1.
J Appl Clin Med Phys ; 21(10): 248-252, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32989881

RESUMO

PURPOSE: The geometry of an immobilization device such as a headrest can cause undesired computed tomography (CT) artifacts that may affect both volume definition and dosimetry in radiotherapy of the brain. The purpose of this work was to reduce CT artifacts caused by a standard hard plastic hollow radiotherapy headrest. This was to be achieved through design and prototyping of a custom-made head support. METHODS: A series of CT scans were acquired of both a water phantom and an anthropomorphic head phantom which were resting on custom-made three-dimensional (3D) printed supports. All custom-made supports were made of polylactic acid (PLA) plastic filament and printed by fused deposition modeling (FDM) 3D printing technology. Initial designs were studied with a water phantom using a simplified support with straight and curved shapes both at the edges and as infill patterns. Imaging of a 3D printed clinical prototype was then compared to our standard headrest using an anthropomorphic head phantom. RESULTS: The presence of dark streaks inside both phantoms was seen on the CT images for headrests involving supports with straight shapes at the edges or as infill patterns. Such artifacts were ascribed to the exponential edge-gradient effect (EEGE). No such artifact was observed when the support was designed with a combination of curved edges and infill patterns. CONCLUSION: When developing immobilization accessories for use in CT scanners, more attention could be paid to artifact attenuating design elements. This work illustrates the usefulness of 3D printing in prototyping radiotherapy accessories and solving concrete clinical problems.


Assuntos
Artefatos , Tomografia Computadorizada por Raios X , Cabeça/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Impressão Tridimensional
2.
Acta Oncol ; 58(9): 1275-1282, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31257960

RESUMO

Introduction: Stereotactic radiosurgery (SRS) is a promising treatment option for patients with multiple brain metastases (BM). Recent technical advances have made LINAC based SRS a patient friendly technique, allowing for accurate patient positioning and a short treatment time. Since SRS is increasingly being used for patients with multiple BM, it remains essential that SRS be performed with the highest achievable quality in order to prevent unnecessary complications such as radionecrosis. The purpose of this article is to provide guidance for high-quality LINAC based SRS for patients with BM, with a focus on single isocenter non-coplanar volumetric modulated arc therapy (VMAT). Methods: The article is based on a consensus statement by the study coordinators and medical physicists of four trials which investigated whether patients with multiple BM are better palliated with SRS instead of whole brain radiotherapy (WBRT): A European trial (NCT02353000), two American trials and a Canadian CCTG lead intergroup trial (CE.7). This manuscript summarizes the quality assurance measures concerning imaging, planning and delivery. Results: To optimize the treatment, the interval between the planning-MRI (gadolinium contrast-enhanced, maximum slice thickness of 1.5 mm) and treatment should be kept as short as possible (< two weeks). The BM are contoured based on the planning-MRI, fused with the planning-CT. GTV-PTV margins are minimized or even avoided when possible. To maximize efficiency, the preferable technique is single isocenter (non-)coplanar VMAT, which delivers high doses to the target with maximal sparing of the organs at risk. The use of flattening filter free photon beams ensures a lower peripheral dose and shortens the treatment time. To bench mark SRS treatment plan quality, it is advisable to compare treatment plans between hospitals. Conclusion: This paper provides guidance for quality assurance and optimization of treatment delivery for LINAC-based radiosurgery for patients with multiple BM.


Assuntos
Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundário , Radiocirurgia/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias Encefálicas/diagnóstico por imagem , Ensaios Clínicos como Assunto , Consenso , Meios de Contraste , Gadolínio , Humanos , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal , Posicionamento do Paciente , Seleção de Pacientes , Garantia da Qualidade dos Cuidados de Saúde , Radiocirurgia/normas , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia de Intensidade Modulada/normas , Tomografia Computadorizada por Raios X
3.
J Comput Assist Tomogr ; 41(6): 931-936, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28448423

RESUMO

OBJECTIVE: Dual-energy computed tomography high energy virtual monochromatic images (VMIs) can reduce artifact but suppress iodine attenuation in enhancing tumor. We investigated this trade-off to identify VMI(s) that strike the best balance between iodine detection and artifact reduction. METHODS: The study was performed using an Alderson radiation therapy phantom. Different iodine solutions (based on estimated tumor iodine content in situ using dual-energy computed tomography material decomposition) and different dental fillings were investigated. Spectral attenuation curves and quality index (QI: 1/SD) were evaluated. RESULTS: The relationship between iodine attenuation and QI depends on artifact severity and iodine concentration. For low to average concentration solutions degraded by mild to moderate artifact, the iodine attenuation and QI curves crossed at 95 keV. CONCLUSIONS: High energy VMIs less than 100 keV can achieve modest artifact reduction while preserving sufficient iodine attenuation and could represent a useful additional reconstruction for evaluation of head and neck cancer.


Assuntos
Artefatos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X/métodos , Humanos , Iodo , Estudos Retrospectivos
4.
J Contemp Brachytherapy ; 15(6): 453-464, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38230395

RESUMO

Purpose: The addition of interstitial (IS) needles to intra-cavitary (IC) brachytherapy applicators is associated with improved outcomes in locally advanced cervical cancers involving parametrial tumor extensions. The purpose of this work was to validate a clinical workflow involving 3D-printed caps for a commercial IC split ring applicator that enable using IS needle trajectories tailored to each treatment. Material and methods: A dedicated software module was developed in this work allowing users to design patient-specific IS caps without knowledge of computer-aided design (CAD) software. This software module was integrated to 3D Brachy, a commercial software developed by Adaptiiv Medical Technologies Inc. For validation of the workflow, CAD models of ground truth caps with five IS needle trajectories were designed with Fusion 360™, 3D-printed, assembled with a split ring applicator, and CT-scanned with radio-opaque markers. 3D Brachy was then applied to generate a replica based on trajectories reconstructed from the radio-opaque markers. A comparison between ground truth and replicated IS needle trajectories was done using intersection points with planes at the level of the cervix (z = 0 cm) and a representative needle depth (z = 3 cm). Results: Prototypes of interstitial caps 3D-printed in both BioMed Amber and BioMed Clear SLA resins were tested to be functional both pre- and post-sterilization for IS needles with obliquity angles ≤ 45°. Distance-to-agreement at z = 0 cm and 3 cm as well as deviations in pitch and yaw angles of the five IS needle trajectories were found to have mean values of 3.3 ±2.1 mm, 7.3 ±2.0 mm, 2.9° ±2.3°, and 7.0° ±7.0°, respectively. Conclusions: The clinical workflow for image-guided adaptive cervical cancer brachytherapy using the Montreal split ring applicator was validated.

5.
Anticancer Drugs ; 23(5): 525-33, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22357220

RESUMO

High expression of vascular endothelial growth factor (VEGF) in patients with breast cancer has been associated with a poor prognosis, indicating that VEGF could be linked to the efficacy of chemotherapy and radiotherapy. It has also been suggested that radiation resistance is partly due to tumour cell production of angiogenic cytokines, particularly VEGF receptor (VEGFR). This evidence indicates that inhibition of VEGFR might enhance the radiation response. Sorafenib tosylate (Bay 54-9085) is an oral, small-molecule multikinase inhibitor of several targets including RAF/MEK/ERK MAP kinase signalling, VEGFR-2, VEGFR-3 and platelet-derived growth factor receptor-beta. Sorafenib has shown clinical efficacy in treating solid tumours such as renal cell and hepatocellular carcinomas. However, strategies are yet to be identified to prolong and maximize the anticancer effect of this multikinase inhibitor. The objective of this study was to determine whether a combination of Sorafenib and radiation will enhance the treatment response in vitro and in vivo. Radio-modulating effect of Sorafenib was assessed by performing clonogenic assays. In addition, cell cycle analyses as well as annexin-V apoptosis assays were performed 24 and 48 h after treatment, respectively. To confirm our in-vitro results, tumour growth delay assays were performed. Our results showed a strong and supra-additive antitumour effect of radiation combined with Sorafenib in vitro (dose enhancement factor of 1.76). The combined therapy demonstrated a strong and significant G2/M cell cycle arrest (combined treatment vs. irradiated alone: P<0.0008). Moreover, annexin-V staining showed a significant increase in the level of apoptosis (combined treatment vs. irradiated alone: P<0.0004). Study of the syngeneic model demonstrated the superior potency of the Sorafenib combined with radiotherapy. Our results demonstrate that higher antitumour activity can be achieved when radiation and Sorafenib are combined.


Assuntos
Antineoplásicos/uso terapêutico , Benzenossulfonatos/uso terapêutico , Ciclo Celular , Raios gama/uso terapêutico , Neoplasias Mamárias Experimentais , Inibidores de Proteínas Quinases/uso terapêutico , Piridinas/uso terapêutico , Animais , Antineoplásicos/administração & dosagem , Antineoplásicos/farmacologia , Apoptose/efeitos dos fármacos , Apoptose/efeitos da radiação , Benzenossulfonatos/administração & dosagem , Benzenossulfonatos/farmacologia , Western Blotting , Ciclo Celular/efeitos dos fármacos , Ciclo Celular/efeitos da radiação , Divisão Celular/efeitos dos fármacos , Divisão Celular/efeitos da radiação , Linhagem Celular Tumoral , Terapia Combinada , Feminino , Citometria de Fluxo , Fase G2/efeitos dos fármacos , Fase G2/efeitos da radiação , Neoplasias Mamárias Experimentais/tratamento farmacológico , Neoplasias Mamárias Experimentais/radioterapia , Camundongos , Camundongos Endogâmicos BALB C , Niacinamida/análogos & derivados , Compostos de Fenilureia , Inibidores de Proteínas Quinases/administração & dosagem , Inibidores de Proteínas Quinases/farmacologia , Piridinas/administração & dosagem , Piridinas/farmacologia , Sorafenibe , Ensaios Antitumorais Modelo de Xenoenxerto
6.
Med Phys ; 39(8): 4850-7, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22894411

RESUMO

PURPOSE: Despite numerous advantages of radiochromic film dosimeter (high spatial resolution, near tissue equivalence, low energy dependence) to measure a relative dose distribution with film, one needs to first measure an absolute dose (following previously established reference dosimetry protocol) and then convert measured absolute dose values into relative doses. In this work, we present result of our efforts to obtain a functional form that would linearize the inherently nonlinear dose-response curve of the radiochromic film dosimetry system. METHODS: Functional form [ζ = (-1)[middle dot]netOD((2∕3))∕ln(netOD)] was derived from calibration curves of various previously established radiochromic film dosimetry systems. In order to test the invariance of the proposed functional form with respect to the film model used we tested it with three different GAFCHROMIC™ film models (EBT, EBT2, and EBT3) irradiated to various doses and scanned on a same scanner. For one of the film models (EBT2), we tested the invariance of the functional form to the scanner model used by scanning irradiated film pieces with three different flatbed scanner models (Epson V700, 1680, and 10000XL). To test our hypothesis that the proposed functional argument linearizes the response of the radiochromic film dosimetry system, verification tests have been performed in clinical applications: percent depth dose measurements, IMRT quality assurance (QA), and brachytherapy QA. RESULTS: Obtained R(2) values indicate that the choice of the functional form of the new argument appropriately linearizes the dose response of the radiochromic film dosimetry system we used. The linear behavior was insensitive to both film model and flatbed scanner model used. Measured PDD values using the green channel response of the GAFCHROMIC™ EBT3 film model are well within ±2% window of the local relative dose value when compared to the tabulated Cobalt-60 data. It was also found that criteria of 3%∕3 mm for an IMRT QA plan and 3%∕2 mm for a brachytherapy QA plan are passing 95% gamma function points. CONCLUSIONS: In this paper, we demonstrate the use of functional argument to linearize the inherently nonlinear response of a radiochromic film based reference dosimetry system. In this way, relative dosimetry can be conveniently performed using radiochromic film dosimetry system without the need of establishing calibration curve.


Assuntos
Dosimetria Fotográfica/métodos , Dosimetria Fotográfica/normas , Algoritmos , Braquiterapia/métodos , Calibragem , Relação Dose-Resposta à Radiação , Humanos , Modelos Lineares , Imagens de Fantasmas , Doses de Radiação , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Reprodutibilidade dos Testes , Software , Interface Usuário-Computador , Água/química
7.
Med Phys ; 38(9): 5119-29, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21978057

RESUMO

PURPOSE: The authors applied 2D reference dosimetry protocol for dose measurements using XR-QA radiochromic film model during diagnostic computed tomography (CT) examinations carried out on patients and humanoid Rando phantom. METHODS: Response of XR-QA model GAFCHROMIC™ film reference dosimetry system was calibrated in terms of Air-Kerma in air. Four most commonly used CT protocols were selected on their CT scanner (GE Lightspeed VCT 64), covering three anatomical sites (head, chest, and abdomen). For each protocol, 25 patients ongoing planned diagnostic CT examination were recruited. Surface dose was measured using four or eight film strips taped on patients' skin and on Rando phantom. Film pieces were scanned prior to and after irradiation using Epson Expression™ 10000XL document scanner. Optical reflectance of the unexposed film piece was subtracted from exposed one to obtain final net reflectance change, which is subsequently converted to dose using previously established calibration curves. RESULTS: The authors' measurements show that body skin dose variation has a sinusoidal pattern along the scanning axis due to the helical movement of the x-ray tube, and a comb pattern for head dose measurements due to its axial movement. Results show that the mean skin dose at anterior position for patients is (51 ± 6) mGy, (29 ± 11) mGy, (45 ± 13) mGy and (38 ± 20) mGy for head, abdomen, angio Abdomen, and chest and abdomen protocol (UP position), respectively. The obtained experimental dose length products (DLP) show higher values than CT based DLP taken from the scanner console for body protocols, but lower values for the head protocol. Internal dose measurements inside the phantom's head indicate nonuniformity of dose distribution within scanned volume. CONCLUSIONS: In this work, the authors applied an Air-Kerma in air based radiochromic film reference dosimetry protocol for in vivo skin dose measurements. In this work, they employed green channel extracted from the scanned RGB image for dose measurements in the range from 0 to 200 mGy. Measured skin doses and corresponding DLPs were higher than DLPs provided by the CT scanner manufacturer as they were measured on patients' skin.


Assuntos
Dosimetria Fotográfica/métodos , Dosimetria Fotográfica/normas , Tomografia Computadorizada por Raios X/métodos , Calibragem , Humanos , Imagens de Fantasmas , Doses de Radiação , Padrões de Referência , Incerteza
8.
Med Phys ; 38(11): 6074-83, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22047372

RESUMO

PURPOSE: A radiochromic film based dosimetry system for high dose rate (HDR) Iridium-192 brachytherapy source was described. A comparison between calibration curves established in water and Solid Water™ was provided. METHODS: Pieces of EBT-2 model GAFCHROMIC™ film were irradiated in both water and Solid Water™ with HDR (192)Ir brachytherapy source in a dose range from 0 to 50 Gy. Responses of EBT-2 GAFCHROMIC™ film were compared for irradiations in water and Solid Water™ by scaling the dose between media through Monte Carlo calculated conversion factor for both setups. To decrease uncertainty in dose delivery due to positioning of the film piece with respect to the radiation source, traceable calibration irradiations were performed in a parallel-opposed beam setup. RESULTS: The EBT-2 GAFCHROMIC™ film based dosimetry system described in this work can provide an overall one-sigma dose uncertainty of 4.12% for doses above 1 Gy. The ratio of dose delivered to the sensitive layer of the film in water to the dose delivered to the sensitive layer of the film in Solid Water™ was calculated using Monte Carlo simulations to be 0.9941 ± 0.0007. CONCLUSIONS: A radiochromic film based dosimetry system using only the green color channel of a flatbed document scanner showed superior precision if used alone in a dose range that extends up to 50 Gy, which greatly decreases the complexity of work. In addition, Solid Water™ material was shown to be a viable alternative to water in performing radiochromic film based dosimetry with HDR (192)Ir brachytherapy sources.


Assuntos
Dosimetria Fotográfica/métodos , Radioisótopos de Irídio/uso terapêutico , Radioterapia/métodos , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Incerteza
9.
Viruses ; 13(9)2021 09 02.
Artigo em Inglês | MEDLINE | ID: mdl-34578334

RESUMO

3D-printed alternatives to standard flocked swabs were rapidly developed to provide a response to the unprecedented and sudden need for an exponentially growing amount of diagnostic tools to fight the COVID-19 pandemic. In light of the anticipated shortage, a hospital-based 3D-printing platform was implemented in our institution for the production of swabs for nasopharyngeal and oropharyngeal sampling based on the freely available, open-source design provided to the community by University of South Florida's Health Radiology and Northwell Health System teams as a replacement for locally used commercial swabs. Validation of our 3D-printed swabs was performed with a head-to-head diagnostic accuracy study of the 3D-printed "Northwell model" with the cobas PCR Media® swab sample kit. We observed an excellent concordance (total agreement 96.8%, Kappa 0.936) in results obtained with the 3D-printed and flocked swabs, indicating that the in-house 3D-printed swab could be used reliably in the context of a shortage of flocked swabs. To our knowledge, this is the first study to report on autonomous hospital-based production and clinical validation of 3D-printed swabs.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/virologia , SARS-CoV-2 , Teste para COVID-19/instrumentação , Gerenciamento Clínico , Humanos , Nasofaringe/virologia , Reação em Cadeia da Polimerase/métodos , Impressão Tridimensional , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Manejo de Espécimes/métodos
10.
Med Phys ; 37(3): 1083-92, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20384244

RESUMO

PURPOSE: A common approach for dose assessment during cone beam computed tomography (CBCT) acquisition is to use thermoluminescent detectors for skin dose measurements (on patients or phantoms) or ionization chamber (in phantoms) for body dose measurements. However, the benefits of a daily CBCT image acquisition such as margin reduction in planning target volume and the image quality must be weighted against the extra dose received during CBCT acquisitions. METHODS: The authors describe a two-dimensional reference dosimetry technique for measuring dose from CBCT scans using the on-board imaging system on a Varian Clinac-iX linear accelerator that employs the XR-QA radiochromic film model, specifically designed for dose measurements at low energy photons. The CBCT dose measurements were performed for three different body regions (head and neck, pelvis, and thorax) using humanoid Rando phantom. RESULTS: The authors report on both surface dose and dose profiles measurements during clinical CBCT procedures carried out on a humanoid Rando phantom. Our measurements show that the surface doses per CBCT scan can range anywhere between 0.1 and 4.7 cGy, with the lowest surface dose observed in the head and neck region, while the highest surface dose was observed for the Pelvis spot light CBCT protocol in the pelvic region, on the posterior side of the Rando phantom. The authors also present results of the uncertainty analysis of our XR-QA radiochromic film dosimetry system. CONCLUSIONS: Radiochromic film dosimetry protocol described in this work was used to perform dose measurements during CBCT acquisitions with the one-sigma dose measurement uncertainty of up to 3% for doses above 1 cGy. Our protocol is based on film exposure calibration in terms of "air kerma in air," which simplifies both the calibration procedure and reference dosimetry measurements. The results from a full Monte Carlo investigation of the dose conversion of measured XR-QA film dose at the surface into dose to water (or water kerma) at the surface of the phantom indicate that, for typical beam qualities used in CBCT, this conversion can be approximated by simple mass-energy absorption coefficient ratios water-to-air.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Dosimetria Fotográfica/normas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Radioterapia Conformacional/normas , Canadá , Humanos , Fótons/uso terapêutico , Dosagem Radioterapêutica , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Med Phys ; 37(7): 3687-93, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20831076

RESUMO

PURPOSE: The authors present results of the measurements on the impact of radiochromic film immersion in water. The impact of film piece size, initial optical density, postimmersion waiting time prior to scanning, and the time film was kept in water has been investigated. The authors also investigated the pathways of water penetration into the film during the film immersion in water. METHODS: To study the impact of water immersion on change in optical density, the authors used various sizes of the latest EBT-2 model GAFCHROMICTM film: 2 x 2, 4 x 4, and 8 x 8 in.2. In addition, to test any existing dependence of the film's optical density on water diffusion, the authors used two sets of films: Unexposed (0 Gy) and film pieces exposed to a dose of 3 Gy. Times that film pieces were left in water ranged from 30 min to 24 h, and once the film was permanently removed from water, the authors also studied the impact of the scanning time (deltat) that ranged from 0 (films scanned right after removal from water) to 72 h postimmersion. RESULTS: While the penetration depth can reach as much as 9 mm around the edges of the EBT-2 GAFCHROMIC film, the anticipated dose error due to the change in optical density due to the water immersion appears to be negligible for the short immersions of the order of 30 min. However, as the immersion time increases, the anticipated dose error may reach 22 cGy on a 2 x 2 in.2 piece of film, which corresponds to 7% dose error at 3 Gy of measured dose. CONCLUSIONS: In this work, the authors report on an undoubted impact of radiochromic film immersion in water on the measured change in optical density, which may lead to systematic errors in dose measurements if the film is kept in water for longer periods of time. The magnitude of the impact depends on many parameters: Size of the film piece, initial optical density, postimmersion waiting time prior to scanning (defined by the current radiochromic film dosimetry protocol in. place), and the time film was kept in water. The authors also suggested various approaches in correcting for the change in netOD due to water penetration into the film, but the authors believe that the use of the control film piece would be the most appropriate.


Assuntos
Radiometria/métodos , Água , Absorção , Imersão , Fenômenos Ópticos , Análise Espectral
12.
Med Phys ; 37(5): 2207-14, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20527554

RESUMO

PURPOSE: One of the major drawbacks of the current radiochromic film dosimetry protocols is the postirradiation waiting time. In this article, the authors study the postirradiation time evolution of the absorption spectrum of radiochromic EBT-2 GAFCHROMIC film model. METHODS: Postirradiation scanning times range from 3 min to 5 days and a dose range extends from 0 to 6 Gy. The authors compare the results of absorption spectra measurements for the latest GAFCHROMIC EBT-2 film model to the absorption spectra of the previous EBT GAFCHROMIC film model. The authors also describe a method that can establish the time error constraints on the postirradiation scanning time that will still provide an acceptable dose error for clinical applications if the protocol employing the shorter postirradiation scanning time is implemented in the clinic. RESULTS: The two film models experience the very same dose change in net absorbance with sensitivity of the latest EBT-2 model GAFCHROMIC film being slightly lower than its predecessor. The authors show that for two postirradiation scanning times of 30 min and 24 h, the 1% dose error can be achieved if the scanning time window is less than +/- 5 min and +/- 2 h, respectively. CONCLUSIONS: By comparing the resultant change in net absorbance between the latest EBT-2 and previous EBT GAFCHROMIC film models, the authors conclude that the addition of the yellow marker dye to the sensitive layer does not affect dosimetric properties of the latest film model. The authors also describe a procedure by which one can establish an acceptable time window around chosen postirradiation scanning time protocol that would provide an acceptable dose error for practical purposes.


Assuntos
Dosimetria Fotográfica/métodos , Modelos Teóricos , Absorção , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Análise Espectral , Fatores de Tempo
13.
Med Phys ; 47(7): 3103-3112, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32198933

RESUMO

INTRODUCTION: Trajectory-based volumetric modulated arc therapy (tr-VMAT) treatment plans enable the option for noncoplanar delivery yielding steeper dose gradients and increased sparing of critical structures compared to conventional treatment plans. The addition of translational couch motion to shorten the effective source-to-axis distance (SAD) may result in improved delivery precision and an increased effective dose rate. In this work, tr-VMAT treatment plans using a noncoplanar "baseball stitch" trajectory were implemented, applied to patients presented with cranial targets, and compared to the clinical treatment plans. METHODS: A treatment planning workflow was implemented: (a) beamlet doses were calculated for control points defined along a baseball stitch trajectory using a collapsed-cone convolution-superposition algorithm; (b) VMAT treatment plans were optimized using the column generation approach; (c) a final dose distribution was calculated in Varian Eclipse using the analytical anisotropic algorithm by importing the optimized treatment plan parameters. Tr-VMAT plans were optimized for ten patients presented with cranial targets at both standard and shortened SAD, and compared to the clinical treatment plans through isodose distributions, dose-volume histograms, and dosimetric indices. The control point specifications of the optimized tr-VMAT plans were used to estimate the delivery time. RESULTS: The optimized tr-VMAT plans with both shortened and standard SAD delivery yielded a comparable plan quality to the clinical treatment plans. A statistically significant benefit was observed for dose gradient index and monitor unit efficiency for shortened SAD tr-VMAT plans, while improved target volume conformity was observed for the clinical treatment plan (P ≤ 0.05). A clear dosimetric benefit was not demonstrated between tr-VMAT delivery at shortened SAD compared to standard SAD, but shortened SAD delivery yielded a fraction size-dependent reduction in the estimated delivery time. CONCLUSION: The implementation of "baseball stitch" tr-VMAT treatment plans to patients presented with cranial targets demonstrated comparable plan quality to clinical treatment plans. The delivery at shortened SAD produced a fraction size-dependent decrease in estimated delivery time.


Assuntos
Radioterapia de Intensidade Modulada , Algoritmos , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Crânio
14.
Phys Med ; 76: 7-15, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32569954

RESUMO

Owing to its short computation time and simplicity, the Ray-Tracing algorithm (RAT) has long been used to calculate dose distributions for the CyberKnife system. However, it is known that RAT fails to fully account for tissue heterogeneity and is therefore inaccurate in the lung. The aim of this study is to make a dosimetric assessment of 219 non-small cell lung cancer CyberKnife plans by recalculating their dose distributions using an independent Monte Carlo (MC) method. For plans initially calculated by RAT without heterogeneity corrections, target coverage was found to be significantly compromised when considering MC doses. Only 35.4% of plans were found to comply to their prescription doses. If the normal tissue dose limits were respected in the treatment planning dose, the MC recalculated dose did not exceed these limits in over 97% of the plans. Comparison of RAT and recalculated-MC doses confirmed the overestimation of RAT doses observed in previous studies. An inverse correlation between the RAT/MC dose ratio and the target size was also found to be statistically significant (p<10-4), consistent with other studies. In addition, the inaccuracy and variability in target coverage incurred from dose calculations using RAT without heterogeneity corrections was demonstrated. On average, no clinically relevant differences were observed between MC-calculated dose-to-water and dose-to-medium for all tissues investigated (⩽1%). Patients receiving a dose D95% larger than 119 Gy in EQD210 (or ≈52 Gy in 3 fractions) as recalculated by MC were observed to have significantly superior loco-regional progression-free survival rates (p=0.02) with a hazard ratio of 3.45 (95%CI: 1.14-10.5).


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Radiocirurgia , Procedimentos Cirúrgicos Robóticos , Algoritmos , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Humanos , Pulmão , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Método de Monte Carlo , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
15.
Brachytherapy ; 17(1): 234-243, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29102741

RESUMO

PURPOSE: The Papillon technique using 50-kVp soft X-rays to treat rectal adenocarcinomas was developed and clinically implemented in the 1960s. We describe differences between accurate dosimetry and clinical implementation of this technique that is extending from its very inception to date. METHODS AND MATERIALS: A renaissance of the Papillon technique occurred with two recently introduced 50-kVp systems: Papillon+ by Ariane and a custom-made rectal applicator (consisting of a surface applicator inserted into a proctoscope) by iCAD's Xoft Axxent Electronic Brachytherapy (eBT) System (iCad, Inc., Sunnyvale, CA). In contrast to the initial design, we investigated the impact of introducing a plastic lid, which would provide more reproducible and more accurate dose delivery across the rectal adenocarcinoma patient population. We use both parallel-plate chamber and radiochromic film dosimeters to determine differences in basic dosimetry characteristics (beam half-value layers, outputs, percent depth doses, and profiles) between the Xoft Electronic Brachytherapy rectal applicator system with and without the plastic lid in place. RESULTS: Compared to the open-cone applicator, the proposed applicator with the plastic lid produces a slightly harder (more penetrating) beam quality (half-value layer of 1.4 vs. 1.3-mm Al), but with reduced output (by 33%), and a slightly broader beam with flatness not worse than 3% and symmetry not worse than 2%. CONCLUSIONS: In addition to characterizing beam properties modified by the possible introduction of the plastic cap, we also pointed out and addressed misconceptions in the use of radiochromic films for dose measurements at low-energy photon beams.


Assuntos
Adenocarcinoma/radioterapia , Braquiterapia/instrumentação , Dosimetria Fotográfica/instrumentação , Neoplasias Retais/radioterapia , Braquiterapia/métodos , Desenho de Equipamento , Humanos , Física , Dosagem Radioterapêutica
16.
Brachytherapy ; 16(5): 1065-1072, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28735877

RESUMO

PURPOSE: Current high-dose-rate brachytherapy skin treatments with the Freiburg flap (FF) applicator are planned with treatment planning systems based on the American Association of Physicists in Medicine TG-43 data sets, which assume full backscatter conditions in dose calculations. The aim of this work is to describe an experimental method based on radiochromic film dosimetry to evaluate dose calculation accuracy during surface treatments with the FF applicator at different depths and bolus thicknesses. METHODS AND MATERIALS: Absolute doses were measured using a reference EBT3 radiochromic film dosimetry system within a Solid Water phantom at different depths (0, 0.5, 1, 2, and 3 cm) with respect to the phantom surface. The impact of bolus (up to 3-cm thickness) placed on top of the applicator was investigated for two clinical loadings created using Oncentra MasterPlan: 5 cm × 5 cm and 11 cm × 11 cm. RESULTS: For smaller loading and depths beyond 2 cm and for larger loading and depths beyond 1 cm, the dose difference was less than 3% (±4%). At shallower depths, differences of up to 6% (±4%) at the surface were observed if no bolus was added. The addition of 2-cm bolus for the smaller loading and 1 cm for larger loading minimized the difference to less than 3% (±4%). CONCLUSIONS: For typical FF applicator loading sizes, the actual measured dose was 6% (±4%) lower at the skin level when compared with TG-43. Additional bolus above the FF was shown to decrease the dose difference. The consideration of change in clinical practice should be carefully investigated in light of clinical reference data.


Assuntos
Braquiterapia/instrumentação , Braquiterapia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Cutâneas/radioterapia , Dosimetria Fotográfica , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica , Água
17.
Phys Med Biol ; 51(8): N157-61, 2006 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-16585837

RESUMO

A program was developed, RadSim, which can be used to simulate certain individual interactions of photons, electrons, positrons and alpha particles with a single atom for educational purposes. The program can be run in two modes: manual and simulated. In the manual mode, an individual particle undergoing a specified interaction with a target atom can be simulated, which essentially comes down to a graphical evaluation of kinematic equations. In the simulated mode, a preset number of identical particles are allowed to undergo a specified interaction type with a target atom. The exit channel of the interaction is sampled from probability distributions using Monte Carlo methods. The incoming and outgoing particles are visualized and the frequency distribution of the kinematic variables of the exit channel is displayed graphically. It has to be emphasized that RadSim was mainly developed for educational purposes.


Assuntos
Instrução por Computador/métodos , Física Médica/educação , Transferência Linear de Energia , Modelos Químicos , Física Nuclear/educação , Software , Interface Usuário-Computador , Simulação por Computador
19.
Med Phys ; 32(1): 286-98, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15719980

RESUMO

Recent work has shown that there is significant uncertainty in measuring build-up doses in mega-voltage photon beams especially at high energies. In this present investigation we used a phantom-embedded extrapolation chamber (PEEC) made of Solid Water to validate Monte Carlo (MC)-calculated doses in the dose build-up region for 6 and 18 MV x-ray beams. The study showed that the percentage depth ionizations (PDIs) obtained from measurements are higher than the percentage depth doses (PDDs) obtained with Monte Carlo techniques. To validate the MC-calculated PDDs, the design of the PEEC was incorporated into the simulations. While the MC-calculated and measured PDIs in the dose build-up region agree with one another for the 6 MV beam, a non-negligible difference is observed for the 18 MV x-ray beam. A number of experiments and theoretical studies of various possible effects that could be the source of this discrepancy were performed. The contribution of contaminating neutrons and protons to the build-up dose region in the 18 MV x-ray beam is negligible. Moreover, the MC calculations using the XCOM photon cross-section database and the NIST bremsstrahlung differential cross section do not explain the discrepancy between the MC calculations and measurement in the dose build-up region for the 18 MV. A simple incorporation of triplet production events into the MC dose calculation increases the calculated doses in the build-up region but does not fully account for the discrepancy between measurement and calculations for the 18 MV x-ray beam.


Assuntos
Aceleradores de Partículas , Radiometria/métodos , Radioterapia de Alta Energia/métodos , Dosimetria Termoluminescente/métodos , Elétrons , Íons , Modelos Estatísticos , Método de Monte Carlo , Nêutrons , Fótons , Prótons , Dosagem Radioterapêutica , Software , Água , Raios X
20.
Phys Med Biol ; 50(15): 3555-69, 2005 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-16030382

RESUMO

Kilovolt x-rays are clearly suboptimal compared to MV photon beams for radiotherapy of deep-seated tumours because of the increased attenuation in tissue, causing a rapid dose fall-off. This picture could change drastically when tumours can be labelled with contrast medium, containing high atomic number elements. This causes a significant dose enhancement to the tumour by exploiting the high cross sections for the photo-electric effect for kV x-rays. In this work, we have investigated the dosimetric and microdosimetric characteristics of kV contrast-enhanced radiation therapy (CERT) for different photon energies, contrast-medium concentrations and types (I and Gd). Two idealized patient treatment plans (head and lung) for irradiation with CT-arc beams were calculated. It is shown that the dose enhancement in tumours can be highly significant (up to about sixfold for realistic 80-120 kVp x-ray spectra and an iodine concentration of 50 mg ml-1) but that dose homogeneity in the tumour depends on photon energy, contrast-medium concentration and type, and irradiation scheme. An attempt to optimize the irradiation scheme is discussed. The microdosimetric study of the dose mean lineal energy shows that radiation quality changes in the contrast-medium-labelled region compared to homogeneous tissue are fairly small and limited to 10%. It is concluded that kV-CERT is a promising radiotherapy technique, provided contrast medium can be delivered reliably to tumours.


Assuntos
Meios de Contraste/uso terapêutico , Modelos Biológicos , Neoplasias/radioterapia , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia/métodos , Terapia por Raios X/métodos , Carga Corporal (Radioterapia) , Simulação por Computador , Humanos , Doses de Radiação , Dosagem Radioterapêutica , Eficiência Biológica Relativa , Resultado do Tratamento