RESUMO
This manuscript presents the results of the International Measurement Evaluation Programme 40 (IMEP-40) study, a proficiency test (PT) which was organised to assess the worldwide performance of laboratories for the determination of trace elements in seawater. This PT supports the implementation of the European Union Water Framework Directive 2000/60/EC, which aims at achieving a long-term high level protection of the aquatic environment, covering lakes, ground water and coastal waters. Forty-six participants reported results. The test item was seawater containing the trace elements As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Se and Zn. The trace elements in the test item were present in very low concentrations to mimic natural levels. The results of the participants were rated with z and zeta (ζ) scores in accordance with ISO 13528 and ISO 17043. The standard deviation for proficiency assessment, σÌ, was set at 25% of the respective assigned values for the 12 measured elements based on previous experience with similar PTs. The low levels of the trace elements combined with the high salt concentration of the seawater made the measurements challenging. Many laboratories were unable to detect or quantify the elements and reported "lower than X" values. The percentage of satisfactory performances (expressed as z scores) ranged from 41% (Cr, Fe) to 86% (Mo). The PT study showed that the use of proper standard methods, like ISO 17294-2, and sensitive techniques, like inductively coupled plasma mass spectrometry (ICP-MS), contributed to performing well in this PT round.
RESUMO
The determination of urea in pet feed at contaminant levels using the spectrophotometric method described in Commission Regulation (EC) No 152/2009 has been reported by several EU laboratories to lack the required selectivity. Whilst urea is not authorised as an additive in pet feed, the control of urea in pet feed is of economic importance, because the addition of urea may unlawfully increase the apparent protein content. To investigate the capabilities of different analytical techniques, a proficiency test was organised where the participants (EU official control laboratories, laboratories from the academia and private laboratories) were free to use their method of choice for analysing three dog feed test materials, two samples of which were spiked with urea. Twenty-one laboratories submitted results using the following techniques: spectrophotometry (Implementing Regulation (EC) No 152/2009), LC-MS/MS, HPLC-UV, enzymatic-colorimetry, gravimetry and an 'in-house photometric' method. Only two laboratories that used LC-MS/MS were able to quantify urea accurately in the test material containing a mass fraction of 18.9 mg kg-1 whereas satisfactory results at the level of 258.9 mg kg-1 were obtained by one participant that used an 'in-house photometric method' and one that used the enzymatic method, in addition to the five participants using LC-MS/MS. The technique that provided the highest success rate across the three test materials was LC-MS/MS, whereas spectrophotometry, the enzymatic-based and HPLC-UV methods led to overestimated results in addition to a dispersion of results not suitable for compliance analysis. To address the determination of urea in pet feed at low levels, a better performing method than the one described in the legislation is required.
Assuntos
Espectrometria de Massas em Tandem , Ureia , Animais , Cães , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida/métodos , Espectrometria de Massa com Cromatografia LíquidaRESUMO
The outcome of a proficiency test (PT) organised by the European Union Reference Laboratory for Food Contact Materials (EURL-FCM) is presented. The PT was set up to assess the analytical performance of National Reference Laboratories (NRLs) and Official Control Laboratories (OCLs) in the determination of mass fractions of polyethylene terephthalate (PET) and polybutylene terephthalate (PBT) cyclic dimers and trimers in the official food simulant D1 containing ethanol and water (50:50 v/v). The EURL-FCM had developed and validated an analytical method based on HPLC-UV to monitor the homogeneity and stability of the target oligomers in the PT test items and to determine the respective assigned values, as prescribed in ISO 17043, 2010ISO 17043, 2010. The standard operating procedure of the method was provided to the participants and could be used instead of their own routine methods. Laboratory results were rated using z, z' and ζ scores in accordance with ISO 13528, 2015. The standard deviation for proficiency assessment, σpt , was set to 20 % of the respective assigned value, for all the four studied oligomers, based on the perception of experts. A total of 36 participants from 26 countries have registered to the exercise. They received two test items. Solution 1 consisted of food simulant D1 fortified with a known mass fraction of the four oligomers, while Solution 2 was obtained by a migration experiment with PET bottles and food simulant D1 and further fortification of the resulting solution with the four oligomers. The majority of the participating laboratories presented satisfactory results for the four PET and PBT oligomers. For the analysis of Solution 1, 79-88 % of the participants obtained |z (or z')-scores| below 2, while the satisfactory performances ranged from 71 to 85 % for Solution 2. This PT has been organised for the first time at EU level for the analysis of polyester oligomers and confirms that most of the NRLs are able to monitor properly these oligomers in the frame of Regulation (EU) No 10/2011.
RESUMO
In this paper, the performance of a previously developed classification system applied to pharmaceutical chromatographic analyses, is investigated. The separation of seven different drug substances from their respective impurities was studied. The chromatographic procedure for acetylsalicylic acid, clindamycin hydrochloride, buflomedil hydrochloride, chloramphenicol sodium succinate, nimesulide and phenoxymethylpenicillin was performed according to the corresponding European Pharmacopoeia (Ph. Eur.) monograph. The separation of dihydrostreptomycin sulphate was performed according to the literature. It is shown that the column ranking system is a helpful tool in the selection of a suitable column in these analyses.
Assuntos
Cromatografia Líquida/instrumentação , Preparações Farmacêuticas/isolamento & purificação , Aspirina/isolamento & purificação , Cloranfenicol/análogos & derivados , Cloranfenicol/isolamento & purificação , Cromatografia Líquida/métodos , Clindamicina/isolamento & purificação , Sulfato de Di-Hidroestreptomicina/isolamento & purificação , Penicilina V/isolamento & purificação , Pirrolidinas/isolamento & purificação , Sensibilidade e Especificidade , Sulfonamidas/isolamento & purificaçãoRESUMO
Benzamycin, combining benzoyl peroxide and erythromycin, is a topical gel used in the treatment of acne vulgaris. Because of the reactivity of benzoyl peroxide, preparations containing both erythromycin and benzoyl peroxide might be unstable and degradation products could be formed. To investigate and identify these latter products, a gradient-based liquid chromatographic method using volatile mobile phase constituents was developed. Mass spectrometry data were acquired on solutions containing erythromycin and benzoyl peroxide and on freshly prepared, 2-month-old and 18-month-old samples of Benzamycin. With the reference spectra as interpretative templates, it was concluded that erythromycin undergoes oxidation, followed by benzoylation.
Assuntos
Peróxido de Benzoíla/química , Química Farmacêutica/métodos , Cromatografia Líquida/métodos , Eritromicina/química , Espectrometria de Massas/métodos , Tecnologia Farmacêutica/métodos , Peróxido de Benzoíla/análise , Estabilidade de Medicamentos , Eritromicina/análise , Géis/química , Modelos QuímicosRESUMO
This review presents an overview of analytical methods for the analysis of pesticide residues in grapes and by-products in the last decade. The most widely used detection technique for the determination of pesticides in grapes is mass spectrometry combined with gas and/or liquid chromatography. In general, multi-residue methods with selective sample treatment methodologies have been developed for this purpose. However, this review focuses not only on these common multi-residue methods but also on specific methodologies as single-residue methods for the analysis of pesticides in grapes and by-products. Finally, the limitations of multi-residue methods, the future perspectives and the trends for pesticide residue analysis in grapes are reviewed.
Assuntos
Resíduos de Praguicidas/análise , Vitis/química , Cromatografia Gasosa , Cromatografia Líquida , Espectrometria de Massas , Praguicidas/análiseRESUMO
This manuscript presents the results of the International Measurement Evaluation Programme 37 (IMEP-37) study, a proficiency test (PT) which was organised to assess the world-wide performance of food control laboratories on the determination of pesticide residues in grapes. This PT supports the implementation of Regulation (EC) No 396/2005 on maximum residue levels of pesticides in or on food and feed of plant and animal origin. Eighty-one participants reported results, forty from EU Member States and forty-one from outside the EU. The test item was a grape sample spiked with 20 selected pesticides. The results of the participants were rated with z- and zeta (ζ-) scores in accordance with ISO 13528 and ISO 17043. The standard deviation for the proficiency assessment, σË, of this PT was set at 25% for the 20 measured pesticides based on previous experience with similar measurands. The results reported to IMEP-37 showed that the participants performed satisfactorily, ranging from 81% (carbendazim) to 97% (azoxystrobin, penconazole, pyrimethanil) of the participating laboratories. However, only 30% of the participants managed to analyze all pesticides satisfactorily. Overall, the performance of the participants in this PT was good but there is room for improvement in the development of multi-residue methods for the simultaneous analysis of a large number of pesticides with an increased accuracy.
Assuntos
Análise de Alimentos/métodos , Análise de Alimentos/normas , Laboratórios/normas , Resíduos de Praguicidas/análise , Vitis/químicaRESUMO
The European Pharmacopoeia (Ph. Eur.) and other official compendia give only a general description of the stationary phase in the description of a liquid chromatographic method. Therefore the selection of a column giving suitable selectivity presents difficulties. Earlier, a test procedure was proposed that allows to measure 36 chromatographic parameters which have been described for characterising stationary phases. This procedure was carried out on 69 reversed-phase liquid chromatography (RP-LC) columns. This paper focuses on the classification of RP-LC stationary phases based on chromatographic parameters. A chemometric study was conducted using 24 parameters that could be measured in a repeatable and reproducible way. Principal component analysis was used to classify the columns and to estimate the minimal number of parameters necessary for a rational classification. It is shown that after reducing the number of parameters from 24 to four or three, similar classifications were obtained. The column classifications were compared to the European Pharmacopoeia stationary phase description and to the column properties obtained from the manufacturers.
Assuntos
Cromatografia Líquida/instrumentação , Cromatografia Líquida/métodosRESUMO
Selection of RP-LC columns with suitable selectivity for a given analysis is difficult. For example, the European Pharmacopoeia (Ph. Eur.) and other official compendia for drug analysis only give a general description of the stationary phase in the operating procedure of a liquid chromatographic method. The need for a general test method to characterise RP-LC columns has been rising since the 1970s. A project to define a chromatographic procedure characterising RP-LC columns was started earlier. A procedure to measure test parameters was introduced and a classification of the columns, based on a minimal number of parameters, was obtained. This paper focuses on correlating the column classification with the selectivity obtained for a real separation. The separation of acetylsalicylic acid (aspirin) and related compounds was performed according to the Ph. Eur. monograph on the stationary phases previously characterised chromatographically. It was examined whether the classes of columns, determined using test parameter results, contain either suitable or unsuitable supports for the aspirin separation. The system suitability test prescribed by the Ph. Eur. in order to distinguish between suitable or unsuitable columns for this separation was also evaluated.
Assuntos
Aspirina/isolamento & purificação , Cromatografia Líquida/métodos , Cromatografia Líquida/instrumentaçãoRESUMO
A CE method for metacycline (MTC) determination was investigated in an inter-laboratory experiment. Many problems were encountered in this study, most of which were related to the transfer of the method to different CE equipment. The reported problems could be classified into different categories: problems related to the precision, to the parameters in the protocol, and to the MTC peak shape. As the peak shape problem was partially responsible for the poor precision, a new CE method was developed in order to obtain a good MTC peak shape on all equipment. The precision of this new method for MTC determination was examined in an intermediate precision study, where the influence of the factors "time" and "equipment" was investigated. Although the new method could be transferred to different instruments, the precision remained poor mainly due to the contributions of the between-replicate and the between-injection variances.
Assuntos
Antibacterianos/análise , Eletroforese Capilar/métodos , Metaciclina/análise , Sensibilidade e EspecificidadeRESUMO
We describe an intermediate precision study on a capillary electrophoretic (CE) method for chlortetracycline. It is shown how in one setup the influence of the factors time, analyst, and equipment on the precision can be investigated. As different types of CE equipments were included, the transferability of the method could be examined. Both the qualitative and quantitative aspect of the method were investigated. It was shown that small adaptations in method conditions can have a large influence on the method transferability. Although the method could be transferred to different types of CE equipments, the precision of the method was found poor when the between-equipment variability was taken into account. Despite the use of an internal standard, the between injection variability was found rather high.