RESUMO
BACKGROUND: To evaluate the outcomes of transcatheter aortic valve implantation (TAVI) without balloon aortic valvuloplasty (BAV) in a real-world setting through a patient-level meta-analysis. METHODS: The meta-analysis included patients of three European multicenter, prospective, observational registry studies that compared outcomes after Edwards SAPIEN 3 or XT TAVI with (n = 339) or without (n = 355) BAV. Unadjusted and adjusted pooled odds ratios (with 95% confidence intervals) were calculated for procedural and 30-day outcomes. RESULTS: Median procedural time was shorter in the non-BAV group than in the BAV group (73 versus 93 min, p = 0.001), as was median fluoroscopy time (7 versus 11 min, p = 0.001). Post-delivery balloon dilation (15.5% versus 22.4%, p = 0.02) and catecholamine use (9.0% vs. 17.9%; p = 0.016) was required less often in the non-BAV group than in the BAV group with the difference becoming insignificant after multiple adjustment. There was a reduced risk for periprocedural atrioventricular block during the intervention (1.4% versus 4.1%, p = 0.035) which was non-significant after adjustment. The rate of moderate/severe paravalvular regurgitation post-TAVI was 0.6% in the no-BAV group versus 2.7% in the BAV group. There were no between-group differences in the risk of death, stroke or other adverse clinical outcomes at day 30. CONCLUSIONS: This patient-level meta-analysis of real-world data indicates that TAVI performed without BAV is advantageous as it has an adequate device success rate, reduced procedure time and no adverse effects on short-term clinical outcomes.
Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Europa (Continente) , Feminino , Próteses Valvulares Cardíacas , Hemodinâmica , Humanos , Masculino , Estudos Multicêntricos como Assunto , Estudos Observacionais como Assunto , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do TratamentoRESUMO
BACKGROUND: A new genotype of the zoophilic fungal species Trichophyton (T.) mentagrophytes was recently described in two studies. It was isolated from three patients who had visited Southeast Asia and one patient who had visited Egypt. In contrast to these studies, we have observed a number of cases with the dimensions of an epidemic outbreak. PATIENTS AND METHODS: At the University Hospital Charité Berlin, 43 patients, mostly suffering from highly inflammatory, painful and persistent infections of the pubogenital region were observed between January 2016 and July 2017. Mycological examination was performed with fungal culture and sequencing of the ITS (internal transcribed spacer) region of the ribosomal DNA. Three additional genomic regions were spot-checked. RESULTS: In 37 of the cases, a new genotype of T. mentagrophytes (referred to here as T. mentagrophytes VII) was isolated as the etiological agent, and sequencing revealed identical sequences for all isolates. Most of the infected patients had no history of travel, and only two patients reported contact with animals. CONCLUSIONS: The new genotype clustered phylogenetically among the strains of the zoophilic species T. mentagrophytes with four different DNA markers. While human-to-human transmission of zoophilic dermatophytes is rare, transmission via sexual contact seemed to be quite effective here.
Assuntos
Infecções Sexualmente Transmissíveis/microbiologia , Tinha/microbiologia , Trichophyton/isolamento & purificação , Adulto , Animais , Antifúngicos/uso terapêutico , DNA Fúngico/análise , Quimioterapia Combinada , Feminino , Doenças dos Genitais Femininos/tratamento farmacológico , Doenças dos Genitais Femininos/microbiologia , Doenças dos Genitais Masculinos/tratamento farmacológico , Doenças dos Genitais Masculinos/microbiologia , Genótipo , Humanos , Masculino , Pessoa de Meia-Idade , Pomadas , Filogenia , Prurido/microbiologia , Análise de Sequência de DNA , Infecções Sexualmente Transmissíveis/tratamento farmacológico , Infecções Sexualmente Transmissíveis/transmissão , Tinha/transmissão , Viagem , Resultado do Tratamento , Adulto Jovem , Zoonoses/tratamento farmacológico , Zoonoses/microbiologia , Zoonoses/transmissãoRESUMO
BACKGROUND: In older patients with aortic stenosis (AS) undergoing TAVI, the potential role of prior CGA is not well established. To explore the value of comprehensive geriatric assessment (CGA) for predicting mortality and/or hospitalisation within the first 3 months after transcatheter aortic valve implantation (TAVI). METHODS: An international, multi-centre, prospective registry (CGA-TAVI) was established to gather data on CGA results and medium-term outcomes in geriatric patients undergoing TAVI. Logistic regression was used to evaluate the predictive value of a multidimensional prognostic index (MPI); a short physical performance battery (SPPB); and the Silver Code, which was based on administrative data, for predicting death and/or hospitalisation in the first 3 months after TAVI (primary endpoint). RESULTS: A total of 71 TAVI patients (mean age 85.4 years; mean log EuroSCORE I 22.5%) were enrolled. Device success according to VARC criteria was 100%. After adjustment for selected baseline characteristics, a higher (poorer) MPI score (OR: 3.34; 95% CI: 1.39-8.02; p = 0.0068) and a lower (poorer) SPPB score (OR: 1.15; 95% CI: 1.01-1.54; p = 0.0380) were found to be associated with an increased likelihood of the primary endpoint. The Silver Code did not show any predictive ability in this population. CONCLUSIONS: Several aspects of the CGA have shown promise for being of use to physicians when predicting TAVI outcomes. While the MPI may be useful in clinical practice, the SPPB may be of particular value, being simple and quick to perform. Validation of these findings in a larger sample is warranted. TRIAL REGISTRATION: The trial was registered in ClinicalTrials.gov on November 7, 2013 ( NCT01991444 ).
Assuntos
Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Técnicas de Apoio para a Decisão , Avaliação Geriátrica , Substituição da Valva Aórtica Transcateter , Fatores Etários , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Humanos , Itália , Modelos Logísticos , Masculino , Países Baixos , Razão de Chances , Readmissão do Paciente , Valor Preditivo dos Testes , Estudos Prospectivos , Quebeque , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do TratamentoRESUMO
The purpose of the study was to validate the ambulatory blood pressure monitoring (ABPM) device custo screen pediatric in children aged 3 to 12 years according to the International Protocol of the European Society of Hypertension (ESH-IP revision 2010). Thirty-three children were included and systolic and diastolic blood pressure measurements were performed according to the ESH-IP. The protocol was modified for children considering data from the German Health Interview and Examination Survey for Children and Adolescents (KIGGS). The custo screen pediatric met all the requirements of the ESH-IP. The mean difference between the test device and the reference was -1.4 ± 3.0 mmHg for systolic blood pressure (SBP) and -0.7 ± 3.2 mmHg for diastolic blood pressure (DBP). For SBP and DBP, all 99 measurements were within the absolute difference of 10 mmHg between the test device and the reference. As to part 2 of the protocol, for DBP in all subjects, two out of three measurements were within 5 mmHg between the device and the standard, whereas for SBP in 32 of 33 subjects, two out of three measurements were within this range. CONCLUSION: The custo screen pediatric met all criteria of the ESH-IP review 2010, modified for children from 3 to about 12 years, and can be recommended for ABPM in children. What is Known: ⢠Validation of blood pressure measuring devices is essential to provide patients with an accurate blood pressure measuring device. ⢠The majority of devices has not been validated in children. What is New: ⢠Prior to the present validation, study protocol adjustments of ESH-IP review 2010 for children were defined according to German Health Interview and Examination Survey for Children and Adolescents 2013 (KIGGS). ⢠The custo screen pediatric test device met all criteria of ESH-IP revision 2010, modified for children, and can be recommended for ABPM in children aged 3 to about 12 years.
Assuntos
Monitorização Ambulatorial da Pressão Arterial/instrumentação , Monitores de Pressão Arterial/normas , Pressão Sanguínea , Monitorização Ambulatorial da Pressão Arterial/normas , Criança , Pré-Escolar , Desenho de Equipamento , Feminino , Humanos , Masculino , Guias de Prática Clínica como Assunto , Valores de Referência , Reprodutibilidade dos Testes , Sociedades MédicasRESUMO
The risk of infection in patients with rheumatic diseases is elevated, but a clear marker to differentiate the cause of the systemic inflammation is missing. We assessed the ability urinary immunoglobulin free light chains (FLCs) to indicate the presence of infection in patients with rheumatic disease. We performed a retrospective analysis of patients with rheumatic disease attending the Georg-August University Hospital in Goettingen, Germany, from January 2011 to December 2013. Subjects were included if they had urine levels of κ and λ FLCs available. A reference group of patients without autoimmune disease, but with documented infection, was constructed. A total of 1500 patients had their urinary FLCs quantified during the study period. Of the 382 patients with rheumatic disease, 172 (45%) displayed no systemic inflammation, 162 (42%) had inflammation due to the underlying disease activity, and 48 (13%) had inflammation due to a confirmed infection. Urinary FLC concentrations were much higher in patients with rheumatic diseases and infection (κ 68.8 ± 81.8 mg/L, λ 31.4 ± 53.5 mg/L) compared to those with inflammation due to rheumatic disease activity (κ 22.7 ± 26.3 mg/L, λ 8.1 ± 9.1 mg/L, κ p < 0.001, λ p = 0.004). Urinary κ FLCs demonstrated good ability to predict infection, with a sensitivity of 63% and specificity of 84%. Urinary λ FLCs gave similar values, with a sensitivity of 65% and specificity of 81%. FLCs may be useful for distinguishing inflammation due to rheumatic disease activity from that due to the additional presence of infection. The ability to quantify these proteins in urine provides a simple alternative to the use of blood.
Assuntos
Cadeias Leves de Imunoglobulina/urina , Infecções/diagnóstico , Inflamação/complicações , Doenças Reumáticas/complicações , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/urina , Feminino , Humanos , Infecções/complicações , Infecções/urina , Inflamação/urina , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Doenças Reumáticas/urina , Sensibilidade e EspecificidadeRESUMO
Introduction: The use of an aortic bioprosthesis is on the rise in younger patients with severe aortic stenosis despite the risk of accelerated structural valve degeneration (SVD). In the search for an optimal valve substitute that would not be prone to SVD, the INSPIRIS bioprosthesis represents a promising solution to lowering the risk of SVD. Here, we report the 1-year outcomes of the INSPIRIS RESILIA aortic bioprosthesis in a population of young patients who underwent aortic valve replacement. Methods: In this prospective single-center study, we included all consecutive patients receiving INSPIRIS RESILIA bioprosthesis between June 2017 and July 2021. Patients with isolated severe aortic regurgitation were excluded. Clinical assessment and transthoracic echocardiography were performed preoperatively and at 1 year post-operatively. The primary outcome was overall mortality at one year. Results: A total of 487 patients were included. The mean age was 58.2 ± 11.5 years, 75.2% were men. Most of the interventions were elective, with a mean EuroSCORE II of 4.8 ± 7.9. The valve annulus size in most cases was either 23â mm or 25â mm. Overall mortality at 1-year was 4.1%. At 1-year, 7 patients (1.4%) had a stroke, 4 patients (0.8%) had a myocardial infarction, and 20 patients (4.1%) were hospitalized for congestive heart failure. The Kaplan-Meier estimated survival rates and survival without major adverse cardiac events at 1-year were 96.4% and 96.7%, respectively. At 1-year follow-up, 10 patients (2.1%) had endocarditis and 1 patient (0.2%) had partial prosthetic thrombosis. Pacemaker implantation at 1-year post-operative was necessary in 27 patients (5.5%). Severe patient prosthesis mismatch and severe intra valvular regurgitation were 1.2% and 0.6%, respectively. The Kaplan-Meier estimated survival rates at 1-year of no infective endocarditis preoperative and infective endocarditis preoperative were 97.9 ± 0.7% and 89.5 ± 3.3%, respectively (P < 0.001). Excluding endocarditis-related complication, no structural valve deterioration and no valve failure requiring redo surgery were reported. Conclusion: This is the largest single-center descriptive study of the 1-year outcomes after INSPIRIS RESILIA bioprosthesis implantation. The EDWARDS INSPIRIS RESILIA bioprosthesis provides encouraging clinical outcomes with an excellent 1- year survival rates and good hemodynamic performance. Long-term studies are mandatory to assess valve durability.
RESUMO
OBJECTIVE: Current guidelines recommend use of heart valve centres (HVCs) to deliver optimal quality of care for patients with valve disease but there is no evidence to support this. The hypothesis of this study is that patient care with severe aortic stenosis (AS) will differ in HVCs compared with satellite centres. We aimed to compare the treatment of patients with AS at HVCs (tertiary care hospitals with full access to AS interventions) to satellites (hospitals without such access). METHODS: IMPULSE enhanced is a European, observational, prospective registry enrolling consecutive patients with newly diagnosed severe AS at four HVCs and 10 satellites. Clinical characteristics, interventions performed and outcomes up to 1 year by site-type were examined. RESULTS: Among 790 patients, 594 were recruited in HVCs and 196 in satellites. At baseline, patients in HVCs had more severe valve disease (higher peak aortic velocity (4.3 vs 4.1 m/s; p=0.008)) and greater comorbidity (coronary artery disease (CAD) (44% vs 27%; p<0.001) prior myocardial infarction (MI) (11% vs 5.1%; p=0.011) and chronic pulmonary disease (17% vs 8.9%; p=0.007)) than those presenting in satellites. An aortic valve replacement was performed more often by month 3 in HVCs than satellites in the overall population (52.6% of vs 31.3%; p<0.001) and in symptomatic patients (66.7% vs 43.2%, p<0.001). One-year survival rate was higher for patients in HVCs than satellites (HR2.19; 95% CI 1.28 to 3.73 total population and 2.89 (95%CI 1.64 to 5.11) for symptomatic patients. CONCLUSIONS: Our data support the implementation of referral pathways that direct patients to HVCs performing both surgery and transcatheter interventions. TRIAL REGISTRATION NUMBER: NCT03112629.
Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Centros de Cuidados de Saúde Secundários , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de RiscoRESUMO
The transcatheter aortic valve implantation (TAVI) treatment pathway is complex, leading to procedure-related delays. Dedicated TAVI coordinators can improve pathway efficiency. COORDINATE was a pilot observational prospective registry at three German centers that enrolled consecutive elective patients with severe aortic stenosis undergoing TAVI to investigate the impact a TAVI coordinator program. Pathway parameters and clinical outcomes were assessed before (control group) and after TAVI coordinator program implementation (intervention phase). The number of repeated diagnostics remained unchanged after implementation. Patients with separate hospitalizations for screening and TAVI had long delays, which increased after implementation (65 days pre- vs. 103 days post-implementation); hospitalizations combining these were more efficient. The mean time between TAVI and hospital discharge remained constant. Nurse (p = 0.001) and medical technician (p = 0.008) working hours decreased. Patient satisfaction increased, and more consistent/intensive contact between patients and staff was reported. TAVI coordinators provided more post-TAVI support, including discharge management. No adverse effects on post-procedure or 30-day outcomes were seen. This pilot suggests that TAVI coordinator programs may improve aspects of the TAVI pathway, including post-TAVI care and patient satisfaction, without compromising safety. These findings will be further investigated in the BENCHMARK registry.
RESUMO
OBJECTIVE: Aim of this study was to validate the Microlife BP B3 AFIB/enterprise resource planning (ERP) No: BP3KT1-3 N blood pressure (BP) monitor according to the American National Standards Institute (ANSI)/Association for the Advancement of Medical Instrumentation (AAMI)/International Organization for Standardization (ISO) 81060-2:2019 in adolescents and adults from a general population. METHODS: BP measurements on the upper arm were performed in 85 subjects (age range 12-88 years), using the Microlife BP B3 AFIB and a standard mercury reference sphygmomanometer. RESULTS: A total of 255 valid BP comparisons were performed for the present validation analysis. The mean ± SD difference between the test and the reference device was 0.70 ± 7.05 mmHg for SBP (pass criterion ≤5 mmHg) and -0.85 ± 4.70 mmHg for DBP (pass criterion ≤5 mmHg) with the SD below the required value of ≤8 mmHg. The mean ± SD of the intraindividual differences between the test and the reference device was 0.70 ± 5.87 mmHg for SBP (pass criterion for the SD ≤6.90 mmHg) and -0.85 ± 4.19 mmHg for DBP (pass criterion for the SD ≤6.88 mmHg). CONCLUSION: The Microlife BP B3 AFIB/ERP No: BP3KT1-3 N has passed the criteria of the ANSI/AAMI/ISO 81060-2:2019 protocol and can be recommended for home BP measurements in adolescents and adults.
Assuntos
Fibrilação Atrial , Monitores de Pressão Arterial , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Braço , Pressão Sanguínea , Determinação da Pressão Arterial , Criança , Humanos , Pessoa de Meia-Idade , Padrões de Referência , Esfigmomanômetros , Adulto JovemRESUMO
OBJECTIVE: The aim of the present study was to validate the blood pressure (BP) monitor Beurer BM 28 according to the International Protocol of the European Society of Hypertension (ESH-IP) revision 2010. METHODS: In 33 subjects of age 27-81 years, BP measurements were performed according to the ESH-IP protocol, which alternates reference mercury sphygmomanometer and device-under-test (Beurer BM 28) measurements, resulting in a total of 99 comparisons. RESULTS: As to part 1 of the protocol, an absolute difference within 5 mmHg between the Beurer BM 28 and the test device was found in 83 out of 99 comparisons for the SBP and 82 out of 99 comparisons for the DBP. In 95 out of 99 SBP comparisons and 96 out of 99 DBP comparisons, the difference was found to be within 10 mmHg, whereas only one outlier was noted with an SBP difference higher than 15 mmHg. Mean difference between the test device and the reference was 0.4 ± 4.4 mmHg for SBP, and 0.5 ± 4.3 mmHg for DBP. According to part 2 of the protocol, 30 out of 33 subjects for SBP, and 28 out of 33 for DBP had a minimum of two out of three comparisons staying within the range of 5 mmHg. In none of the subjects, all three comparisons stayed outside the 5 mmHg absolute difference, while in three subjects this was the case for the DBP. CONCLUSION: The Beurer BM 28 met all requirements of the ESH-IP revision 2010 and can be recommended for BP measurements in the study population under investigation.
Assuntos
Monitores de Pressão Arterial , Hipertensão , Adulto , Idoso , Idoso de 80 Anos ou mais , Pressão Sanguínea , Determinação da Pressão Arterial , Monitorização Ambulatorial da Pressão Arterial , Humanos , Hipertensão/diagnóstico , Pessoa de Meia-Idade , EsfigmomanômetrosRESUMO
BACKGROUND: Degenerative aortic stenosis (AS), the most common valvular heart disease in the Western world, is often diagnosed late when the mortality risk becomes substantial. We determined the feasibility of AS screening during influenza vaccination at general practitioner (GP) surgeries in the UK. METHODS: Consecutive subjects aged >65 years presenting to a GP for influenza vaccination underwent heart auscultation and 2D echocardiography (V-scan). Based on these findings, a patient management strategy was determined (referral to cardiologist, review within own practice or no follow-up measures) and status at 3 months was determined. RESULTS: 167 patients were enrolled with a mean age of 75 years. On auscultation, a heart murmur was detected in 30 of 167 (18%) patients (6 subjects with an AS-specific and 24 with a non-specific murmur). 75.2% of those with no murmur had a negative V-scan finding. Conversely, 16 of 30 (53%) patients with any murmur had an abnormal V-scan finding that was largely related to the aortic valve. Using clinical auscultation and V-scan screening, a decision not to pursue follow-up measures was taken in 147 (88%) cases, whereas 18 (10.8%) subjects were referred onward; with 5 of 18 (27.8%) and 3 of 18 (16.7%) being diagnosed with mild and moderate AS. CONCLUSIONS: Our pilot study confirms feasibility of valvular heart disease screening in the elderly in a primary care setting. Using simple and inexpensive diagnostic measures and 7.3 million UK inhabitants undergoing influenza vaccination, nationwide screening could potentially identify 130 000 patients with moderate AS and a significant number of patients with severe AS.
Assuntos
Estenose da Valva Aórtica/diagnóstico , Serviços de Saúde Comunitária/métodos , Ecocardiografia/métodos , Vacinas contra Influenza/farmacologia , Influenza Humana/prevenção & controle , Programas de Rastreamento/métodos , Idoso , Estudos Transversais , Feminino , Seguimentos , Humanos , Vírus da Influenza A/imunologia , Influenza Humana/complicações , Masculino , Projetos Piloto , Estudos RetrospectivosRESUMO
BACKGROUND: The Toronto Aortic Stenosis Quality of Life Questionnaire (TASQ) is a validated instrument for assessing quality of life (QoL) in patients with severe aortic stenosis (AS). In this study, we evaluated health status outcomes, based on the TASQ, in patients with severe AS undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). METHODS: The TASQ registry was a prospective observational registry. Patients with severe AS from nine centres in Europe and one in Canada underwent either SAVR or transfemoral TAVR. Patients completed the TASQ, Kansas City Cardiomyopathy Questionnaire and Short Form-12 V.2 prior to the intervention, predischarge, and at 30-day and 3-month follow-ups. Primary end point was the TASQ score. RESULTS: In both the TAVR (n=137) and SAVR (n=137) cohorts, significant increases were observed in all three scores. The overall TASQ score improved as did all but one of the individual domains at 3 months after the intervention (p<0.001). TASQ health expectations were the only domain which worsened (p<0.001). Across TASQ subscores, significant changes were evident from the time of discharge in the TAVR and 30-day follow-up in the SAVR cohort. In a categorical analysis of the TASQ, 39.7% of the TAVR group and 35.0% of the SAVR group had a substantially improved health status at 3 months compared with baseline. CONCLUSIONS: The TASQ captured changes in QoL among patients with severe AS who were treated with TAVR or SAVR. QoL improved substantially after either intervention, as indicated by changes in the TASQ overall score at 3 months. TRIAL REGISTRATION NUMBER: NCT03186339.
Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Nível de Saúde , Qualidade de Vida , Inquéritos e Questionários , Substituição da Valva Aórtica Transcateter/psicologia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/psicologia , Canadá/epidemiologia , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Morbidade/tendências , Período Pós-Operatório , Estudos ProspectivosRESUMO
AIMS: There is an increasing awareness of gender-related differences in patients with severe aortic stenosis and their outcomes after surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI). METHODS: Data from the IMPULSE registry were analysed. Patients with severe aortic stenosis (AS) were enrolled between March 2015 and April 2017 and stratified by gender. A subgroup analysis was performed to assess the impact of age. RESULTS: Overall, 2171 patients were enrolled, and 48.0% were female. Women were characterised by a higher rate of renal impairment (31.7 vs 23.3%; p<0.001), were at higher surgical risk (EuroSCORE II: 4.5 vs 3.6%; p=0.001) and more often in a critical preoperative state (7.0vs 4.2%; p=0.003). Men had an increased rate of previous cardiac surgery (9.4 vs 4.7%; p<0.001) and a reduced left ventricular ejection fraction (4.9 vs 1.3%; p<0.001). Concomitant mitral and tricuspid valve disease was substantially more common among women. Symptoms were highly prevalent in both women and men (83.6 vs 77.3%; p<0.001). AVR was planned in 1379 cases. Women were more frequently scheduled to undergo TAVI (49.3 vs 41.0%; p<0.001) and less frequently for SAVR (20.3 vs 27.5%; p<0.001). CONCLUSIONS: The present data show that female patients with severe AS have a distinct patient profile and are managed in a different way to males. Gender-based differences in the management of patients with severe AS need to be taken into account more systematically to improve outcomes, especially for women.
Assuntos
Estenose da Valva Aórtica/epidemiologia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Sistema de Registros , Medição de Risco/métodos , Substituição da Valva Aórtica Transcateter/métodos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores Sexuais , Fatores de TempoRESUMO
OBJECTIVE: Approximately 3.4% of adults aged >75 years suffer from aortic stenosis (AS). Guideline indications for aortic valve replacement (AVR) distinguish between patients with symptomatic and asymptomatic severe AS. The present analysis aims to assess contemporary practice in the treatment of severe AS across Europe and identify characteristics associated with treatment decisions, namely denial of AVR in symptomatic patients and assignment of asymptomatic patients to AVR. METHODS: Participants of the prospective, multinational IMPULSE database of patients with severe AS were grouped according to AS symptoms, and stratified into subgroups based on assignment to/denial of AVR. RESULTS: Of 1608 symptomatic patients, 23.8% did not undergo AVR and underwent medical treatment. Denial was independently associated with multiple factors, including severe frailty (p=0.024); mitral (p=0.002) or tricuspid (p=0.004) regurgitation grade III/IV, and the presence of renal impairment (p=0.017). Of 392 asymptomatic patients, 86.5% had no prespecified indication for AVR. Regardless, 36.3% were assigned to valve replacement. Those with an indexed aortic valve area (AVA; p=0.045) or left ventricular ejection fraction (LVEF; p<0.001) below the study median; or with a left ventricular end systolic diameter above the study median (p=0.007) were more likely to be assigned to AVR. CONCLUSIONS: There may be considerable discrepancies between guideline-based recommendations and clinical practice decision-making in the treatment of AS. It appears that guidelines may not fully capture the complete clinical spectrum of patients with AS. Thus, there is a need to find ways to increase their acceptance and the rate of adoption.
Assuntos
Estenose da Valva Aórtica/cirurgia , Gerenciamento Clínico , Guias de Prática Clínica como Assunto , Qualidade da Assistência à Saúde , Substituição da Valva Aórtica Transcateter/normas , Idoso , Estenose da Valva Aórtica/diagnóstico , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Índice de Gravidade de DoençaRESUMO
AIMS: There is no quality of life tool specifically developed for patients with severe aortic stenosis (AS) to assess how this chronic condition and its treatment affect patients. The Toronto Aortic Stenosis Quality of Life Questionnaire (TASQ) has been developed to overcome this gap. The results of the validation of the TASQ in patients undergoing treatment for severe AS are presented. METHODS AND RESULTS: Prospective study at 10 centres in Europe and Canada, which enrolled 274 patients with severe symptomatic AS undergoing surgical or transcatheter aortic valve replacement. Mean TASQ score at baseline was 71.2 points and increased to 88.9 three months after aortic valve implantation (P < 0.001). Increases were seen for the emotional impact (32.0 to 39.0; P < 0.001), physical limitations (14.8 to 22.0; P < 0.001), and physical symptoms (8.5 vs. 11.0; P < 0.001) domains. Internal consistency was good/excellent for overall TASQ score (α = 0.891) and for the physical limitation, emotional impact, and social limitation domains (α = 0.815-0.950). Test-retest reliability was excellent or strong for the overall TASQ (intraclass correlation coefficient of 0.883) and for the physical symptoms, physical limitation, emotional impact, and social limitation domains (intraclass correlation coefficient of 0.791-0.895). Responsiveness was medium overall (Cohen's d = 0.637) and medium/large for physical symptoms, emotional impact, and physical limitations (0.661-0.812). Sensitivity to change was significant for physical symptoms, physical limitations (both P < 0.001), emotional impact (P = 0.003), and social limitations (P = 0.038). CONCLUSIONS: The TASQ is a new, brief, self-administered, and clinically relevant health-specific tool to measure changes in quality of life in patients with AS undergoing an intervention.
Assuntos
Estenose da Valva Aórtica , Qualidade de Vida , Valva Aórtica , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Canadá , Europa (Continente) , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Inquéritos e Questionários , Resultado do TratamentoRESUMO
BACKGROUND: An investigation into differences in the management and treatment of severe aortic stenosis (AS) between Germany, France and the UK may allow benchmarking of the different healthcare systems and identification of levers for improvement. METHODS: Patients with a diagnosis of severe AS under management at centres within the IMPULSE and IMPULSE enhanced registries were eligible. RESULTS: Data were collected from 2052 patients (795 Germany; 542 France; 715 UK). Patients in Germany were older (79.8 years), often symptomatic (89.5%) and female (49.8%) and had a lower EF (53.8%) than patients in France and UK. Comorbidities were more common and they had a higher mean Euroscore II.Aortic valve replacement (AVR) was planned within 3 months in 70.2%. This was higher (p<0.001) in Germany than France/ UK. Of those with planned AVR, 82.3% received it within 3 months with a gradual decline (Germany>France> UK; p<0.001). In 253 patients, AVR was not performed, despite planned. Germany had a strong transcatheter aortic valve implantation (TAVI) preference (83.2%) versus France/ UK (p<0.001). Waiting time for TAVI was shorter in Germany (24.9 days) and France (19.5 days) than UK (40.3 days).Symptomatic patients were scheduled for an AVR in 79.4% (Germany> France> UK; p<0.001) and performed in 83.6% with a TAVI preference (73.1%). 20.4% of the asymptomatic patients were intervened. CONCLUSION: Patients in Germany had more advanced disease. The rate of intervention within 3 months after diagnosis was startlingly low in the UK. Asymptomatic patients without a formal indication often underwent an intervention in Germany and France.