RESUMO
AIMS: Additional randomized clinical trial (RCT) data comparing transcatheter aortic valve implantation (TAVI) with surgical aortic valve replacement (SAVR) is available, including longer term follow-up. A meta-analysis comparing TAVI to SAVR was performed. A pragmatic risk classification was applied, partitioning lower-risk and higher-risk patients. METHODS AND RESULTS: The main endpoints were death, strokes, and the composite of death or disabling stroke, occurring at 1 year (early) or after 1 year (later). A random-effects meta-analysis was performed. Eight RCTs with 8698 patients were included. In lower-risk patients, at 1 year, the risk of death was lower after TAVI compared with SAVR [relative risk (RR) 0.67; 95% confidence interval (CI) 0.47 to 0.96, P = 0.031], as was death or disabling stroke (RR 0.68; 95% CI 0.50 to 0.92, P = 0.014). There were no differences in strokes. After 1 year, in lower-risk patients, there were no significant differences in all main outcomes. In higher-risk patients, there were no significant differences in main outcomes. New-onset atrial fibrillation, major bleeding, and acute kidney injury occurred less after TAVI; new pacemakers, vascular complications, and paravalvular leak occurred more after TAVI. CONCLUSION: In lower-risk patients, there was an early mortality reduction with TAVI, but no differences after later follow-up. There was also an early reduction in the composite of death or disabling stroke, with no difference at later follow-up. There were no significant differences for higher-risk patients. Informed therapy decisions may be more dependent on the temporality of events or secondary endpoints than the long-term occurrence of main clinical outcomes.
Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Acidente Vascular Cerebral , Humanos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologiaRESUMO
AIMS: The optimal method of revascularization for patients with left main coronary artery disease (LMCAD) is controversial. Coronary artery bypass graft surgery (CABG) has traditionally been considered the gold standard therapy, and recent randomized trials comparing CABG with percutaneous coronary intervention (PCI) with drug-eluting stents (DES) have reported conflicting outcomes. We, therefore, performed a systematic review and updated meta-analysis comparing CABG to PCI with DES for the treatment of LMCAD. METHODS AND RESULTS: We systematically identified all randomized trials comparing PCI with DES vs. CABG in patients with LMCAD. The primary efficacy endpoint was all-cause mortality. Secondary endpoints included cardiac death, myocardial infarction (MI), stroke, and unplanned revascularization. All analyses were by intention-to-treat. There were five eligible trials in which 4612 patients were randomized. The weighted mean follow-up duration was 67.1 months. There were no significant differences between PCI and CABG for the risk of all-cause mortality [relative risk (RR) 1.03, 95% confidence interval (CI) 0.81-1.32; P = 0.779] or cardiac death (RR 1.03, 95% CI 0.79-1.34; P = 0.817). There were also no significant differences in the risk of stroke (RR 0.74, 95% CI 0.35-1.50; P = 0.400) or MI (RR 1.22, 95% CI 0.96-1.56; P = 0.110). Percutaneous coronary intervention was associated with an increased risk of unplanned revascularization (RR 1.73, 95% CI 1.49-2.02; P < 0.001). CONCLUSION: The totality of randomized clinical trial evidence demonstrated similar long-term mortality after PCI with DES compared with CABG in patients with LMCAD. Nor were there significant differences in cardiac death, stroke, or MI between PCI and CABG. Unplanned revascularization procedures were less common after CABG compared with PCI. These findings may inform clinical decision-making between cardiologists, surgeons, and patients with LMCAD.
Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Ponte de Artéria Coronária , Doença da Artéria Coronariana/cirurgia , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do TratamentoRESUMO
BACKGROUND: The per-vessel level impact of physiological pattern of disease on the discordance between fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) has not been clarified.MethodsâandâResults:Using the AJIP registry, vessels with FFR/iFR discordance (133/671 [19.8%]) were analyzed. In the left anterior descending artery (LAD), physiologically diffuse disease, as assessed by pressure-wire pullback, was associated with FFR-/iFR+ (83.3% [40/48]), while physiologically focal disease was associated with FFR+/iFR- (57.4% [31/54]), significantly (P<0.0001). These differences were not significant in non-LAD (P=0.17). CONCLUSIONS: The impact of physiological pattern of disease on FFR/iFR discordance is more pronounced in the LAD.
Assuntos
Cateterismo Cardíaco , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sistema de Registros , Índice de Gravidade de DoençaRESUMO
For identification of myocardial ischaemia by non-invasive imaging or invasive physiological assessment, administration of a vasodilating or positive inotropic agent is often considered indispensable to exhaust the cardiac compensation mechanisms. Indeed, microcirculatory dilatation is needed for assessment of myocardial perfusion or coronary blood flow. However, three different modalities exist that quantify myocardial ischaemia without recourse to pharmacological stress agents, using either myocardial contrast echocardiography, imaging of myocardial blood volume or invasive coronary pressure measurement with the instantaneous wave-free ratio (iFR). The theoretical framework of these vasodilator-free modalities revolves around the two innate mechanisms that protect the myocardium from ischaemia at rest: coronary autoregulation and arteriogenesis. Coronary autoregulation and metabolic dilatation form the putative processes that regulate microvascular tone and constitute of a complex interplay between metabolic factors, myogenic control, and endothelium-based control that each interact with coronary arterioles of a different size. Arteriogenesis describes the development of large calibre collateral arteries from a pre-existing network, triggered by occlusive coronary artery disease. Following these descriptions, the fundamental principles and the existing evidence of these three diagnostic modalities are reviewed. Emphasis is placed on iFR, which is clinically best applicable. Instantaneous wave-free ratio has proven to be an effective method to determine the haemodynamic significance of coronary stenoses in two recent large randomized clinical trials, together enrolling over 4500 patients. Ultimately, this review aims to clarify the theoretical rationale and to describe the clinical implications of functional stenosis assessment under resting conditions.
Assuntos
Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Microcirculação/fisiologia , Vasodilatação/fisiologia , Angiografia Coronária , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Homeostase , Humanos , Índice de Gravidade de Doença , VasodilatadoresRESUMO
OBJECTIVE: To investigate the immediate and short term impact of right coronary artery (RCA) chronic total coronary occlusion (CTO) percutaneous coronary intervention (PCI) upon collateral donor vessel fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR). BACKGROUND: CTO PCI influences collateral donor vessel physiology, making the indication and/or timing of donor vessel revascularization difficult to determine. METHODS: In patients with RCA CTO, FFR, iFR, and collateral function index (FFRcoll ) were measured in LAD and LCx pre-CTO PCI, immediately post and at 4 month follow-up. RESULTS: 34 patients underwent successful PCI. In the predominant donor vessel immediately post PCI, FFR, and FFRcoll did not change (0.76 ± 0.12 to 0.75 ± 0.13, P = 0.267 and 0.31 ± 0.10 vs. 0.34 ± 0.11, P = 0.078), but iFR increased significantly (0.86 ± 0.10 to 0.88 ± 0.10, P = 0.012). At follow-up, there was a significant increase in predominant donor FFR and iFR (0.76 ± 0.12 to 0.79 ± 0.11, P = 0.047 and 0.86 ± 0.10 to 0.90 ± 0.07, P = 0.003), accompanied by a significant reduction in FFRcoll (0.31 ± 0.10 to 0.18 ± 0.07 P < 0.0001). These changes resulted in a reclassification of the predominant donor vessel from ischemic to nonischemic in 18% (FFR) and 25% (iFR) of the cases, respectively. CONCLUSIONS: Successful recanalization of an RCA CTO resulted in a modest but statistically significant increase in the predominant donor vessel immediately post CTO PCI in the case of iFR and at 4-month follow-up for FFR and iFR compared to pre-PCI with a concomitant reduction in collateral function.
Assuntos
Angina Estável/terapia , Cateterismo Cardíaco , Circulação Colateral , Oclusão Coronária/terapia , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Idoso , Angina Estável/diagnóstico , Angina Estável/fisiopatologia , Doença Crônica , Tomada de Decisão Clínica , Angiografia Coronária , Oclusão Coronária/diagnóstico , Oclusão Coronária/fisiopatologia , Stents Farmacológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Valor Preditivo dos Testes , Fatores de Tempo , Resultado do TratamentoRESUMO
Intracoronary continuous thermodilution has been recently proposed as an invasive method to quantify absolute coronary flow (Qabs) and resistance (Rabs) in vivo. The aim of the present study is to develop and validate of a novel pressure-wire- and microcatheter-free surrogate of coronary flow and resistance derived from a standard coronary angiogram. Angiography derived coronary flow (Qangio) and resistance (Rangio) was prospectively validated in a two-center cohort of patients from Oxford Heart Centre and the Essex Cardiothoracic Centre. Qabs and Rabs were measured during resting and hyperemic conditions with continuous thermodilution using the Rayflow microcatheter. Qangio and Rangio were computed from the diagnostic coronary angiogram in a blinded fashion in resting and hyperemic conditions. A total of 62 patients and 115 vessels were included in the present analysis. The median Qabs at rest was 75 ml/min (53-95) and 151 ml/min (105-203) during hyperemia; Qangio at rest was 84 ml/min (66-108) and 154 ml/min (115-195) during hyperemia. There was a strong correlation between Qabs and Qangio (R = 0,72; p < 0.001, R = 0,86; p < 0.001 respectively) with satisfactory interclass correlation (0.841, 95% CI 0.509-0.957; p = 0.0003). The median Rabs was 1111 mmHg/(L/min) (830-1581.4) at rest and 454 mmHg/(L/min) (348-610) during hyperemia; angiographic resistance (Rangio) was 937.4 mmHg/(L/min) (695.4-1261.9) at rest and 492.4 mmHg/(L/min) (406-697) during hyperemia. There was a strong correlation between Rabs and Rangio in both conditions (R = 0,81; p < 0.001 and R = 0,78; p < 0.001 respectively). The was a good correlation between absolute coronary flow reserve (CFR) and angiography-derived CFR (R = 0,61; p < 0.001) and between absolute microvascular resistance reserve (MRR) and angiography-derived MRR (R = 0,49; p < 0.001).
Assuntos
Cateterismo Cardíaco , Angiografia Coronária , Doença da Artéria Coronariana , Circulação Coronária , Vasos Coronários , Hiperemia , Valor Preditivo dos Testes , Termodiluição , Resistência Vascular , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Prospectivos , Idoso , Reprodutibilidade dos Testes , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Hiperemia/fisiopatologia , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Cateteres Cardíacos , Transdutores de PressãoRESUMO
Background: To assess whether hydrostatic pressure gradients caused by coronary height differences in supine versus prone positioning during invasive physiological stenosis assessment affect resting and hyperaemic pressure-based indices or coronary flow. Methods: Twenty-three coronary stenoses were assessed in twenty-one patients with stable coronary artery disease. All patients had a stenosis of at least 50% visually defined on previous coronary angiography. Pd/Pa, iFR, FFR, and coronary flow velocity (APV) measured using a Doppler were recorded across the same stenosis, with the patient in the prone position, followed by repeat measurements in the standard supine position. Results: When comparing prone to supine measurements in the same stenosis, in the LAD, there was a significant change in mean Pd/Pa of 0.08 ± 0.04 (p = 0.0006), in the iFR of 0.06 ± 0.07 (p = 0.02), and in the FFR of 0.09 ± 0.07 (p = 0.003). In the Cx, there was a change in mean Pd/Pa of 0.05 ± 0.04 (p = 0.009), iFR of 0.07 ± 0.04 (p = 0.01), and FFR of 0.05 ± 0.03 (p = 0.006). In the RCA, there was a change in Pd/Pa of 0.05 ± 0.04 (p = 0.032), iFR of 0.04 ± 0.05 (p = 0.19), and FFR of 0.04+-0.03 (p = 0.004). Resting and hyperaemic coronary flow did not change significantly (resting delta APV = 1.6 cm/s, p = 0.31; hyperaemic delta APV = 0.9 cm/s, p = 0.85). Finally, 36% of iFR measurements and 26% of FFR measurements were re-classified across an ischaemic threshold when prone and supine measurements were compared across the same stenosis. Conclusions: Pd/Pa, iFR, and FFR were affected by hydrostatic pressure variations caused by coronary height differences in prone versus supine positioning. Coronary flow did not change signifying a purely pressure-based phenomenon.
RESUMO
Continuous Thermodilution is a novel method of quantifying coronary flow (Q) in mL/min. To account for variability of Q within the cardiac cycle, the trace is smoothened with a 2 s moving average filter. This can sometimes be ineffective due to significant heart rate variability, ventricular extrasystoles, and deep inspiration, resulting in a fluctuating temperature trace and ambiguity in the location of the "steady state". This study aims to assess whether a longer moving average filter would smoothen any fluctuations within the continuous thermodilution traces resulting in improved interpretability and reproducibility on a test-retest basis. Patients with ANOCA underwent repeat continuous thermodilution measurements. Analysis of traces were performed at averages of 10, 15, and 20 s to determine the maximum acceptable average. The maximum acceptable average was subsequently applied as a moving average filter and the traces were re-analysed to assess the practical consequences of a longer moving average. Reproducibility was then assessed and compared to a 2 s moving average. Of the averages tested, only 10 s met the criteria for acceptance. When the data was reanalysed with a 10 s moving average filter, there was no significant improvement in reproducibility, however, it resulted in a 12% diagnostic mismatch. Applying a longer moving average filter to continuous thermodilution data does not improve reproducibility. Furthermore, it results in a loss of fidelity on the traces, and a 12% diagnostic mismatch. Overall, current practice should be maintained.
RESUMO
Despite guideline-based recommendation of the interchangeable use of instantaneous wave-free ratio (iFR) and fractional flow reserve (FFR) to guide revascularization decision-making, iFR/FFR could demonstrate different physiological or clinical outcomes in some specific patient or lesion subsets. Therefore, we sought to investigate the impact of difference between iFR and FFR-guided revascularization decision-making on clinical outcomes in patients with left main disease (LMD). In this international multicenter registry of LMD with physiological interrogation, we identified 275 patients in whom physiological assessment was performed with both iFR/FFR. Major adverse cardiovascular event (MACE) was defined as a composite of death, non-fatal myocardial infarction, and ischemia-driven target lesion revascularization. The receiver-operating characteristic analysis was performed for both iFR/FFR to predict MACE in respective patients in whom revascularization was deferred and performed. In 153 patients of revascularization deferral, MACE occurred in 17.0% patients. The optimal cut-off values of iFR and FFR to predict MACE were 0.88 (specificity:0.74; sensitivity:0.65) and 0.76 (specificity:0.81; sensitivity:0.46), respectively. The area under the curve (AUC) was significantly higher for iFR than FFR (0.74; 95%CI 0.62-0.85 vs. 0.62; 95%CI 0.48-0.75; p = 0.012). In 122 patients of coronary revascularization, MACE occurred in 13.1% patients. The optimal cut-off values of iFR and FFR were 0.92 (specificity:0.93; sensitivity:0.25) and 0.81 (specificity:0.047; sensitivity:1.00), respectively. The AUCs were not significantly different between iFR and FFR (0.57; 95%CI 0.40-0.73 vs. 0.46; 95%CI 0.31-0.61; p = 0.43). While neither baseline iFR nor FFR was predictive of MACE in patients in whom revascularization was performed, iFR-guided deferral seemed to be safer than FFR-guided deferral.
Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Humanos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Masculino , Feminino , Idoso , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/diagnóstico , Pessoa de Meia-Idade , Angiografia Coronária , Sistema de Registros , Revascularização Miocárdica/métodos , Curva ROC , Cateterismo Cardíaco/métodos , Estudos RetrospectivosRESUMO
Background: The assessment of coronary microvascular dysfunction (CMD) using invasive methods is a field of growing interest, however the preferred method remains debated. Bolus and continuous thermodilution are commonly used methods, but weak agreement has been observed in patients with angina with non-obstructive coronary arteries (ANOCA). This study examined their agreement in revascularized acute coronary syndromes (ACS) and chronic coronary syndromes (CCS) patients. Objective: To compare bolus thermodilution and continuous thermodilution indices of CMD in revascularized ACS and CCS patients and assess their diagnostic agreement at pre-defined cut-off points. Methods: Patients from two centers underwent paired bolus and continuous thermodilution assessments after revascularization. CMD indices were compared between the two methods and their agreements at binary cut-off points were assessed. Results: Ninety-six patients and 116 vessels were included. The mean age was 64 ± 11 years, and 20 (21 %) were female. Overall, weak correlations were observed between the Index of Microcirculatory Resistance (IMR) and continuous thermodilution microvascular resistance (Rµ) (rho = 0.30p = 0.001). The median coronary flow reserve (CFR) from continuous thermodilution (CFRcont) and bolus thermodilution (CFRbolus) were 2.19 (1.76-2.67) and 2.55 (1.50-3.58), respectively (p < 0.001). Weak correlation and agreement were observed between CFRcont and CFRbolus (rho = 0.37, p < 0.001, ICC 0.228 [0.055-0.389]). When assessed at CFR cut-off values of 2.0 and 2.5, the methods disagreed in 41 (35 %) and 45 (39 %) of cases, respectively. Conclusions: There is a significant difference and weak agreement between bolus and continuous thermodilution-derived indices, which must be considered when diagnosing CMD in ACS and CCS patients.
RESUMO
Despite the now routine integration of invasive physiologic systems into coronary catheter laboratories worldwide, it remains critical that all operators maintain a sound understanding of the fundamental physiologic basis for coronary pressure assessment. More specifically, performing operators should be well informed regarding the basis for hyperemic (ie, fractional flow reserve) and nonhyperemic (ie, instantaneous wave-free ratio and other nonhyperemic pressure ratio) coronary pressure assessment. In this article, we provide readers a comprehensive history charting the inception, development, and validation of hyperemic and nonhyperemic coronary pressure assessment.
Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Hiperemia , Humanos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Cateterismo Cardíaco , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Hiperemia/diagnósticoRESUMO
The landscape of interventional cardiology is ever evolving. Contemporary practice has shifted from a stenosis-centred approach to the total characterisation of both the epicardial and microcirculatory vessels. Microcirculatory dysfunction plays an important role in the pathophysiology of acute and chronic coronary syndromes, and characterisation of the microcirculation has important clinical consequences. Accordingly, the invasive diagnosis of microcirculatory dysfunction is becoming a key feature of the interventional cardiologist's toolkit. This review focuses on the methodology underpinning the invasive diagnosis of microvascular dysfunction and highlights the indices that have arisen from these methodologies.
RESUMO
Background: Percutaneous coronary intervention (PCI) for coronary chronic total occlusion (CTO) has been performed for the improvement of symptoms and quality of life in patients with stable angina. The ORBITA study demonstrated the role of the placebo effect in contemporary PCI in non-CTO chronic coronary syndromes. However, the benefit of CTO PCI beyond that of a placebo has not been demonstrated. Aims: The ORBITA-CTO pilot study will be a double-blind, placebo-controlled study of CTO PCI randomising patients who have: (1) been accepted by a CTO operator for PCI; (2) experienced symptoms due to a CTO; (3) evidence of ischaemia; (4) evidence of viability within the CTO territory; and (5) a J-CTO score ≤3. Methods: Patients will undergo medication optimisation that will ensure they are on at least a minimum amount of anti-anginals and complete questionnaires. Patients will record their symptoms on an app daily throughout the study. Patients will undergo randomisation procedures, including an overnight stay, and be discharged the following day. All anti-anginals will be stopped after randomisation and re-initiated on a patient-led basis during the 6-month follow-up period. At follow-up, patients will undergo repeat questionnaires and unblinding, with a further 2-week unblinded follow-up. Results: The co-primary outcomes are feasibility (blinding) in this cohort and angina symptom score using an ordinal clinical outcome scale for angina. Secondary outcomes include changes in quality-of-life measures, Seattle Angina Questionnaire (SAQ), peak VO2, and anaerobic threshold on the cardiopulmonary exercise test. Conclusion: The feasibility of a placebo-controlled CTO PCI study will lead to future studies assessing efficacy. The impact of CTO PCI on angina measured using a novel daily symptom app may provide improved fidelity in assessing symptoms in patients with CTO's.
RESUMO
BACKGROUND: Randomised studies of percutaneous coronary intervention (PCI) in patients with chronic total occlusion (CTO) have shown inconsistent outcomes, suggesting incomplete understanding of this cohort and their coronary physiology. To address this shortcoming, we designed a prospective observational study to measure the recovery of absolute coronary blood flow following successful CTO PCI Aims: We sought to identify patient and procedural characteristics associated with a favourable physiological outcome after CTO PCI. METHODS: Consecutive patients with a CTO subtending viable myocardium underwent PCI utilising contemporary techniques and the hybrid algorithm. Immediately after PCI, and at 3-month follow-up, physiological measurements were performed utilising continuous thermodilution. RESULTS: A total of 81 patients were included with a mean age of 63.6±8.9 years, and 66 (81.5%) were male. Physiological measurements of absolute coronary blood flow in the CTO vessel increased by 30% (p<0.001) and microvascular resistance reduced by 16% (p<0.001) from immediately post-CTO PCI to follow-up assessment. Fractional flow reserve increased by 0.02 (p=0.015) in the same period. Prior coronary artery bypass graft (CABG) and a higher estimated glomerular filtration rate (eGFR) were associated with a larger change in absolute flow. An extraplaque strategy was associated with a smaller change in absolute flow. CONCLUSIONS: Post-CTO PCI, there is a continued augmentation in absolute coronary blood flow and reduction in microvascular resistance from baseline to follow-up at 3 months. Prior CABG and a higher baseline eGFR were predictors of a larger change in absolute coronary flow, whilst an extraplaque final wire path strategy predicted a smaller change. Lastly, the patient characteristics and comorbidities had a larger influence than procedural factors on the observed change in absolute flow.
Assuntos
Oclusão Coronária , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Resultado do Tratamento , Oclusão Coronária/cirurgia , Intervenção Coronária Percutânea/métodos , Angiografia Coronária , Miocárdio , Doença Crônica , Fatores de RiscoRESUMO
There have been no studies comparing clinical outcomes of physiology-guided revascularization in patients with unprotected left main coronary disease (ULMD) between percutaneous coronary intervention (PCI) vs. coronary artery bypass grafting (CABG). The aim of this study was to assess the long-term clinical outcomes between PCI and CABG of patients with physiologically significant ULMD. From an international multicenter registry of ULMD patients interrogated with instantaneous wave-free ratio (iFR), we analyzed data from 151 patients (85 PCI vs. 66 CABG) who underwent revascularization according to the cutoff value of iFR ≤ 0.89. Propensity score matching was employed to adjust for baseline clinical characteristics. The primary endpoint was a composite of all-cause death, non-fatal myocardial infarction, and ischemia-driven target lesion revascularization. The secondary endpoints were the individual components of the primary endpoint. Mean age was 66.6 (± 9.2) years, 79.2% male. Mean SYNTAX score was 22.6 (± 8.4) and median iFR was 0.83 (IQR 0.74-0.87). After performing propensity score matching analysis, 48 patients treated with CABG were matched to those who underwent PCI. At a median follow-up period of 2.8 years, the primary endpoint occurred in 8.3% in PCI group and 20.8% in CABG group, respectively (HR 3.80; 95% CI 1.04-13.9; p = 0.043). There was no difference in each component of the primary event (p > 0.05 for all). Within the present study, iFR-guided PCI was associated with lower cardiovascular events rate in patients with ULMD and intermediate SYNTAX score, as compared to CABG. State-of-the-art PCI vs. CABG for ULMD. Study design and primary endpoint in patients with physiologically significant ULMD. MACE was defined as the composite of all-cause death, non-fatal myocardial infarction, and target lesion revascularization. The blue line denotes the PCI arm, and the red line denotes the CABG arm. PCI was associated with significantly lower risk of MACE than CABG. CABG: coronary artery bypass grafting; iFR: instantaneous wave-free ratio; MACE: major adverse cardiovascular events; PCI: percutaneous coronary intervention; ULMD: unprotected left main coronary artery disease.
Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Masculino , Idoso , Feminino , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/complicações , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Ponte de Artéria Coronária/efeitos adversos , Infarto do Miocárdio/etiologia , Sistema de Registros , Fatores de RiscoRESUMO
BACKGROUND: The majority of randomized controlled trials of revascularization decision-making excludes left main coronary artery disease (LMD). Therefore, contemporary clinical outcomes of patients with stable coronary artery disease and LMD with proven ischemia remain poorly understood. The aim of this study was to assess the long-term clinical outcomes of physiologically significant LMD according to the treatment strategies of revascularization versus revascularization deferral. METHODS: In this international multicenter registry of stable LMD interrogated with the instantaneous wave-free ratio, patients with physiologically significant ischemia (instantaneous wave-free ratio ≤0.89) were analyzed according to the coronary revascularization (n=151) versus revascularization deferral (n=74). Propensity score matching was performed to adjust for baseline clinical characteristics. The primary end point was a composite of death, nonfatal myocardial infarction, and ischemia-driven target lesion revascularization of left main stem. The secondary end points were as follows: cardiac death or spontaneous LMD-related myocardial infarction; and ischemia-driven target lesion revascularization of left main stem. RESULTS: At a median follow-up period of 2.8 years, the primary end point occurred in 11 patients (14.9%) in the revascularized group and 21 patients (28.4%) in the deferred group (hazard ratio, 0.42 [95% CI, 0.20-0.89]; P=0.023). For the secondary end points, cardiac death or LMD-related myocardial infarction occurred significantly less frequently in the revascularized group (0.0% versus 8.1%; P=0.004). The rate of ischemia-driven target lesion revascularization of left main stem was also significantly lower in the revascularized group (5.4% versus 17.6%; hazard ratio, 0.20 [95% CI, 0.056-0.70]; P=0.012). CONCLUSIONS: In patients who underwent revascularization for stable coronary artery disease and physiologically significant LMD determined by instantaneous wave-free ratio, the long-term clinical outcomes were significantly improved as compared with those in whom revascularization was deferred.
Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Resultado do Tratamento , Infarto do Miocárdio/etiologia , Ponte de Artéria Coronária/efeitos adversos , Revascularização Miocárdica/efeitos adversos , Morte , Intervenção Coronária Percutânea/efeitos adversosRESUMO
Aims: Coronary flow reserve (CFR) assessment has proven clinical utility, but Doppler-based methods are sensitive to noise and operator bias, limiting their clinical applicability. The objective of the study is to expand the adoption of invasive Doppler CFR, through the development of artificial intelligence (AI) algorithms to automatically quantify coronary Doppler quality and track flow velocity. Methods and results: A neural network was trained on images extracted from coronary Doppler flow recordings to score signal quality and derive values for coronary flow velocity and CFR. The outputs were independently validated against expert consensus. Artificial intelligence successfully quantified Doppler signal quality, with high agreement with expert consensus (Spearman's rho: 0.94), and within individual experts. Artificial intelligence automatically tracked flow velocity with superior numerical agreement against experts, when compared with the current console algorithm [AI flow vs. expert flow bias -1.68 cm/s, 95% confidence interval (CI) -2.13 to -1.23 cm/s, P < 0.001 with limits of agreement (LOA) -4.03 to 0.68 cm/s; console flow vs. expert flow bias -2.63 cm/s, 95% CI -3.74 to -1.52, P < 0.001, 95% LOA -8.45 to -3.19 cm/s]. Artificial intelligence yielded more precise CFR values [median absolute difference (MAD) against expert CFR: 4.0% for AI and 7.4% for console]. Artificial intelligence tracked lower-quality Doppler signals with lower variability (MAD against expert CFR 8.3% for AI and 16.7% for console). Conclusion: An AI-based system, trained by experts and independently validated, could assign a quality score to Doppler traces and derive coronary flow velocity and CFR. By making Doppler CFR more automated, precise, and operator-independent, AI could expand the clinical applicability of coronary microvascular assessment.
RESUMO
BACKGROUND AND AIMS: The management of chronic coronary syndrome (CCS) is informed by studies predominantly including men. This study investigated the relationship between patients sex and different endotypes of CCS, including sex-specific clinical outcomes. METHODS: In patients with CCS undergoing coronary angiography, invasive Fractional Flow Reserve (FFR) and Coronary Flow Reserve (CFR) were measured. Patients were stratified into groups: 1) obstructive coronary artery disease (oCAD) (FFR≤0.80, no revascularization), 2) undergoing revascularization, 3) non-obstructive coronary artery disease with coronary microvascular dysfunction (CMD) (FFR>0.80, CFR≤2.5), and 4) non-obstructive coronary artery disease without CMD (FFR>0.80 and CFR>2.5). RESULTS: 1836 patients (2335 vessels) were included, comprising 1359 (74.0%) men and 477 (26.0%) women. oCAD was present in 14.1% and was significantly less prevalent in women than in men (10.3% vs 15.5%, respectively p < 0.01). Revascularization was present in 30.9% and was similarly prevalent in women and men (28.2% vs. 31.9%, respectively p = 0.13). CMD was present in 24.2% and was significantly more prevalent in women than men (28.6% vs 22.6%, respectively p < 0.01). Normal invasive measurements were found in 564 patients (33.0% women vs 30.0% men, p = 0.23). Male sex was associated with an increased risk of target vessel failure compared to women (HR.1.89, 95% CI 1.12-3.18, p = 0.018), regardless of CCS-endotype. CONCLUSIONS: Sex differences exist in the prevalence and outcomes of different endotypes of CCS in symptomatic patients undergoing invasive coronary angiography. In particular, oCAD (and subsequent revascularization) were more prevalent in men. Conversely, CMD was more prevalent in women. Overall, men experienced a worse cardiovascular outcome compared to women, independent of any specific CCS endotype.
Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Isquemia Miocárdica , Humanos , Masculino , Feminino , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/terapia , Angiografia Coronária , Prevalência , Caracteres Sexuais , Sistema de RegistrosRESUMO
Objectives: Coronary artery bypass grafting (CABG) is performed using anatomic guidance. Data connecting the physiologic significance of the coronary vessel stenosis to the acute physiologic response to grafting are lacking. The Collaborative Pilot Study to Determine the Correlation Between Intraoperative Observations Using Spy Near-Infrared Imaging and Cardiac Catheterization Laboratory Physiological Assessment of Lesion Severity study is the first to compare preintervention coronary physiology with the acute regional myocardial perfusion change (RMP-QC) at CABG in a per-graft analysis. Methods: Non-emergent patients undergoing diagnostic catheterization suitable for multivessel CABG were enrolled. Synergy between Percutaneous Coronary Intervention with Taxus score, fractional flow reserve (FFR), instantaneous wave free ratio (iFR), and quantitative coronary angiography was documented in 75 epicardial coronary arteries, with 62 angiographically intermediate and 13 severe stenoses. At CABG, near-infrared fluorescence analysis quantified the relative change (post- vs pregrafting, termed RMP-QC) in the grafted vessel's perfusion territory. Scatter plots were constructed for RMP-QC versus quantitative coronary angiography and RMP-QC versus FFR/iFR. Exact quadrant randomization test for randomness was used. Results: There was no relationship between RMP-QC and quantitative coronary angiography percent diameter stenosis, whether all study vessels were included (P = .949) or vessels with core-lab quantitative coronary angiography only (P = .922). A significant nonrandom association between RMP-QC and FFR (P = .025), as well as between RMP-QC and iFR (P = .008), was documented. These associations remained when excluding vessels with assigned FFR and iFR values (P = .0092 and P = .0006 for FFR and iFR, respectively). Conclusions: The Collaborative Pilot Study to Determine the Correlation Between Intraoperative Observations Using Spy Near-Infrared Imaging and Cardiac Catheterization Laboratory Physiological Assessment of Lesion Severity study demonstrates there is no association between angiographic coronary stenosis severity and the acute perfusion change after grafting; there is an association between functional stenosis severity and absolute increase in regional myocardial perfusion after CABG.
RESUMO
BACKGROUND: The efficacy of renal denervation has been controversial, but the procedure has now undergone several placebo-controlled trials. New placebo-controlled trial data has recently emerged, with longer follow-up of one trial and the full report of another trial (which constitutes 27% of the total placebo-controlled trial data). We therefore sought to evaluate the effect of renal denervation on ambulatory and office blood pressures in patients with hypertension. METHODS: We systematically identified all blinded placebo-controlled randomized trials of catheter-based renal denervation for hypertension. The primary efficacy outcome was ambulatory systolic blood pressure change relative to placebo. A random-effects meta-analysis was performed. RESULTS: 6 studies randomizing 1232 patients were eligible. 713 patients were randomized to renal denervation and 519 to placebo. Renal denervation significantly reduced ambulatory systolic blood pressure (-3.52 mmHg; 95% CI -4.94 to -2.09; p < 0.0001), ambulatory diastolic blood pressure (-1.93 mmHg; 95% CI -3.04 to -0.83, p = 0.0006), office systolic blood pressure size (-5.10 mmHg; 95% CI -7.31 to -2.90, p < 0.0001) and office diastolic pressure (effect size -3.11 mmHg; 95% CI -4.43 to -1.78, p < 0.0001). Adverse events were rare and not more common with denervation. CONCLUSIONS: The totality of blinded, randomized placebo-controlled data shows that renal denervation is safe and provides genuine reduction in blood pressure for at least 6 months post-procedure. If this effect continues in the long term, renal denervation might provide a life-long 10% relative risk reduction in major adverse cardiac events and 7.5% relative risk reduction in all-cause mortality.