Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Medicina (Kaunas) ; 59(1)2023 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-36676792

RESUMO

Objectives: The present study compared two implants with different macrogeometries placed in healed alveolar sites, evaluating the insertion torque (ITV) and implant stability quotient (ISQ) values at three different periods. Methods: Seventy patients with a total of 100 dental implants were allocated into two groups (n = 50 per group): DuoCone implants (DC group) that included 28 implants in the maxilla and 22 in the mandible, and Maestro implants (MAE group) that included 26 in the maxilla and 24 in the mandible. The ITV was measured during the implant placement, and the ISQ values were measured immediately at implant placement (baseline) and after 30 and 45 days. Results: The mean and standard deviations of the ITV were statistically significant (p < 0.0001), 56.4 ± 6.41 Ncm for the DC group and 29.3 ± 9.65 Ncm for the MAE group. In the DC group, the ISQs ranged between 61.1 ± 3.78 and 69.8 ± 3.86, while the MAE group presented similar values compared with the other group, ranging between 61.9 ± 3.92 and 72.1 ± 2.37. Conclusions: The value of implant insertion torque did not influence the ISQ values measured immediately after implant placement. However, the ITV influenced the ISQ values measured in the two initial periods of osseointegration, with implants installed with lower torques presenting higher ISQ values.


Assuntos
Maxila , Osseointegração , Humanos , Torque , Maxila/cirurgia , Mandíbula , Coleta de Dados
2.
Medicina (Kaunas) ; 59(7)2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37512062

RESUMO

Objective: The primary objective of the present retrospective clinical study was to evaluate and compare the clinical performance presented by castable abutments developed for the MT system versus intermediate machined abutments, specifically regarding prosthetic or implant fractures/loss; the secondary objective was to verify the looseness of the abutments and the behavior of the peri-implant soft tissues. Methods: This clinical retrospective study was conducted on patients rehabilitated between 2019 and 2020. Inclusion criteria were patients in good general health, with an implants-supporting single crown; with solid machined abutments (control group) or castable UCLA abutments; with a connection portion (base) machined in cobalt-chrome (test group) over Morse taper DuoCone implants in the posterior mandible area; and at least two years in function. Clinical assessment was carried out by the same professional, considering the following parameters: (A) prosthetic: (i) loosening of the fixation screw, (ii) fracture of the screw and (iii) the number of times the patient had some type of complication after the installation of the prostheses were evaluated; (B) biological: (i) without keratinized mucosa (KM), (ii) 1 mm or less, (iii) between 1 and 2 mm and (iv) greater than 2 mm of KM width; and the presence or absence of mucositis. Furthermore, radiographic evaluation was performed in order to assess the marginal bone loss. These evaluations permitted to compare the groups analyzed and patients enrolled. Data were statistically analyzed, with the level of significance set at α = 0.05. Results: 79 patients with 120 MT implants were evaluated (80 castable UCLA abutments and 40 machined solid abutments). The follow-up was from 2 to 4 years. There was a 100% implant survival rate. Therefore, the control group showed two fractured abutments (5%) and no abutment loosening (95% for prosthetic survival rate), whereas the test group showed no abutment fracture but nine loosening screws (11.3%) (100% for prosthetic survival rate). Keratinized mucosa was considered thin or absent in 19 implants in the control group (47.5%) and 42 in the test group (52.5%). Mucositis was found in 11 implants in the control group (27.5%) and 27 in the test group (33.8%). A positive correlation was observed between the width of keratinized mucosa and mucositis (r = 0.521, p = 0.002). The mean marginal bone loss was 2.3 mm, ranging from 1.1 to 5.8 mm. No correlation was observed when considering marginal bone loss versus the three parameters (implant diameter, implant length and time of the prosthesis in function). Conclusions: The results suggest that UCLA-type abutments are a viable option for rehabilitating implants with Morse taper connections, suggesting lower fracture risk. Further research is necessary to confirm these findings and thoroughly evaluate the clinical performance and long-term outcomes.


Assuntos
Mucosite , Humanos , Estudos Retrospectivos , Próteses e Implantes
3.
J Funct Biomater ; 15(7)2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-39057299

RESUMO

The present study evaluated the mechanical behavior of five designs of Morse taper (MT) connections with and without the application of loads. For this, the detorque of the fixing screw and the traction force required to disconnect the abutment from the implant were assessed. A total of 100 sets of implants/abutments (IAs) with MT-type connections were used, comprising five groups (n = 20/group): (1) Group Imp 11.5: IA sets with a cone angulation of 11.5°; (2) Group SIN 11.5: with a cone angulation of 11.5°; (3) Group SIN 16: with a cone angulation of 16°; (4) Group Neo 16: with a cone angulation of 16°; and (5) Group Str 15: with a cone angulation of 15°. All sets received the torque recommended by the manufacturer. After applying the torque, the counter torque of the fixing screws was measured in ten IA sets of each group without the application of cyclic loads (frequencies ≤ 2 Hz, 360,000 cycles, and force at 150 Ncm). The other ten sets of each group were subjected to cyclic loads, after which the detorque was measured. Afterwards, the force for disconnection between the implant and the abutment was measured by traction on all the samples. The untwisting of the abutment fixation screws showed a decrease in relation to the initial torque applied in all groups. In the unloaded samples, it was found to be -25.7% in Group 1, -30.4% in Group 2, -36.8% in Group 3, -29.6% in Group 4, and -25.7% in Group 5. After the applied loads, it was found to be -44% in Group 1, -43.5% in Group 2, -48.5% in Group 3, -47.2% in Group 4, and -49.8% in Group 5. The values for the IA sets were zero for SIN 16 (Group 3) and Neo16 (Group 4), both without and with loads. In the other three groups, without loads, the disconnection value was 56.3 ± 2.21 N (Group 1), 30.7 ± 2.00 N (Group 2), and 26.0 ± 2.52 N (Group 5). After applying loads, the values were 63.5 ± 3.06 N for Group 1, 34.2 ± 2.45 N in Group 2, and 23.1 ± 1.29 N in Group 5. It was concluded that in terms of the mechanical behavior of the five designs of MT IA sets, with and without the application of loads, the Imp 11.5, SIN 11.5, and Srt 15 groups showed better results compared to the SIN 16 and Neo 16 groups, showing that lower values of cone angulation increase the friction between the parts (IA), thus avoiding the need to maintain the torque of the fixing screw to maintain the union of the sets.

4.
PLoS One ; 19(3): e0298462, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38457413

RESUMO

The present study compared three different implant and abutment sets of type Morse taper (MT) connection, with- and without-index, were analyzed regarding their mechanical behavior without and with cyclic load application simulating the masticatory function. Ninety implant and abutment (IA) sets were used in the present study, divided into three groups (n = 30 samples per group): Group A, Ideale solid straight abutment (one piece) without index; Group B, Ideale abutment with an angle of 30-degree (two pieces) without index; Group C, Ideale abutment with an angle of 30-degree (two pieces) with index. The abutment stability quotient (ASQ) values, detorque value and rotation angle were measured before and after the cycling load. Twenty IA sets of each group were submitted to mechanical load at 360,000 cycles. The ASQ without load were 64.7 ± 2.49 for the group A, 60.2 ± 2.64 for the group B, 54.4 ± 3.27 for the group C; With load were 66.1 ± 5.20 for the group A, 58.5 ± 6.14 for the group B, 58.9 ± 2.99 for the group C. Detorque values were lower in groups B and C compared to group A (p < 0.05). In conclusion, the presence of the index did not influence the stability values. However, solid straight abutments (group A) showed higher values of stability compared to groups of angled abutments (groups B and C).

5.
J Funct Biomater ; 14(3)2023 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-36976052

RESUMO

The goal of this retrospective clinical study was to evaluate the behavior of Morse-taper indexed abutments by analyzing the marginal bone level (MBL) after at least 12 months of function. Patients rehabilitated with single ceramic crowns between May 2015 and December 2020 received single Morse-taper connection implants (DuoCone implant) with two-piece straight abutment baseT used for at least 12 months, presenting periapical radiograph immediately after crown installation were enrolled. The position of the rehabilitated tooth and arch (maxilla or mandible), crown installation period, implant dimensions, abutment transmucosal height, installation site (immediate implant placement or healed area), associated with bone regeneration, immediate provisionalization, and complications after installation of the final crown were analyzed. The initial and final MBL was evaluated by comparing the initial and final X-rays. The level of significance was α = 0.05. Seventy-five patients (49 women and 26 men) enrolled had a mean period of evaluation of 22.7 ± 6.2 months. Thirty-one implant-abutment (IA) sets had between 12-18 months, 34 between 19-24 months, and 44 between 25-33 months. Only one patient failed due to an abutment fracture after 25 months of function. Fifty-eight implants were placed in the maxilla (53.2%) and 51 in the mandible (46.8%). Seventy-four implants were installed in healed sites (67.9%), and 35 were in fresh socket sites (32.1%). Thirty-two out of these 35 implants placed in fresh sockets had the gap filled with bone graft particles. Twenty-six implants received immediate provisionalization. The average MBL was -0.67 ± 0.65 mm in mesial and -0.70 ± 0.63 mm in distal (p = 0.5072). The most important finding was the statistically significant difference comparing the values obtained for MBL between the abutments with different transmucosal height portions, which were better for abutments with heights greater than 2.5 mm. Regarding the abutments' diameter, 58 had 3.5 mm (53.2%) and 51 had 4.5 mm (46.8%). There was no statistical difference between them, with the following means and standard deviation, respectively, -0.57 ± 0.53 mm (mesial) and -0.66 ± 0.50 mm (distal), and -0.78 ± 0.75 mm (mesial) and -0.746 ± 0.76 mm (distal). Regarding the implant dimensions, 24 implants were 3.5 mm (22%), and 85 implants (78%) had 4.0 mm. In length, 51 implants had 9 mm (46.8%), 25 had 11 mm (22.9%), and 33 implants were 13 mm (30.3%). There was no statistical difference between the abutment diameters (p > 0.05). Within the limitations of this study, it was possible to conclude that better behavior and lesser marginal bone loss were observed when using abutment heights greater than 2.5 mm of transmucosal portion and when placed implants with 13 mm length. Furthermore, this type of abutment showed a little incidence of failures within the period analyzed in our study.

6.
Heliyon ; 9(4): e15312, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37151670

RESUMO

Objectives: Micromotion between a dental implant and abutment can adversely affect clinical performance and compromise successful osseointegration by creating a bacterial harbor, enabling screw loosening, and imparting disruptive lateral forces on the cortical bone. Thus, the aim of the present study was to measure the abutment stability evolution using resonance frequency analysis (RFA) in vivo at four different times (baseline, 3, 4, and 12 months), and compare these data obtained with the RFA measured after mechanical cycling (in vitro) corresponding to the proposed times in numbers of cycles. Methods: To evaluate the abutment stability, RFA was performed in 70 sets of implant/abutment (IA) with a total of 54 patients (31 women, 23 men). These IA sets were divided into three groups, according to the abutment angulation: straight abutment (Abt1 group), 17-degree angled abutment (Abt2 group), and 30-degree angled abutment (Abt3 group). Abutment stability was measured immediately at implant placement and the abutment installation (T1), 3 (T2), 4 (T3), and 12 months (T4) later. For the in vitro analysis, ten sets of each group were submitted to mechanical cycling: T1 = 0 cycles, T2 = 90,000 cycles, T3 = 120,000 cycles, and T4 = 360,000 cycles. All data collected were statistically evaluated using the GraphPad Prism 5.01 software, with the level of significance was α = 0.05. Results: In vivo, the overall data of implant stability quotient (ISQ) values obtained for all groups in each evaluation time were 61.5 ± 3.94 (95% CI: [60-63]) at T1, 62.8 ± 3.73 (95% CI, [61-64]) at T2, 63.4 ± 3.08 (95% CI: [61-64]) at T3, and 65.5 ± 4.33 (95% CI: [63-68]) at T4. Whereas in vitro, the ISQ were 61.5 ± 2.66 (95% CI: [59-63]) at T1, 63.2 ± 3.02 (95% CI, [61-65]) at T2, 63.9 ± 2.55 (95% CI: [62-66]) at T3, and 66.5 ± 2.97 (95% CI: [64-68]) at T4. In both evaluations (in vivo and in vitro), the data showed a significant difference (ANOVA test with p < 0.0001). Conclusions: The RFA to measure the abutment stability used in this study showed that there was a progressive increase in stability among the predetermined times for the measurements, in both analysis (in vivo and in vitro). Furthermore, the values at each time point were similar, with no statistical difference between them.

7.
Int J Oral Maxillofac Implants ; 34(2): 337-342, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30883616

RESUMO

PURPOSE: This study investigated the effect of fracture strength and fracture mode characteristics related to reduced interocclusal space on computer-aided design/computer-aided manufacturing (CAD/CAM). ZrO2 fixed partial denture (FPD) frameworks subjected to quasi-static loads. MATERIALS AND METHODS: First, two dental implants (4 × 10 mm) were positioned simulating a three-unit FPD (second premolar and second molar abutments). The implants were distributed into two groups: control group (n = 10), positioned at the same level; and the test group (n = 10), where the interocclusal space corresponding to the second molar was reduced by 3 mm in relation to the second premolar to simulate a clinical situation. After FPD wax-up (25-mm long; connector height = 5 mm; connector width = 3 mm, proximal and lingual collar reinforcement), casting was made in a Co-Cr alloy to serve as a prototype. Upon scanning, screw-retained CAD/CAM ZrO2 FPDs were fabricated for each group. Then, FPDs were subjected to quasi-static axial loading until fracture in the mid-occlusal pontic area using a universal testing machine at the crosshead speed of 0.5 mm/min. Next, the samples were analyzed by scanning electronic microscopy (SEM) to describe the fracture characteristics. RESULTS: The mean fracture strength values for the control group (1,747.4 ± 122.3 N) and test group (1,817.7 ± 158.9 N) showed no significant difference (Student t test, P < .124). The SEM images of the fracture sites revealed two cleavage areas in the test group, providing representative sites with increased fracture energy storage in this group compared with the control group. CONCLUSION: Within the limitations of this study, the results showed that reduced interocclusal space and reduced length did not decrease the fracture strength of the ZrO2 FPD frameworks.


Assuntos
Dente Suporte , Implantes Dentários , Prótese Parcial Fixa , Zircônio , Desenho Assistido por Computador , Análise do Estresse Dentário , Humanos , Teste de Materiais , Microscopia de Força Atômica , Projetos Piloto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA