Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38480567

RESUMO

OBJECTIVES: Aim of this study was to assess the value of virtual non-contrast (VNC) reconstructions in differentiating between adrenal adenomas and metastases on a photon-counting detector CT (PCD-CT). MATERIAL AND METHODS: Patients with adrenal masses and contrast-enhanced CT scans in portal venous phase were included. Image reconstructions were performed, including conventional VNC (VNCConv) and PureCalcium VNC (VNCPC), as well as virtual monochromatic images (VMI, 40-90 keV) and iodine maps. We analyzed images using semi-automatic segmentation of adrenal lesions and extracted quantitative data. Logistic regression models, non-parametric tests, Bland-Altman plots, and a random forest classifier were used for statistical analyses. RESULTS: The final study cohort consisted of 90 patients (36 female, mean age 67.8 years [range 39-87]) with adrenal lesions (45 adenomas, 45 metastases). Compared to metastases, adrenal adenomas showed significantly lower CT-values in VNCConv and VNCPC (p = 0.007). Mean difference between VNC and true non-contrast (TNC) was 17.67 for VNCConv and 14.85 for VNCPC. Random forest classifier and logistic regression models both identified VNCConv and VNCPC as the best discriminators. When using 26 HU as the threshold in VNCConv reconstructions, adenomas could be discriminated from metastases with a sensitivity of 86.7% and a specificity of 75.6%. CONCLUSION: VNC algorithms overestimate CT values compared to TNC in the assessment of adrenal lesions. However, they allow a reliable discrimination between adrenal adenomas and metastases and could be used in clinical routine in near future with an increased threshold (e.g., 26 HU). Further (multi-center) studies with larger patient cohorts and standardized protocols are required. CLINICAL RELEVANCE STATEMENT: VNC reconstructions overestimate CT values compared to TNC. Using a different threshold (e.g., 26 HU compared to the established 10 HU), VNC has a high diagnostic accuracy for the discrimination between adrenal adenomas and metastases. KEY POINTS: • Virtual non-contrast reconstructions may be promising tools to differentiate adrenal lesions and might save further diagnostic tests. • The conventional and a new calcium-preserving virtual non-contrast algorithm tend to systematically overestimate CT-values compared to true non-contrast images. • Therefore, increasing the established threshold for true non-contrast images (e.g., 10HU) may help to differentiate between adrenal adenomas and metastases on contrast-enhanced CT.

2.
Colorectal Dis ; 26(2): 335-347, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38115093

RESUMO

AIM: The aims of this study were to analyse all hospitalizations for acute diverticulitis in Germany from 2010 to 2021 and to assess the effects of the first 2 years of the SARS-CoV-2 pandemic on hospitalizations for acute diverticulitis. METHOD: Using data from the German Federal Statistical Office, we analysed fully anonymized healthcare data of hospitalizations and treatment regimens with acute diverticulitis as the main diagnosis between 2010 and 2021. Logistic regression analyses for in-hospital mortality were performed. RESULTS: A total of 608,162 hospitalizations were included. While the number of hospitalizations constantly increased until 2019 (+52.4%), a relative decrease of 10.1% was observed between 2019 and 2020, followed by stable numbers of hospitalizations in 2021 (+1.1% compared with 2020). In-hospital mortality showed a relative decrease of 33.2% until 2019 and thereafter a relative increase of 26.9% in 2020 and of 7.5% in 2021. A 21.6% and a 19.3% drop in hospitalizations was observed during the first and second waves of the SARS-CoV-2 pandemic, mostly affecting hospitalizations for uncomplicated diverticulitis, with a corresponding 11.6% and 16.8% increase in admissions for complicated diverticulitis. Multivariable logistic regression analyses showed significantly higher in-hospital mortality for hospitalizations in which surgery (OR = 2.76) and CT (OR = 1.32) were given, as well as lower mortality for women (OR = 0.88), whereas percutaneous drainage was not associated with higher in-hospital mortality compared with conservative treatment (OR = 0.71). CONCLUSION: This study points out the long-term trends in inpatient treatment for acute diverticulitis and the in-hospital mortality risk factors of patients hospitalized for acute diverticulitis in a large nationwide cohort, as well as changes in these trends and factors resulting from the SARS-CoV-2 pandemic. These changes might be attributable to delayed diagnosis and thus more severe stages of disease as a result of containment measures.


Assuntos
COVID-19 , Diverticulite , Humanos , Feminino , SARS-CoV-2 , Pandemias , Pacientes Internados , COVID-19/epidemiologia , Diverticulite/terapia , Hospitalização , Estudos Retrospectivos
3.
Radiol Med ; 129(3): 401-410, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38319495

RESUMO

PURPOSE: To assess the reliability of virtual non-contrast (VNC) derived coronary artery calcium quantities in relation to heart rate and the VNC algorithm used compared to reference true non-contrast (TNC), considering several clinically established acquisition modes. MATERIAL AND METHODS: An ad hoc built coronary phantom containing four calcified lesions and an iodinated lumen was scanned using three cardiac acquisition modes three times within an anthropomorphic cardiac motion phantom simulating different heart rates (0, 60, 80, 100 bpm) and reconstructed with a conventional (VNCconv) and a calcium-sensitive (VNCpc) VNC algorithm. TNC reference was scanned at 0 bpm with non-iodinated lumen. Calcium scores were assessed in terms of number of lesions detected, Agatston and volume scores and global noise was measured. Paired t-test and Wilcoxon test were performed to test measurements for significant difference. RESULTS: For both VNC algorithms used, calcium levels or noise were not significantly affected by heart rate. Measurements on VNCpc reconstructions best reproduced TNC results, but with increased variability (Agatston scores at 0 bpm for TNC, VNCconv, and VNCpc were 47.1 ± 1.1, 6.7 ± 2.8 (p < 0.001), and 45.3 ± 7.6 (p > 0.05), respectively). VNC reconstructions showed lower noise levels compared to TNC, especially for VNCpc (noiseheart on TNC, VNCconv and VNCpc at 0 bpm was 5.0 ± 0.4, 4.5 ± 0.2, 4.2 ± 0.2). CONCLUSION: No significant heart rate dependence of VNC-based calcium scores was observed in an intra-reconstruction comparison. VNCpc reproduces TNC scores better than VNCconv without significant differences and decreased noise, however, with an increasing average deviation with rising heart rates. VNC-based CACS should be used with caution as the measures show higher variability compared to reference TNC and therefore hold the potential of incorrect risk categorization.


Assuntos
Cálcio , Tomografia Computadorizada por Raios X , Humanos , Frequência Cardíaca , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Tórax
4.
Eur Radiol ; 33(4): 2450-2460, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36462042

RESUMO

OBJECTIVES: To assess epicardial adipose tissue (EAT) volume and attenuation of different virtual non-contrast (VNC) reconstructions derived from coronary CTA (CCTA) datasets of a photon-counting detector (PCD) CT-system to replace true non-contrast (TNC) series. METHODS: Consecutive patients (n = 42) with clinically indicated CCTA and coronary TNC were included. Two VNC series were reconstructed, using a conventional (VNCConv) and a novel calcium-preserving (VNCPC) algorithm. EAT was segmented on TNC, VNCConv, VNCPC, and CCTA (CTA-30) series using thresholds of -190 to -30 HU and an additional segmentation on the CCTA series with an upper threshold of 0 HU (CTA0). EAT volumes and their histograms were assessed for each series. Linear regression was used to correlate EAT volumes and the Euclidian distance for histograms. The paired t-test and the Wilcoxon signed-rank test were used to assess differences for parametric and non-parametric data. RESULTS: EAT volumes from VNC and CCTA series showed significant differences compared to TNC (all p < .05), but excellent correlation (all R2 > 0.9). Measurements on the novel VNCPC series showed the best correlation (R2 = 0.99) and only minor absolute differences compared to TNC values. Mean volume differences were -12%, -3%, -13%, and +10% for VNCConv, VNCPC, CTA-30, and CTA0 compared to TNC. Distribution of CT values on VNCPC showed less difference to TNC than on VNCConv (mean attenuation difference +7% vs. +2%; Euclidean distance of histograms 0.029 vs. 0.016). CONCLUSIONS: VNCPC-reconstructions of PCD-CCTA datasets can be used to reliably assess EAT volume with a high accuracy and only minor differences in CT values compared to TNC. Substitution of TNC would significantly decrease patient's radiation dose. KEY POINTS: • Measurement of epicardial adipose tissue (EAT) volume and attenuation are feasible on virtual non-contrast (VNC) series with excellent correlation to true non-contrast series (all R2>0.9). • Differences in VNC algorithms have a significant impact on EAT volume and CT attenuation values. • A novel VNC algorithm (VNCPC) enables reliable assessment of EAT volume and attenuation with superior accuracy compared to measurements on conventional VNC- and CCTA-series.


Assuntos
Angiografia , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Reprodutibilidade dos Testes , Fótons , Tecido Adiposo/diagnóstico por imagem , Estudos Retrospectivos
5.
Eur Radiol ; 33(4): 2469-2477, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36462045

RESUMO

OBJECTIVES: To assess the impact of scan modes and reconstruction kernels using a novel dual-source photon-counting detector CT (PCD-CT) on lumen visibility and sharpness of different stent sizes. METHODS: A phantom containing six balloon-expandable stents (2.5 to 9 mm diameter) in silicone tubing was scanned on a PCD-CT with standard (0.6 mm and 0.4 mm thicknesses) and ultra-high-resolution (0.2 mm thickness) modes. With the use of increasing contrast medium concentrations, densities of 0, 200, 400, and 600 HU were achieved. Standard-resolution scans were reconstructed using increasing sharpness kernels, using both polyenergetic quantitative soft tissue "conventional" ((Qr40c(0.6 mm), Qr40c(0.4 mm), Qr72c(0.2 mm)) and vascular (Bv) virtual monoenergetic reconstructions (Bv44m(0.4 mm), Bv60m(0.4 mm)) at 70 keV. In-stent lumen visibility, sharpness (max. ΔHU of the stent measured in profile plots), and in-stent noise (standard deviation of HU) were measured. RESULTS: In-stent lumen visibility was highest for Qr72c(0.2 mm) (86.5 ± 2.8% to 88.3 ± 2.6%) and in Bv60m(0.4 mm) reconstructions (77.3 ± 2.9 to 82.7 ± 2.5%). Lumen visibility was lowest in the smallest stent (2.5 mm) ranging from 54.1% in Qr40c(0.6 mm) to 74.1% in Qr72c(0.2 mm) and highest in the largest stent (9 mm) ranging from 93.8% in Qr40c(0.6 mm) to 99.1% in the Qr72c(0.2 mm) series. Lumen visibility decreased by 2.1% for every 200-HU increase in lumen attenuation. Max. ΔHU between stents and stent lumen was highest in Qr72c(0.2 mm) (ΔHU 892 ± 504 to 1526 ± 517) and Bv60m(0.4 mm) series (ΔHU 480 ± 357 to 1030 ± 344). Improvement of lumen visibility and sharpness in UHR and Bv60m(0.4 mm) series was strongest in smaller stent sizes. CONCLUSION: UHR acquisition mode and sharp reconstruction kernels on a novel PCD-CT system significantly improve in-stent lumen visibility and sharpness-especially for smaller stent sizes. KEY POINTS: • In-stent lumen visibility and sharpness of stents significantly improve using sharp reconstruction kernels (Bv60) and ultra-high-resolution mode in photon-counting detector computed tomography. • The observed improvement of stent-lumen visibility was highest in smaller stent sizes.


Assuntos
Stents , Tomografia Computadorizada por Raios X , Humanos , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Imagens de Fantasmas
6.
BMC Gastroenterol ; 23(1): 300, 2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37674195

RESUMO

BACKGROUND: Aim of this study was to analyze long-term trends of hospitalizations, treatment regimen and in-hospital mortality of in-patients with acute mesenteric ischemia (AMI) over the past decade and effects of the SARS-CoV2-pandemic. METHODS: We analyzed fully anonymized data from the German Federal Statistical Office of patients with AMI between 2010 and 2020. Besides descriptive analyses of age, gender, in-hospital mortality, comorbidity burden and treatment regimen, multivariable logistic regression analyses were performed to identify independent variables associated with in-hospital mortality and different treatment. RESULTS: A total of 278,121 hospitalizations (120,667 male [43.4%], mean age 72.1 years) with AMI were included in this study. The total number of hospitalizations increased from 2010 (n = 24,172) to 2019 (n = 26,684) (relative increase 10.4%). In-hospital mortality decreased over the past decade from 36.6% to 2010 to 31.1% in 2019 (rel. decrease 15.2%). Independent risk factors for in-hospital mortality were older age (OR = 1.03 per year), higher comorbidity burden (OR = 1.06 per point in van Walraven score [vWs]), male gender (OR = 1.07), AMI as a secondary diagnosis (OR = 1.44), and the need for surgical (visceral surgery: OR = 1.38, vascular surgery: OR = 3.33) and endovascular treatment (OR = 1.21). We report a decline in hospitalizations during the first wave of infection in spring 2020 (rel. decrease 9.7%). CONCLUSION: In-hospital mortality rate has declined over the past decade, but remains high at above 30%. Older age, increased comorbidity and male gender are independent factors for in-hospital mortality. Hospitalizations requiring vascular surgery are associated with high in-hospital mortality, followed by visceral surgery and endovascular approaches. The first wave of the SARS-CoV2-pandemic in spring 2020 implied a decrease in hospital admissions.


Assuntos
COVID-19 , Isquemia Mesentérica , Humanos , Masculino , Idoso , Isquemia Mesentérica/epidemiologia , Isquemia Mesentérica/cirurgia , RNA Viral , COVID-19/epidemiologia , SARS-CoV-2 , Mortalidade Hospitalar
8.
J Magn Reson Imaging ; 55(1): 246-254, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34323329

RESUMO

BACKGROUND: Quiescent-interval slice-selective (QISS) magnetic resonance angiography (MRA) is a non-contrast alternative for the pre-procedural assessment of patients with peripheral artery disease (PAD). However, the feasibility of pre-procedural stent size estimation using QISS MRA would merit investigation. PURPOSE: To evaluate the feasibility of QISS MRA for pre-procedural stent size estimation in PAD patients compared to computed tomography angiography (CTA). STUDY TYPE: Retrospective. SUBJECTS: Thirty-three PAD patients (68 ± 9 years, 18 men, 15 women). FIELD STRENGTH/SEQUENCE: Two-dimensional balanced steady-state free precession QISS MRA at 1.5 T and 3 T. ASSESSMENT: All patients received QISS MRA and CTA of the lower extremity run-off followed by interventional digital subtraction angiography (DSA). Stenotic lesion length and diameter were quantified (AMF and AVS with 3 and 13 years of experience in cardiovascular imaging, respectively) to estimate the dimensions of the stent necessary to restore blood flow in the treated arteries. Measured dimensions were adjusted to the closest stent size available. STATISTICAL TESTS: The Friedman test with subsequent pairwise Wilcoxon signed-rank test was used to compare the estimated stent dimensions between QISS MRA, CTA, and the physical stent size used for intervention. Intra-class correlation (ICC) analysis was performed to assess inter-reader agreement. Significant differences were considered at P < 0.05. RESULTS: No significant difference was observed between estimated stent diameter by QISS MRA or CTA compared to physical stent diameter (8.9 ± 2.9 mm, 8.8 ± 3.0 mm, and 8.8 ± 3.8 mm, respectively; χ2  = 1.45, P = 0.483). There was a significant underestimation of stent length for both QISS MRA and CTA, compared to physical stent length (45.8 ± 27.8 mm, 46.4 ± 29.3 mm, and 50.4 ± 34.0 mm, respectively; χ2  = 11.96) which could be corrected when measurements were adjusted to the next available stent length (χ2  = 2.38, P = 0.303). Inter-reader assessment showed good to excellent agreement between the readers (all ICC ≥0.81). DATA CONCLUSION: QISS MRA represents a reliable method for pre-procedural lesion assessment and stent diameter and length estimation in PAD patients. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.


Assuntos
Doença Arterial Periférica , Humanos , Doença Arterial Periférica/diagnóstico por imagem , Estudos Retrospectivos , Stents
9.
Eur Radiol ; 32(3): 1697-1708, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34647176

RESUMO

OBJECTIVES: To analyze trends of in-hospital treatment of patients admitted due to peripheral artery disease (PAD) from 2009 to 2018 with special focus on comorbidities, revascularization procedures, resulting costs, and outcome. METHODS: Using data from the research data center of the German Federal Statistical Office, we included all hospitalizations due to PAD Fontaine stage IIb or higher from 2009 to 2018. To analyze comorbidities, Elixhauser diagnostic groups and linear van Walraven score (vWS) were assessed. RESULTS: A total of 1.8 million hospitalizations resulting in €10.3 billion in reimbursement costs were included. From 2009 to 2018, the absolute number of hospitalizations due to PAD increased by 13.3% (163,547 to 185,352). The average cost per hospitalization increased by 20.8% from €5,261 to €6,356. The overall in-hospital mortality decreased from 3.1 to 2.6%. Median vWS of all PAD cases increased by 3 points (2 to 5). The number of percutaneous transluminal angioplasties (PTA) increased by 43.9% while some surgical procedures such as bypasses and embolectomies decreased by 30.8% and 6.8%, respectively. Many revascularization procedures showed a disproportionate increase of those performed in vessels below the knee for example in PTA (+ 68.5%) or in endarterectomies (+ 38.8%). CONCLUSIONS: This decade-long nationwide analysis shows a rising number of hospitalizations due to PAD with more comorbid patients resulting in increasing reimbursement costs. Interventions are shifting from surgical to endovascular approaches with a notable trend towards interventions in smaller vessels below the knee. KEY POINTS: • The number of hospitalizations due to peripheral artery disease is rising and it is associated with increasing reimbursement costs. • Admitted patients are older and show an increasing number of comorbidities while overall in-hospital mortality is decreasing. • Revascularization procedures are shifting from surgical to endovascular approaches and show a trend towards intervention in smaller vessels below the knee. • Major amputations are decreasing while the number of minor amputations is increasing.


Assuntos
Procedimentos Endovasculares , Doença Arterial Periférica , Atenção à Saúde , Hospitalização , Humanos , Doença Arterial Periférica/epidemiologia , Doença Arterial Periférica/terapia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
10.
Eur Radiol ; 32(5): 2930-2936, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34936011

RESUMO

OBJECTIVES: Photon-counting detector CT (PCD-CT) promises a leap in spatial resolution due to smaller detector pixel sizes than implemented in energy-integrating detector CTs (EID-CT). Our objective was to compare the visualization of smallest bone details between PCD-CT and EID-CT using a mouse as a specimen. MATERIALS AND METHODS: Two euthanized mice were scanned at a 20-slice EID-CT and a dual-source PCD-CT in single-pixel mode at various CTDIVol values. Image noise and signal-to-noise ratio (SNR) were evaluated using repeated ROI measurements. Edge sharpness of bones was compared by the maximal slope within CT value plots along sampling lines intersecting predefined bones of the spine. Two readers evaluated bone detail visualization at four regions of the spine on a three-point Likert scale at various CTDIVol's. Two radiologists selected the series with better detail visualization among each of 20 SNR-matched pairs of EID-CT and PCD-CT series. RESULTS: In CTDIVol-matched scans, PCD-CT series showed significantly lower image noise (NoiseCTDI=5 mGy: 16.27 ± 1.39 vs. 23.46 ± 0.96 HU, p < 0.01), higher SNR (SNRCTDI=5 mGy: 20.57 ± 1.89 vs. 14.00 ± 0.66, p < 0.01), and higher edge sharpness (Edge Slopelumbar spine: 981 ± 160 vs. 608 ± 146 HU/mm, p < 0.01) than EID-CT series. Two radiologists considered the delineation of bone details as feasible at consistently lower CTDIVol values at PCD-CT than at EID-CT. In comparison of SNR-matched reconstructions, PCD-CT series were still considered superior in almost all cases. CONCLUSIONS: In this head-to-head comparison, PCD-CT showed superior objective and subjective image quality characteristics over EID-CT for the delineation of tiniest bone details. Even in SNR-matched pairs (acquired at different CTDIVol's), PCD-CT was strongly preferred by radiologists. KEY POINTS: • In dose-matched scans, photon-counting detector CT series showed significantly less image noise, higher signal-to-noise ratio, and higher edge sharpness than energy-integrating detector CT series. • Human observers considered the delineation of tiny bone details as feasible at much lower dose levels in photon-counting detector CT than in energy-integrating detector CT. • In direct comparison of series matched for signal-to-noise ratio, photon-counting detector CT series were considered superior in almost all cases.


Assuntos
Fótons , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Razão Sinal-Ruído , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/métodos
11.
Eur Radiol ; 32(9): 6008-6016, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35359166

RESUMO

OBJECTIVES: To evaluate feasibility and diagnostic performance of coronary CT angiography (CCTA)-derived fractional flow reserve (CT-FFR) for detection of significant coronary artery disease (CAD) and decision-making in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) to potentially avoid additional pre-TAVR invasive coronary angiography (ICA). METHODS: Consecutive patients with severe AS (n = 95, 78.6 ± 8.8 years, 53% female) undergoing pre-procedural TAVR-CT followed by ICA with quantitative coronary angiography were retrospectively analyzed. CCTA datasets were evaluated using CAD Reporting and Data System (CAD-RADS) classification. CT-FFR measurements were computed using an on-site machine-learning algorithm. A combined algorithm was developed for decision-making to determine if ICA is needed based on pre-TAVR CCTA: [1] all patients with CAD-RADS ≥ 4 are referred for ICA; [2] patients with CAD-RADS 2 and 3 are evaluated utilizing CT-FFR and sent to ICA if CT-FFR ≤ 0.80; [3] patients with CAD-RADS < 2 or CAD-RADS 2-3 and normal CT-FFR are not referred for ICA. RESULTS: Twelve patients (13%) had significant CAD (≥ 70% stenosis) on ICA and were treated with PCI. Twenty-eight patients (30%) showed CT-FFR ≤ 0.80 and 24 (86%) of those were reported to have a maximum stenosis ≥ 50% during ICA. Using the proposed algorithm, significant CAD could be identified with a sensitivity, specificity, and positive and negative predictive value of 100%, 78%, 40%, and 100%, respectively, potentially decreasing the number of necessary ICAs by 65 (68%). CONCLUSION: Combination of CT-FFR and CAD-RADS is able to identify significant CAD pre-TAVR and bears potential to significantly reduce the number of needed ICAs. KEY POINTS: • Coronary CT angiography-derived fractional flow reserve (CT-FFR) using machine learning together with the CAD Reporting and Data System (CAD-RADS) classification safely identifies significant coronary artery disease based on quantitative coronary angiography in patients prior to transcatheter aortic valve replacement. • The combination of CT-FFR and CAD-RADS enables decision-making and bears the potential to significantly reduce the number of needed invasive coronary angiographies.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Constrição Patológica , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/cirurgia , Feminino , Humanos , Aprendizado de Máquina , Masculino , Valor Preditivo dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
12.
AJR Am J Roentgenol ; 218(3): 444-452, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34643107

RESUMO

BACKGROUND. Cardiac CTA is required for preprocedural workup before transcatheter aortic valve replacement (TAVR) and can be used to assess functional parameters of the left atrium (LA). OBJECTIVE. We aimed to evaluate the utility of functional and volumetric LA parameters derived from cardiac CTA to predict mortality in patients with severe aortic stenosis (AS) undergoing TAVR. METHODS. This retrospective study included 175 patients with severe AS (92 men, 83 women; median age, 79.0 years) who underwent cardiac CTA for clinical pre-TAVR assessment. A postdoctoral research fellow calculated maximum and minimum LA volumes using biplane area-length measurements; these values were indexed to body surface area, and maximum and minimum LA volume index (LAVImax and LAVImin, respectively) values were calculated. The LA emptying fraction (LAEF) was automatically calculated. All-cause mortality within a 24-month follow-up period after TAVR was recorded. To identify parameters predictive of mortality, Cox regression analysis was performed, and results were summarized by hazard ratio (HR) and 95% CI. The Harrell C-index was used to assess model performance. A radiology resident repeated the measurements in a random sample of 20% (n = 35) of the cases, and interobserver agreement was computed using the intraclass correlation coefficient (ICC). RESULTS. Thirty-eight deaths (21.7%) were recorded within a median follow-up of 21 months. LAVImax (HR, 1.02 [95% CI, 1.01-1.04]; p = .01), LAVImin (HR, 1.02 [95% CI, 1.01-1.04]; p < .001), and LAEF (HR, 0.97 [95% CI, 0.95-0.99]; p = .002) were predictive of mortality in univariable analysis. After adjusting for clinical parameters, only LAEF (HR, 0.97 [95% CI, 0.94-0.99]; p = .02) independently predicted mortality. The C-index of the Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) significantly increased from 0.636 to 0.683, 0.694, and 0.700 when incorporating into the model LAVImax, LAVImin, and LAEF, respectively. The ICC for maximum and minimum LA volumes and LAEF ranged from 0.94 to 0.99. CONCLUSION. LAEF derived from preprocedural cardiac CTA independently predicts mortality in patients with severe AS undergoing TAVR. CLINICAL IMPACT. Cardiac CTA-derived LA function, evaluated during pre-TAVR workup, can be used to assess preprocedural risk and may improve risk stratification in post-TAVR surveillance.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Cuidados Pré-Operatórios/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Retrospectivos , Resultado do Tratamento
13.
Abdom Radiol (NY) ; 49(1): 103-116, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37796327

RESUMO

PURPOSE: To analyze the conspicuity of pancreatic ductal adenocarcinoma (PDAC) in virtual monoenergetic images (VMI) on a novel photon-counting detector CT (PCD-CT) in comparison to energy-integrating CT (EID-CT). METHODS: Inclusion criteria comprised initial diagnosis of PDAC (reference standard: histopathological analysis) and standardized contrast-enhanced CT imaging either on an EID-CT or a PCD-CT. Patients were excluded due to different histopathological diagnosis or missing tumor delineation on CT. On the PCD-CT, 40-190 keV VMI reconstructions were generated. Image noise, tumor-to-pancreas ratio (TPR) and contrast-to-noise ratio (CNR) were analyzed by ROI-based measurements in arterial and portal venous contrast phase. Two board-certified radiologist evaluated image quality and tumor delineation at both, EID-CT and PCD-CT (40 and 70 keV). RESULTS: Thirty-eight patients (mean age 70.4 years ± 10.3 [range 45-91], 27 males; PCD-CT: n=19, EID-CT: n=19) were retrospectively included. On the PCD-CT, tumor conspicuity (reflected by low TPR and high CNR) was significantly improved at low-energy VMI series (≤ 70 keV compared to > 70 keV), both in arterial and in portal venous contrast phase (P < 0.001), reaching the maximum at 40 keV. Comparison between PCD-CT and EID-CT showed significantly higher CNR on the PCD-CT in portal venous contrast phase at < 70 keV (P < 0.016). On the PCD-CT, tumor conspicuity was improved in portal venous contrast phase compared to arterial contrast phase especially at the lower end of the VMI spectrum (≤ 70 keV). Qualitative analysis revealed that tumor delineation is improved in 40 keV reconstructions compared to 70 keV reconstructions on a PCD-CT. CONCLUSION: PCD-CT VMI reconstructions (≤ 70 keV) showed significantly improved conspicuity of PDAC in quantitative and qualitative analysis in both, arterial and portal venous contrast phase, compared to EID-CT, which may be important for early detection of tumor tissue in clinical routine. Tumor delineation was superior in portal venous contrast phase compared to arterial contrast phase.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Masculino , Humanos , Idoso , Estudos Retrospectivos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Carcinoma Ductal Pancreático/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
14.
Rofo ; 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38788741

RESUMO

The introduction of photon-counting detector CT (PCD-CT) marks a remarkable leap in innovation in CT imaging. The new detector technology allows X-rays to be converted directly into an electrical signal without an intermediate step via a scintillation layer and allows the energy of individual photons to be measured. Initial data show high spatial resolution, complete elimination of electronic noise, and steady availability of spectral image data sets. In particular, the new technology shows promise with respect to the imaging of osseous structures. Recently, PCD-CT was implemented in the clinical routine. The aim of this review was to summarize recent studies and to show our first experiences with photon-counting detector technology in the field of musculoskeletal radiology.We performed a literature search using Medline and included a total of 90 articles and reviews that covered recent experimental and clinical experiences with the new technology.In this review, we focus on (1) spatial resolution and delineation of fine anatomic structures, (2) reduction of radiation dose, (3) electronic noise, (4) techniques for metal artifact reduction, and (5) possibilities of spectral imaging. This article provides insight into our first experiences with photon-counting detector technology and shows results and images from experimental and clinical studies. · This review summarizes recent experimental and clinical studies in the field of photon-counting detector CT and musculoskeletal radiology.. · The potential of photon-counting detector technology in the field of musculoskeletal radiology includes improved spatial resolution, reduction in radiation dose, metal artifact reduction, and spectral imaging.. · PCD-CT enables imaging at lower radiation doses while maintaining or even enhancing spatial resolution, crucial for reducing patient exposure, especially in repeated or prolonged imaging scenarios.. · It offers promising results in reducing metal artifacts commonly encountered in orthopedic or dental implants, enhancing the interpretability of adjacent structures in postoperative and follow-up imaging.. · With its ability to routinely acquire spectral data, PCD-CT scans allow for material classification, such as detecting urate crystals in suspected gout or visualizing bone marrow edema, potentially reducing reliance on MRI in certain cases.. Bette S, Risch F, Becker J et al. Photon-counting detector CT - first experiences in the field of musculoskeletal radiology. Fortschr Röntgenstr 2024; DOI 10.1055/a-2312-6914.

15.
J Thorac Imaging ; 39(2): 93-100, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37889562

RESUMO

PURPOSE: To evaluate a novel deep learning (DL)-based automated coronary labeling approach for structured reporting of coronary artery disease according to the guidelines of the Society of Cardiovascular Computed Tomography (CT) on coronary CT angiography (CCTA). PATIENTS AND METHODS: A retrospective cohort of 104 patients (60.3 ± 10.7 y, 61% males) who had undergone prospectively electrocardiogram-synchronized CCTA were included. Coronary centerlines were automatically extracted, labeled, and validated by 2 expert readers according to Society of Cardiovascular CT guidelines. The DL algorithm was trained on 706 radiologist-annotated cases for the task of automatically labeling coronary artery centerlines. The architecture leverages tree-structured long short-term memory recurrent neural networks to capture the full topological information of the coronary trees by using a two-step approach: a bottom-up encoding step, followed by a top-down decoding step. The first module encodes each sub-tree into fixed-sized vector representations. The decoding module then selectively attends to the aggregated global context to perform the local assignation of labels. To assess the performance of the software, percentage overlap was calculated between the labels of the algorithm and the expert readers. RESULTS: A total number of 1491 segments were identified. The artificial intelligence-based software approach yielded an average overlap of 94.4% compared with the expert readers' labels ranging from 87.1% for the posterior descending artery of the right coronary artery to 100% for the proximal segment of the right coronary artery. The average computational time was 0.5 seconds per case. The interreader overlap was 96.6%. CONCLUSIONS: The presented fully automated DL-based coronary artery labeling algorithm provides fast and precise labeling of the coronary artery segments bearing the potential to improve automated structured reporting for CCTA.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Aprendizado Profundo , Masculino , Humanos , Feminino , Angiografia por Tomografia Computadorizada/métodos , Inteligência Artificial , Estudos Retrospectivos , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Doença da Artéria Coronariana/diagnóstico por imagem
16.
Int J Cardiovasc Imaging ; 40(4): 723-732, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38175389

RESUMO

The aim of our study was to evaluate two different virtual non-contrast (VNC) algorithms applied to photon counting detector (PCD)-CT data in terms of noise, effectiveness of contrast media subtraction and aortic valve calcium (AVC) scoring compared to reference true non-contrast (TNC)-based results. Consecutive patients underwent TAVR planning examination comprising a TNC scan, followed by a CTA of the heart. VNC series were reconstructed using a conventional (VNCconv) and a calcium-preserving (VNCpc) algorithm. Noise was analyzed by means of the standard deviation of CT-values within the left ventricle. To assess the effectiveness of contrast media removal, heart volumes were segmented and the proportion of their histograms > 130HU was taken. AVC was measured by Agatston and volume score. 41 patients were included. Comparable noise levels to TNC were achieved with all VNC reconstructions. Contrast media was effectively virtually removed (proportions > 130HU from 81% to < 1%). Median calcium scores derived from VNCconv underestimated TNC-based scores (up to 74%). Results with smallest absolute difference to TNC were obtained with VNCpc reconstructions (0.4 mm, Br36, QIR 4), but with persistent significant underestimation (median 29%). Both VNC algorithms showed near-perfect (r²>0.9) correlation with TNC. Thin-slice VNC reconstructions provide equivalent noise levels to standard thick-slice TNC series and effective virtual removal of iodinated contrast. AVC scoring was feasible on both VNC series, showing near-perfect correlation, but with significant underestimation. VNCpc with 0.4 mm slices and Br36 kernel at QIR 4 gave the most comparable results and, with further advances, could be a promising replacement for additional TNC.


Assuntos
Algoritmos , Estenose da Valva Aórtica , Valva Aórtica , Valva Aórtica/patologia , Calcinose , Angiografia por Tomografia Computadorizada , Tomografia Computadorizada Multidetectores , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Feminino , Idoso , Masculino , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Reprodutibilidade dos Testes , Substituição da Valva Aórtica Transcateter/instrumentação , Calcinose/diagnóstico por imagem , Meios de Contraste/administração & dosagem
17.
Diagnostics (Basel) ; 14(7)2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38611632

RESUMO

In the early diagnostic workup of acute pancreatitis (AP), the role of contrast-enhanced CT is to establish the diagnosis in uncertain cases, assess severity, and detect potential complications like necrosis, fluid collections, bleeding or portal vein thrombosis. The value of texture analysis/radiomics of medical images has rapidly increased during the past decade, and the main focus has been on oncological imaging and tumor classification. Previous studies assessed the value of radiomics for differentiating between malignancies and inflammatory diseases of the pancreas as well as for prediction of AP severity. The aim of our study was to evaluate an automatic machine learning model for AP detection using radiomics analysis. Patients with abdominal pain and contrast-enhanced CT of the abdomen in an emergency setting were retrospectively included in this single-center study. The pancreas was automatically segmented using TotalSegmentator and radiomics features were extracted using PyRadiomics. We performed unsupervised hierarchical clustering and applied the random-forest based Boruta model to select the most important radiomics features. Important features and lipase levels were included in a logistic regression model with AP as the dependent variable. The model was established in a training cohort using fivefold cross-validation and applied to the test cohort (80/20 split). From a total of 1012 patients, 137 patients with AP and 138 patients without AP were included in the final study cohort. Feature selection confirmed 28 important features (mainly shape and first-order features) for the differentiation between AP and controls. The logistic regression model showed excellent diagnostic accuracy of radiomics features for the detection of AP, with an area under the curve (AUC) of 0.932. Using lipase levels only, an AUC of 0.946 was observed. Using both radiomics features and lipase levels, we showed an excellent AUC of 0.933 for the detection of AP. Automated segmentation of the pancreas and consecutive radiomics analysis almost achieved the high diagnostic accuracy of lipase levels, a well-established predictor of AP, and might be considered an additional diagnostic tool in unclear cases. This study provides scientific evidence that automated image analysis of the pancreas achieves comparable diagnostic accuracy to lipase levels and might therefore be used in the future in the rapidly growing era of AI-based image analysis.

18.
Cancers (Basel) ; 15(10)2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37345128

RESUMO

This study analyzes nationwide trends in HCC hospitalizations focusing on interventional liver-directed treatments and the influence of age and gender. Using data from the German Federal Statistical Office all hospitalizations for HCC between 2010 and 2020 were included. Uni- and multivariable logistic regression analyses were performed to identify variables independently associated with the use of liver-directed therapies. Due to the COVID-19 pandemic, data from 2020 were analyzed separately. A total of 134,713 hospitalizations (2010-2019) were included, increasing by 3.4% annually (12,707 to 13,143). The mean in-hospital stay (-15.0% [7.2 to 6.1 days]) and mortality (-23.2% [6.8 to 5.2%]) decreased while transarterial, surgical, and percutaneous ablative interventions increased by 38.6, 31.5, and 19.3%, respectively. In-hospital mortality was 7.7% in admissions with surgical treatment, while it was 0.6 and 0.5% for transarterial and percutaneous interventions. Mortality was higher in females (6.2 vs. 5.7%). Females (OR 0.89 [0.86,0.91], p < 0.001) and patients ≥80 years (OR 0.81 [0.79,0.84], p < 0.001) were less likely to receive liver-directed treatments. Liver-directed therapies were increasingly performed while in-hospital mortality and in-hospital stay decreased. Minimally invasive approaches showed lower mortality, shorter in-hospital stay, and lower costs compared to surgery. Proportionately, more women and older patients were hospitalized, receiving fewer liver-directed treatments while their mortality was higher.

19.
Cardiovasc Intervent Radiol ; 46(10): 1385-1393, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37700006

RESUMO

PURPOSE: To investigate differences in thermal sensitivity of virtual monoenergetic imaging (VMI) series generated from photon-counting detector (PCD) CT data sets, regarding their use to improve discrimination of the ablation zone during percutaneous cryoablation. MATERIALS AND METHODS: CT-guided cryoablation was performed using an ex vivo model of porcine liver on a PCD-CT system. The ablation zone was imaged continuously for 8 min by acquiring a CT scan every 5 s. Tissue temperature was measured using fiberoptic temperature probes placed parallel to the cryoprobe. CT-values and noise were measured at the tip of the temperature probes on each scan and on VMI series from 40 to 130 keV. Correlation of CT-values and temperature was assessed using linear regression analyses. RESULTS: For the whole temperature range of [- 40, + 20] °C, we observed a linear correlation between CT-values and temperature in reference 70 keV images (R2 = 0.60, p < 0.001) with a thermal sensitivity of 1.4HU/°C. For the most dynamic range of [- 15, + 20] °C, the sensitivity increased to 2.4HU/°C (R2 = 0.50, p < 0.001). Using VMI reconstructions, the thermal sensitivity increased from 1.4 HU/°C at 70 keV to 1.5, 1.7 and 2.0HU/°C at 60, 50 and 40 keV, respectively (range [- 40, + 20] °C). For [- 15, + 20]°C, the thermal sensitivity increased from 2.4HU/°C at 70 keV to 2.5, 2.6 and 2.7HU/°C at 60, 50 and 40 keV, respectively. Both CT-values and noise also increased with decreasing VMI keV-levels. CONCLUSION: During CT-guided cryoablation of porcine liver, low-keV VMI reconstructions derived from PCD-CT data sets exhibit improved thermal sensitivity being highest between + 20 and - 15 °C.


Assuntos
Criocirurgia , Suínos , Animais , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Abdome , Estudos Retrospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
20.
Eur J Radiol ; 168: 111125, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37804649

RESUMO

PURPOSE: Aim of this study was to determine which virtual non-contrast (VNC) reconstruction algorithm, applied to which contrast phase of computed tomography angiography, best matches true non-contrast (TNC) images in the assessment of active bleeding. METHOD: Patients who underwent a triphasic scan (pre-contrast, arterial, portal venous contrast) on a photon-counting detector CT (PCD-CT) (120 kV, image quality level 68) with suspected active (tumor, postoperative, spontaneous or other) bleeding were retrospectively included in this study. Conventional (VNCConv) and a calcium-preserving VNC algorithm (VNCPC) were derived from both arterial (art) and portal venous (pv) contrast scans, and analyzed quantitatively and qualitatively by two independent and blinded raters. RESULTS: 40 patients (22 female, mean age 76 years) were included. Measurements of CT values showed significant albeit small differences between TNC and VNC for most analyzed tissue regions without clear superiority of a VNC algorithm or contrast phase (e.g. ΔHU fat TNC to VNCPCpv 3.1 HU). However, qualitative analysis showed a preference to VNCPCpv in terms of image quality (on a 5-point Likert scale VNCConvart = 3.5 ± 0.8, VNCPCart = 3.7 ± 0.7, VNCConvpv = 3.7 ± 0.7, VNCPCpv = 3.8 ± 0.7) and residual calcium contrast (VNCConvart = 3.0 ± 0.8, VNCPCart = 3.5 ± 0.7, VNCConvpv = 3.6 ± 0.7, VNCPCpv = 3.9 ± 0.6). CONCLUSIONS: When multiple post-contrast phases are available, VNCPC series based on portal venous phase are the most suitable replacement for an additional pre-contrast scan, with the prospect of a significant reduction in patient radiation dose.


Assuntos
Cálcio , Tomografia Computadorizada por Raios X , Humanos , Feminino , Idoso , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada/métodos , Hemorragia , Algoritmos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA