Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Bioinformatics ; 33(11): 1744-1746, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28158427

RESUMO

SUMMARY: We introduce an open-source software, LIQUID, for semi-automated processing and visualization of LC-MS/MS-based lipidomics data. LIQUID provides users with the capability to process high throughput data and contains a customizable target library and scoring model per project needs. The graphical user interface provides visualization of multiple lines of spectral evidence for each lipid identification, allowing rapid examination of data for making confident identifications of lipid molecular species. LIQUID was compared to other freely available software commonly used to identify lipids and other small molecules (e.g. CFM-ID, MetFrag, GNPS, LipidBlast and MS-DIAL), and was found to have a faster processing time to arrive at a higher number of validated lipid identifications. AVAILABILITY AND IMPLEMENTATION: LIQUID is available at http://github.com/PNNL-Comp-Mass-Spec/LIQUID . CONTACT: jennifer.kyle@pnnl.gov or thomas.metz@pnnl.gov. SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.


Assuntos
Cromatografia Líquida/métodos , Lipídeos/análise , Software , Espectrometria de Massas em Tandem/métodos , Plantas/química , Plantas/metabolismo , Leveduras/química , Leveduras/metabolismo
2.
Int J Mass Spectrom ; 427: 91-99, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29706793

RESUMO

The mass accuracy and peak intensity of ions detected by mass spectrometry (MS) measurements are essential to facilitate compound identification and quantitation. However, high concentration species can yield erroneous results if their ion intensities reach beyond the limits of the detection system, leading to distorted and non-ideal detector response (e.g. saturation), and largely precluding the calculation of accurate m/z and intensity values. Here we present an open source computational method to correct peaks above a defined intensity (saturated) threshold determined by the MS instrumentation such as the analog-to-digital converters or time-to-digital converters used in conjunction with time-of-flight MS. In this method, the isotopic envelope for each observed ion above the saturation threshold is compared to its expected theoretical isotopic distribution. The most intense isotopic peak for which saturation does not occur is then utilized to re-calculate the precursor m/z and correct the intensity, resulting in both higher mass accuracy and greater dynamic range. The benefits of this approach were evaluated with proteomic and lipidomic datasets of varying complexities. After correcting the high concentration species, reduced mass errors and enhanced dynamic range were observed for both simple and complex omic samples. Specifically, the mass error dropped by more than 50% in most cases for highly saturated species and dynamic range increased by 1-2 orders of magnitude for peptides in a blood serum sample.

3.
Mol Cell Proteomics ; 13(4): 1119-27, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24403597

RESUMO

Rapid diagnosis of disease states using less invasive, safer, and more clinically acceptable approaches than presently employed is a crucial direction for the field of medicine. While MS-based proteomics approaches have attempted to meet these objectives, challenges such as the enormous dynamic range of protein concentrations in clinically relevant biofluid samples coupled with the need to address human biodiversity have slowed their employment. Herein, we report on the use of a new instrumental platform that addresses these challenges by coupling technical advances in rapid gas phase multiplexed ion mobility spectrometry separations with liquid chromatography and MS to dramatically increase measurement sensitivity and throughput, further enabling future high throughput MS-based clinical applications. An initial application of the liquid chromatography--ion mobility spectrometry-MS platform analyzing blood serum samples from 60 postliver transplant patients with recurrent fibrosis progression and 60 nontransplant patients illustrates its potential utility for disease characterization.


Assuntos
Cirrose Hepática/sangue , Cirrose Hepática/complicações , Proteoma/metabolismo , Proteômica/métodos , Cromatografia Líquida , Humanos , Íons/química , Cirrose Hepática/metabolismo , Transplante de Fígado , Espectrometria de Massas , Proteômica/instrumentação
4.
Anal Chem ; 86(13): 6268-76, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24881670

RESUMO

Glycomics quintavariate-informed quantification (GlyQ-IQ) is a biologically guided glycomics analysis tool for identifying N-glycans in liquid chromatography-mass spectrometry (LC-MS) data. Glycomics LC-MS data sets have convoluted extracted ion chromatograms that are challenging to deconvolve with existing software tools. LC deconvolution into constituent pieces is critical in glycomics data sets because chromatographic peaks correspond to different intact glycan structural isomers. The biological targeted analysis approach offers several key advantages to traditional LC-MS data processing. A priori glycan information about the individual target's elemental composition allows for improved sensitivity by utilizing the exact isotope profile information to focus chromatogram generation and LC peak fitting on the isotopic species having the highest intensity. Glycan target annotation utilizes glycan family relationships and in source fragmentation in addition to high specificity feature LC-MS detection to improve the specificity of the analysis. The GlyQ-IQ software was developed in this work and evaluated in the context of profiling the N-glycan compositions from human serum LC-MS data sets. A case study is presented to demonstrate how GlyQ-IQ identifies and removes confounding chromatographic peaks from high mannose glycan isomers from human blood serum. In addition, GlyQ-IQ was used to generate a broad human serum N-glycan profile from a high resolution nanoelectrospray-liquid chromatography-tandem mass spectrometry (nESI-LC-MS/MS) data set. A total of 156 glycan compositions and 640 glycan isomers were detected from a single sample. Over 99% of the GlyQ-IQ glycan-feature assignments passed manual validation and are backed with high-resolution mass spectra.


Assuntos
Glicômica/métodos , Polissacarídeos/análise , Polissacarídeos/sangue , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Humanos , Software
5.
Bioinformatics ; 29(21): 2804-5, 2013 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-24008421

RESUMO

MOTIVATION: The addition of ion mobility spectrometry to liquid chromatography-mass spectrometry experiments requires new, or updated, software tools to facilitate data processing. RESULTS: We introduce a command line software application LC-IMS-MS Feature Finder that searches for molecular ion signatures in multidimensional liquid chromatography-ion mobility spectrometry-mass spectrometry (LC-IMS-MS) data by clustering deisotoped peaks with similar monoisotopic mass, charge state, LC elution time and ion mobility drift time values. The software application includes an algorithm for detecting and quantifying co-eluting chemical species, including species that exist in multiple conformations that may have been separated in the IMS dimension. AVAILABILITY: LC-IMS-MS Feature Finder is available as a command-line tool for download at http://omics.pnl.gov/software/LC-IMS-MS_Feature_Finder.php. The Microsoft.NET Framework 4.0 is required to run the software. All other dependencies are included with the software package. Usage of this software is limited to non-profit research to use (see README). CONTACT: rds@pnnl.gov. SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.


Assuntos
Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Software , Algoritmos , Análise por Conglomerados , Íons , Análise Espectral/métodos
6.
BMC Bioinformatics ; 14: 49, 2013 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-23398735

RESUMO

BACKGROUND: MultiAlign is a free software tool that aligns multiple liquid chromatography-mass spectrometry datasets to one another by clustering mass and chromatographic elution features across datasets. Applicable to both label-free proteomics and metabolomics comparative analyses, the software can be operated in several modes. For example, clustered features can be matched to a reference database to identify analytes, used to generate abundance profiles, linked to tandem mass spectra based on parent precursor masses, and culled for targeted liquid chromatography-tandem mass spectrometric analysis. MultiAlign is also capable of tandem mass spectral clustering to describe proteome structure and find similarity in subsequent sample runs. RESULTS: MultiAlign was applied to two large proteomics datasets obtained from liquid chromatography-mass spectrometry analyses of environmental samples. Peptides in the datasets for a microbial community that had a known metagenome were identified by matching mass and elution time features to those in an established reference peptide database. Results compared favorably with those obtained using existing tools such as VIPER, but with the added benefit of being able to trace clusters of peptides across conditions to existing tandem mass spectra. MultiAlign was further applied to detect clusters across experimental samples derived from a reactor biomass community for which no metagenome was available. Several clusters were culled for further analysis to explore changes in the community structure. Lastly, MultiAlign was applied to liquid chromatography-mass spectrometry-based datasets obtained from a previously published study of wild type and mitochondrial fatty acid oxidation enzyme knockdown mutants of human hepatocarcinoma to demonstrate its utility for analyzing metabolomics datasets. CONCLUSION: MultiAlign is an efficient software package for finding similar analytes across multiple liquid chromatography-mass spectrometry feature maps, as demonstrated here for both proteomics and metabolomics experiments. The software is particularly useful for proteomic studies where little or no genomic context is known, such as with environmental proteomics.


Assuntos
Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Metabolômica/métodos , Proteômica/métodos , Software , Algoritmos , Carcinoma Hepatocelular/metabolismo , Análise por Conglomerados , Humanos , Neoplasias Hepáticas/metabolismo , Peptídeos/análise , Peptídeos/química , Proteoma/análise , Espectrometria de Massas em Tandem
7.
Int J Mass Spectrom ; 354-355: 312-317, 2013 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-25089116

RESUMO

Ion mobility spectrometry in conjunction with liquid chromatography separations and mass spectrometry offers a range of new possibilities for analyzing complex biological samples. To fully utilize the information obtained from these three measurement dimensions, informatics tools based on the accurate mass and time tag methodology were modified to incorporate ion mobility spectrometry drift times for peptides observed in human serum. In this work a reference human serum database was created for 12,139 peptides and populated with the monoisotopic mass, liquid chromatography normalized elution time, and ion mobility spectrometry drift time(s) for each. We demonstrate that the use of three dimensions for peak matching during the peptide identification process resulted in an increased numbers of identifications and a lower false discovery rate relative to only using the mass and normalized elution time dimensions.

8.
J Am Soc Mass Spectrom ; 25(12): 2020-2027, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24796262

RESUMO

Applying Hadamard transform multiplexing to ion mobility separations (IMS) can significantly improve the signal-to-noise ratio and throughput for IMS coupled mass spectrometry (MS) measurements by increasing the ion utilization efficiency. However, it has been determined that fluctuations in ion intensity as well as spatial shifts in the multiplexed data lower the signal-to-noise ratios and appear as noise in downstream processing of the data. To address this problem, we have developed a novel algorithm that discovers and eliminates data artifacts. The algorithm employs an analytical approach to identify and remove artifacts from the data, decreasing the likelihood of false identifications in subsequent data processing. Following application of the algorithm, IMS-MS measurement sensitivity is greatly increased and artifacts that previously limited the utility of applying the Hadamard transform to IMS are avoided. Figure ᅟ


Assuntos
Análise de Fourier , Espectrometria de Massas/métodos , Algoritmos , Artefatos , Proteômica
9.
J Am Soc Mass Spectrom ; 24(3): 444-9, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23423792

RESUMO

Chemical cross-linking of proteins followed by proteolysis and mass spectrometric analysis of the resulting cross-linked peptides provides powerful insight into the quaternary structure of protein complexes. Mixed-isotope cross-linking (a method for distinguishing intermolecular cross-links) was coupled with liquid chromatography, ion mobility spectrometry and mass spectrometry (LC-IMS-MS) to provide an additional separation dimension to the traditional cross-linking approach. This method produced multiplet m/z peaks that are aligned in the IMS drift time dimension and serve as signatures of intermolecular cross-linked peptides. We developed an informatics tool to use the amino acid sequence information inherent in the multiplet spacing for accurate identification of the cross-linked peptides. Because of the separation of cross-linked and non-cross-linked peptides in drift time, our LC-IMS-MS approach was able to confidently detect more intermolecular cross-linked peptides than LC-MS alone.


Assuntos
Reagentes de Ligações Cruzadas/química , Peptídeos/análise , Mapeamento de Interação de Proteínas/métodos , Proteínas/metabolismo , Espectrometria de Massas em Tandem/métodos , Sequência de Aminoácidos , Proteínas de Bactérias/química , Proteínas de Bactérias/metabolismo , Cromatografia Líquida/métodos , Marcação por Isótopo/métodos , Modelos Moleculares , Dados de Sequência Molecular , Peptídeos/metabolismo , Conformação Proteica , Proteínas/química , Proteínas Recombinantes/química , Proteínas Recombinantes/metabolismo , Análise de Sequência de Proteína/métodos , Shewanella/química , Shewanella/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA