Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 32(1): 110-116, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33179400

RESUMO

INTRODUCTION: In patients with sinus node disease (SND), the dual-chamber pacemaker (PM) is programmed in DDDR mode with an algorithm to avoid unnecessary right ventricular (RV) pacing. This pacing mode may prolong PR interval with consequently atrioventricular (AV) asynchrony which is associated with a higher risk of atrial fibrillation (AF). We evaluate whether preserving AV synchrony by setting a fixed AV delay during physiological RV pacing, that is, His bundle pacing (HBP), could reduce the risk of AF occurrence in comparison with a standard pacing mode with an algorithm to avoid unnecessary RV pacing (DDD-VPA). METHODS AND RESULTS: We collected retrospective data from 313 consecutive patients who had undergone PM for SND. The first occurrence of persistent AF (>7 consecutive days) as a function of the pacing mode was evaluated. HBP and DDD-VPA were implemented in 82 and 231 patients, respectively. Persistent AF occurred in 128 (40.9%) patients over a median follow-up of 70 months (67-105). The DDD-VPA pacing mode was significantly correlated with the occurrence of persistent AF only when the basal PR was long (>180 ms). The risk of persistent AF was significantly lower in patients on HBP than in those on DDD-VPA, adjusted HR = .57 (95% CI, .36- .89, p=.014). Other independent predictors of persistent AF occurrence were: A history of AF (HR = 3.91; 95% CI, 2.48-6.19, p = .001), age, and long PR interval (HR = 2.98; 95% CI, 2.00-4.43, p=.001). CONCLUSION: In SND patients and long basal PR interval, the HBP may reduce the risk of persistent AF in comparison with the DDD-VPA.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Humanos , Estudos Retrospectivos , Síndrome do Nó Sinusal/diagnóstico , Síndrome do Nó Sinusal/terapia
2.
Europace ; 20(11): e171-e178, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29294014

RESUMO

Aims: Right bundle branch block (RBBB) typically presents with only delayed right ventricular activation. However, some patients with RBBB develop concomitant delayed left ventricular (LV) activation. Such patients may show a specific electrocardiographic (ECG) pattern resembling RBBB in the precordial leads in association with an insignificant S-wave in lateral limb leads (atypical RBBB). We therefore postulated that the ECG pattern of atypical RBBB might be able to identify a subgroup of patients likely to respond to cardiac resynchronization therapy (CRT). The purpose of this study was to assess the impact of RBBB ECG morphology on CRT response in patients with heart failure (HF). Methods and results: We evaluated the echocardiographic clinical response of 66 patients with RBBB treated with CRT and followed up for almost 2 years. The patients were divided electrocardiographically into 2 groups: 31 with typical RBBB and 35 with atypical RBBB. Responders were classified in terms of reduction in LV end-systolic volume index (ESVi) ≥ 15% or reduction in the New York Heart Association (NYHA) Class ≥ 1 or Packer score variation (NYHA response with no HF-related hospitalization events or death). The atypical RBBB group presented a longer LV activation time compared with the typical RBBB group (111.9 ± 17.6 vs. 73.2 ± 15.4 ms; P < 0.001). In the atypical and typical RBBB groups, respectively, 71.4% and 19.4% of patients were ESVi responders (P = 0.001) 74.3% and 32.3% were NYHA responders (P = 0.002); similarly, 71.4% and 29.0% of patients exhibited a 2-year Packer score of 0 (P = 0.002). Conclusion: Patients with atypical RBBB, which is a pattern highly suggestive of concomitant delayed LV conduction, may show a satisfactory response to CRT.


Assuntos
Bloqueio de Ramo , Terapia de Ressincronização Cardíaca , Ecocardiografia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca , Ventrículos do Coração/fisiopatologia , Idoso , Bloqueio de Ramo/complicações , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Eletrocardiografia/métodos , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde
3.
Europace ; 18(3): 353-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26443444

RESUMO

AIMS: Right ventricular pacing adversely affects left atrial (LA) structure and function that may trigger atrial fibrillation (AF). This study compares the occurrence of persistent/permanent AF during long-term Hisian area (HA), right ventricular septal (RVS), and right ventricular apex (RVA) pacing in patients with complete/advanced atrioventricular block (AVB). METHODS AND RESULTS: We collected retrospective data from 477 consecutive patients who underwent pacemaker implantation for complete/advanced AVB. Ventricular pacing leads were located in the HA, RVS, and RVA in 148, 140, and 189 patients, respectively. The occurrence of persistent/permanent AF was observed in 114 (23.9%) patients (follow-up 58.5 ± 26.5 months). Hisian area groups presented a lower rate of AF occurrence (16.9%) compared with RVS and RVA groups (25.7 and 28.0%, respectively), P = 0.049. Cox's proportional hazard model was used to estimate HR. The risk of persistent/permanent AF was significantly lower in the patients paced from HA compared with those paced from RVA, HR = 0.28 (95% CI 0.16-0.48, P = 0.0001). The RVS and RVA pacing groups showed a similar AF risk: HR 1.04 (95% CI 0.66-1.64, P = 0.856). Other independent predictors of persistent/permanent AF occurrence included previous (before device implantation) paroxysmal AF (HR = 4.08; 95% CI 3.15-7.31, P = 0.0001), LA diameter, and age, whereas baseline bundle-branch block was associated with a lower risk of AF occurrence (HR = 0.56; 95% CI 0.35-0.81, P = 0.003). CONCLUSIONS: HA pacing compared with RVA or RVS pacing seems to be associated with a lower risk of persistent/permanent AF occurrence. The risk of persistent/permanent AF was similar in the RVA vs. RVS groups.


Assuntos
Fibrilação Atrial/etiologia , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Marca-Passo Artificial/efeitos adversos , Função Ventricular Direita , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/prevenção & controle , Função do Átrio Esquerdo , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/fisiopatologia , Fascículo Atrioventricular/fisiopatologia , Distribuição de Qui-Quadrado , Intervalo Livre de Doença , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Septo Interventricular/fisiopatologia
4.
Pacing Clin Electrophysiol ; 39(8): 830-6, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27119309

RESUMO

BACKGROUND: Based upon the results of a previous small pilot study, we present the results of a prospective single-center randomized study comparing the performance of the implantable loop recorder (ILR) at two implanting sites. METHODS: A group of patients whose ILRs were implanted via a left axillary approach were compared with a group who received an ILR in the traditional left site of the chest. Follow-up (FU) was scheduled every 6 months or when symptoms occurred. All patients enrolled in the study had a complete FU from implantation to explantation. R- and P-wave amplitudes were measured at implantation and during FU. Explantation of the device was programmed at the end of service life or when ILR analysis resulted in a complete and exhaustive diagnosis. RESULTS: Sixty-three patients were enrolled (70 ± 12 years, range: 21-92, 59% male): 31 standard and 32 with axillary access. The R-wave amplitude obtained with the new technique was comparable with that obtained with the standard procedure. The diagnostic accuracy of the ILR was comparable in the two groups. The axillary implantation procedure was slightly longer but no complications were observed. CONCLUSION: This long-term randomized study confirmed that axillary access for ILR implantation is feasible, safe, well tolerated, and reliable in terms of device performance. Moreover, it is aesthetically superior to the standard approach and carries the potential of minimizing permanent scarring after ILR extraction.


Assuntos
Fibrilação Atrial/diagnóstico , Axila/cirurgia , Eletrocardiografia Ambulatorial/instrumentação , Próteses e Implantes , Implantação de Prótese/métodos , Procedimentos Cirúrgicos Torácicos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Armazenamento e Recuperação da Informação/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento , Adulto Jovem
5.
Europace ; 16(7): 1033-9, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24473501

RESUMO

AIMS: Right ventricular apex (RVA) pacing has adverse effects on left atrial (LA) function and may contribute to atrial arrhythmias. The effects of Hisian area (HA) pacing on LA function are still lacking. The objective of this study is to assess the left ventricular (LV) electromechanical activation/relaxation, systolic (S), diastolic (D) phases, and their effects on LA function during pacing from HA and RVA. METHODS AND RESULTS: Thirty-seven patients with normal cardiac function underwent permanent HA pacing. In all patients, a RVA backup lead was added. The patients first underwent 3 months of HA pacing, followed by 3 months of RVA pacing. After each 3-month period, we compared by echocardiography: S-D LV electromechanical delay (S-D EMD), S-D intra-LV dyssynchrony, LV S-D phases, and their function evaluated by myocardial performance index (MPI) and mitral annular tissue Doppler early diastolic velocity (E'), pulmonary arterial systolic pressure (PASP), and LA function (LA phasic volumes and their emptying fraction). Right ventricular apex compared with HA pacing increased S-D EMD (P < 0.001) and intra-LV dyssynchrony (P < 0.001). As a consequence, a significant longer LV isovolumetric contraction time (P < 0.001) and LV isovolumetric relaxation time (P = 0.05) were measured during RVA compared with HA pacing, whereas LV ejection time was shorter (P = 0.033). Moreover, HA pacing resulted in significantly better MPI (P = 0.039), higher value of E' (P = 0.049), and lower PASP (P < 0.001). Finally, RVA compared with HA pacing was associated to higher LA volumes pre-atrial contraction (P = 0.001) and minimal volume (P = 0.003) with reduction in passive emptying fraction (P < 0.001) and total emptying fraction (P = 0.005). CONCLUSION: Hisian area compared with RVA pacing resulted in a more physiological LV electromechanical activation/relaxation and consequently better LA function.


Assuntos
Função do Átrio Esquerdo , Bloqueio Atrioventricular/terapia , Fascículo Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Ventrículos do Coração/fisiopatologia , Função Ventricular Esquerda , Função Ventricular Direita , Idoso , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Ecocardiografia Doppler em Cores , Ecocardiografia Doppler de Pulso , Eletrocardiografia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia
6.
J Electrocardiol ; 45(6): 723-6, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22698889

RESUMO

Atrial fibrillatory rate (AFR) can predict outcome of interventions for atrial fibrillation (AF); however, AFR behavior at AF onset in humans is poorly described. We studied AFR during spontaneous AF episodes in patients with lone paroxysmal AF who received implantable loop recorders and had AF episodes of 1 hour or more recorded (n = 4). Mean AFR per minute was assessed from continuous implantable loop recorder electrocardiogram using spatiotemporal QRST cancellation and time-frequency analysis. Atrial fibrillatory rate increased from 290 ± 20 to 326 ± 39 fibrillations per minute during the first 3 hours (P<.05) and reached plateau then. Atrial fibrillatory rate beyond the initial 3 hours can, therefore, be considered stable and may be evaluated for prediction of intervention effect.


Assuntos
Fibrilação Atrial/diagnóstico , Diagnóstico por Computador/métodos , Eletrocardiografia Ambulatorial/métodos , Feminino , Humanos , Armazenamento e Recuperação da Informação , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Medição de Risco , Sensibilidade e Especificidade
7.
Stroke ; 42(6): 1768-70, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21493904

RESUMO

BACKGROUND AND PURPOSE: In patients with atrial fibrillation (AF), stroke risk stratification schema do not consider AF parameters. The aim of the study is to assess the impact of combining risk factors with continuous AF burden monitoring. METHODS: In this retrospective study 568 patients implanted with a DDDR-P pacemaker (AT-500; Medtronic) and a history of AF were continuously monitored for 1 year. RESULTS: During follow-up, 14 patients (2.5%) had a thromboembolic event. Patients were divided into 3 groups: AF burden ≤5 minutes per day (AF-free; n=223 [39%]), AF burden >5 minutes but <24 hours per day (AF-5 minutes; n=179 [32%]), and AF burden ≥24 hours (AF-24 hours; n=166 [29%]). Patients were also classified according to CHADS2 and CHA2DS2-VASc risk scores. The discrimination ability of each risk score was evaluated performing a logistic regression analysis and calculating the corresponding C-statistic. The addition of AF burden improved C-statistics: for CHADS2 from 0.653 (P=0.051) to 0.713 (P=0.007); for CHA2DS2-VASc, from 0.898 (P<0.0001) to 0.910 (P<0.0001). CONCLUSIONS: The CHA2DS2-VASc score had a high sensitivity to predict thromboembolism. Implementation of device data on AF presence/duration/burden has the potential to contribute to improved clinical risk stratification and should be tested prospectively.


Assuntos
Arritmias Cardíacas/complicações , Fibrilação Atrial/complicações , Medição de Risco/métodos , Acidente Vascular Cerebral/etiologia , Idoso , Arritmias Cardíacas/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Estudos Retrospectivos , Fatores de Risco , Sensibilidade e Especificidade
8.
J Cardiovasc Electrophysiol ; 22(4): 369-75, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20958836

RESUMO

BACKGROUND: The aim of this prospective observational study was to identify responders to ablation through continuous subcutaneous monitoring for 1 year after ablation in patients with paroxysmal atrial fibrillation (PAF) or persistent AF (PersAF). METHOD: Patients with symptomatic drug refractory AF were enrolled. Real-time three-dimensional (3D) left atrium maps were reconstructed by using a nonfluoroscopic navigation system (CARTO, Biosense-Webster Inc., Diamond Bar, CA, USA). The ipsilateral left and right pulmonary veins (PVs) were encircled in 1 lesion line by circumferential PV isolation. All patients were implanted with Reveal XT (Medtronic Inc.) for continuous AF monitoring and data collected every month during the 12-month follow-up. RESULTS: We enrolled 129 patients (56 ± 9 years, 102 males), all of whom were followed-up for 12 months after the last ablation procedure: 58 (45%) had a history of PersAF. After only 1 ablation procedure, 76 (59%) of the 129 patients were AF-free at 12-month: 48 out of 71 (68%) in the PAF group and 28 out of 58 (48%) in the PersAF group. After 1 or more ablation procedures, 94 (73%) of the 129 patients were AF-free 12 months after the last procedure: 57 out of 71 (80%) in the PAF group and 37 out of 58 (64%) in the PersAF group. CONCLUSION: Ablation is highly effective in treating AF, as assessed through detailed 1-year continuous monitoring: success rate is higher in PAF than in PersAF patients. The use of subcutaneous monitors is a valuable means of identifying responders and nonresponders, and can potentially guide antiarrhythmic and antithrombotic therapies.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/instrumentação , Ablação por Cateter/métodos , Tela Subcutânea/fisiologia , Idoso , Fibrilação Atrial/diagnóstico , Mapeamento Potencial de Superfície Corporal/métodos , Eletrodos Implantados , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Estudos Prospectivos , Resultado do Tratamento
9.
Pacing Clin Electrophysiol ; 34(8): 954-62, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21453342

RESUMO

BACKGROUND: Detection of markers of incipient syncope in patients with vasovagal syncope (VVS), without prodromal symptom, is still an open issue. The aim of this study was to assess the behavior of heart rate (HR) and ejection time, expressed as the percentage of the corresponding cardiac cycle (ET%), in patients with bradycardic VVS with a view to providing an alarm before the event. METHODS: In 33 patients with syncope and positive tilt testing and in 33 control patients, we collected beat-to-beat data on HR, ET%, stroke volume (SV), and blood pressure (BP). The trends of HR and ET% were analyzed. A set of combined changes of HR and ET% were tested in order to select the most appropriate algorithm for detecting the incipient syncope within the 3 minutes preceding the event. RESULTS: In patients with positive tilt testing, BP significantly decreased at 3 minutes before and at the time of syncope (P < 0.0001). HR slowly rose at 3 minutes before syncope and then suddenly decreased at the time of syncope (P < 0.0001). The correlation between SV and ET% was r = 0.79 (P < 0.0001). SV and ET% significantly decreased throughout tilt testing (P < 0.0001). The selected setting for the algorithm provided sensitivity of 97% and specificity of 73%. The theoretical alarm was generated at least 9 and 5 seconds before syncope, respectively, in 76% and 85% of the subjects. CONCLUSION: The combined trends in HR and ET% may provide a marker of incipient bradycardic VVS in the majority of patients.


Assuntos
Bradicardia/diagnóstico , Hemodinâmica/fisiologia , Síncope Vasovagal/diagnóstico , Adolescente , Adulto , Idoso , Algoritmos , Biomarcadores , Pressão Sanguínea/fisiologia , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Sensibilidade e Especificidade , Volume Sistólico/fisiologia , Teste da Mesa Inclinada , Adulto Jovem
10.
Europace ; 12(6): 830-4, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20348144

RESUMO

AIMS: The evoked QT interval can be detected beat by beat through an implanted pacing system. The correlation between the right ventricular paced QT interval and the left ventricular systolic interval is not known. The aim of our study was to collect data on the correlation between QT and systolic and diastolic indexes at different heart rates in patients with dual-chamber rate-responsive pacemakers. METHOD AND RESULTS: The study involved 13 patients [67 +/- 9 years; ejection fraction (EF) 52 +/- 10%] with standard indication for dual-chamber pacing. Patients were evaluated at rest in the supine position. The AV delay was set at 130 ms, and the pacing rate was increased from 90 to 130 bpm (10 bpm steps for 3 min). At the end of each 3 min step, QT intervals were automatically evaluated in real time by means of pacemaker telemetry. We also evaluated heart performance by means of echo-2D (end-diastolic/end-systolic volumes, EF) and echo-Doppler measurements [left ventricular ejection time (LVET) and diastolic filling time (LVDFT), aortic velocity time integral, and systolic volume] and systemic arterial pressure. The QT interval progressively decreased from 330 +/- 20 to 280 +/- 10 ms as the pacing rate was increased from 90 to 130 bpm. The correlation between the QT interval and LVET as a function of the pacing rate was R(2) = 0.966, indicating a good and relatively parallel trend in these two parameters. The correlation between RR-QT (reflecting electrical diastole) and LVDFT (reflecting mechanical diastole) was R(2) = 0.975. The index LVET/QT (ratio between mechanical and electrical systole) was constant in the range 90-120 bpm, but significantly decreased at 130 bpm: the mechanical LVET shortens more than the electrical QT does at the highest heart rates. CONCLUSION: In paced patients at rest and during artificially increased heart rates, QT interval dynamics is closely correlated with changes in ejection time, thus constituting an electrical parameter of systolic time. A similar correlation exists between RR-QT, as a diastolic electrical interval, and the DFT.


Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial/métodos , Diástole/fisiologia , Eletrocardiografia , Frequência Cardíaca/fisiologia , Sístole/fisiologia , Potenciais de Ação/fisiologia , Idoso , Algoritmos , Aorta/fisiologia , Arritmias Cardíacas/fisiopatologia , Velocidade do Fluxo Sanguíneo/fisiologia , Ecocardiografia , Humanos , Pessoa de Meia-Idade , Volume Sistólico/fisiologia
11.
Pacing Clin Electrophysiol ; 33(5): 566-74, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20025705

RESUMO

BACKGROUND: The right ventricular septum (RVS) and Hisian area (HA) are considered more "physiological" pacing sites than right ventricular apex (RVA). Studies comparing RVS to RVA sites have produced controversial results. There are no data about variability of electromechanical activation obtained by an approach using fluoroscopy and electrophysiological markers. This study compared the variability of left ventricular (LV) electromechanical activation in patients undergoing short-term RVA and RVS with that measured during HA pacing based on fluoroscopy and electrophysiological markers. METHODS: Tissue Doppler echocardiography was performed in 142 patients before and after RVA (54), RVS (44), and HA (44) pacing. Electromechanical activation was assessed by: (1) electromechanical latency (EML)-interval between QRS onset and mechanical activation of basal LV; (2) intra-LV dyssynchrony (intra-LV)-interval between earliest to the latest LV basal motion. The intra- and interpatients variability among pacing groups were assessed. RESULTS: Pacing from RVA showed longer EML and higher degree of intra-LV than RVS and HA pacing. RVA and RVS showed a higher variability than HA pacing with regard to intrapatient changes of EML (RVA vs RVS, P = 0.4; RVS vs HA, P = 0.01, RVA vs HA, P = 0.0002) and intra-LV (RVA vs RVS, P = 0.2; RVS vs HA, P = 0.04; RVA vs HA, P = 0.005). Similar results were found in interpatients variability from paced-values. CONCLUSIONS: RVA and RVS pacing produce a variable effect on LV electromechanical activation that is significantly more pronounced than HA pacing. A pacing site such as HA selected by fluoroscopic and electrophysiological markers maintains baseline and homogeneous LV activation pattern.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Fascículo Atrioventricular/fisiologia , Estimulação Cardíaca Artificial , Função Ventricular , Septo Interventricular/fisiologia , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia Doppler de Pulso , Feminino , Fluoroscopia , Humanos , Masculino
12.
Pacing Clin Electrophysiol ; 33(8): 999-1002, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20487344

RESUMO

BACKGROUND: We compared the clinical course of 10 patients who received an implantable loop recorder (ILR) at a traditional site with 11 patients whose ILRs were implanted via a subpectoral site via a left axillary approach without complications. METHODS AND RESULTS: R-wave amplitude was determined at implantation and during follow-up. Each patient was followed after 7 days to optimize device setting and then at 1 and 3 months. The R-wave amplitude obtained with the new technique was significantly higher and more stable than that obtained with the standard procedure. Our preliminary experience suggests that axillary access for ILR implantation is feasible, safe, well tolerated, and reliable in terms of sensing function and device performance. Moreover, it is superior aesthetically to the standard approach and carries the potential of minimizing permanent scarring after ILR extraction.


Assuntos
Axila , Eletrocardiografia Ambulatorial , Eletrodos Implantados , Idoso , Eletrocardiografia , Eletrocardiografia Ambulatorial/instrumentação , Feminino , Humanos , Masculino , Síncope/etiologia , Síncope/fisiopatologia
13.
J Interv Card Electrophysiol ; 58(2): 147-156, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31807986

RESUMO

Non-left bundle branch block (non-LBBB) remains an uncertain indication for cardiac resynchronization therapy (CRT). Non-LBBB includes right bundle branch block (RBBB) and non-specific LV conduction delay (NSCD), two different electrocardiogram (ECG) patterns which are not generally considered to be associated with LV conduction delay as judged by the invasive assessment of the Q-LV interval. We evaluated whether a novel ECG interval (QR-max index) correlated with the degree of LV conduction delay regardless of the type of non-LBBB ECG pattern, and could, therefore, predict CRT response. In 173 non-LBBB patients on CRT (92 NSCD, 81 RBBB), the QR-max index was measured as the maximum interval from QRS onset to R-wave offset in the limb leads. The correlation between QR-max index and Q-LV interval and the impact of the QR-max index on time to first heart failure hospitalization during 3-year follow-up were assessed. Q-LV correlated better with the QR-max index than with QRSd, particularly in the RBBB group (r = 0.91; p < 0.001 vs. r = 0.19; p < 0.089), while the correlations were r = 0.79 (p < 0.01) and r = 0.68 (p < 0.01), respectively, in the NSCD group. In both groups, the QR-max index was significantly more able than QRSd to identify CRT responders (AUC 0.825 vs. 0.576; p = 0.0008 in RBBB; AUC 0.738 vs. 0.701; p = 0.459 in NSCD). A QR-max index exceeding a cutoff value of 120 ms was associated with CRT response, with predictive values of 86.8 and 81.4% in RBBB and NSCD, respectively. The QR-max index reflects the degree of LV electrical delay regardless of QRS duration in RBBB and NSCD patients and is a useful indicator of suitability for CRT in non-LBBB patients.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/terapia , Eletrocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Resultado do Tratamento
14.
J Cardiovasc Electrophysiol ; 20(3): 241-8, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19175849

RESUMO

INTRODUCTION: Asymptomatic atrial fibrillation (AF) can expose patients to the risk of stroke. The primary objective of this study was to assess the incidence of thromboembolic events in relationship with CHADS(2) (congestive heart failure, hypertension, age >or=75 years, diabetes mellitus, and prior stroke, or transient ischemic attack) score and AF presence/duration. The secondary objective was to compare intermittent versus continuous monitoring strategies. METHODS AND RESULTS: Data from patients with an implanted pacemaker and a history of AF were analyzed. Thromboembolic risk was quantified through CHADS(2) score. Three AF groups were considered: patients with <5-minutes AF on 1 day (AF-free); patients with >5-minutes AF on 1 day but <24 hours (AF-5 minutes); patients with AF episodes >24 hours (AF-24 hours). Monitoring strategies involving 24-hour Holter, 1-week Holter, and 30-day Holter were simulated. Data from 568 patients continuously monitored for 1 year were analyzed: 171 (30%) had CHADS(2) score = 0; 269 (47%) had CHADS(2) score = 1; 111 (20%) had CHADS(2) score = 2; and 17 (3%) had CHADS(2) score >or= 3. During follow-up, 14 patients (2.5%) had an ischemic thromboembolic event. AF-24 hours patients numbered 223 (39.2%); AF-5 minutes, 179 (31.5%); and AF-free, 29.2%. By combining AF presence/duration with CHADS(2) score, two subpopulations with markedly different risks of events (0.8% vs 5%, P = 0.035) were identified, the former corresponding to AF-free with CHADS(2)5 minutes was 44.4%, 50.4%, and 65.1% for 24-hour Holter, 1-week Holter, and 1-month Holter monitoring, respectively. CONCLUSION: In patients with recurrent AF episodes, risk stratification for thromboembolic events can be improved by combining CHADS(2) score with AF presence/duration.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Eletrocardiografia Ambulatorial/métodos , Medição de Risco/métodos , Tromboembolia/diagnóstico , Tromboembolia/epidemiologia , Idoso , Comorbidade , Feminino , Humanos , Incidência , Itália/epidemiologia , Masculino , Prognóstico , Fatores de Risco
15.
Pacing Clin Electrophysiol ; 32(1): 91-8, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19140918

RESUMO

BACKGROUND: Atrial fibrillation (AF) is not always accompanied by clear-cut symptoms and symptoms suggestive of AF may not correspond to a genuine AF episode. The study prospectively evaluated the burden of asymptomatic AF episodes in pacemaker patients (for sick sinus syndrome) with a history of documented paroxysmal AF. METHODS: Consecutive patients were enrolled and implanted with dual-chamber pacemakers equipped with diagnostic features for AF monitoring. Each patient was instructed about typical AF symptoms and was asked to keep a detailed log of symptoms. Stored pacemaker data were analyzed using only AF episodes >30 s. RESULTS: The mean follow-up was 16 +/- 6 months and 102 patients were enrolled (73 +/- 7 years, 59 M). Thirteen patients (13%) dropped out with the development of permanent AF and their data were discarded. Twenty-three patients (26%) without device-stored AF episodes all reported at least one annotated AF episode. There were 1,245 device-stored AF episodes in 66 (74%) out of 89 patients. Patients reported 1,141 episodes of AF-related symptoms. Only 240 (21%) corresponded to a genuine device-stored AF event. The sensitivity and positive predictive value of symptoms to detect AF were respectively 19% and 21%. Episode duration, rate increase at the onset of the arrhythmia, heart disease, or antiarrhythmic drug therapy showed no statistically significant differences comparing symptomatic and asymptomatic episodes. CONCLUSIONS: Many pacemaker patients with paroxysmal AF can develop AF-like symptoms in the absence of device-stored AF. AF-related symptoms have low sensitivity and low positive predictive value in patients with permanent pacemakers.


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/prevenção & controle , Eletrocardiografia/estatística & dados numéricos , Marca-Passo Artificial/estatística & dados numéricos , Medição de Risco/métodos , Idoso , Fibrilação Atrial/diagnóstico , Feminino , Humanos , Incidência , Itália/epidemiologia , Masculino , Fatores de Risco
16.
Eur J Echocardiogr ; 10(1): 106-11, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18579495

RESUMO

OBJECTIVE: To evaluate the effects of cardiac resynchronization therapy (CRT) on ventricular-arterial coupling (VAC) in patients with refractory congestive heart failure (HF), left bundle brunch block, and sinus rhythm. BACKGROUND: The ratio between arterial elastance (Ea) and left ventricular end-systolic elastance (Ees), the so-called VAC, defines the efficiency of the myocardium in pumping blood. METHODS: Seventy-eight patients were studied with echocardiography before CRT, and 1 year later. End-systolic elastance was calculated according to the method of Chen. Arterial elastance (ratio of the systolic pressure to the stroke volume), end-systolic volume (ESV), and quality of life (QoL) (Minnesota Living with Heart Failure Questionnaire) were assessed at the baseline and after 1 year. Patients with a reduction>15% of ESV or a decrease>33% in QoL score were considered responders to CRT. RESULTS: QRS duration and interventricular delay were significantly reduced with CRT compared with baseline (156+/-2 vs. 195+/-3 ms, P<0.001; and 25+/-2 vs. 55+/-3 ms, P<0.001, respectively). Arterial elastance/Ees decreased significantly on CRT (2.47+/-1.48 vs. 1.41+/-0.87, P<0.0001). The lowering of Ea/Ees was congruent to a decrease in intraventricular delay (83.1+/-55.7 vs. 28.4+/-49.5 ms, P<0.0001) and an increase in ejection fraction (26+/-6.3 vs. 36.9+/-8.0%, P<0.0001). Responders to CRT were 74 and 71% of the overall patient population, considering as endpoint QoL or ESV, respectively. The analysis of VAC showed a baseline cut-off value of 2, above which 88% and 69% of patients responded to CRT, considering as endpoint QoL or ESV, respectively. CONCLUSIONS: The non-invasive assessment of VAC may be proposed as an immediate, easy, and optimal tool for quantifying the effect of CRT in patients with HF.


Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial/métodos , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Estudos de Coortes , Ecocardiografia Doppler , Eletrocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/terapia , Valor Preditivo dos Testes , Medição de Risco , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/terapia , Remodelação Ventricular
17.
Europace ; 10(5): 580-7, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18407969

RESUMO

AIMS: The His bundle is regarded as the most physiological site for ventricular pacing, in that it avoids the adverse effects of right ventricular apical pacing (RVAP). However, very few studies have compared the effects of direct His bundle pacing (DHBP) and RVAP. The aim of our study was the intra-patient comparison of myocardial perfusion corresponding to these two different pacing techniques, as perfusion expresses local workload and is related to long-term outcome. METHODS AND RESULTS: Twelve consecutive patients with standard pacemaker indication (9 male, 74 +/- 9 years) entered the study. Pacing leads were implanted in the right ventricular apex and directly in the His bundle, and were connected to different ports of the pacemaker. All patients first underwent 3 months of DHBP, followed by 3 months of RVAP. At the end of each 3-month period, myocardial perfusion was measured at rest using scintigraphy with Tc99m-SestaMIBI. The average values of perfusion were evaluated on a 20-segment basis. All patients also underwent clinical evaluation, echocardiography, and tissue Doppler imaging (TDI), to measure dyssynchrony, and a blood sample was taken for brain natriuretic peptide (BNP) assay. The perfusion score during DHBP pacing was significantly better than during RVAP (0.44 +/- 0.5 vs. 0.71 +/- 0.53, respectively; P = 0.011). None of the patients showed lower perfusion during DHBP than during RVAP. We found no significant difference in NYHA class, ventricular volumes, ejection fraction, or plasmatic BNP between DHBP and RVAP. However, mitral regurgitation (0.26 +/- 0.21 vs. 0.37 +/- 0.25; P < 0.001) and dyssynchrony (13.75 +/- 4.28 vs. 22.02 +/- 8.44; P = 0.008) were significantly less during DHBP than during RVAP. CONCLUSION: Direct His bundle pacing is superior to RVAP in preserving the physiologic distribution of myocardial blood flow and reducing mitral regurgitation and left ventricular dyssynchrony.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial/métodos , Circulação Coronária , Ventrículos do Coração , Taquicardia Ventricular/prevenção & controle , Idoso , Estudos Cross-Over , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento
18.
Cardiovasc Ultrasound ; 6: 1, 2008 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-18167164

RESUMO

BACKGROUND: Electrical fusion between left ventricular pacing and spontaneous right ventricular activation is considered the key to resynchronisation in sinus rhythm patients treated with single-site left ventricular pacing. AIM: Use of QRS morphology to optimize device programming in patients with heart failure (HF), sinus rhythm (SR), left bundle branch block (LBBB), treated with single-site left ventricular pacing. METHODS AND RESULTS: We defined the "fusion band" (FB) as the range of AV intervals within which surface ECG showed an intermediate morphology between the native LBBB and the fully paced right bundle branch block patterns.Twenty-four patients were enrolled. Echo-derived parameters were collected in the FB and compared with the basal LBBB condition. Velocity time integral and ejection time did not improve significantly. Diastolic filling time, ejection fraction and myocardial performance index showed a statistically significant improvement in the FB. Interventricular delay and mitral regurgitation progressively and significantly decreased as AV delay shortened in the FB. The tissue Doppler asynchrony index (Ts-SD-12-ejection) showed a non significant decreasing trend in the FB. The indications provided by the tested parameters were mostly concordant in that part of the FB corresponding to the shortest AV intervals. CONCLUSION: Using ECG criteria based on the FB may constitute an attractive option for a safe, simple and rapid optimization of resynchronization therapy in patients with HF, SR and LBBB.


Assuntos
Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Idoso , Bloqueio de Ramo/diagnóstico por imagem , Ecocardiografia Doppler , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Volume Sistólico/fisiologia , Resultado do Tratamento
19.
J Interv Card Electrophysiol ; 15(2): 107-11, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16755339

RESUMO

UNLABELLED: Theoretically, replacement of a VDD device requires using a similar pacemaker to provide the best match between the filtering characteristics of the pacemaker and the atrial dipole of the lead. This study evaluated the performance of newly implanted Vitatron VDD pacemakers connected to dedicated leads and compared the results with those of the same Vitatron pacemakers used as replacement but connected to a variety of nondedicated leads. METHODS: 23 consecutive patients (15 M, 8 F, 78 +/- 6 years) in Group 1 underwent pacemaker replacement with a VDD(R) Saphir 3 (Vitatron BV, Arnhem, The Netherlands) device designed for an 8.6 mm atrial dipole. Atrial dipoles of the previously implanted leads ranged from 5 to 30 mm. Another 22 consecutive patients (14 M, 8 F, 80 +/- 7 years) in Group 2 received a Saphir 3 pacemaker with the related dedicated lead. RESULTS: P-wave amplitude measured by the same Pacing Sensing Analyzer (PSA) at the first implantation was 1.7 +/- 0.8 vs. 1.7 +/- 0.5 mV (P = NS) in groups 1 and 2 respectively. P-wave amplitudes measured at 1 month follow-up after replacement in Group 1 and at 1 month follow-up after implantation in Group 2 were 0.69 +/- 0.5 vs. 0.85 +/- 0.3 mV (P = NS) respectively. The percentage of atrial sensing at the same follow-up was 97 +/- 3 vs. 95 +/- 5% (P = NS) in groups 1 and 2 respectively. CONCLUSIONS: Replacement of VDD pacemakers with the Saphir 3 model designed for a short dipole is safe and reliable when used in combination with previously implanted nondedicated leads.


Assuntos
Bloqueio Cardíaco/terapia , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo , Eletrodos Implantados , Desenho de Equipamento , Falha de Equipamento , Feminino , Humanos , Masculino , Estudos Prospectivos , Telemetria
20.
Heart Rhythm ; 13(12): 2289-2296, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27424074

RESUMO

BACKGROUND: Estimating left ventricular electrical delay (Q-LV) from a 12-lead ECG may be important in evaluating cardiac resynchronization therapy (CRT). OBJECTIVE: The purpose of this study was to assess the impact of Q-LV interval on ECG configuration. METHODS: One hundred ninety-two consecutive patients undergoing CRT implantation were divided electrocardiographically into 3 groups: left bundle branch block (LBBB), right bundle branch block (RBBB), and nonspecific intraventricular conduction delay (IVCD). The IVCD group was further subdivided into 81 patients with left (L)-IVCD and 15 patients with right (R)-IVCD (resembling RBBB, but without S wave in leads I and aVL). The Q-LV interval in the different groups and the relationship between ECG parameters and the maximum Q-LV interval were analyzed. RESULTS: Patients with LBBB presented a long Q-LV interval (147.7 ± 14.6 ms, all exceeding cutoff value of 110 ms), whereas RBBB patients presented a very short Q-LV interval (75.2 ± 16.3 ms, all <110 ms). Patients with an IVCD displayed a wide range of Q-LV intervals. In L-IVCD, mid-QRS notching/slurring showed the strongest correlation with a longer Q-LV interval, followed, in decreasing order, by QRS duration >150 ms and intrinsicoid deflection >60 ms. Isolated mid-QRS notching/slurring predicted Q-LV interval >110 ms in 68% of patients. The R-IVCD group presented an unexpectedly longer Q-LV interval (127.0 ± 12.5 ms; 13/15 patients had Q-LV >110 ms). CONCLUSION: Patients with LBBB have a very prolonged Q-LV interval. Mid-QRS notching in lateral leads strongly predicts a longer Q-LV interval in L-IVCD patients. Patients with R-IVCD constitute a subgroup of patients with a long Q-LV interval.


Assuntos
Bloqueio de Ramo , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco , Idoso , Idoso de 80 Anos ou mais , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Feminino , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Estatística como Assunto , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA