Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
NMR Biomed ; 31(9): e3991, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30040156

RESUMO

INTRODUCTION: The composition of fatty acids in the body is gaining increasing interest, and can be followed up noninvasively by quantitative magnetic resonance spectroscopy (MRS). However, current MRS quantification methods have been shown to provide different quantitative results in terms of lipid signals, with possible varying outcomes for a given biological examination. Quantitative magnetic resonance imaging using multigradient echo sequence (MGE-MRI) has recently been added to MRS approaches. In contrast, these methods fit the undersampled magnetic resonance temporal signal with a simplified model function (expressing the triglyceride [TG] spectrum with only three TG parameters), specific implementations and prior knowledge. In this study, an adaptation of an MGE-MRI method to MRS lipid quantification is proposed. METHODS: Several versions of the method - with time data fully or undersampled, including or excluding the spectral peak T2 knowledge in the fitting - were compared theoretically and on Monte Carlo studies with a time-domain, peak-fitting approach. Robustness, repeatability and accuracy were also inspected on in vitro oil acquisitions and test-retest in vivo subcutaneous adipose tissue acquisitions, adding results from the reference LCModel method. RESULTS: On simulations, the proposed method provided TG parameter estimates with the smallest variability, but with a possible bias, which was mitigated by fitting on undersampled data and considering peak T2 values. For in vitro measurements, estimates for all approaches were correlated with theoretical values and the best concordance was found for the usual MRS method (LCModel and peak fitting). Limited in vivo test-retest variability was found (4.1% for PUFAindx, 0.6% for MUFAindx and 3.6% for SFAindx), as for LCModel (7.6% for PUFAindx, 7.8% for MUFAindx and 3.0% for SFAindx). CONCLUSION: This study shows that fitting the three TG parameters directly on MRS data is one valuable solution to circumvent the poor conditioning of the MRS quantification problem.


Assuntos
Ácidos Graxos/análise , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Processamento de Sinais Assistido por Computador , Tecido Adiposo/metabolismo , Adulto , Simulação por Computador , Humanos , Masculino , Método de Monte Carlo
2.
MAGMA ; 29(1): 1-4, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26724927

RESUMO

OBJECTIVE: To evaluate the feasibility of in vivo measurement of the fatty acid (FA) composition of breast adipose tissue by MRS on a clinical platform. MATERIAL AND METHODS: MRS experiments were performed at 3 T, using a STEAM sequence, on 25 patients diagnosed with breast cancer. MR spectra, acquired on healthy breast tissue, were analysed with the LCModel. RESULTS: The measured values of the saturated fatty acid (SFA), mono-unsaturated fatty acid (MUFA) and poly-unsaturated fatty acid (PUFA) fractions were 23.8 ± 7.1%, 55.4 ± 6.8% and 20.8 ± 4.4%, respectively. The values of SFA, MUFA and PUFA observed in the current study are in the same range as those found in two previous studies performed at 7 T. CONCLUSION: The results of the current study show that it is possible to quantify the fatty acid composition of breast tissue in vivo in a clinical setting (3 T).


Assuntos
Mama/diagnóstico por imagem , Ácidos Graxos/química , Espectroscopia de Ressonância Magnética , Tecido Adiposo/química , Idoso , Biomarcadores Tumorais/química , Mama/química , Mama/patologia , Ácidos Graxos Monoinsaturados/química , Ácidos Graxos Insaturados/química , Feminino , Humanos , Pessoa de Meia-Idade , Software
3.
MAGMA ; 29(1): 29-37, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26590825

RESUMO

OBJECTIVE: To investigate the effect of water suppression on the hepatic lipid quantification, using the LCModel. MATERIALS AND METHODS: MR spectra with and without water suppression were acquired in the liver of mice at 4.7 T and patients at 3 T, and processed with the LCModel. The Cramér-Rao Lower Bound (CRLB) values of the seven lipid resonances were determined to assess the impact of water suppression on hepatic lipid quantification. A paired t test was used for comparison between the CRLBs obtained with and without water suppression. RESULTS: For the preclinical data, in the high (low) fat fraction subset an overall impairment in hepatic lipid quantification, i.e. an increase of CRLBs (no significant change of CRLBs) was observed in spectra acquired with water suppression. For the clinical data, there were no substantial changes in the CRLB with water suppression. Because (1) the water suppression does not overall improve the quantification of the lipid resonances and (2) the MR spectrum without water suppression is always acquired for fat fraction calculation, the optimal data-acquisition strategy for liver MRS is to acquire only the MR spectrum without water suppression. CONCLUSION: For quantification of hepatic lipid resonances, it is advantageous to perform MR spectroscopy without water suppression in a clinical and preclinical scenario (at moderate fields).


Assuntos
Lipídeos/química , Fígado/diagnóstico por imagem , Espectroscopia de Ressonância Magnética/métodos , Água/química , Animais , Biomarcadores/química , Diagnóstico por Imagem/métodos , Fígado Gorduroso/diagnóstico por imagem , Feminino , Fígado/química , Camundongos , Camundongos Endogâmicos C57BL
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA