Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Assunto principal
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Phys Med Biol ; 69(12)2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38810619

RESUMO

Objective. Optical fiber-based scintillating dosimetry is a recent promising technique owing to the miniature size dosimeter and quality measurement in modern radiation therapy treatment. Despite several advantages, the major issue of using scintillating dosimeters is the Cerenkov effect and predominantly requires extra measurement corrections. Therefore, this work highlighted a novel micro-dosimetry technique to ensure Cerenkov-free measurement in radiation therapy treatment protocol by investigating several dosimetric characteristics.Approach.A micro-dosimetry technique was proposed with the performance evaluation of a novel infrared inorganic scintillator detector (IR-ISD). The detector essentially consists of a micro-scintillating head based on IR-emitting micro-clusters with a sensitive volume of 1.5 × 10-6mm3. The proposed system was evaluated under the 6 MV LINAC beam used in patient treatment. Overall measurements were performed using IBATMwater tank phantoms by following TRS-398 protocol for radiotherapy. Cerenkov measurements were performed for different small fields from 0.5 × 0.5 cm2to 10 × 10 cm2under LINAC. In addition, several dosimetric parameters such as percentage depth dose (PDD), high lateral resolution beam profiling, dose linearity, dose rate linearity, repeatability, reproducibility, and field output factor were investigated to realize the performance of the novel detector.Main results. This study highlighted a complete removal of the Cerenkov effect using a point-like miniature detector, especially for small field radiation therapy treatment. Measurements demonstrated that IR-ISD has acceptable behavior with dose rate variability (maximum standard deviation ∼0.18%) for the dose rate of 20-1000 cGy s-1. An entire linear response (R2= 1) was obtained for the dose delivered within the range of 4-1000 cGy, using a selected field size of 1 × 1 cm2. Perfect repeatability (max 0.06% variation from average) with day-to-day reproducibility (0.10% average variation) was observed. PDD profiles obtained in the water tank present almost identical behavior to the reference dosimeter with a build-up maximum depth dose at 1.5 cm. The small field of 0.5 × 0.5 cm2profiles have been characterized with a high lateral resolution of 100µm.Significance. Unlike recent plastic scintillation detector systems, the proposed micro-dosimetry system in this study requires no Cerenkov corrections and showed efficient performance for several dosimetric parameters. Therefore, it is expected that considering the detector correction factors, the IR-ISD system can be a suitable dose measurement tool, such as in small-field dose measurements, high and low gradient dose verification, and, by extension, in microbeam radiation and FLASH radiation therapy.


Assuntos
Radiometria , Radiometria/instrumentação , Radiometria/métodos , Imagens de Fantasmas , Dosagem Radioterapêutica , Microtecnologia/instrumentação , Humanos , Contagem de Cintilação/instrumentação
2.
Cancers (Basel) ; 16(6)2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38539532

RESUMO

BACKGROUND: An incidental axillary dose of adjuvant radiotherapy using tangential beams is usually given after breast-conserving surgery for breast cancer. The goal of this sub-study was to evaluate this incidental dose in the setting of post-mastectomy radiotherapy (PMRT) according to two different radiotherapy techniques. METHODS: Patients participating in a randomized SERC trial who received PMRT in a single center were included. We collected the incidental axillary dose delivered to the Berg level 1 using different dosimetric parameters and compared two techniques using Student's t-test: three-dimensional conformal radiotherapy (3D-CRT) and volumetric arc therapy (VMAT). RESULTS: We analyzed radiotherapy plans from 52 patients who received PMRT from 2012 to 2021. The mean dose delivered to the Berg level 1 was 37.2 Gy. It was significantly higher with VMAT than with 3D-CRT-43.6 Gy (SD = 3.1 Gy) versus 34.8 Gy (SD = 8.6 Gy) p < 0.001. Eighty-four percent of the Berg level 1 was covered by 40 Gy isodose in the VMAT group versus 55.5% in the 3D-CRT group p < 0.001. CONCLUSIONS: On the Berg level 1, PMRT gives a dose at least equivalent to the one given by post-breast-conserving surgery radiotherapy, making it possible to limit completion axillary lymph node dissections in select pN1a patients treated with a mastectomy. Modern radiotherapy techniques like VMAT tend to increase this incidental dose.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA