Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 23(2): 574-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26917146

RESUMO

Localized spectroscopy with simultaneous topographic, elemental and magnetic information is presented. A synchrotron X-ray scanning tunneling microscope has been employed for the local study of the X-ray magnetic circular dichroism at the Fe L2,3-edges of a thin iron film grown on Cu(111). Polarization-dependent X-ray absorption spectra have been obtained through a tunneling smart tip that serves as a photoelectron detector. In contrast to conventional spin-polarized scanning tunneling microscopy, X-ray excitations provide magnetic contrast even with a non-magnetic tip. Intensity variations in the photoexcited tip current point to chemical variations within a single magnetic Fe domain.

2.
Nano Lett ; 14(11): 6499-504, 2014 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-25275823

RESUMO

By using synchrotron X-rays as a probe and a nanofabricated smart tip of a tunneling microscope as a detector, we have achieved chemical fingerprinting of individual nickel clusters on a Cu(111) surface at 2 nm lateral resolution, and at the ultimate single-atomic height sensitivity. Moreover, by varying the photon energy, we have succeeded to locally measure photoionization cross sections of just a single Ni nanocluster, which opens new exciting opportunities for chemical imaging of nanoscale materials.

3.
Opt Express ; 22(23): 28142-53, 2014 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-25402054

RESUMO

Focusing efficiency of Fresnel zone plates (FZPs) for X-rays depends on zone height, while the achievable spatial resolution depends on the width of the finest zones. FZPs with optimal efficiency and sub-100-nm spatial resolution require high aspect ratio structures which are difficult to fabricate with current technology especially for the hard X-ray regime. A possible solution is to stack several zone plates. To increase the number of FZPs within one stack, we first demonstrate intermediate-field stacking and apply this method by stacks of up to five FZPs with adjusted diameters. Approaching the respective optimum zone height, we maximized efficiencies for high resolution focusing at three different energies, 10, 11.8, and 25 keV.


Assuntos
Lentes , Refratometria/instrumentação , Espalhamento de Radiação , Difração de Raios X/instrumentação , Desenho de Equipamento , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA