Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Med Oral Patol Oral Cir Bucal ; 27(2): e125-e134, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34564681

RESUMO

BACKGROUND: To investigate the true accuracy of the surgical guide in the planning of orthognathic surgeries, which are performed worldwide. MATERIAL AND METHODS: A systematic search was conducted in the PubMed database, Web of science, Scopus and Embase, covering August 2020 to January 2021. Studies that included patients with dentofacial deformity including anteroposterior, vertical and asymmetry problems who were undergoing an orthognathic surgery procedure were included; QUADAS-2 was used to determine the risk of bias by analyzing the quality of the studies. A PRISMA (flowchart) was created to show the study selection, keywords, nomination processes, and inclusion and exclusion criteria. RESULTS: Eleven studies were selected for qualitative and quantitative synthesis. All studies evaluated described high precision of the surgical guide, where the lowest error values were represented by the CAD/CAM technique. CONCLUSIONS: The planning and printing errors related to the guide were all less than 2 mm, and the absolute averages of the errors related to virtual planning in the analysis of the different plans were less than 1 mm. Finally, the measurement of the ANB angle obtained equivalent results between the virtual planning and the traditional.


Assuntos
Cirurgia Ortognática , Procedimentos Cirúrgicos Ortognáticos , Cirurgia Assistida por Computador , Desenho Assistido por Computador , Humanos , Imageamento Tridimensional , Procedimentos Cirúrgicos Ortognáticos/métodos , Impressão Tridimensional , Cirurgia Assistida por Computador/métodos
2.
Comput Aided Surg ; 10(3): 173-80, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-16321915

RESUMO

OBJECTIVE: Methods of evaluating surgical performance are mainly subjective. This study introduces a method of evaluating surgical performance using a quantitative analysis of tool tip kinematics. METHODS: One experienced surgeon performed eight rat microvascular anastomoses over a 2-day interval. An optoelectronic motion analysis system acquired tool tip trajectories at frequencies of 30 Hz. On the basis of a hierarchical decomposition, the procedure was segmented into specific surgical subtasks (free space movement, needle placement and knot throws) from which characteristic measures of performance (tool tip trajectory, excursion and velocity) were evaluated. Comparisons of performance measures across each procedure were indexed (D scale) using the Kolmogorov-Smirnov statistic. RESULTS: Despite the marker occlusions, tool tip data were obtained 92 +/- 7% (mean +/- SD) of the time during manipulation tasks. Missing data segments were interpolated across gaps of less than 10 sample points with errors less than 0.4 mm. The anastomoses were completed in 27 +/- 4 min (range 20.5-31.4 min) with 100% patency. Tool tip trajectories and excursions were comparable for each hand, while right and left hand differences were found for velocity. Performance measures comparisons across each procedure established the benchmark for an experienced surgeon. The D-scale range was between 0 and 0.5. CONCLUSION: The study establishes a reproducible method of quantitating surgical performance. This may enhance assessment of surgical trainees at various levels of training.


Assuntos
Anastomose Cirúrgica/métodos , Anastomose Cirúrgica/normas , Competência Clínica , Microcirurgia/métodos , Microcirurgia/normas , Procedimentos Cirúrgicos Vasculares/métodos , Procedimentos Cirúrgicos Vasculares/normas , Animais , Automação , Fenômenos Biomecânicos , Desempenho Psicomotor , Ratos , Estatísticas não Paramétricas , Gravação em Vídeo
3.
Neurosurgery ; 52(3): 668-74; discussion 672-4, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12590693

RESUMO

IN 1846, CARL ZEISS established a workshop to make lenses for microscopes, cameras, binoculars, and astronomical observatories. He was a master craftsman and was intolerant of any flaw, destroying microscopes with only minor inaccuracies. His relentless pursuit of perfection brought him into contact with a brilliant physicist, Ernst Abbe. Zeiss combined Abbe's new optical laws with his own technical skills; together, they created a colossus. Their company came to be known not only for exquisite technical standards but also for labor relations that were and remain progressive. The development of microneurosurgery was aided by the active participation of Carl Zeiss, Inc. The history of this company provides a lesson in the power of entrepreneurship and the benefits to humanity that can accrue from a fruitful partnership between medical science and industry.


Assuntos
Astronomia/história , Microscopia/história , Alemanha , História do Século XIX
4.
Neurosurgery ; 54(3): 525-36; discussion 536-7, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15028126

RESUMO

PURPOSE: The purpose of this article is to update the neurosurgical community on the expanding field of surgical robotics and to present the design of a novel neurosurgical prototype. It is intended to mimic standard technique and deploy conventional microsurgical tools. The intention is to ease its integration into the "nervous system" of both the traditional operating room and surgeon. CONCEPT: To permit benefit from updated intraoperative imaging, magnetic resonance imaging-compatible materials were incorporated into the design. Advanced haptics, optics, and auditory communication with the surgical site recreate the sight, sound, and feel of neurosurgery. RATIONALE: Magnification and advanced imaging have pushed surgeons to the limit of their dexterity and stamina. Robots, in contrast, are indefatigable and have superior spatial resolution and geometric accuracy. The use of tremor filters and motion scalers permits procedures requiring superior dexterity. DISCUSSION: Breadboard testing of the prototype components has shown spatial resolution of 30 microm, greatly exceeding our expectations. Neurosurgeons will not only be able to perform current procedures with a higher margin of safety but also must speculate on techniques that have hitherto not even been contemplated. This includes coupling the robot to intelligent tools that interrogate tissue before its manipulation and the potential of molecular imaging to transform neurosurgical research into surgical exploration of the cell, not the organ.


Assuntos
Microcirurgia/instrumentação , Neurocirurgia/instrumentação , Robótica/instrumentação , Cirurgia Assistida por Computador/instrumentação , Inteligência Artificial , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Imageamento Tridimensional/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Salas Cirúrgicas , Equipamentos Cirúrgicos , Avaliação da Tecnologia Biomédica
5.
J Neurosurg ; 98(3): 638-41, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12650441

RESUMO

This communication outlines the development of aneurysm clips, from those originally used by Walter Dandy to those in use today. The history is rich, with many contributions from neurosurgical pioneers and innovators. As a result, the modern neurosurgeon has a wide selection of biocompatible aneurysm clips from which to choose, clips that have known closing pressures and various sizes and shapes, as well as a selection of clip applicators that do not obstruct the surgical field.


Assuntos
Aneurisma/história , Neurocirurgia/história , Instrumentos Cirúrgicos/história , Aneurisma/cirurgia , Desenho de Equipamento , História do Século XX , Humanos , Neurocirurgia/instrumentação
6.
Am J Surg ; 188(4A Suppl): 68S-75S, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15476655

RESUMO

Technological developments in imaging guidance, intraoperative imaging, and microscopy have pushed neurosurgeons to the limits of their dexterity and stamina. The introduction of robotically assisted surgery has provided surgeons with improved ergonomics and enhanced visualization, dexterity, and haptic capabilities. This article provides a historical perspective on neurosurgical robots, including image-guided stereotactic and microsurgery systems. The future of robot-assisted neurosurgery, including the use of surgical simulation tools and methods to evaluate surgeon performance, is discussed.


Assuntos
Procedimentos Neurocirúrgicos , Robótica , Cirurgia Assistida por Computador , Diagnóstico por Imagem , Humanos , Cuidados Intraoperatórios , Microcirurgia/métodos , Procedimentos Neurocirúrgicos/instrumentação , Robótica/instrumentação , Técnicas Estereotáxicas , Equipamentos Cirúrgicos , Instrumentos Cirúrgicos
7.
Semin Laparosc Surg ; 11(2): 99-106, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15254648

RESUMO

Technological advances in the modern operating room have pushed neurosurgeons to the limits of their dexterity and stamina. Motion scalers and tremor filters on robots permit unprecedented precision of tool manipulation, upgrading the human hand, and closing the deftness deficit. The evolution of neurosurgical robots from stereotactic systems to hybrid systems capable of both stereotaxy and microsurgery is examined. The future of robot-assisted neurosurgery, including expanded tool sets and the prospect of semi-autonomous surgery, is discussed.


Assuntos
Procedimentos Neurocirúrgicos/instrumentação , Robótica/instrumentação , Humanos
8.
Glia ; 48(2): 112-9, 2004 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-15378657

RESUMO

In humans, three isoforms of the T-type (Ca(v)3.1) calcium-channel alpha(1) subunit have been reported as a result of alternate splicing of exons 25 and 26 in the III-IV linker region (Ca(v)3.1a, Ca(v)3.1b or Ca(v)3.1bc). In the present study, we report that human glioma express Ca(v)3.1 channels in situ, that splicing of these exons is uniquely regulated and that there is expression of a glioma-specific novel T-type variant (Ca(v)3.1ac). Seven human glioma samples were collected at surgery, RNA was extracted, and cDNA was produced for RT-PCR analysis. In addition, three glioma cell lines (U87, U563, and U251N), primary cultures of human fetal astrocytes, as well as adult and fetal human brain cDNA were used. Previously described Ca(v)3.1 splice variants were present in glioma samples, cultured cells and whole brain. Consistent with the literature, our results reveal that in the normal adult brain, Ca(v)3.1a transcripts predominate, while Ca(v)3.1b is mostly fetal-specific. RT-PCR results on glioma and glioma cell lines showed that Ca(v)3.1 expression in tumor cells resemble fetal brain expression pattern as Ca(v)3.1bc is predominantly expressed. In addition, we identified a novel splice variant, Ca(v)3.1ac, expressed in three glioma biopsies and one glioma cell line, but not in normal brain or fetal astrocytes. Transient expression of this variant demonstrates that Ca(v)3.1ac displays similar current-voltage and steady-state inactivation properties compared with Ca(v)3.1b, but a slower recovery from inactivation. Taken together, our data suggest glioma-specific Ca(v)3.1 gene regulation, which could possibly contribute to tumor pathogenesis.


Assuntos
Processamento Alternativo/genética , Neoplasias Encefálicas/genética , Canais de Cálcio Tipo T/genética , Glioma/genética , Sequência de Aminoácidos/genética , Sequência de Bases/genética , Neoplasias Encefálicas/metabolismo , Canais de Cálcio Tipo T/metabolismo , Linhagem Celular , DNA Complementar/análise , DNA Complementar/genética , Éxons/genética , Feminino , Regulação Neoplásica da Expressão Gênica/genética , Glioma/metabolismo , Humanos , Masculino , Potenciais da Membrana/genética , Dados de Sequência Molecular , Técnicas de Patch-Clamp , Isoformas de Proteínas/genética , Isoformas de Proteínas/metabolismo , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA