Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
J Endovasc Ther ; : 15266028241230943, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38380529

RESUMO

PURPOSE: The aim of this study was to evaluate the radiation dose, image quality, and the potential of virtual monoenergetic imaging (VMI) reconstructions of high-pitch computed tomography angiography (CTA) of the thoracoabdominal aorta on a dual-source photon-counting detector-CT (PCD-CT) in comparison with an energy-integrating detector-CT (EID-CT), with a special focus on low-contrast attenuation. METHODS: Consecutive patients being referred for an electrocardiogram (ECG)-gated, high-pitch CTA of the thoracoabdominal aorta prior to transcatheter aortic valve replacement (TAVR), and examined on the PCD-CT, were included in this prospective single-center study. For comparison, a retrospective patient group with ECG-gated, high-pitch CTA examinations of the thoracoabdominal aorta on EID-CT with a comparable scan protocol was matched for gender, body mass index, height, and age. Virtual monoenergetic imaging reconstructions from 40 to 120 keV were performed. Enhancement and noise were measured in 7 vascular segments and the surrounding air as mean and standard deviation of CT values. The radiation dose was noted and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Finally, a subgroup analysis was performed, comparing VMI reconstructions from 40 keV to 70 keV in patients with at least a 50% decrease in contrast attenuation between the ascending aorta and femoral arteries. RESULTS: Fifty patients (mean age 77.0±14.5 years; 31 women) were included. The radiation dose was significantly lower on the PCD-CT (4.2±1.4 vs. 7.2±2.2 mGy; p<0.001). With increasing keV, vascular noise, SNR, and CNR decreased. Intravascular attenuation was significantly higher on VMI at levels from 40 to 65, compared with levels of 120 keV (p<0.01 and p<0.005, respectively). On the PCD-CT, SNR was significantly higher in keV levels 40 and 70 (all p<0.001), and CNR was higher at keV levels 40 and 45 (each p<0.001), compared with scans on the EID-CT. At VMI ≤60 keV, image noise was also significantly higher than that in the control group. The subgroup analysis showed a drastically improved diagnostic performance of the low-keV images in patients with low-contrast attenuation. CONCLUSION: The ECG-gated CTA of the thoracoabdominal aorta in high-pitch mode on PCD-CT have significantly lower radiation dose and higher objective image quality than EID-CT. In addition, low-keV VMI can salvage suboptimal contrast studies, further reducing radiation dose by eliminating the need for repeat scans. CLINICAL IMPACT: ECG-gated CT-angiographies of the thoracoabdominal aorta can be acquired with a lower radtiation dose and a better image quality by using a dual-source photon-countinge detector CT. Furthermore, the inherent spectral data offers the possiblity to improve undiagnostic images and thus saves the patient from further radiation and contrast application.

2.
Eur J Radiol ; 158: 110645, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36525704

RESUMO

PURPOSE: To assess the overall imaging performance (radiation dose and image quality) of a photon-counting detector CT (PCD-CT) in comparison with a state-of-the-art energy-integrating detector CT (EID-CT) in run-off CTAs. METHODS: Consecutive patients who underwent run-off CTA on a PCD-CT were included (PCD-CT cohort). A retrospective cohort of patients who had undergone run-off CTA on an EID-CT was matched for gender, body mass index, height, and age (EID-CT cohort). Virtual monoenergetic imaging (VMI) reconstructions for various keV settings (40-120 keV) were generated. CT values and noise were semiautomatically measured for 13 vascular segments of the abdomen, pelvis, and lower extremities. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated for each segment. Subjective image quality was evaluated by two radiologists along the dimensions 'vessel attenuation', 'vessel sharpness', and 'overall image quality' using 5-point Likert scales. RESULTS: Forty patients (age 70.9 ± 9.8 years; 14 women) were included in the PCD-CT cohort and matched with a corresponding number of EID-CT patients. Overall, there was an inverse correlation of signal and noise but also of SNR and CNR with keV levels used for VMI reconstructions. SNR and CNR in the 40 - 60 keV range exceeded EID-CT levels significantly. Subjective image quality was substantially higher at lower keV levels and showed no significant difference to EID-CT. CONCLUSION: Low keV VMI reconstructions of run-off CTA scans on a PCD-CT result in substantially higher SNR and CNR than 80 kVp and 100 kVp EID-CT acquisitions with equal subjective image quality.


Assuntos
Angiografia por Tomografia Computadorizada , Tomografia Computadorizada por Raios X , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Razão Sinal-Ruído , Abdome
4.
Appl Opt ; 10(1): 24-7, 1971 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-20094384

RESUMO

We propose a novel instrument for automobile exhaust analysis based on a Hadamard-transform spectrometer, which would be able to make accurate measurements of the concentration of several pollutants simultaneously, would be operated by unskilled personnel, and would complete a measurement scan in less than 1 sec.

5.
Appl Opt ; 10(3): 510-4, 1971 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-20094481

RESUMO

A 255-slot Hadamard-transform spectrometer is described which has experimentally verified the multiplex advantage in signal-to-noise ratio previously predicted for this class of spectrometer.

6.
Appl Opt ; 9(6): 1392-5, 1970 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-20076390

RESUMO

We point out the applicability of optical Hadamard-transform coding to detector-noise-limited image scanning and give approximate signal-to-noise ratio gains over conventional point-by-point scanning for several whole-image multiplex scanning schemes.

7.
Appl Opt ; 7(11): 2205-9, 1968 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-20068968

RESUMO

A new method for optically encoding the spectral output of multislit spectrometers is proposed. It is based on sequential measurements of the total intensity of light in combinations of selected spectral bands. The resulting encoded optical information is obtained as a set of simultaneous linear algebraic equations, and spectrum reconstruction is accomplished through the use of matrix inversion techniques. This encoding method avoids the problems associated with frequency transform encoding, because it is not based on the usual Fourier or Fresnel transforms. Rather, it makes use of the theory of simultaneous linear algebraic equations.

8.
Ear Hear ; 25(3): 230-41, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15179114

RESUMO

OBJECTIVE: The aim of this study was to investigate the benefits of the preprocessing scheme "Adaptive Dynamic Range Optimization" (ADRO) in children using Nucleus cochlear implants. Previous research with adults indicates improved speech perception in quiet and improved sound quality in everyday listening environments with the ADRO scheme. DESIGN: Children were given 4 wk of take-home experience with ADRO, with a minimum of 2 wk in which ADRO was "locked-in." After 1 wk of ADRO use and again after 4 wk of ADRO use, Bench-Kowal-Bamford (BKB) sentence perception in quiet at a low input level of 50 dB SPL (unweighted root mean square) and sentence perception in noise were compared with the child's everyday (Standard) program and the ADRO program. Children also rated the loudness of a variety of environmental sounds and indicated which program provided the best hearing in a variety of everyday listening situations. RESULTS: On average, BKB sentence perception in quiet at 50 dB SPL was significantly better with the ADRO program compared with the Standard program. The group mean improvement was 8.60%. Similarly, group mean scores for BKB sentences presented at 65 dB SPL in multitalker babble were significantly higher with the ADRO program (an improvement of 6.87%). The ADRO program was the preferred program in 46% of the listening situations, whereas the Standard program was preferred in 26% of situations. Everyday sounds were not unacceptably loud with ADRO. CONCLUSIONS: There was an ADRO benefit for this group of children in quiet and in noise. These findings suggest that young children would benefit from the ADRO programming option being locked in along with other processor settings in the SPrint processor once their MAP levels have stabilized. Some older children and teenagers may choose to use ADRO selectively for specific listening situations.


Assuntos
Implantes Cocleares , Perda Auditiva/terapia , Percepção da Fala , Estimulação Acústica/instrumentação , Adolescente , Adulto , Análise de Variância , Criança , Humanos , Satisfação do Paciente , Ajuste de Prótese/métodos , Análise de Regressão , Medida da Produção da Fala , Inquéritos e Questionários , Resultado do Tratamento
9.
Am Ind Hyg Assoc J ; 60(2): 191-4, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10222569

RESUMO

In response to concerns about lead-based paint (LBP) in an 85-year old high school, an evaluation was conducted to determine whether a lead exposure hazard existed for adult school staff. Deteriorating LBP was present on walls and ceilings throughout the school. At the time of the evaluation, abatement of LBP had been completed in approximately one-third of the school. One-hundred eighteen wipe samples for lead dust were collected from floors, teachers' desks, and interior window sills. Areas selected for sampling were based on the work location of the 45 participants providing blood for lead analysis. Wipe samples from hands were collected from all participants. The geometric means (GMs) for lead dust loadings on sills in unabated rooms (n = 23) and abated rooms (n = 16) were 342 and 102 micrograms/ft2, respectively. Nine sills in unabated rooms and one sill in an abated room exceeded the Housing and Urban Development (HUD) guidelines (500 micrograms/ft2 lead) for residential housing following abatement activity. GMs for lead loadings on floors in unabated rooms (n = 26) and abated rooms (n = 14) were 136 and 70 micrograms/ft2 lead, respectively. Seventeen floor samples from unabated rooms and 3 samples from abated rooms exceeded HUD guidelines (100 micrograms/ft2 lead). The GM blood lead level (BLL) was 2.2 micrograms/dL (range: 0.6-5.6 micrograms/dL), similar to that of the general U.S. population. Despite peeling LBP and significant lead dust loadings, a hazard from LBP was not found for staff at the school. There were no relationships between surface lead and hand lead, BLL and abatement status of assigned work area, or BLL and hand lead.


Assuntos
Poeira , Monitoramento Ambiental , Docentes , Chumbo/análise , Exposição Ocupacional/análise , Pintura , Instituições Acadêmicas , População Urbana , Adulto , Idoso , Monitoramento Ambiental/métodos , Feminino , Humanos , Masculino , Concentração Máxima Permitida , Pessoa de Meia-Idade
10.
Appl Opt ; 15(6): 1595-609, 1976 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-20165224

RESUMO

An imager and a spectrometric imager, which achieve multiplexing by the use of binary optical encoding masks, have been built and tested. The masks are based on orthogonal, pseudorandom digital codes derived from Hadamard matrices. The spatial (and/or spectral) data are therefore obtained in the form of a Hadamard transform of the spatial (and/or spectral) scene; computer algorithms are used to decode the data and reconstruct images of the original scene. The hardware, algorithms processing and display facility are described. A number of spatial and spatial/spectral images, obtained in the laboratory, are presented. We present an analysis of the situations for which the multiplex advantage may be gained and of the limitations of the technique. Potential applications of the spectrometric imager are discussed. The spectrometric imager is covered by U.S. Patent 3,720,469 assigned to Spectral Imaging Inc., Concord, Mass.

11.
Ear Hear ; 23(1 Suppl): 18S-27S, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11885571

RESUMO

OBJECTIVE: The main objective of this study was to assess whether speech perception and speech production in children using the Nucleus 24 cochlear implant system improved with a change in speech processing strategy from the SPEAK to the Advanced Combination Encoder (ACE) strategy. The major difference between the two strategies is that ACE uses a higher stimulation rate (in this study the stimulation rate was 900 Hz per channel) compared with the SPEAK strategy, where the stimulation rate is 250 Hz per channel. Information also was obtained regarding the adjustment period after conversion to the ACE strategy. DESIGN: An ABA experimental design was used where scores were initially obtained using the SPEAK strategy' (in the initial A time interval), and subsequently performance was assessed using the ACE strategy (B time interval) and then again with the SPEAK strategy (second A time interval). The duration of the B interval was 10 wk, and the duration for the second A interval was 4 wk. Seven children aged between 9 and 16 yr who had at least 6 mo experience with the SPEAK strategy participated. Open-set monosyllabic CNC word perception in quiet and Speech Intelligibility Test sentence perception in noise was evaluated at the end of each of the time intervals. Word perception was also monitored at fortnightly intervals during the B time interval. Speech production was assessed at the end of the initial A time interval and at the end of the B time interval. RESULTS: Mean word and phoneme scores for open-set words in quiet for the group of seven children were significantly higher with the ACE strategy as compared with the SPEAK strategy scores obtained in both of the A time intervals. For sentences in noise, mean scores using the ACE strategy as well as the SPEAK strategy at the second A evaluation point were significantly higher than the scores using the SPEAK strategy measured at the first A time interval. This suggests that learning effects may have influenced outcomes. For some subjects, an initial decrease in scores was found during the initial 2-wk period after fitting the ACE strategy; however, scores subsequently were found to be similar to or higher than those when using the initial SPEAK strategy. Analysis of speech production assessments showed an improvement in the medial consonant scores after using the ACE strategy. CONCLUSIONS: This study demonstrated that some children were able to benefit from the additional information provided by the ACE strategy as compared with the SPEAK strategy. However, the differences in overall performance between the two strategies appear to be relatively small.


Assuntos
Estimulação Acústica/instrumentação , Implante Coclear , Surdez/reabilitação , Percepção da Fala/fisiologia , Adolescente , Criança , Desenho de Equipamento , Feminino , Humanos , Masculino , Medida da Produção da Fala
12.
Am J Ind Med ; 32(5): 528-34, 1997 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9327078

RESUMO

We conducted a 4-year (1/89-12/92) retrospective cohort study among employees at a large metropolitan hospital where a nosocomial outbreak of multidrug-resistant tuberculosis (TB) had occurred. We compared the risk of tuberculin skin test (TST) conversion among employees who worked on wards where patients with culture-confirmed TB were cared for ("exposed") with the risk among employees who worked on wards with no such patients ("unexposed"). Exposed employees had a higher 4-year risk of TST conversion (14.5%) than unexposed employees (1.4%) (adjusted relative risk 13.4; 95 percent confidence interval 5.1-35.2). Exposed employees had significantly higher risks of conversion than unexposed employees during 1989-91, but not for 1992. Among the exposed, ward clerks had a risk of conversion (15.6%) only slightly lower than nurses (18.2%). We conclude that employees who worked in areas where patients with active M. tuberculosis infection were cared for, including workers who did not provide direct patient care, had a higher risk of TST conversion than employees who did not work in these areas. Reasons for the decline in risk over time include outbreak termination, fewer admissions of patients with TB, implementation of effective infection control measures, and possible resistance to infection in some members of the study population.


Assuntos
Infecção Hospitalar/transmissão , Surtos de Doenças , Exposição Ocupacional/análise , Recursos Humanos em Hospital , Tuberculose Resistente a Múltiplos Medicamentos/epidemiologia , Adulto , Feminino , Humanos , Incidência , Masculino , Exposição Ocupacional/prevenção & controle , Estudos Retrospectivos , Risco , Estudos Soroepidemiológicos , Estados Unidos/epidemiologia
13.
Appl Opt ; 10(8): 1971-2, 1971 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-20111243
14.
Appl Opt ; 13(6): 1296-7, 1974 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-20126188
15.
Appl Opt ; 12(6): 1108, 1973 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-20125485
16.
17.
Appl Opt ; 8(12): 2552-4, 1969 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-20076074
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA