbow Surgeons shoulder score. Radiographic parameters included radiolucency, loosening, scapular notching, and specific geometric parameters. RESULTS: Stemless RSA was performed in 115 patients (61 women and 54 men) at 6 different clinical centers. The average age at the time of surgery was 68.7 years. The average Constant score was 32.5 preoperatively and showed significant improvement to 61.8 at latest follow-up (P < .001). The Subjective Shoulder Value also demonstrated significant improvement postoperatively (from 27.0 to 77.5, P < .001). Scapular notching was observed in 28 patients (24.3%); humeral loosening, 5 (4.3%); and glenoid loosening, 4 (3.5%). The total complication rate was 17.4%. Eight patients (4 women and 4 men) underwent implant revision. CONCLUSION: The clinical outcomes of the examined stemless RSA seem to be comparable to those of other humeral designs; however, the complication and revision rates are higher than those of historical controls. Surgeons should proceed with caution when using this implant until longer-term follow-up data are available.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Masculino , Humanos , Feminino , Idoso , Artroplastia do Ombro/métodos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Seguimentos , Estudos Prospectivos , Resultado do Tratamento , Desenho de Prótese , Amplitude de Movimento Articular , Estudos Retrospectivos
8.
Arthroscopy ; 38(6): 1766-1771, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34883198

RESUMO

PURPOSE: To evaluate the short-term outcomes of the arthroscopic dynamic anterior stabilization (DAS), which is a transfer of the intra-articular portion of the long head biceps through the subscapularis split and fixation on the anterior glenoid, combined with a Bankart repair. METHODS: A retrospective evaluation was performed of DAS and a minimum of 2-year follow-up. Inclusion criteria were the presence of anteroinferior instability, a positive apprehension test at 90° of abduction and external rotation, and subcritical glenoid bone loss (less than 20%). Exclusion criteria were severe (≥20%) glenoid bone loss, presence of biceps lesions or rupture (spontaneous or biceps tenotomy), pre-existing glenohumeral osteoarthritis, multidirectional or voluntary instability, previous arthroscopic stabilization procedure, and epilepsy. Outcomes included the Rowe score, range of motion (ROM), and recurrence. RESULTS: Twenty-three patients were treated with DAS and arthroscopic Bankart repair during the study period. One person was lost to follow-up, leaving 22 patients available at last follow-up. Those 22 patients had an average age of 31.9 ± 12.3 years (range, 18-68) and were evaluated at an average follow-up of 3.2 ± 0.7 years (range, 1.2-4.2). The Rowe score increased from 36.1 ± 16.2 (range, 10-70) preoperatively to 89.8 ± 20.1 (range, 30-100) postoperatively (P < .001) with almost all patients (90.9%) improving their score beyond the minimal clinically important difference of 9.7 points. Postoperatively, ROM was maintained. Three patients (13.6%) analyzed at final follow-up demonstrated recurrence, one was successfully treated conservatively, but two revised with a Latarjet. No postoperative Popeye deformity, biceps cramping, or other complication were reported. CONCLUSIONS: The DAS procedure may be an option for augmentation of a Bankart repair in patients with anterior shoulder instability and subcritical bone loss. ROM is maintained without evidence of postoperative Popeye deformity or biceps cramping. LEVEL OF EVIDENCE: Level IV, retrospective study.


Assuntos
Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Adulto , Artroscopia/métodos , Humanos , Instabilidade Articular/etiologia , Instabilidade Articular/cirurgia , Amplitude de Movimento Articular , Recidiva , Estudos Retrospectivos , Escápula/cirurgia , Luxação do Ombro/complicações , Luxação do Ombro/cirurgia , Articulação do Ombro/cirurgia , Adulto Jovem
9.
J Shoulder Elbow Surg ; 31(1): 63-71, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34216783

RESUMO

HYPOTHESIS AND BACKGROUND: The role of the subscapularis in reverse shoulder arthroplasty (RSA) remains controversial. Studies have shown that subscapularis repair has no significant influence on the functional outcomes of patients. However, few studies have assessed the postoperative integrity of the subscapularis tendon after RSA. The aims of this study were to investigate the postoperative healing of the subscapularis after RSA via ultrasound and to evaluate the relationship between tendon integrity and functional outcomes. We hypothesized that subjects with a healed subscapularis after RSA would have higher Constant scores and better internal rotation (IR) than those without a healed subscapularis. METHODS: This was a retrospective review of all patients who underwent primary RSA with subscapularis tenotomy repair performed by a single surgeon with a minimum 2-year follow-up period. The inclusion criteria were (1) primary RSA and (2) complete intraoperative repair of the subscapularis tenotomy if the tendon was amenable to repair. The total Constant score and active and passive range of motion were measured preoperatively and at every postoperative visit. IR was further subcategorized into 3 functional types (type I, buttock or sacrum; type II, lumbar region; and type III, T12 or higher). The integrity of the subscapularis on ultrasound at 2 years was reported using the Sugaya classification. The correlation between subscapularis integrity and functional outcomes including functional IR was evaluated. RESULTS: A total of 86 patients (mean age, 73 ± 7.4 years; age range, 50-89 years) were evaluated. The mean postoperative Constant score for all patients significantly improved from 38 points to 72 points (P < .001) at last follow-up (mean, 3.3 years). There was significant improvement in all Constant score functional subscales and in terms of range of motion. The rate of sonographic healing of the subscapularis was 52.6%. There was no difference in Constant scores between "intact" and "failed" tendon repairs; however, intact tendons demonstrated significantly better IR with no difference in external rotation (P < .01). CONCLUSION: The healing rate of the subscapularis following RSA was only 52.6%. IR function in patients with an intact subscapularis at 2 years after RSA was significantly better than in patients with failed or absent tendon repairs. Primary repair of reparable subscapularis tendons during RSA should be strongly considered.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Estudos Retrospectivos , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Tendões/cirurgia , Resultado do Tratamento
10.
J Orthop Sci ; 2022 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-36437153

RESUMO

BACKGROUND: Although Grammont-style reverse total shoulder arthroplasty (RSA) showed excellent clinical results in Europe, its utility for Asian populations remains unclear. This study aimed to compare the French and Japanese populations in terms of range of motion (ROM), functional outcomes, and scapular notching rates in patients who underwent standard Grammont-style RSA. We hypothesized that RSA for the Japanese population may not provide as good ROM and functional results at the final follow-up as that for the French population. METHODS: A total of 25 Japanese patients undergoing RSA were propensity score matched to 25 French patients undergoing RSA. The patients were matched for four different covariates using a propensity score analysis. The minimum follow-up period was 2 years. We investigated differences between the populations with respect to body size and shoulder joint ROM and Constant score (CS) measured preoperatively and at the final follow-up. Scapular notching was examined using radiographs at the final follow-up. RESULTS: The average height and weight of the French and Japanese patients were 164 cm and 70 kg and 152 cm and 56 kg, respectively. Anterior elevation (AE), external rotation (ER) at the side, internal rotation (IR), and CS total changed from 101° to 145°, 17° to 15°, 4.5 points to 5.5 points, and 36 points to 72 points, respectively, in the French population and from 63° to 119°, 8.5° to 13°, 4.6 points to 4 points, and 28 points to 58 points, respectively, in the Japanese population. AE improved in both the groups; ER and IR remained unchanged before and after surgery. The frequency of scapular notching (>grade 1) was higher in the Japanese population (56%) than in the French population (20%) (p = 0.019). CONCLUSIONS: Grammont-style RSA improved AE and CS in both the populations, but AE and CS were significantly higher in the French population than in the Japanese population at the final follow-up. Scapular notching frequently occurs in the Japanese population.

11.
Knee Surg Sports Traumatol Arthrosc ; 29(7): 2118-2133, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32725446

RESUMO

PURPOSE: Clinical diagnosis of posterosuperior rotator cuff tears remains uncertain due to a lack of evidence-based consensus. This review aimed to compare the diagnostic accuracy of commonly used clinical tests for posterosuperior rotator cuff tears. METHODS: The authors conducted an electronic literature search using Medline, Embase and the Cochrane library/Central, to identify original clinical studies reporting diagnostic accuracy of clinical tests to diagnose the presence of posterosuperior rotator cuff tears involving the infraspinatus, supraspinatus and/or teres minor. RESULTS: The electronic literature search returned 1981 records, of which 14 articles were eligible. Among 17 tests included in the systematic review, 6 tests were eligible for meta-analysis: drop arm sign, Jobe test, external rotation lag sign, Hawkins-Kennedy test, Neer test and painful arc abduction test. According to QUADAS-2 criteria, risk of bias was low in 1 study, moderate in 2 and high in 4. The highest pooled sensitivity was 0.77 (CI 0.67-0.85), for the Jobe test, while the lowest pooled sensitivity was 0.38 (CI 0.01-0.98), for the drop arm sign. CONCLUSIONS: The Jobe test had the best pooled sensitivity, while the drop arm sign had the best pooled specificity. As no single clinical test is sufficiently reliable to diagnose posterosuperior rotator cuff tears, clinicians should consider various combinations of patient characteristics and clinical tests, as well as imaging modalities, to confirm diagnosis and select the appropriate treatment option. More reliable clinical diagnosis of posterosuperior rotator cuff tears could reduce the reliance on magnetic resonance imaging or arthrography and their associated costs and waiting times. LEVEL OF EVIDENCE: Level II.


Assuntos
Lesões do Manguito Rotador/diagnóstico , Artrografia , Traumatismos em Atletas/diagnóstico , Traumatismos em Atletas/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Exame Físico , Rotação , Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/diagnóstico por imagem , Sensibilidade e Especificidade
12.
J Shoulder Elbow Surg ; 30(1): 97-103, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32778379

RESUMO

BACKGROUND: Sugaya classification is a widely accepted classification system that is used to analyze postoperative rotator cuff tendon integrity. However, there are inconsistencies in the literature as to whether type 3 Sugaya should be considered as a retear or healed tendon. PURPOSE: We aimed to show that type 3 Sugaya is not a retear by comparing the long-term supraspinatus and infraspinatus muscle degeneration and the functional outcomes of type 3 with those of type 4 and 5 Sugaya. We hypothesized that the clinical course of type 3 Sugaya would be different from type 4 or 5 Sugaya. METHOD: The study was a retrospective multicenter review of all the rotator cuff repair done in 2003-2004. We included all the patients who had undergone supraspinatus repair with 10-year follow-up (magnetic resonance imaging done with full functional assessment). Data collection included pre- and postoperative supraspinatus and infraspinatus fatty infiltration, supraspinatus muscle atrophy, and Constant score with a separate analysis of its Strength subsection. Supraspinatus tendon integrity at 10-year follow-up was determined according to Sugaya classification. The patients were divided into 2 groups: type 3 Sugaya and type 4 and 5 Sugaya. Statistical comparison was done between the groups. RESULTS: There was no significant difference in the preoperative fatty infiltration of the supraspinatus and infraspinatus, supraspinatus muscle atrophy, and Constant score between the 2 groups. However, type 3 Sugaya patients had significantly better scores in the preoperative Strength subsection. Postoperatively, type 3 Sugaya patients showed significantly lesser fatty infiltration of the supraspinatus and infraspinatus, lesser supraspinatus muscle atrophy, and higher Constant score compared with type 4 and 5 Sugaya (P < .001). CONCLUSION: Patients with type 3 Sugaya supraspinatus tendon exhibited lesser muscle degeneration in the supraspinatus and infraspinatus and performed better in functional assessment compared with type 4 and 5 Sugaya patients. We inferred that type 3 Sugaya should not be considered as a retear.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador , Artroscopia , Humanos , Imageamento por Ressonância Magnética , Período Pós-Operatório , Estudos Retrospectivos , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Resultado do Tratamento
13.
J Shoulder Elbow Surg ; 30(5): 1167-1173, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32871266

RESUMO

BACKGROUND: Several functional outcome scores have been proposed for the evaluation of shoulder instability. Most are multiple-item questionnaires, which can be time-consuming and difficult for patients to understand, as well as leading to lack of compliance. The Single Assessment Numeric Evaluation (SANE) score is a single question that has recently gained widespread acceptance based on its simplicity and correlation with more complex scoring systems. The purpose of this study was to assess the correlation of a new modified version of the SANE score, the SANE-instability score, with the Rowe score after treatment for shoulder instability. MATERIALS AND METHODS: We prospectively evaluated a consecutive series of 253 patients (268 shoulders) treated surgically or nonoperatively for shoulder instability between November 2017 and November 2019, for whom the Rowe and SANE-instability scores were collected before treatment and/or after treatment. The SANE-instability score was assessed with the following question: "What is the overall percent value of your shoulder if a completely stable shoulder represents 100%?" Correlations were tested using the Pearson coefficient (r) and interpreted as very high (r = 0.90-1.00), high (r = 0.70-0.89), moderate (r = 0.50-0.69), low (r = 0.30-0.49), or negligible (r = 0.00-0.29). Subgroup analyses were also performed to observe correlation variations according to follow-up length (before treatment and at 6, 12, 26, 52, and 104 weeks after treatment), patient age (<20, 20-29, 30-39, or ≥40 years), and type of treatment (nonoperative or surgical). RESULTS: The overall correlation between the SANE-instability and Rowe scores was high (r = 0.85, P < .001). Subgroup analyses revealed that the correlation between the 2 scores was high before treatment (r = 0.74); moderate at 6 and 12 weeks after treatment (r = 0.66 and r = 0.57, respectively); and then high at 26, 52, and 104 weeks after treatment (r = 0.75, r = 0.75, and r = 0.78, respectively) (P < .001). The correlation was high across all types of treatment (r = 0.76-0.85), high for patients aged ≥ 20 years (r = 0.80-0.86), and very high for patients aged < 20 years (r = 0.93) (P < .001). CONCLUSION: This study demonstrated a significant correlation between the SANE-instability and Rowe scores before and after treatment, as well as across all patient age groups and treatments. Owing to its high simplicity, the SANE-instability score could be used as an alternative to the Rowe score for patient follow-up at various time points.


Assuntos
Instabilidade Articular , Articulação do Ombro , Adulto , Humanos , Instabilidade Articular/diagnóstico , Articulação do Ombro/cirurgia , Inquéritos e Questionários
14.
J Shoulder Elbow Surg ; 30(10): 2361-2369, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33677116

RESUMO

BACKGROUND: This study aimed to describe the clinical outcomes and complications of 10 cases of pyrocarbon interposition shoulder arthroplasty (PISA). METHODS: The clinical and radiographic records of 10 patients who underwent PISA using the InSpyre shoulder prosthesis (Tornier-Wright) between July 2012 and March 2017 were reviewed. The mean age at surgery was 55 years. Surgical indications included patients aged <60 years with Walch type B glenoid glenohumeral osteoarthritis (n = 7), avascular necrosis (AVN) of the humeral head (n = 1), or secondary severe glenohumeral osteoarthritis with axillary nerve dysfunction (n = 2). Outcomes of interest were postoperative complications and need for revision surgery, preoperative and postoperative patient-reported outcomes (Constant score [CS] and Subjective Shoulder Value [SSV]), and range of motion. The radiographic characteristics of the implants were evaluated. RESULTS: Among the 10 patients, 5 underwent revision to reverse shoulder arthroplasty during the study period owing to poor clinical outcomes based on the CS and SSV. All 5 revised patients had Walch type B glenoid morphology at the time of the index procedure. The mean time to revision surgery in this subset of patients was 60 months. The remaining 5 patients who did not undergo any revision procedure had significant improvement in mean CS and SSV from 30-65 points and 32%-87%, respectively, but at a shorter duration of follow-up of 35 months. CONCLUSION: High clinical failure rate and poor results at mean 5-year follow-up were found in younger PISA patients with baseline Walch B glenohumeral osteoarthritis. We would caution against use of PISA in this challenging patient population. PISA yielded more favorable short-term outcomes in patients with humeral-sided deformity or severe secondary glenohumeral osteoarthritis with axillary nerve dysfunction; however, longevity of the implant in this population remains unclear.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Carbono , Seguimentos , Humanos , Cabeça do Úmero/cirurgia , Amplitude de Movimento Articular , Estudos Retrospectivos , Ombro , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Resultado do Tratamento
15.
J Shoulder Elbow Surg ; 30(3): 635-640, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32650071

RESUMO

BACKGROUND: Some comparative studies have reported improved outcomes for early compared with delayed reconstruction for high-grade acromioclavicular (AC) joint dislocations. However, most are based on older techniques and did not specifically involve reconstruction of both the coracoclavicular (CC) and AC joint ligaments. The purpose of this study was to compare functional outcomes of early vs. delayed surgical intervention of AC joint dislocations managed with combined CC and AC ligament reconstruction. METHODS: A retrospective comparative study was performed of 53 patients who underwent early (<2 weeks after injury) or delayed (≥2 weeks after injury) open stabilization for AC joint dislocation. All patients were managed with the same surgical technique of combined CC reconstruction and stabilization of the AC joint, except for the addition of a gracilis allograft for biologic CC reconstruction in delayed intervention. Outcome was determined at a minimum follow-up of 12 months, using the Acromioclavicular Joint Instability (ACJI) score, Taft score, Subjective Shoulder Value (SSV), visual analog scale (VAS) for pain, and overall satisfaction (0-10). Multivariable regression analyses were performed to test associations of ACJI and Taft scores with 5 independent variables (early vs. delayed surgery, age, sex, manual worker, and Rockwood type). RESULTS: The cohort comprised 47 men (89%) and 6 women (11%) aged 40.1 ± 11.2 years (range, 22-63 years). The early group (n = 31) underwent surgery 1.1 ± 0.5 weeks after injury, whereas the delayed group (n = 22) underwent surgery 84.3 ± 99.1 weeks after injury. There were no significant differences in ACJI scores (87 ± 14 vs. 89 ± 14, P = .267), Taft scores (10.1 ± 1.3 vs. 10.7 ± 1.3, P = .084), pain on VAS (0.3 ± 0.7 vs. 0.6 ± 1.1, P = .541), SSV (95 ± 7 vs. 93 ± 9, P = .427), or overall satisfaction (9.6 ± 0.9 vs. 9.4 ± 1.1, P = .491). Multivariable analyses revealed no associations between any of the independent variables and ACJI or Taft score. CONCLUSIONS: Early and delayed surgical interventions of high-grade AC joint dislocation provide equivalent clinical scores when combined CC and AC joint fixation is used for stabilization. Rapid surgical intervention for high-grade AC joint dislocation may not be necessary, as most patients can still benefit from surgery at a later stage.


Assuntos
Articulação Acromioclavicular , Luxações Articulares , Articulação Acromioclavicular/cirurgia , Adulto , Feminino , Humanos , Luxações Articulares/cirurgia , Ligamentos Articulares/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
16.
J Shoulder Elbow Surg ; 30(7S): S100-S108, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33600899

RESUMO

BACKGROUND: The purpose of this study was to evaluate how patients treated with reverse shoulder arthroplasty (RSA) achieve internal rotation (IR) using video assessment and to compare this to patient-reported outcome measures (PROMs). METHODS: We reviewed 215 preoperative and 657 postoperative videos (3-78 months) for 215 patients who underwent primary RSA, performing IR using the modified vertebral level method. Their functional motion pattern was then grouped into 3 types: type I, could not reach behind their back; type II, able to reach to at least waist level, with assistance; and type III, able to reach to a minimum of waist level in an uninterrupted fashion. Patients completed functional questions (put on a coat, wash back, tuck in a shirt, and manage toileting) and a diagram of perceived IR. Patients' functional motion types were compared to PROM answers. Pre- and postoperative scores were also compared to assess the effect of surgery on patients' perception of IR function. RESULTS: Patients undergoing RSA will achieve IR in 3 distinct motion patterns. Analysis of self-reported IR indicated statistically significant difference between the 3 functional types of IR (P < .001). Patient-perceived IR was not significantly different between the 3 studied IR functional types (P = .076) in the analysis of preoperative measures but was significantly different in the postoperative setting (P < .001). CONCLUSION: Patients attempt IR in 3 distinct functional motion patterns. The improvement of IR after RSA is measured better by patient questionnaires than by physical examination.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Medidas de Resultados Relatados pelo Paciente , Percepção , Amplitude de Movimento Articular , Estudos Retrospectivos , Rotação , Articulação do Ombro/cirurgia , Resultado do Tratamento
17.
J Shoulder Elbow Surg ; 29(3): 521-526, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31594728

RESUMO

BACKGROUND: Short- and mid-term outcomes after massive cuff tear repair are well reported, but there is no documentation of the clinical and structural outcomes at 20 years of follow-up. The hypothesis of the present study was that at 20 years, deterioration of the shoulder would have occurred and led to a substantial number of reoperations. METHODS: The authors retrospectively recalled all 127 patients operated for massive rotator cuff tears in 1994 at 6 different centers. At the 20-year follow-up, 26 patients died and 35 were lost to follow-up. Thirteen (10.2%) had been reoperated. This left 53 patients for personal clinical assessment. Forty-nine consented to standardized radiographic evaluation for assessment of osteoarthritis, 36 patients underwent magnetic resonance imaging, allowing assessment of tendon healing, atrophy, and fatty infiltration (FI) of the cuff muscles. RESULTS: The final Constant-Murley score (CS) was 68 ± 17.7 (range, 8-91) vs. 44 ± 15.3 (range, 13-74) preoperatively (P < .05). The final Subjective Shoulder Value (SSV) was 73% ± 23% (range, 0-100). Retears (Sugaya IV and V) were found in 17 cases (47%). Nine patients (17%) had cuff tear arthropathy (Hamada stage 4). The CS and SSV for the shoulders with FI stages III or IV were significantly inferior (53 ± 19 points and 65% ± 14% respectively) than for those with FI stages 0-II (respectively, 71.6 ± 6 points and 73% ± 4%) (P < .05). CONCLUSIONS: Twenty years after surgical repair of massive rotator cuff tears, the functional scores remain satisfactory, and the rate of revision is low.


Assuntos
Osteoartrite/epidemiologia , Lesões do Manguito Rotador/cirurgia , Artropatia de Ruptura do Manguito Rotador/epidemiologia , Adulto , Idoso , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Recidiva , Reoperação , Estudos Retrospectivos , Lesões do Manguito Rotador/complicações , Lesões do Manguito Rotador/patologia , Fatores de Tempo , Resultado do Tratamento
18.
Int Orthop ; 44(3): 519-530, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31900574

RESUMO

PURPOSE: To determine how different combinations of humeral stem and glenosphere designs for reverse shoulder arthroplasty (RSA) influence range of motion (ROM) and muscle elongation. METHODS: A computed tomography scan of a non-pathologic shoulder was used to simulate all shoulder motions, and thereby compare the ROM and rotator cuff muscle lengths of the native shoulder versus 30 combinations of humeral components (1 inlay straight stem with 155° inclination and five onlay curved stems with 135°, 145° or 155° inclinations, using concentric, medialized or lateralized trays) and glenospheres (standard, large, lateralized, inferior eccentric and bony increased-offset (BIO-RSA)). RESULTS: Only five of the 30 combinations restored ≥ 50% of the native ROM in all directions: the 145° onlay stem (concentric tray) combined with lateralized or inferior eccentric glenospheres and the 145° stem (lateralized tray) combined with either a large, lateralized or inferior eccentric glenosphere. Lengthening of the supraspinatus and infraspinatus, observed for all configurations, was greatest using onlay stems (7-30%) and BIO-RSA glenospheres (13-31%). Subscapularis lengthening was observed for onlay stems combined with BIO-RSA glenospheres (5-9%), while excessive subscapularis shortening was observed for the inlay stem combined with all glenospheres except the BIO-RSA design (> 15%). CONCLUSIONS: The authors suggest implanting 145° onlay stems, with concentric or lateralized trays, together with lateralized or inferior eccentric glenospheres.


Assuntos
Artroplastia do Ombro , Articulação do Ombro/cirurgia , Prótese de Ombro , Idoso , Artroplastia do Ombro/instrumentação , Artroplastia do Ombro/métodos , Simulação por Computador , Humanos , Úmero/diagnóstico por imagem , Úmero/cirurgia , Imageamento Tridimensional , Masculino , Desenho de Prótese , Amplitude de Movimento Articular/fisiologia , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Escápula/diagnóstico por imagem , Escápula/cirurgia , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X
19.
Eur J Orthop Surg Traumatol ; 30(1): 83-87, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31385038

RESUMO

PURPOSE: To compare the clinical outcomes of self-locking T-tenotomy called "tomydesis" to three different techniques of tenodesis for lesions of the long head of the biceps tendon (LHBT) associated with rotator cuff tears. HYPOTHESIS: Tomydesis could provide similar clinical outcomes than the other LHBT tenodesis techniques. METHODS: This prospective multicentre study included 77 patients who underwent rotator cuff repair concomitant with one of four surgical techniques on the LHBT. All patients had a minimum of 6-month follow-up post-operatively. Outcomes were evaluated based on the Constant score, SSV, pain on visual analogue scale, biceps-specific pain and Popeye deformity on photographs. RESULTS: There was no difference for the pain at the biceps muscle belly (p = 0.58), the bicipital groove (p = 0.69) and during resisted supination (p = 0.53), as well as for muscle cramps (p = 0.09), VAS for pain (p = 0.12) and Popeye deformity (p = 0.18). There was more pain in resisted flexion in the tomydesis group (p = 0.032), and significantly better Constant scores and SSV (< 0.001) in the patients who underwent the double lasso loop technique, but non-repairable cuff tears were most frequent in the tomydesis group. CONCLUSIONS: Tomydesis might be a reliable alternative that combines advantages of tenodesis and tenotomy. It should be considered in cases of rotator cuff tears, whose repair and healing are the key for good functional outcomes. LEVEL OF EVIDENCE: II.


Assuntos
Artroscopia/métodos , Procedimentos de Cirurgia Plástica/métodos , Lesões do Manguito Rotador/cirurgia , Traumatismos dos Tendões/cirurgia , Tenodese/métodos , Tenotomia/métodos , Adulto , Idoso , Estudos de Coortes , Feminino , Seguimentos , Humanos , Escala de Gravidade do Ferimento , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo , Traumatismo Múltiplo/diagnóstico por imagem , Traumatismo Múltiplo/cirurgia , Músculo Esquelético/lesões , Músculo Esquelético/cirurgia , Variações Dependentes do Observador , Medição da Dor , Cuidados Pós-Operatórios/reabilitação , Estudos Prospectivos , Amplitude de Movimento Articular/fisiologia , Recuperação de Função Fisiológica , Lesões do Manguito Rotador/diagnóstico por imagem , Traumatismos dos Tendões/diagnóstico por imagem , Fatores de Tempo
20.
J Shoulder Elbow Surg ; 28(10): 2023-2030, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31405717

RESUMO

BACKGROUND: Results of anatomic shoulder arthroplasty for glenohumeral osteoarthritis with severe glenoid retroversion are unpredictable with a high rate of glenoid loosening. Reverse shoulder arthroplasty (RSA) has been suggested as an alternative, with good early results. We sought to confirm this at longer follow-up (minimum 5 years). The study hypothesis was that early results would endure over time. METHODS: We retrospectively reviewed all RSAs performed in 7 centers from 1998 to 2010. The inclusion criteria were primary glenohumeral osteoarthritis with B1, B2, B3, or C glenoid. Forty-nine shoulders in 45 patients fulfilled the criteria. Bone grafting was performed in 16 cases. Clinical outcomes were evaluated with the Constant score (CS) and shoulder range of motion. RESULTS: The mean total CS increased from 30 preoperatively to 68 points (P < .001) with significant improvements in all the subsections of the CS and range of motion. Scapular notching was observed in 20 shoulders (43%), grade 1 in 5 (11%), grade 2 in 7 (15%), grade 3 in 5 (11%), and grade 4 in 3 (6%). The glenoid bone graft healed in all the shoulders. Partial inferior lysis of the bone graft was present in 8 cases (50%). Scapular notching and glenoid bone graft resorption had no influence on the CS (P = .147 and P = .798). CONCLUSION: RSA for the treatment of primary glenohumeral osteoarthritis in patients with posterior glenoid deficiency and humeral subluxation without rotator cuff insufficiency resulted in excellent clinical outcomes at a minimum of 5 years of follow-up.


Assuntos
Artroplastia do Ombro/métodos , Cavidade Glenoide/cirurgia , Osteoartrite/cirurgia , Luxação do Ombro/cirurgia , Articulação do Ombro/cirurgia , Idoso , Artroplastia do Ombro/efeitos adversos , Transplante Ósseo , Feminino , Seguimentos , Cavidade Glenoide/patologia , Humanos , Masculino , Osteoartrite/complicações , Amplitude de Movimento Articular , Estudos Retrospectivos , Luxação do Ombro/complicações , Articulação do Ombro/fisiopatologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA