1.
Ear Hear ; 44(2): 306-317, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36279119

RESUMO

OBJECTIVES: This study compared the performance of a dynamic partial tripolar cochlear implant speech encoding strategy termed dynamic current focusing (DCF) to monopolar stimulation (MP) using spectro-temporal, temporal, and speech-in-noise recognition testing. DESIGN: DCF is a strategy that utilizes tripolar or high partial tripolar stimulation at threshold level and increases loudness by slowly widening current spread towards most comfortable level. Thirteen cochlear implant users were fitted with DCF and a non-steered MP matched on pulse rate, pulse width, and active electrodes. Nine participants completed the single-blinded within-subject crossover trial. Repeated testing consisted of four sessions. Strategies were allocated in a DCF-MP-DCF-MP or MP-DCF-MP-DCF design. Three-week adaptation periods ended with a test session in which speech-in-noise recognition (matrix speech-in-noise sentence test), spectro-temporal ripple tests (SMRT and STRIPES) and a temporal amplitude modulation detection test were conducted. All participants recorded their subjective experiences with both strategies using the Speech, Spatial and Qualities of Hearing Scale questionnaire. RESULTS: Participants' SMRT thresholds improved 0.40 ripples per octave ( p = 0.02, Bonferroni-corrected: p = 0.1) with DCF over MP at 65 dB SPL. No significant differences between the strategies were found on speech-in-noise recognition at conversational (65 dB SPL) and soft (45 dB SPL) loudness levels, temporal testing, STRIPES, or the SMRT at 45 dB SPL. After Bonferroni correction, a learning effect remained on the matrix speech-in-noise sentence test at both loudness levels (65 dB SPL: p = 0.01; 45 dB SPL: p = 0.02). There was no difference in learning effects over time between DCF and MP. Similarly, no significant differences were found in subjective experience on the Speech, Spatial and Qualities of Hearing Scale questionnaire. DCF reduced average battery life by 48% (5.1 hours) ( p < 0.001) compared to MP. CONCLUSIONS: DCF may improve spectral resolution over MP at comfortable loudness (65 dB SPL) in cochlear implant users. However, the evidence collected in this study was weak and the significant result disappeared after Bonferroni correction. Also, not all spectral tests revealed this improvement. As expected, battery life was reduced for DCF. Although the current study is limited by its small sample size, considering previous studies, DCF does not consistently improve speech recognition in noise over MP strategies.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Percepção da Fala , Humanos , Surdez/reabilitação , Ruído , Percepção da Fala/fisiologia
2.
Perfusion ; 37(1): 69-77, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33325335

RESUMO

INTRODUCTION: This study aimed to test a computer-driven cardiovascular model for the evaluation of the visceral flow during intra-aortic balloon pump (IABP) assistance. METHODS: The model includes a systemic and pulmonary circulation as well as a heart contraction model. The straight polyurethane tube aorta had a single visceral while four windkessel components mimicked resistance compliance of the brachiocephalic, renal and sub-mesenteric, pulmonary, and systemic circulation. Twelve flow probes were placed in the circuit to measure pressures and flows with the IABP on and off. RESULTS: With the balloon off, the meantime to reach the steady state was 48 ± 16 s; with the balloon on, this figure was 178 ± 20 s. The stability of pressure and flow signals was obtained after 72 ± 11 min. The number of cycles of stability of the system was 93 [86-103]. Measurements were reliable either with samples of 10 or 20 beats. Bland Altman method demonstrated the reliability of measurements. Finally, all measurements were comparable to published in vivo data. CONCLUSION: The presented mock circulation was reliable and gave values with high accuracy both at baseline and during mechanical assistance. This system allows evaluation of the mesenteric flow during IABP, under different clinical/hemodynamic conditions. Nonetheless, its translational potential needs to be further evaluated.


Assuntos
Contrapulsação , Coração Auxiliar , Aorta , Circulação Coronária , Hemodinâmica , Humanos , Balão Intra-Aórtico/métodos , Reprodutibilidade dos Testes
3.
Artif Organs ; 45(2): 159-162, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32780459

RESUMO

Intra-aortic balloon pump has been the most commonly employed cardiac assist device in the past, although, in recent years, its use in cardiogenic shock has been questioned. The pathophysiology of the proximal part of the balloon has been well studied, whereas, hemodynamics and flow below the distal portion of the balloon have not been fully understood yet. The distal flow contains a three-wave flow pattern during diastolic balloon expansion: a flow reduction in early diastole, a backflow in mid-diastole followed by a tele-diastolic flow. More research on this topic is warranted to better understand the physics of the distal part of the balloon and its interaction with the three components of the local regulatory system: intrinsic (local metabolic and myogenic), extrinsic (autonomic nervous system), and humoral (local or circulating vasoactive substances). These new insights will be a guide for new balloon designs that will allow enhanced performance and improved outcomes.


Assuntos
Coração Auxiliar/efeitos adversos , Balão Intra-Aórtico/efeitos adversos , Isquemia/prevenção & controle , Choque Cardiogênico/cirurgia , Vísceras/irrigação sanguínea , Sistema Nervoso Autônomo/fisiologia , Diástole/fisiologia , Desenho de Equipamento , Hemodinâmica/fisiologia , Humanos , Balão Intra-Aórtico/instrumentação , Isquemia/etiologia , Isquemia/fisiopatologia , Fluxo Sanguíneo Regional/fisiologia
4.
J Card Surg ; 36(3): 1030-1039, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33336497

RESUMO

BACKGROUND AND AIM: Classical and paradoxical low-flow, low-gradient (LFLG) aortic stenosis (AS) are the most challenging subtypes of AS. The current therapeutic options are aortic valve replacement (AVR) and conservative management: AVR promotes long-term survival but is invasive, while conservative management yields a poor prognosis but is noninvasive since it uses no aortic valve replacement (noAVR). The present meta-analysis investigated the rate of survival of patients with LFLG AS undergoing either AVR or noAVR interventions. METHODS: The meta-analysis compared the outcomes of AVR with those of noAVR in terms of patient survival. In both groups, a meta-regression was conducted to investigate the impact on patient survival of the left ventricular ejection fraction (LVEF), either preserved (paradoxical LFLG AS) or reduced (classical LFLG AS). RESULTS: The relative risk of survival between the AVR and noAVR groups was 1.99 [1.40, 2.82] (p = .0001), suggesting that survival tends to be better in AVR patients than in noAVR patients. The meta-regression revealed that a reduced LVEF may be related to a higher survival in AVR patients when compared to a preserved LVEF (p = .04). Finally, the analysis indicated that LVEF seems not to be prognostic of survival in noAVR patients (p = .18). CONCLUSIONS: Patients with LFLG AS have better survival if they undergo AVR. In AVR patients, reduced LVEF rather than preserved LVEF is related to better survival, whereas there seems to be no difference in prognostic value between reduced and preserved LVEF in noAVR patients.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Tratamento Conservador , Humanos , Estudos Retrospectivos , Índice de Gravidade de Doença , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
5.
BMC Cancer ; 20(1): 557, 2020 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-32539805

RESUMO

BACKGROUND: About 50% of non-small cell lung cancer (NSCLC) patients have metastatic disease at initial diagnosis, which limits their treatment options and, consequently, the 5-year survival rate (15%). Immune checkpoint inhibitors (ICI), either alone or in combination with chemotherapy, have become standard of care (SOC) for most good performance status patients. However, most patients will not obtain long-term benefit and new treatment strategies are therefore needed. We previously demonstrated clinical safety of the tumour-selective immunocytokine L19-IL2, consisting of the anti-ED-B scFv L19 antibody coupled to IL2, combined with stereotactic ablative radiotherapy (SABR). METHODS: This investigator-initiated, multicentric, randomised controlled open-label phase II clinical trial will test the hypothesis that the combination of SABR and L19-IL2 increases progression free survival (PFS) in patients with limited metastatic NSCLC. One hundred twenty-six patients will be stratified according to their metastatic load (oligo-metastatic: ≤5 or poly-metastatic: 6 to 10) and randomised to the experimental-arm (E-arm) or the control-arm (C-arm). The C-arm will receive SOC, according to the local protocol. E-arm oligo-metastatic patients will receive SABR to all lesions followed by L19-IL2 therapy; radiotherapy for poly-metastatic patients consists of irradiation of one (symptomatic) to a maximum of 5 lesions (including ICI in both arms if this is the SOC). The accrual period will be 2.5-years, starting after the first centre is initiated and active. Primary endpoint is PFS at 1.5-years based on blinded radiological review, and secondary endpoints are overall survival, toxicity, quality of life and abscopal response. Associative biomarker studies, immune monitoring, CT-based radiomics, stool collection, iRECIST and tumour growth rate will be performed. DISCUSSION: The combination of SABR with or without ICI and the immunocytokine L19-IL2 will be tested as 1st, 2nd or 3rd line treatment in stage IV NSCLC patients in 14 centres located in 6 countries. This bimodal and trimodal treatment approach is based on the direct cytotoxic effect of radiotherapy, the tumour selective immunocytokine L19-IL2, the abscopal effect observed distant from the irradiated metastatic site(s) and the memory effect. The first results are expected end 2023. TRIAL REGISTRATION: ImmunoSABR Protocol Code: NL67629.068.18; EudraCT: 2018-002583-11; Clinicaltrials.gov: NCT03705403; ISRCTN ID: ISRCTN49817477; Date of registration: 03-April-2019.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/terapia , Quimiorradioterapia/métodos , Neoplasias Pulmonares/terapia , Radiocirurgia/métodos , Proteínas Recombinantes de Fusão/administração & dosagem , Adulto , Carcinoma Pulmonar de Células não Pequenas/mortalidade , Carcinoma Pulmonar de Células não Pequenas/secundário , Quimiorradioterapia/efeitos adversos , Ensaios Clínicos Fase II como Assunto , Feminino , Humanos , Neoplasias Pulmonares/mortalidade , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto , Intervalo Livre de Progressão , Qualidade de Vida , Radiocirurgia/efeitos adversos , Ensaios Clínicos Controlados Aleatórios como Assunto , Proteínas Recombinantes de Fusão/efeitos adversos , Critérios de Avaliação de Resposta em Tumores Sólidos , Padrão de Cuidado
6.
Ear Hear ; 41(5): 1258-1269, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31977727

RESUMO

OBJECTIVES: Phantom electrode stimulation was developed for cochlear implant (CI) systems to provide a lower pitch percept by stimulating more apical regions of the cochlea, without inserting the electrode array deeper into the cochlea. Phantom stimulation involves simultaneously stimulating a primary and a compensating electrode with opposite polarity, thereby shifting the electrical field toward the apex and eliciting a lower pitch percept. The current study compared the effect sizes (in shifts of place of excitation) of multiple phantom configurations by matching the perceived pitch with phantom stimulation to that perceived with monopolar stimulation. Additionally, the effects of electrode location, type of electrode array, and stimulus level on the perceived pitch were investigated. DESIGN: Fifteen adult advanced bionics CI users participated in this study, which included four experiments to eventually measure the shifts in place of excitation with five different phantom configurations. The proportions of current delivered to the compensating electrode, expressed as σ, were 0.5, 0.6, 0.7, and 0.8 for the symmetrical biphasic pulses (SBC0.5, SBC0.6, SBC0.7, and SBC0.8) and 0.75 for the pseudomonophasic pulse shape (PSA0.75). A pitch discrimination experiment was first completed to determine which basal and apical electrode contacts should be used for the subsequent experiments. An extensive loudness balancing experiment followed where both the threshold level (T-level) and most comfortable level (M-level) were determined to enable testing at multiple levels of the dynamic range. A pitch matching experiment was then performed to estimate the shift in place of excitation at the chosen electrode contacts. These rough shifts were then used in the subsequent experiment, where the shifts in place of excitation were determined more accurately. RESULTS: Reliable data were obtained from 20 electrode contacts. The average shifts were 0.39, 0.53, 0.64, 0.76, and 0.53 electrode contacts toward the apex for SBC0.5, SBC0.6, SBC0.7, SBC0.8, and PSA0.75, respectively. When only the best configurations per electrode contact were included, the average shift in place of excitation was 0.92 electrode contacts (range: 0.25 to 2.0). While PSA0.75 leads to equal results as the SBC configurations in the apex, it did not result in a significant shift at the base. The shift in place of excitation was significantly larger at the apex and with lateral wall electrode contacts. The stimulus level did not affect the shift. CONCLUSIONS: Phantom stimulation results in significant shifts in place of excitation, especially at the apical part of the electrode array. The phantom configuration that leads to the largest shift in place of excitation differs between subjects. Therefore, the settings of the phantom electrode should be individualized so that the phantom stimulation is optimized for each CI user. The real added value to the sound quality needs to be established in a take-home trial.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Estimulação Acústica , Cóclea , Surdez/cirurgia , Estimulação Elétrica , Humanos , Discriminação da Altura Tonal , Percepção da Altura Sonora
7.
J Card Surg ; 35(3): 645-653, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31951676

RESUMO

BACKGROUND AND AIMS: The main pathophysiological factor of chronic ischemic mitral regurgitation (MR) is the outward displacement of the papillary muscles (PMs) leading to leaflet tethering. For this reason, papillary muscle intervention (PMI) in combination with mitral ring annuloplasty (MRA) has recently been introduced into clinical practice to correct this displacement, and to reduce the recurrence of regurgitation. METHODS: A meta-analysis was conducted comparing the outcomes of PMI and MRA performed in combination vs MRA performed alone, in terms of MR recurrence and left ventricular reverse remodeling (LVRR). A meta-regression was carried out to investigate the impact of the type of PMI procedure on the outcomes. RESULTS: MR recurrence in patients undergoing both PMI and MRA was lower than in those who only had MRA (log incidence rate ratio, -0.66; lower-upper limits, -1.13 to 0.20; I2 = 0.0%; p = .44; Egger's test: intercept 0.35 [-0.78 to 1.51]; p = .42). The group with both PMI and MRA and that with only MRA showed a slightly higher reduction in left ventricular diameters (-5.94%; -8.75% to 3.13%,). However, in both groups, LVRR was <10%. No difference was detected between PM relocation/repositioning and papillary muscle approximation in terms of LVRR (p = .33). CONCLUSIONS: Using PMI and MRA together has a lower MR recurrence than using MRA alone. No significant LVRR was observed between the two groups nor between the PMI techniques employed.


Assuntos
Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/cirurgia , Músculos Papilares/cirurgia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Prevenção Secundária , Remodelação Ventricular
8.
Exp Physiol ; 104(5): 643-653, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30821049

RESUMO

NEW FINDINGS: What is the central question of this study? Visceral ischaemia is one of the most feared complications during use of an intra-aortic balloon pump. Using an animal model, we measured the flows at the abdominal level directly and examined flow patterns to enable investigation of flow patterns during the use of the intra-aortic balloon pump. What is the main finding and its importance? We show that there is a significant balloon-related reduction in superior mesenteric flow in both early and mid-diastole. ABSTRACT: A number of previous studies have shown that blood flow in the visceral arteries is altered during intra-aortic balloon pump (IABP) treatment. We used a porcine model to analyse the pattern of blood flow into the visceral arteries during IABP use. For this purpose, we measured the superior mesenteric, right renal and left renal flows before and during IABP support, using surgically placed flowmeters surrounding these visceral arteries. The superior mesenteric flow significantly decreased in early diastole (P < 0.001) and in mid-diastole (P = 0.003 versus early diastole), whereas in late diastole it increased again (P < 0.001 versus mid-diastole). During systole, the flow was not significantly increased compared with late diastole (P = 0.51), but it was significantly lower than at baseline (both P < 0.001). Flows did not differ between right and left kidneys. Perfusion of either kidney did not change significantly in early diastole (P > 0.05), whereas it decreased significantly in mid-diastole (P < 0.001), rising dramatically in late diastole (P < 0.001) and with an additional slight increase in systole (P = 0.054). This study provides important insights into abdominal flows during intra-aortic pump counterpulsation. Furthermore, it supports the need to rethink the balloon design to avoid visceral ischaemia during circulatory assistance.


Assuntos
Balão Intra-Aórtico , Artéria Mesentérica Superior/fisiologia , Circulação Renal/fisiologia , Animais , Velocidade do Fluxo Sanguíneo , Contrapulsação , Diástole/fisiologia , Eletrocardiografia , Hemodinâmica , Monitorização Fisiológica , Reologia , Suínos , Sístole/fisiologia
9.
Ear Hear ; 40(1): 34-44, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29742542

RESUMO

OBJECTIVES: In an attempt to improve spectral resolution and speech intelligibility, several current focusing methods have been proposed to increase spatial selectivity by decreasing intracochlear current spread. For example, tripolar stimulation administers current to a central electrode and uses the two flanking electrodes as the return pathway, creating a narrower intracochlear electrical field and hence increases spectral resolution when compared with monopolar (MP) stimulation. However, more current is required, and in some patients, specifically the ones with high electrode impedances, full loudness growth cannot be supported because of compliance limits. The present study describes and analyses a new loudness encoding approach that uses tripolar stimulation near threshold and gradually broadens the excitation (by decreasing compensation coefficient σ) to increase loudness without the need to increase overall current. It is hypothesized that this dynamic current focusing (DCF) strategy increases spatial selectivity, especially at lower loudness levels, while maintaining maximum selectivity at higher loudness levels, without reaching compliance limits. DESIGN: Eleven adult cochlear implant recipients with postlingual hearing loss, with at least 9 months of experience with their HiRes90K implant, were selected to participate in this study. Baseline performance regarding speech intelligibility in noise (Dutch matrix sentence test), spectral ripple discrimination at 45 and 65 dB, and temporal modulation detection thresholds were assessed using their own clinical program, fitted on a Harmony processor. Subsequently, the DCF strategy was fitted on a research Harmony processor. Threshold levels were determined with σ = 0.8, which means 80% of current is returned to the flanking electrodes and the remaining 20% to the extracochlear ground electrode. Instead of increasing overall pulse magnitude, σ was decreased to determine most comfortable loudness. After 2 to 3 hr of adaptation to the research strategy, the same psychophysical measures were taken. RESULTS: At 45 dB, average spectral ripple scores improved significantly from 2.4 ripples per octave with their clinical program to 3.74 ripples per octave with the DCF strategy (p = 0.016). Eight out of 11 participants had an improved spectral resolution at 65 dB. Nevertheless, no significant difference between DCF and MP was observed at higher presentation levels. Both speech-in-noise and temporal modulation detection thresholds were equal for MP and DCF strategies. Subjectively, 2 participants preferred the DCF strategy over their own clinical program, 2 preferred their own strategy, while the majority of the participants had no preference. Battery life was decreased and ranged from 1.5 to 4 hr. CONCLUSIONS: The DCF strategy gives better spectral resolution, at lower loudness levels, but equal performance on speech tests. These outcomes warrant for a longer adaptation period to study long-term outcomes and evaluate if the outcomes in the ripple tests transfer to the speech scores. Further research, for example, with respect to fitting rules and reduction of power consumption, is necessary to make the DCF strategy suitable for routine clinical application.


Assuntos
Implantes Cocleares , Perda Auditiva/reabilitação , Percepção da Fala , Idoso , Implante Coclear , Feminino , Perda Auditiva/fisiopatologia , Humanos , Percepção Sonora , Masculino , Pessoa de Meia-Idade , Ruído
10.
J Card Surg ; 34(11): 1297-1304, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31472023

RESUMO

BACKGROUND AND AIMS: We investigated neurological events, graft patency, major adverse cardiovascular events (MACEs), and mortality at 1 year following coronary artery bypass grafting (CABG) surgery using automated proximal anastomotic devices (APADs) and compared the overall rates with the current literature. METHODS: A systematic review of all available reports of APADs use in the literature was conducted. Cumulative incidence and 95% confidence interval (CI) were the main statistical indexes. Nine observational studies encompassing a total of 718 patients were included at the end of the selection process. RESULTS: The cumulative event rate of neurological complications was 4.8% (lower-upper limits: 2.8-8.0, P < .001; I2 = 72.907%, P = .002; Egger's test: intercept = -2.47, P = 0.16; Begg and Mazumdar test: τ = -0.20, p = 0.57). Graft patency was 90.5% (80.4 to 95.7, P < .001; I2 = 76.823%, P = .005; Egger's test: intercept = -3.04, P = .10; Begg and Mazumdar test: τ = -0.67, P = .17). Furthermore, the overall incidence of MACEs was 3.7% (1.3-10.4, P < .001; I2 = 51.556%, P = .103; Egger's test: intercept = -1.98, P = < .11; Begg and Mazumdar test: τ = -0.67, P = .17). Finally, mortality within 1 year was 5% (3.5-7, P < .001; I2 = 29.675%, P = .202; Egger's test: intercept = -0.91, P = .62; Begg and Mazumdar test: τ = -0.04, P = .88). CONCLUSIONS: APADs do not seem to be correlated with a reduction of either neurological events or mortality. By contrast, these tools showed satisfactory one-year graft patency and a low incidence of MACEs. Further research on this topic is warranted.


Assuntos
Ponte de Artéria Coronária , Ponte de Artéria Coronária/efeitos adversos , Humanos , Resultado do Tratamento
11.
Int J Audiol ; 58(9): 553-564, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31012768

RESUMO

Objective: This study aimed to evaluate a more energy-efficient dynamic current focussing (DCF) speech-processing strategy after long-term listening experience. In DCF, tripolar stimulation is used near the threshold and loudness is controlled by the compensation coefficient σ. A recent acute pilot study showed improved spectral-temporally modulated ripple test (SMRT) scores at low loudness levels, but battery life was reduced to 1.5-4 hours. Design: Within-subject comparisons were made for the clinical versus. DCF strategy after 5 weeks of at-home usage. Speech intelligibility in noise, spectral ripple discrimination, temporal modulation detection, loudness growth, and subjective ratings were assessed. Study sample: Twenty HiRes90K (Advanced Bionics, Valencia, USA) cochlear implant (CI) users. Results: Average battery life was 9 hours with the newly implemented DCF compared to 13.4 hours with the clinical strategy. Compared with measurements made at the beginning of the study, SMRT-scores and speech intelligibility in noise were significantly improved with DCF. However, both measures suffered from unexpected learning effects over time. The improvement disappeared and speech intelligibility in noise declined significantly relative to the final control measurement with the clinical strategy. Conclusion: Most CI users can adapt to the DCF strategy in a take-home setting. Although DCF has the potential to improve performance on the SMRT test, learning effects complicate the interpretation of the current results.


Assuntos
Implantes Cocleares , Surdez/reabilitação , Aprendizagem/fisiologia , Percepção Sonora , Fatores de Tempo , Adulto , Idoso , Implante Coclear , Surdez/psicologia , Fontes de Energia Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ruído , Inteligibilidade da Fala , Percepção da Fala , Resultado do Tratamento
12.
Int J Audiol ; 58(5): 262-268, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30890005

RESUMO

OBJECTIVE: To test the channel discrimination of cochlear implant (CI) users along all contacts of the electrode array and assess whether this is related to speech perception. DESIGN: CI recipients were tested with a custom-made channel discrimination test. They were asked to distinguish a target stimulus from two reference stimuli in a three-alternative forced choice (3AFC) task. The target stimulus was evoked using current steering, with current steering coefficients (α) of 1, 0.5 and 0.25. The test provided a discrimination score (Dα) for each electrode contact along the array. STUDY SAMPLE: Thirty adults implanted with a CI from Advanced Bionics. RESULTS: Large variations in Dα scores were observed, both across the electrode array and between subjects. Statistical analysis revealed a significant channel-to-channel variability in Dα score (p < 0.01). Further, there was a significant relationship between subjects' Dα scores and their speech perception in quiet (p < 0.001). CONCLUSIONS: The large variations in Dα score emphasise the importance of testing pitch discrimination across the complete electrode array. The relationship between Dα score and speech perception indicates that pitch discrimination might be a contributing factor to the performance of individual implant users.


Assuntos
Implantes Cocleares , Discriminação da Altura Tonal , Percepção da Fala , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
13.
Perfusion ; 34(7): 538-543, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30868943

RESUMO

BACKGROUND: Extracorporeal membrane oxygenation constitutes a complex support modality, and accurate monitoring is required. An ideal monitoring system should promptly detect ECMO malfunctions and provide real-time information to optimize the patient-machine interactions. We tested a new volumetric capnometer which enables continuous monitoring of membrane lung carbon dioxide removal (V'CO2ML), to help in estimating the oxygenator performance, in terms of CO2 removal and oxygenator dead space (VDsML). METHODS: This study was conducted on nine pigs undergoing veno-arterial ECMO due to cardiogenic shock after induced acute myocardial infarction. The accuracy and reliability of the prototype of the volumetric capnometer (CO2RESET™, by Eurosets srl, Medolla, Italy) device was evaluated for V'CO2ML and VDsML measurements by comparing the obtained measurements from the new device to a control capnometer with the sweep gas values. Measurements were taken at five different levels of gas flow/blood flow ratio (0.5-1.5). Agreement between the corresponding measurements was taken with the two methods. We expected that 95% of differences were between d - 1.96s and d + 1.96s. RESULTS: In all, 120 coupled measurements from each device were obtained for the V'CO2ML calculation and 40 for the VDsML. The new capnometer mean percentage bias (95% confidence interval limits of agreement) was 3.86% (12.07-4.35%) for V'CO2ML and 2.62% (8.96-14.20%) for VDsML. A negative proportional bias for V'CO2ML estimation with the new device was observed with a mean of 3.86% (12.07-4.35%). No correlations were found between differences in the coupled V'CO2ML and VDsML measurements and the gas flow/blood flow ratio or temperature. Coupled measurements for V'CO2ML showed strong correlation (rs = 0.991; p = 0.0005), as did VDsML calculations (rs = 0.973; p = 0.0005). CONCLUSION: The volumetric capnometer is reliable for continuous monitoring of CO2 removal by membrane lung and VDsML calculations. Further studies are necessary to confirm these data.


Assuntos
Capnografia/métodos , Dióxido de Carbono/sangue , Oxigenação por Membrana Extracorpórea/métodos , Pulmão/patologia , Monitorização Fisiológica/métodos , Animais , Humanos , Suínos
14.
Ear Hear ; 39(3): 475-481, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28953491

RESUMO

OBJECTIVES: Psychophysical tests of spectral and temporal resolution, such as the spectral-ripple discrimination task and the temporal modulation detection test, are valuable tools for the evaluation of cochlear implant performance. Both tests correlate with speech intelligibility and are reported to show no instantaneous learning effect. However, some of our previous trials have suggested that there is a learning effect over time. The aim of this study was to investigate the test-retest reliability of the two tests when measured over time. DESIGN: Ten adult cochlear implant recipients, experienced with the HiResolution speech coding strategy, participated in this study. Spectral ripple discrimination and temporal modulation detection ability with the HiResolution strategy were assessed both before and after participation in a previous trial that evaluated two research speech coding strategies after 2 weeks of home-usage. Each test was repeated six times on each test day. RESULTS: No improvement was observed for same-day testing. However, comparison of the mean spectral ripple discrimination scores before and after participation in the take-home trial showed improvement from 3.4 to 4.8 ripples per octave (p < 0.001). The mean temporal modulation detection thresholds improved from -15.2 to -17.4 dB (p = 0.035). CONCLUSIONS: There was a clear learning effect over time in the spectral and temporal resolution tasks, but not during same-day testing. Learning effects may stem from perceptual learning, task learning, or a combination of those two factors. These results highlight the importance of a proper research design for evaluation of novel speech coding strategies, where the baseline measurement is repeated at the end of the trial to avoid false-positive results as a consequence of learning effects.


Assuntos
Implantes Cocleares , Aprendizagem , Testes de Discriminação da Fala , Percepção da Fala , Adulto , Limiar Auditivo , Humanos , Psicofísica , Reprodutibilidade dos Testes , Inteligibilidade da Fala
15.
Perfusion ; 33(2): 96-104, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28816093

RESUMO

BACKGROUND: The use of the intra-aortic balloon pump (IABP) as a support device remains controversial due to the fact that a number of studies have shown no benefit in end mortality whilst using this device. One of the reasons for this could be the increase in vascular complications when using the pump. Therefore, the aim of the present review was to assess the current literature available with regards to IABP vascular complications during the clinical situation. METHODS: A literature search was performed, searching for IABP complications in adult human studies between 1990 and 2016. RESULTS: A total of 20 reports were identified as fitting the criteria of this study. The majority of vascular complications were limb ischemia, bleeding or mesenteric ischemia. The overall incidence of vascular complications ranged from 0.94% to 31.1%. Diabetes, peripheral vascular disease and hypertension, as well as smoking were all identified as risk factors for complications following IABP. Furthermore, studies supported the use of sheathless balloon insertion to reduce the risk of complications. CONCLUSION: Major vascular complications, including limb and mesenteric ischemia as well as bleeding and hemorrhage, have been associated with IABP. However, the incidence of these complications was generally low. Further studies are still required to truly understand the risk/benefit associated with the use of IABP.


Assuntos
Doenças Cardiovasculares/etiologia , Coração Auxiliar/efeitos adversos , Hemorragia/etiologia , Balão Intra-Aórtico/instrumentação , Doenças Cardiovasculares/patologia , Feminino , Hemorragia/patologia , Humanos , Masculino , Medição de Risco , Fatores de Risco
16.
Perfusion ; 32(4): 285-295, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27864477

RESUMO

AIM: We evaluated the influence of intra-aortic balloon size and volume on mesenteric and renal flows. METHODS: Thirty healthy swine underwent 120-minute ligation of the left anterior descending coronary artery followed by 6 hours of reperfusion. Then, they were randomly assigned to the following five groups of animals, with six animals in each group: no intra-aortic balloon pump (IABP), a short 35-mL IABP, a short 40-mL IABP, a long 35-mL IABP and a long 40-mL IABP. Superior mesenteric artery (SMA) and renal flows were measured at baseline (t0), at 2-hour ischemia (t1) and every hour thereafter until 6 hours of reperfusion (from tR1 to tR6). RESULTS: SMA flows increased significantly at tR1 only in the two short IABP groups (p<0.001) and balloon volume did not appear to affect flows which, at any experimental time-point, were comparable using 35 mL or 40 mL balloons (p>0.05). Renal flows appeared to be influenced by balloon length, but not by volume. Indeed, flows in the renal arteries rose during IABP treatment; the increase was significantly higher in the short balloon groups and throughout the whole reperfusion (all, p<0.001). CONCLUSIONS: Changes in visceral perfusion during IABP assistance were significantly related to balloon length, but not to its volume. This could be relevant for the evolution of balloon engineering design in order to reduce the incidence of mesenteric ischemia following IABP. Further research is necessary to confirm these findings.


Assuntos
Balão Intra-Aórtico/métodos , Artéria Mesentérica Superior/fisiologia , Circulação Renal/fisiologia , Animais , Velocidade do Fluxo Sanguíneo , Modelos Animais de Doenças , Distribuição Aleatória , Suínos
17.
Europace ; 18(10): 1528-1537, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26721977

RESUMO

AIMS: To assess the results and impact of lesion set and surgical technique on long-term success of surgical ablation during mitral surgery. METHODS AND RESULTS: The patient population consisted of 685 subjects with persistent and long-standing persistent atrial fibrillation (AF) undergoing cardiac surgery for mitral valve disease as the primary indication and concomitant ablation between January 2003 and January 2012 at three institutions. One hundred and sixty-six underwent unipolar (24.2%), 371 (54.2%) bipolar, and 148 (21.6%) had combined ablation. Median follow-up was 58.4 months (interquartile range 43.3-67.9). To appropriately account for death, a competing risk model was employed to identify predictors of cumulative incidence of recurrent AF among lesion set and surgical techniques. Eight-year freedom from recurrent arrhythmia without antiarrhythmic drugs was 0.60 ± 0.02. Success rate was higher using bipolar radiofrequency (RF) (P < 0.001), after performing mitral isthmus line (P = 0.003) and following the biatrial technique (P < 0.001). Competing risk regression revealed that use of unipolar RF [sub-hazard ratio (SHR) 2.41 (1.52-3.43), P < 0.001], combined unipolar/bipolar ablation [SHR 1.93 (0.89-2.57), P = 0.003] and the absence of right atrial ablation [SHR 2.79 (1.27-3.48), P < 0.001] were predictors of cumulative incidence of long-term recurrence. CONCLUSIONS: Our experience suggests that the use of bipolar clamp improves long-term results in surgical treatment of AF and that right-sided ablation should be routinely added. Randomized studies are necessary to confirm our findings.


Assuntos
Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Ablação por Cateter/métodos , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/cirurgia , Valva Mitral/cirurgia , Idoso , Feminino , Seguimentos , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Países Baixos , Complicações Pós-Operatórias/mortalidade , Recidiva , Análise de Regressão , Estudos Retrospectivos , Resultado do Tratamento
18.
Case Rep Otolaryngol ; 2024: 2111531, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38549682

RESUMO

Head and neck paragangliomas are slow growing and highly vascular neuroendocrine tumors. It is currently assumed that SDHAF2 variants exclusively cause benign and often multicentric head and neck paragangliomas. Here, we present a patient diagnosed with multiple SDHAF2-linked head and neck paragangliomas who in addition developed paraganglioma metastases to the lung and spine and a primary or metastatic paraganglioma in the head of the pancreas. During the course of the disease, a range of management strategies were deployed for the different head and neck tumors, including total resections, partial resections, and active surveillance. After identification of the paraganglioma metastases, the patient was treated with lanreotide after which the disease remained stable during the 27 months of follow-up.

19.
Cancer Rep (Hoboken) ; 5(2): e1470, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34145976

RESUMO

BACKGROUND: Cyclin-dependent kinase (CDK) 4/6 inhibitors have recently been approved for the treatment of hormone receptor-positive and HER2-negative metastatic breast cancer in association with endocrine therapy in postmenopausal women. Data on the interaction of CDK4/6 inhibition and radiotherapy are scarce, but some studies show unexpected toxicity. CASES: We report three cases of unexpected severe or prolonged soft tissue, skin, and gastrointestinal toxicity in patients treated with a combination of radiotherapy and the CDK4/6 inhibitor palbociclib. CONCLUSION: These cases indicate a possible interaction between radiotherapy and palbociclib. Therefore, we recommend using radiotherapy cautiously when combined with CDK4/6 inhibitors.


Assuntos
Neoplasias da Mama/tratamento farmacológico , Piperazinas/efeitos adversos , Inibidores de Proteínas Quinases/efeitos adversos , Piridinas/efeitos adversos , Neoplasias Ósseas/radioterapia , Neoplasias Ósseas/secundário , Neoplasias da Mama/patologia , Neoplasias da Mama/radioterapia , Progressão da Doença , Feminino , Humanos , Pessoa de Meia-Idade , Manejo da Dor , Pós-Menopausa
20.
Autophagy ; 18(8): 1898-1914, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34904929

RESUMO

Hypoxia is a common feature of solid tumors and is associated with increased tumor progression, resistance to therapy and increased metastasis. Hence, tumor hypoxia is a prognostic factor independent of treatment modality. To survive hypoxia, cells activate macroautophagy/autophagy. Paradoxically, in several cancer types, mutations or loss of essential autophagy genes have been reported that are associated with earlier onset of tumor growth. However, to our knowledge, the phenotypic and therapeutic consequences of autophagy deficiency have remained unexplored. In this study, we determined autophagy-defects in head and neck squamous cell carcinoma (HNSCC) and observed that expression of ATG12 (autophagy related 12) was lost in 25%-40% of HNSCC. In line, ATG12 loss is associated with absence of hypoxia, as determined by pimonidazole immunohistochemistry. Hence, ATG12 loss is associated with improved prognosis after therapy in two independent HNSCC cohorts and 7 additional cancer types. In vivo, ATG12 targeting resulted in decreased hypoxia tolerance, increased necrosis and sensitivity of the tumor to therapy, but in vitro ATG12-deficient cells displayed enhanced survival in nutrient-rich culture medium. Besides oxygen, delivery of glucose was hampered in hypoxic regions in vivo, which increases the reliance of cells on other carbon sources (e.g., L-glutamine). We observed decreased intracellular L-glutamine levels in ATG12-deficient cells during hypoxia and increased cell killing after L-glutamine depletion, indicating a central role for ATG12 in maintaining L-glutamine homeostasis. Our results demonstrate that ATG12low tumors represent a phenotypically different subtype that, due to the lowered hypoxia tolerance, display a favorable outcome after therapy.Abbreviations: ARCON:accelerated radiotherapy with carbogen and nicotinamide; ATG: autophagy related; BrdUrd: bromodeoxyuridine; CA9/CAIX: carbonic anhydrase 9; HIF1A/HIF1α: hypoxia inducible factor 1 subunit alpha; HNSCC: head and neck squamous cell carcinoma; HPV: human papilloma virus; HR: hazard ratio; MAP1LC3B/LC3B: microtubule associated protein 1 light chain 3 beta; MEF: mouse embryonic fibroblast; mRNA: messenger ribonucleic acid; PCR: polymerase chain reaction; SLC2A1/GLUT1: solute carrier family 2 member 1; TCGA: the Cancer Genome Atlas; TME: tumor microenvironment; UTR: untranslated region; VEGF: vascular endothelial growth factor.


Assuntos
Proteína 12 Relacionada à Autofagia , Glutamina , Neoplasias de Cabeça e Pescoço , Carcinoma de Células Escamosas de Cabeça e Pescoço , Animais , Autofagia/genética , Proteína 12 Relacionada à Autofagia/genética , Fibroblastos/metabolismo , Glutamina/metabolismo , Neoplasias de Cabeça e Pescoço/diagnóstico , Neoplasias de Cabeça e Pescoço/genética , Humanos , Camundongos , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico , Carcinoma de Células Escamosas de Cabeça e Pescoço/genética , Hipóxia Tumoral , Microambiente Tumoral , Fator A de Crescimento do Endotélio Vascular/metabolismo