RESUMO
The 2022 mpox outbreak primarily involved sexual transmission among men who have sex with men and disproportionately affected persons with human immunodeficiency virus (HIV). We examined viral dynamics and clinical features in a cohort evaluated for mpox infection at a comprehensive HIV clinic in Atlanta, Georgia. Viral DNA was found in 8 oropharyngeal and 5 anorectal specimens among 10 mpox cases confirmed by lesion swab polymerase chain reaction. Within-participant anatomic site of lowest cycle threshold (Ct) value varied, and lower Ct values were found in oropharyngeal and anorectal swabs when corresponding symptoms were present. This provides insight into mpox infection across multiple anatomic sites among people with HIV.
Assuntos
Infecções por HIV , Mpox , Minorias Sexuais e de Gênero , Masculino , Humanos , Homossexualidade Masculina , Instituições de Assistência AmbulatorialRESUMO
Detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection is essential for diagnosis, treatment, and infection control. Polymerase chain reaction (PCR) fails to distinguish acute from resolved infections, as RNA is frequently detected after infectiousness. We hypothesized that nucleocapsid in blood marks acute infection with the potential to enhance isolation and treatment strategies. In a retrospective serosurvey of inpatient and outpatient encounters, we categorized samples along an infection timeline using timing of SARS-CoV-2 testing and symptomatology. Among 1860 specimens from 1607 patients, the highest levels and frequency of antigenemia were observed in samples from acute SARS-CoV-2 infection. Antigenemia was higher in seronegative individuals and in those with severe disease. In our analysis, antigenemia exhibited 85.8% sensitivity and 98.6% specificity as a biomarker for acute coronavirus disease 2019 (COVID-19). Thus, antigenemia sensitively and specifically marks acute SARS-CoV-2 infection. Further study is warranted to determine whether antigenemia may aid individualized assessment of active COVID-19.
Assuntos
COVID-19 , Humanos , SARS-CoV-2 , Teste para COVID-19 , Estudos Retrospectivos , Sensibilidade e Especificidade , Nucleocapsídeo , BiomarcadoresRESUMO
There is increasing evidence for the importance of the gut microbiome in human health and disease. Traditional and modern technologies - from cell culture to next generation sequencing - have facilitated these advances in knowledge. Each of the tools employed in measuring the microbiome exhibits unique capabilities that may be leveraged for clinical diagnostics. However, much still needs to be done to standardize the language and metrics by which a microbiome is characterized. Here we review the capabilities of gut microbiome-based diagnostics, review selected examples, and discuss the outlook towards clinical application.
Assuntos
Técnicas de Laboratório Clínico , Microbioma Gastrointestinal/genética , Biologia Computacional , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , MetagenômicaRESUMO
Sepsis, a life-threatening syndrome that contributes to millions of deaths annually worldwide, represents a moral and economic burden to the healthcare system. Although no single, or even a combination of biomarkers has been validated for the diagnosis of sepsis, multiple studies have shown the high specificity of CD64 expression on neutrophils (nCD64) to sepsis. The analysis of elevated nCD64 in the first 2-6 hours after infection during the pro-inflammatory stage could significantly contribute to early sepsis diagnosis. Therefore, a rapid and automated device to periodically measure nCD64 expression at the point-of-care (POC) could lead to timely medical intervention and reduced mortality rates. Current accepted technologies for measuring nCD64 expression, such as flow cytometry, require manual sample preparation and long incubation times. For POC applications, however, the technology should be able to measure nCD64 expression with little to no sample preparation. In this paper, we demonstrate a smartphone-imaged microfluidic biochip for detecting nCD64 expression in under 50 min. In our assay, first unprocessed whole blood is injected into a capture chamber to immunologically capture nCD64 along a staggered array of pillars, which were previously functionalized with an antibody against CD64. Then, an image of the capture channel is taken using a smartphone-based microscope. This image is used to measure the cumulative fraction of captured cells (γ) as a function of length in the channel. During the image analysis, a statistical model is fitted to γ in order to extract the probability of capture of neutrophils per collision with a pillar (ε). The fitting shows a strong correlation with nCD64 expression measured using flow cytometry (R2 = 0.82). Finally, the applicability of the device to sepsis was demonstrated by analyzing nCD64 from 8 patients (37 blood samples analyzed) along the time they were admitted to the hospital. Results from this analysis, obtained using the smartphone-imaged microfluidic biochip were compared with flow cytometry. Again, a correlation coefficient R2 = 0.82 (slope = 0.99) was obtained demonstrating a good linear correlation between the two techniques. Deployment of this technology in ICU could significantly enhance patient care worldwide.
Assuntos
Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/métodos , Neutrófilos/imunologia , Receptores de IgG/sangue , Sepse/diagnóstico , Smartphone , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Feminino , Citometria de Fluxo , Humanos , Masculino , Técnicas Analíticas Microfluídicas/instrumentação , Pessoa de Meia-Idade , Testes ImediatosRESUMO
Background: Studies of the diagnostic performance of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleocapsid antigen in blood (antigenemia) have reached variable conclusions. The potential utility of antigenemia measurements as a clinical diagnostic test needs clarification. Methods: We performed a systematic review of Pubmed, Embase, and Scopus through July 15, 2023, and requested source data from corresponding authors. Results: Summary sensitivity from 16 studies (4543 cases) sampled at ≤14 days of symptoms was 0.83 (0.75-0.89), and specificity was 0.98 (0.87-1.00) from 6 studies (792 reverse transcription polymerase chain reaction-negative controls). Summary sensitivity and specificity for paired respiratory specimens with cycle threshold values ≤33 were 0.91 (0.85-0.95) and 0.56 (0.39-0.73) from 10 studies (612 individuals). Source data from 1779 cases reveal that >70% have antigenemia 2 weeks following symptom onset, which persists in <10% at 28 days. The available studies suffer from heterogeneity, and Omicron-era data are scarce. Conclusions: Nucleocapsid antigenemia currently has limited utility due to limitations of existing studies and lack of Omicron-era data. Improved study designs targeting potential clinical uses in screening, surveillance, and complex clinical decision-making-especially in immunocompromised patients-are needed.
RESUMO
The emergence of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Alpha variant in 2020 demonstrated the need for reanalysis of diagnostic tests to ensure detection of emerging variants. Here, we present a protocol for creating and characterizing SARS-CoV-2 variant testing panels using remnant clinical samples for diagnostic assay testing. We describe steps for characterizing SARS-CoV-2 remnant clinical samples and preparing them into pools and their use in preparing varying quantities of virus. We then detail procedures for verifying variant detection using the resulting sample panel. For complete details on the use and execution of this protocol, please refer to Rao et al.1,2.
Assuntos
COVID-19 , SARS-CoV-2 , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Humanos , COVID-19/diagnóstico , COVID-19/virologia , Teste para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/métodos , Manejo de Espécimes/métodosRESUMO
Anorectal and oropharyngeal exposures are implicated in sexual transmission of mpox, but authorized assays in the United States are only validated with cutaneous lesion swabs. Diagnostic assays for anorectal and oropharyngeal swabs are needed to address potential future outbreaks. The Cepheid Xpert® Mpox is the first point-of-care assay to receive FDA emergency use authorization in the United States and would be a valuable tool for evaluating these sample types. Our exploratory study demonstrates 100 % positive agreement with our in-house PCR assay for natural positive anorectal and oropharyngeal specimens and 92 % sensitivity with low-positive spiked specimens. The Xpert® assay detected viral DNA in specimens not detected by our reference PCR assay from four participants with mpox DNA at other sites, suggesting it may be more sensitive at low viral loads. In conclusion, the validation of the Xpert® for oropharyngeal and anorectal sample types can be rapidly achieved if clinical need returns and prospective samples become available.
Assuntos
Mpox , Humanos , Estados Unidos , Estudos Prospectivos , Sensibilidade e Especificidade , Manejo de Espécimes , Reação em Cadeia da PolimeraseRESUMO
Limited data highlight the need to understand differences in SARS-CoV-2 omicron (B.1.1.529) variant viral load between the gold standard nasopharyngeal (NP) swab, mid-turbinate (MT)/anterior nasal swabs, oropharyngeal (OP) swabs, and saliva. MT, OP, and saliva samples from symptomatic individuals in Atlanta, GA, in January 2022 and longitudinal samples from a small familial cohort were tested by both RT-PCR and ultrasensitive antigen assays. Higher concentrations in the nares were observed in the familial cohort, but a dominant sample type was not found among 39 cases in the cross-sectional cohort. The composite of positive MT or OP assay for both RT-PCR and antigen assay trended toward higher diagnostic yield but did not achieve significant difference. Our data did not identify a singular preferred sample type for SARS-CoV-2 testing, but higher levels of saliva nucleocapsid, a trend toward higher yield of composite OP/MT result, and association of apparent MT or OP predominance with symptoms warrant further study.
RESUMO
Low-cost detection of pathogens and biomolecules at the point-of-care promises to revolutionize medicine through more individualized monitoring and increased accessibility to diagnostics in remote and resource-limited areas. While many approaches to biosensing are still limited by expensive components or inadequate portability, we present here an ELISA-inspired lab-on-a-chip strategy for biological detection based on liposome tagging and ion-release impedance spectroscopy. Ion-encapsulating dipalmitoylphosphatidylcholine (DPPC) liposomes can be functionalized with antibodies and are stable in deionized water yet permeabilized for ion release upon heating, making them ideal reporters for electrical biosensing of surface-immobilized antigens. We demonstrate the quantification of these liposomes by real-time impedance measurements, as well as the qualitative detection of viruses as a proof-of-concept toward a portable platform for viral load determination which can be applied broadly to the detection of pathogens and other biomolecules.
Assuntos
Técnicas Biossensoriais/métodos , Lipossomos/química , Técnicas Analíticas Microfluídicas/métodos , 1,2-Dipalmitoilfosfatidilcolina/análogos & derivados , 1,2-Dipalmitoilfosfatidilcolina/química , Espectroscopia Dielétrica , Impedância Elétrica , Íons , Vírus/isolamento & purificaçãoRESUMO
The Ellume COVID-19 home test from Ellume Health (Brisbane, Aus) became the first COVID-19 diagnostic tool authorized for home use by the United States FDA in December 2020. This early pandemic success was built on over ten years of work on the Ellume influenza home test. Ellume overcame critical technology challenges during the development of their influenza test. In addition, it faced a recall of its COVID-19 home test in 2021 due to false positive results. While Ellume initially persevered through the recall and restarted sales in the United States, the combination of the recall and the wide availability of competitors' low-cost over the counter tests in the United States led to Ellume entering voluntary administration in September 2022. This paper traces the history of Ellume and how 10 years of experience with a home influenza test allowed the company to quickly develop the Ellume COVID-19 home test. We will also provide to diagnostic developers the key strategies employed by Ellume to succeed while highlighting the pitfalls that have challenged the company's business success.
Assuntos
COVID-19 , Influenza Humana , Humanos , Estados Unidos , COVID-19/diagnóstico , PandemiasRESUMO
BACKGROUND: Nucleocapsid antigenemia in adults has demonstrated high sensitivity and specificity for acute infection, and antigen burden is associated with disease severity. Data regarding SARS-CoV-2 antigenemia in children are limited. METHODS: We retrospectively analyzed blood plasma specimens from hospitalized children with COVID-19 or MIS-C. Nucleocapsid and spike were measured using ultrasensitive immunoassays. RESULTS: We detected nucleocapsid antigenemia in 62% (50/81) and spike antigenemia in 27% (21/79) of children with acute COVID-19 but 0% (0/26) and 15% (4/26) with MIS-C from March 2020-March 2021. Higher nucleocapsid levels were associated with radiographic infiltrates and respiratory symptoms in children with COVID-19. CONCLUSIONS: Antigenemia lacks the sensitivity to diagnose acute infection in children but is associated with signs and symptoms of lower respiratory tract involvement. Further study into the mechanism of antigenemia, its association with specific organ involvement, and the role of antigenemia in the pathogenesis of COVID-19 is warranted.
Assuntos
COVID-19 , SARS-CoV-2 , Adulto , Humanos , Criança , Estudos Retrospectivos , Anticorpos AntiviraisRESUMO
Introduction: Swab pooling may allow for more efficient use of point-of-care assays for SARS-CoV-2 detection in settings where widespread testing is warranted, but the effects of pooling on assay performance are not well described. Methods: We tested the Thermo-Fisher Accula rapid point-of-care RT-PCR platform with contrived pooled nasal swab specimens. Results: We observed a higher limit of detection of 3,750 copies/swab in pooled specimens compared to 2,250 copies/swab in individual specimens. Assay performance appeared worse in a specimen with visible nasal mucous and debris, although performance was improved when using a standard laboratory mechanical pipette compared to the transfer pipette included in the assay kit. Conclusion: Clinicians and public health officials overseeing mass testing efforts must understand limitations and benefits of swab or sample pooling, including reduced assay performance from pooled specimens. We conclude that the Accula RT-PCR platform remains an attractive candidate assay for pooling strategies owing to the superior analytical sensitivity compared to most home use and point-of-care tests despite the inhibitory effects of pooled specimens we characterized.
RESUMO
Background: Nasopharyngeal qualitative reverse-transcription polymerase chain reaction (RT-PCR) is the gold standard for diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, but it is not practical or sufficient in every clinical scenario due to its inability to distinguish active from resolved infection. Alternative or adjunct testing may be needed to guide isolation precautions and treatment in patients admitted to the hospital. Methods: We performed a single-center, retrospective analysis of residual clinical specimens and medical record data to examine blood plasma nucleocapsid antigen as a candidate biomarker of active SARS-CoV-2. Adult patients admitted to the hospital or presenting to the emergency department with SARS-CoV-2 ribonucleic acid (RNA) detected by RT-PCR from a nasopharyngeal swab specimen were included. Both nasopharyngeal swab and a paired whole blood sample were required to be available for analysis. Results: Fifty-four patients were included. Eight patients had positive nasopharyngeal swab virus cultures, 7 of whom (87.5%) had concurrent antigenemia. Nineteen (79.2%) of 24 patients with detectable subgenomic RNA and 20 (80.0%) of 25 patients with N2 RT-PCR cycle threshold ≤ 33 had antigenemia. Conclusions: Most individuals with active SARS-CoV-2 infection are likely to have concurrent antigenemia, but there may be some individuals with active infection in whom antigenemia is not detectable. The potential for high sensitivity and convenience of a blood test prompts interest in further investigation as a screening tool to reduce reliance on nasopharyngeal swab sampling and as an adjunct diagnostic test to aid in clinical decision making during the period after acute coronavirus disease 2019.
RESUMO
Traditional cellular and live-virus methods for detection of SARS-CoV-2 neutralizing antibodies (nAbs) are labor- and time-intensive, and thus not suited for routine use in the clinical lab to predict vaccine efficacy and natural immune protection. Here, we report the development and validation of a rapid, high throughput method for measuring SARS-CoV-2 nAbs against native-like trimeric spike proteins. This assay uses a blockade of human angiotensin converting enzyme 2 (hACE-2) binding (BoAb) approach in an automated digital immunoassay on the Quanterix HD-X platform. BoAb assays using Wuhan-WT (vaccine strain), delta (B.1.167.2), omicron BA1 and BA2 variant viral strains showed strong correlation with cell-based pseudovirus neutralization activity (PNA) and live-virus neutralization activity. Importantly, we were able to detect similar patterns of delta and omicron variant resistance to neutralization in samples with paired vaccine strain and delta variant BoAb measurements. Finally, we screened clinical samples from patients with or without evidence of SARS-CoV-2 exposure by a single-dilution screening version of our assays, finding significant nAb activity only in exposed individuals. Importantly, this completely automated assay can be performed in 4 h to measure neutralizing antibody titers for 16 samples over 8 serial dilutions or, 128 samples at a single dilution with replicates. In principle, these assays offer a rapid, robust, and scalable alternative to time-, skill-, and cost-intensive standard methods for measuring SARS-CoV-2 nAb levels.
RESUMO
The COVID-19 pandemic has proven the need for point-of-care diagnosis of respiratory diseases and microfluidic technology has risen to the occasion. Mesa Biotech (San Diego, CA) originally developed the Accula platform for the diagnosis of influenza A and B and then extended the platform to SARS-CoV-2. Mesa Biotech has experienced tremendous success, culminating in acquisition by Thermo Fisher for up to $550m USD. The Accula microfluidics platform accomplished the leap from the lab to commercial product through clever design and engineering choices. Through information obtained from interviews with key Mesa Biotech leaders and publicly-available documents, we describe the keys to Mesa's success and how they might inform other lab-on-a-chip companies.
Assuntos
COVID-19 , Pandemias , Biotecnologia , COVID-19/diagnóstico , Humanos , Microfluídica , SARS-CoV-2RESUMO
BACKGROUND: Pneumocystis jirovecii polymerase chain reaction (PCR) testing is a sensitive diagnostic tool but does not distinguish infection from colonization. Cycle threshold (CT) may correlate with fungal burden and could be considered in clinical decision making. Clinical use of PCR and significance of CT values have not previously been examined with the DiaSorin Molecular platform. METHODS: Retrospective review of P jirovecii PCR, CT values and clinical data from 18 months in a multihospital academic health system. The diagnostic performance of PCR with respect to pathology and correlation of CT with severity were examined. RESULTS: Ninety-nine of 1006 (9.8%) assays from 786 patients in 919 encounters were positive. Among 91 (9.9%) encounters in which P jirovecii pneumonia (PJP) was treated, 41 (45%) were influenced by positive PCR. Negative PCR influenced discontinuation of therapy in 35 cases. Sensitivity and specificity of PCR were 93% (95% CI, 68%-100%) and 94% (95% CI, 91%-96%) with respect to pathology. CT values from deep respiratory specimens were significantly different among treated patients (Pâ =â .04) and those with positive pathology results (P < .0001) compared to patients not treated and those with negative pathology, respectively, and was highly predictive of positive pathology results (area under the curve = 0.92). No significant difference was observed in comparisons based on indicators of disease severity. CONCLUSIONS: Pneumocystis jirovecii PCR was a highly impactful tool in the diagnosis and management of PJP, and use of CT values may have value in the treatment decision process in select cases. Further investigation in a prospective manner is needed.
RESUMO
Amoebic encephalitis is a rare cause of CNS infection for which mortality exceeds 90%. We present the case of a 27-year-old man with AIDS who presented to a hospital in Atlanta (Georgia, USA) with tonic-clonic seizures and headache. His clinical condition deteriorated over several days. Brain biopsy revealed lymphohistiocytic inflammation and necrosis with trophozoites and encysted forms of amoebae. Immunohistochemical and PCR testing confirmed Acanthamoeba castellanii encephalitis, typically described as granulomatous amoebic encephalitis (GAE). No proven therapy for GAE is available, although both surgical and multiagent antimicrobial treatment strategies are often used. Most recently, these include the antileishmanial agent miltefosine. Here we review all cases of GAE due to Acanthamoeba spp in people with HIV/AIDS identified in the literature and reported to the Centers for Disease Control and Prevention. We describe this case as a reminder to the clinician to consider protozoal infections, especially free-living amoeba, in the immunocompromised host with a CNS infection refractory to traditional antimicrobial therapy.
Assuntos
Acanthamoeba castellanii , Síndrome da Imunodeficiência Adquirida , Amebíase , Antiprotozoários , Encefalite , Adulto , Amebíase/diagnóstico , Amebíase/tratamento farmacológico , Antiprotozoários/uso terapêutico , Encefalite/diagnóstico , Encefalite/tratamento farmacológico , Granuloma , Humanos , MasculinoRESUMO
Immunocompromised patients with prolonged coronavirus disease 2019 symptoms present diagnostic and therapeutic challenges. We measured viral nucleocapsid antigenemia in 3 patients treated with anti-CD20 immunotherapy who acquired severe acute respiratory syndrome coronavirus 2 infection and experienced protracted symptoms. Our results support nucleocapsid antigenemia as a marker of persistent infection and therapeutic response.
RESUMO
Traditional cellular and live-virus methods for detection of SARS-CoV-2 neutralizing antibodies (nAbs) are labor- and time-intensive, and thus not suited for routine use in the clinical lab to predict vaccine efficacy and natural immune protection. Here, we report the development and validation of a rapid, high throughput method for measuring SARS-CoV-2 nAbs against native-like trimeric spike proteins. This assay uses a blockade of hACE-2 binding (BoAb) approach in an automated digital immunoassay on the Quanterix HD-X platform. BoAb assays using vaccine and delta variant viral strains showed strong correlation with cell-based pseudovirus and live-virus neutralization activity. Importantly, we were able to detect similar patterns of delta variant resistance to neutralization in samples with paired vaccine and delta variant BoAb measurements. Finally, we screened clinical samples from patients with or without evidence of SARS-CoV-2 exposure by a single-dilution screening version of our assays, finding significant nAb activity only in exposed individuals. In principle, these assays offer a rapid, robust, and scalable alternative to time-, skill-, and cost-intensive standard methods for measuring SARS-CoV-2 nAb levels.
RESUMO
Traditional cellular and live-virus methods for detection of SARS-CoV-2 neutralizing antibodies (nAbs) are labor- and time-intensive, and thus not suited for routine use in the clinical lab to predict vaccine efficacy and natural immune protection. Here, we report the development and validation of a rapid, high throughput method for measuring SARS-CoV-2 nAbs against native-like trimeric spike proteins. This assay uses a blockade of hACE-2 binding (BoAb) approach in an automated digital immunoassay on the Quanterix HD-X platform. BoAb assays using vaccine and delta variant viral strains showed strong correlation with cell-based pseudovirus and live-virus neutralization activity. Importantly, we were able to detect similar patterns of delta variant resistance to neutralization in samples with paired vaccine and delta variant BoAb measurements. Finally, we screened clinical samples from patients with or without evidence of SARS-CoV-2 exposure by a single-dilution screening version of our assays, finding significant nAb activity only in exposed individuals. In principle, these assays offer a rapid, robust, and scalable alternative to time-, skill-, and cost-intensive standard methods for measuring SARS-CoV-2 nAb levels.