Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Ultrasound Med ; 40(4): 779-786, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32951229

RESUMO

OBJECTIVES: Thyroid shear wave elastography (SWE) has been shown to have advantages compared to biopsy or other imaging modalities in the evaluation of thyroid nodules. However, studies show variability in its assessment. The objective of this study was to evaluate whether stiffness measurements of the normal thyroid, as estimated by SWE, varied due to preload force or the pressure applied between the transducer and the patient. METHODS: In this study, a measurement system was attached to the ultrasound transducer to measure the applied load. Shear wave elastographic measurements were obtained from the left lobe of the thyroid at applied transducer forces between 2 and 10 N. A linear mixed-effects model was constructed to quantify the association between the preload force and stiffness while accounting for correlations between repeated measurements within each participant. The preload force effect on elasticity was modeled by both linear and quadratic terms to account for a possible nonlinear association between these variables. RESULTS: Nineteen healthy volunteers without known thyroid disease participated in the study. The participants had a mean age ± SD of 36 ± 8 years; 74% were female; 74% had a normal body mass index; and 95% were white non-Hispanic/Latino. The estimated elastographic value at a 2-N preload force was 16.7 kPa (95% confidence interval, 14.1-19.3 kPa), whereas the value at 10 N was 29.9 kPa (95% confidence interval, 24.9-34.9 kPa). CONCLUSIONS: The preload force was significantly and nonlinearly associated with SWE estimates of thyroid stiffness. Quantitative standardization of preload forces in the assessment of thyroid nodules using elastography is an integral factor for improving the accuracy of thyroid nodule evaluation.


Assuntos
Técnicas de Imagem por Elasticidade , Nódulo da Glândula Tireoide , Elasticidade , Feminino , Humanos , Masculino , Nódulo da Glândula Tireoide/diagnóstico por imagem
2.
J Ultrasound Med ; 40(3): 569-581, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33410183

RESUMO

OBJECTIVES: To quantify the bias of shear wave speed (SWS) measurements between different commercial ultrasonic shear elasticity systems and a magnetic resonance elastography (MRE) system in elastic and viscoelastic phantoms. METHODS: Two elastic phantoms, representing healthy through fibrotic liver, were measured with 5 different ultrasound platforms, and 3 viscoelastic phantoms, representing healthy through fibrotic liver tissue, were measured with 12 different ultrasound platforms. Measurements were performed with different systems at different sites, at 3 focal depths, and with different appraisers. The SWS bias across the systems was quantified as a function of the system, site, focal depth, and appraiser. A single MRE research system was also used to characterize these phantoms using discrete frequencies from 60 to 500 Hz. RESULTS: The SWS from different systems had mean difference 95% confidence intervals of ±0.145 m/s (±9.6%) across both elastic phantoms and ± 0.340 m/s (±15.3%) across the viscoelastic phantoms. The focal depth and appraiser were less significant sources of SWS variability than the system and site. Magnetic resonance elastography best matched the ultrasonic SWS in the viscoelastic phantoms using a 140 Hz source but had a - 0.27 ± 0.027-m/s (-12.2% ± 1.2%) bias when using the clinically implemented 60-Hz vibration source. CONCLUSIONS: Shear wave speed reconstruction across different manufacturer systems is more consistent in elastic than viscoelastic phantoms, with a mean difference bias of < ±10% in all cases. Magnetic resonance elastographic measurements in the elastic and viscoelastic phantoms best match the ultrasound systems with a 140-Hz excitation but have a significant negative bias operating at 60 Hz. This study establishes a foundation for meaningful comparison of SWS measurements made with different platforms.


Assuntos
Técnicas de Imagem por Elasticidade , Biomarcadores , Elasticidade , Humanos , América do Norte , Imagens de Fantasmas
3.
AJR Am J Roentgenol ; 214(4): 786-791, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31939698

RESUMO

OBJECTIVE. The purpose of this study was to assess the accuracy of portal vein pulsatility for noninvasive diagnosis of high-risk nonalcoholic fatty liver disease (NAFLD). MATERIALS AND METHODS. This retrospective study included patients with biopsy-proven diagnosis of NAFLD who underwent duplex Doppler ultrasound assessment of the main portal vein within 1 year of liver biopsy (January 2014 to February 2018). Doppler ultrasound images were reviewed. The spectral waveform was used to measure the maximum (Vmax) and minimum (Vmin) velocity of blood in the portal veins. Venous pulsatility index (VPI) defined as (Vmax - Vmin) / Vmax was calculated. ROC curve analysis was used to calculate AUC as a measure of accuracy to determine the value of this index for diagnosis of high-risk NAFLD and compared with that of the following four clinical decision aids: NAFLD fibrosis score (FS), fibrosis-4 index (FIB-4), BARD score (body mass index, aspartate aminotransferase [AST]-to-alanine aminotransferase ratio, diabetes mellitus), and AST-to-platelet ratio index (APRI). The value of adding VPI to these indexes was also investigated. RESULTS. Of 123 study subjects, 33 (26.8%) had high-risk NAFLD and were found to have a lower VPI than the other 90 subjects (0.19 vs 0.32; p < 0.001). VPI, NAFLD FS, FIB-4, and APRI had statistically significant diagnostic values for high-risk NAFLD. VPI had the highest optimism-corrected AUC (VPI, 0.84 [95% CI, 0.77-0.91]; NAFLD FS, 0.74 [95% CI, 0.63-0.83]; FIB-4, 0.81 [95% CI, 0.72-0.89]; APRI, 0.73 [95% CI, 0.61-0.82]). Addition of VPI to any of the four scoring systems significantly improved the diagnostic value of the score for high-risk NAFLD. CONCLUSION. VPI may be an accurate noninvasive biomarker for diagnosis of high-risk NAFLD.


Assuntos
Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Veia Porta/fisiopatologia , Fluxo Pulsátil , Ultrassonografia Doppler Dupla , Adulto , Idoso , Biomarcadores/análise , Biópsia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
4.
J Ultrasound Med ; 38(1): 103-111, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29761535

RESUMO

OBJECTIVES: To assess performance of shear wave elastography for evaluation of fibrosis and the histologic stage in patients with autoimmune liver disease (ALD) and to validate previously established advanced fibrosis cutoff values in this cohort. METHODS: Shear wave elastography was performed on patients with ALD with an Aixplorer ultrasound system (SuperSonic Imagine, Aix-en-Provence, France) using an SC6-1 transducer. The median estimated tissue Young modulus was calculated from sets of 8 to 10 elastograms. A blinded, subspecialty-trained pathologist reviewed biopsy specimens. The METAVIR classification was used to stage liver fibrosis and necroinflammation. Steatosis was graded from 0 to 4+. The Kendall τ-b correlation test was performed to identify the correlation between the estimated tissue Young modulus and fibrosis, steatosis, and the necroinflammatory score. The Spearman correlation test was performed to identify the correlation between the estimated tissue Young modulus and clinical data. The diagnostic performance of shear wave elastography for differentiating METAVIR stage F2 or higher from F0 and F1 fibrosis was evaluated by a receiver operating characteristic (ROC) curve analysis. RESULTS: Fifty-one patients with ALD were analyzed. The estimated tissue Young modulus was positively correlated with the fibrosis stage and necroinflammation score (r = 0.386; P < .001; r = 0.338; P = .002, respectively) but not steatosis (r = -0.091; P = .527). Serum aspartate aminotransferase, alanine aminotransferase, and total bilirubin values were positively correlated with the estimated tissue Young modulus (r = 0.501; P < .001; r = 0.44; P = .001; r = 0.291; P = .038). The serum albumin value was negatively correlated (r = -0.309; P = .033). The area under the ROC curve was 0.781 (95% confidence interval, 0.641-0.921) for distinguishing F2 or greater fibrosis from F0 and F1 fibrosis. Based on the ROC curve, an optimal cutoff value of 9.15 kPa was identified (sensitivity, 83.3%; specificity, 72.7%). CONCLUSIONS: Shear wave elastography is a novel noninvasive adjunct to liver biopsy in evaluation and staging of patients with ALD, showing the potential for serial evaluations of disease progression and treatment responses.


Assuntos
Doenças Autoimunes/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Hepatopatias/diagnóstico por imagem , Doenças Autoimunes/complicações , Doenças Autoimunes/patologia , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Hepatopatias/complicações , Hepatopatias/patologia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença
5.
AJR Am J Roentgenol ; 206(3): 609-16, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26901019

RESUMO

OBJECTIVE: The purpose of this study is to determine the reliability of shear-wave elastographic estimates of the Young modulus in thyroid follicular neoplasms. SUBJECTS AND METHODS: In this study, 35 adults with follicular nodules diagnosed by fine-needle aspiration (FNA) biopsy were enrolled. A single sonographer examined all nodules in three planes (sagittal, transverse, and transverse center). Two raters independently placed ROIs in each nodule. Intra- and interrater reliability were computed as intraclass correlation coefficients (ICCs) and were reported using the Guidelines for Reporting Reliability and Agreement Studies. RESULTS: Thirty-five subjects with 35 follicular pattern nodules diagnosed by FNA biopsy were enrolled; 23 (65.7%) patients were female, with a mean age of 55.1 years (range, 23-85 years). For rater 1, intrarater agreement showed ICCs for single measurements of 0.87, 0.87, and 0.90 in the sagittal, transverse, and transverse center plans, respectively; ICCs for the median of multiple measurements were 0.97, 0.94, and 0.96 in the sagittal, transverse, and transverse center planes, respectively. For rater 2, intrarater agreement showed ICCs for single measurements of 0.94, 0.86, and 0.92 in the sagittal, transverse, and transverse center planes, respectively; ICCs for the median of multiple measurements were 0.97, 0.92, and 0.96 in the sagittal, transverse, and transverse center planes, respectively. Interrater agreement between measurements performed for the same subject showed ICCs for single measurements of 0.87, 0.87, and 0.80 in the sagittal, transverse, and transverse center planes, respectively; ICCs for the median of multiple measurements were 0.96, 0.93, and 0.92 in the sagittal, transverse, and transverse center planes, respectively. CONCLUSION: ROI placement is a reliable method for estimating the Young modulus of tissue in follicular thyroid nodules.


Assuntos
Adenocarcinoma Folicular/diagnóstico por imagem , Módulo de Elasticidade , Técnicas de Imagem por Elasticidade , Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Adenocarcinoma Folicular/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha Fina , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/patologia , Adulto Jovem
7.
Radiology ; 277(2): 565-73, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25955578

RESUMO

PURPOSE: To evaluate the diagnostic accuracy of shear-wave elastography (SWE) for the diagnosis of malignancy in follicular lesions and to identify the optimal SWE measurement plane. MATERIALS AND METHODS: The institutional review board approved this HIPAA-compliant, single-institution, prospective pilot study. Subjects scheduled for surgery after a previous fine-needle aspiration report of "atypia of undetermined significance" or "follicular lesion of undetermined significance," "suspicion for follicular neoplasm," or "suspicion for Hurthle cell neoplasm," were enrolled after obtaining informed consent. Subjects underwent conventional ultrasonography (US), Doppler evaluation, and SWE preoperatively, and their predictive value for thyroid malignancy was evaluated relative to the reference standard of surgical pathologic findings. RESULTS: Thirty-five patients (12 men, 23 women) with a mean age of 55 years (range, 23-85 years) and a fine-needle aspiration diagnosis of atypia of undetermined significance or follicular lesion of undetermined significance (n = 16), suspicion for follicular neoplasm (n = 14), and suspicion for Hurthle cell neoplasm (n = 5) were enrolled in the study. Male sex was a statistically significant (P = .02) predictor of malignancy, but age was not. No sonographic morphologic parameter, including nodule size, microcalcification, macrocalcification, halo sign, taller than wide dimension, or hypoechogenicity, was associated with malignancy. Similarly, no Doppler feature, including intranodular vascularity, pulsatility index, resistive index, or peak-systolic velocity, was associated with malignancy. Higher median SWE tissue Young modulus estimates from the transverse insonation plane were associated with malignancy, yielding an area under the receiver operating characteristic curve of 0.81 (95% confidence interval: 0.62, 1.00) for differentiation of malignant from benign nodules. At a cutoff value of 22.3 kPa, sensitivity, specificity, positive predictive value, and negative predictive value of 82%, 88%, 75%, and 91%, respectively, were observed. CONCLUSION: This prospective pilot study indicates that SWE may be a valuable tool in preoperative malignancy risk assessment of follicular-patterned thyroid nodules.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Doenças da Glândula Tireoide/diagnóstico por imagem , Adenocarcinoma Folicular/diagnóstico por imagem , Adenocarcinoma Folicular/patologia , Adenoma/diagnóstico por imagem , Adenoma/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha Fina , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Estudos Prospectivos , Medição de Risco , Doenças da Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia
8.
Radiology ; 274(3): 888-96, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25393946

RESUMO

PURPOSE: To evaluate the accuracy of shear-wave elastography (SWE) for staging liver fibrosis in patients with diffuse liver disease (including patients with hepatitis C virus [HCV]) and to determine the relative accuracy of SWE measurements obtained from different hepatic acquisition sites for staging liver fibrosis. MATERIALS AND METHODS: The institutional review board approved this single-institution prospective study, which was performed between January 2010 and March 2013 in 136 consecutive patients who underwent SWE before their scheduled liver biopsy (age range, 18-76 years; mean age, 49 years; 70 men, 66 women). Informed consent was obtained from all patients. SWE measurements were obtained at four sites in the liver. Biopsy specimens were reviewed in a blinded manner by a pathologist using METAVIR criteria. SWE measurements and biopsy results were compared by using the Spearman correlation and receiver operating characteristic (ROC) curve analysis. RESULTS: SWE values obtained at the upper right lobe showed the highest correlation with estimation of fibrosis (r = 0.41, P < .001). Inflammation and steatosis did not show any correlation with SWE values except for values from the left lobe, which showed correlation with steatosis (r = 0.24, P = .004). The area under the ROC curve (AUC) in the differentiation of stage F2 fibrosis or greater, stage F3 fibrosis or greater, and stage F4 fibrosis was 0.77 (95% confidence interval [CI]: 0.68, 0.86), 0.82 (95% CI: 0.75, 0.91), and 0.82 (95% CI: 0.70, 0.95), respectively, for all subjects who underwent liver biopsy. The corresponding AUCs for the subset of patients with HCV were 0.80 (95% CI: 0.67, 0.92), 0.82 (95% CI: 0.70, 0.95), and 0.89 (95% CI: 0.73, 1.00). The adjusted AUCs for differentiating stage F2 or greater fibrosis in patients with chronic liver disease and those with HCV were 0.84 and 0.87, respectively. CONCLUSION: SWE estimates of liver stiffness obtained from the right upper lobe showed the best correlation with liver fibrosis severity and can potentially be used as a noninvasive test to differentiate intermediate degrees of liver fibrosis in patients with liver disease.


Assuntos
Técnicas de Imagem por Elasticidade , Cirrose Hepática/diagnóstico por imagem , Adolescente , Adulto , Idoso , Doença Crônica , Feminino , Humanos , Cirrose Hepática/complicações , Hepatopatias/complicações , Hepatopatias/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
10.
Abdom Imaging ; 40(4): 709-22, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25750099

RESUMO

This article reviews the clinical applications of current ultrasound elastography methods in non-hepatic conditions including thyroid nodules, prostate cancer, chronic kidney disease, solid renal lesions, pancreatic lesions, and deep vein thrombosis. Pathophysiology alters tissue mechanical properties via ultrastructural changes including fibrosis, increased cellularity, bleeding, and necrosis, creating a target biomarker, which can be imaged qualitatively or quantitatively with US elastography. US elastography methods can add information to conventional US methods and improve the diagnostic performance of conventional US in a range of disease processes.


Assuntos
Técnicas de Imagem por Elasticidade , Nefropatias/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Nódulo da Glândula Tireoide/diagnóstico por imagem , Trombose Venosa/diagnóstico por imagem , Humanos , Rim/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Masculino , Pâncreas/diagnóstico por imagem , Próstata/diagnóstico por imagem , Insuficiência Renal Crônica/diagnóstico por imagem , Sensibilidade e Especificidade , Glândula Tireoide/diagnóstico por imagem
11.
Abdom Imaging ; 40(4): 698-708, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25690689

RESUMO

Ultrasound elastography, also termed sonoelastography, is being used increasingly in clinical practice to aid the diagnosis and management of diffuse liver disease. Elastography has been shown to be capable of differentiating advanced and early-stage liver fibrosis, and consequently a major application in clinical liver care includes progression to cirrhosis risk stratification through (1) assessment of liver fibrosis stage in HCV and HBV patients, (2) distinguishing non-alcoholic steatohepatitis from simple steatosis in non-alcoholic fatty liver disease patients, and (3) prognostic evaluation of liver disease is autoimmune liver disease. In addition, elastographic characterization of focal liver lesions and evaluation of clinically significant portal hypertension have the potential to be clinically useful and are areas of active clinical research.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatopatias/diagnóstico por imagem , Humanos , Fígado/diagnóstico por imagem
12.
Abdom Imaging ; 40(8): 3078-83, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26254907

RESUMO

Amyloidosis is extremely rare, with an estimated 2225 new US cases reported annually. Signs and symptoms of the disease are subtle and imaging findings are not pathognomonic. Currently, diagnosis requires biopsy to demonstrate the deposition of amyloid. Elastography is a new imaging modality that evaluates tissue elasticity. It has shown to have efficacy in characterizing thyroid nodules, detecting prostate cancer, and staging liver fibrosis. We present a case of hepatic amyloidosis in a 51-year-old male that demonstrates significantly increased stiffness with a median value of 99.1 kPa (range 25.7-188.9 kPa) on shear-wave elastography (SWE) imaging, which is significantly higher than the cut-off range reported for cirrhosis on SWE (10.4-11.5 kPa). This finding raises the possibility that elastographic imaging may be sensitive to tissue mechanical changes induced by amyloid deposition.


Assuntos
Amiloidose/diagnóstico por imagem , Técnicas de Imagem por Elasticidade , Hepatopatias/diagnóstico por imagem , Fígado/diagnóstico por imagem , Amiloidose/patologia , Biópsia , Diagnóstico Diferencial , Humanos , Fígado/patologia , Hepatopatias/patologia , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
13.
BMC Nephrol ; 16: 119, 2015 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-26227484

RESUMO

BACKGROUND: There currently is a need for a non-invasive measure of renal fibrosis. We aim to explore whether shear wave elastography (SWE)-derived estimates of tissue stiffness may serve as a non-invasive biomarker that can distinguish normal and abnormal renal parenchymal tissue. METHODS: Participants with CKD (by estimated GFR) and healthy volunteers underwent SWE. Renal elasticity was estimated as Young's modulus (YM) in kilopascals (kPa). Univariate Wilcoxon rank-sum tests were used. RESULTS: Twenty-five participants with CKD (median GFR 38 mL/min; quartile 1, quartile 3 28, 42) and 20 healthy controls without CKD underwent SWE performed by a single radiologist. CKD was associated with increased median YM (9.40 [5.55, 22.35] vs. 4.40 [3.68, 5.70] kPa; p = 0.002) and higher median intra-subject inter-measurement estimated YM's variability (4.27 [2.89, 9.90] vs. 1.51 [1.21, 2.05] kPa; p < 0.001). CONCLUSIONS: SWE-derived estimates of renal stiffness and intra-subject estimated stiffness variability are higher in patients with CKD than in healthy controls. Renal fibrosis is a plausible explanation for the observed difference in YM. Further studies are required to determine the relationship between YM, estimated renal stiffness, and renal fibrosis severity.


Assuntos
Módulo de Elasticidade , Rim/diagnóstico por imagem , Insuficiência Renal Crônica/diagnóstico por imagem , Adulto , Idoso , Estudos de Casos e Controles , Estudos Transversais , Elasticidade , Técnicas de Imagem por Elasticidade , Feminino , Fibrose , Humanos , Rim/patologia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Insuficiência Renal Crônica/patologia
14.
Abdom Radiol (NY) ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38884782

RESUMO

Contrast-enhanced ultrasound (CEUS) is an advanced ultrasound (US) technique utilizing ultrasound contrast agents (UCAs) to provide detailed visualization of anatomic and vascular architecture, including the depiction of microcirculation. CEUS has been well-established in echocardiography and imaging of focal hepatic lesions and recent studies have also shown the utility of CEUS in non-hepatic applications like the urinary system. The updated guidelines by the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) from 2018 describe the use of CEUS for non-hepatic applications. CEUS' excellent safety profile and spatial resolution make it a superior modality to conventional US and is often comparable and even superior to CECT in some instances. In comparison to other cross-sectional imaging modalities such as CECT or MRI, CEUS offers a safe (by virtue of non-nephrotoxic US contrast agents), accurate, cost-efficient, readily available, and a quick means of evaluation of multiple pathologies of the urinary system. CEUS also has the potential to reduce the overall economic burden on patients requiring long-term follow-up due to its low cost as compared to CT or MRI techniques. This comprehensive review focuses on the applications of CEUS in evaluating the urinary system from the kidneys to the urinary bladder. CEUS can be utilized in the kidney to evaluate complex cystic lesions, indeterminate lesions, pseudotumors (vs solid renal tumors), renal infections, and renal ischemic disorders. Additionally, CEUS has also been utilized in evaluating renal transplants. In the urinary bladder, CEUS is extremely useful in differentiating a bladder hematoma and bladder cancer when conventional US techniques show equivocal results. Quantitative parameters of time-intensity curves (TICs) of CEUS examinations have also been studied to stage and grade bladder cancers. Although promising, further research is needed to definitively stage bladder cancers and classify them as muscle-invasive or non-muscle invasive using quantitative CEUS to guide appropriate intervention. CEUS has been very effective in the classification of cystic renal lesions, however, further research is needed in differentiating benign from malignant renal masses.

15.
J Imaging Inform Med ; 37(2): 873-883, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38319438

RESUMO

This study aims to develop a semiautomated pipeline and user interface (LiVaS) for rapid segmentation and labeling of MRI liver vasculature and evaluate its time efficiency and accuracy against manual reference standard. Retrospective feasibility pilot study. Liver MR images from different scanners from 36 patients were included, and 4/36 patients were randomly selected for manual segmentation as referenced standard. The liver was segmented in each contrast phase and masks registered to the pre-contrast segmentation. Voxel-wise signal trajectories were clustered using the k-means algorithm. Voxel clusters that best segment the liver vessels were selected and labeled by three independent radiologists and a research scientist using LiVaS. Segmentation times were compared using a paired-sample t-test on log-transformed data. The agreement was analyzed qualitatively and quantitatively using DSC for hepatic and portal vein segmentations. The mean segmentation time among four readers was significantly shorter than manual (3.6 ± 1.4 vs. 70.0 ± 29.2 min; p < 0.001), even when using a higher number of clusters to enhance accuracy. The DSC for portal and hepatic veins reached up to 0.69 and 0.70, respectively. LiVaS segmentations were overall of good quality, with variations in performance related to the presence/severity of liver disease, acquisition timing, and image quality. Our semi-automated pipeline was robust to different MRI vendors in producing segmentation and labeling of liver vasculature in agreement with expert manual annotations, with significantly higher time efficiency. LiVaS could facilitate the creation of large, annotated datasets for training and validation of neural networks for automated MRI liver vascularity segmentation. HIGHLIGHTS: Key Finding: In this pilot feasibility study, our semiautomated pipeline for segmentation of liver vascularity (LiVaS) on MR images produced segmentations with simultaneous labeling of portal and hepatic veins in good agreement with the manual reference standard but at significantly shorter times (mean LiVaS 3.6 ± 1.4 vs. mean manual 70.0 ± 29.2 min; p < 0.001). Importance: LiVaS was robust in producing liver MRI vascular segmentations across images from different scanners in agreement with expert manual annotations, with significant ly higher time efficiency, and therefore potential scalability.

16.
AJR Am J Roentgenol ; 201(6): 1335-9, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24261375

RESUMO

OBJECTIVE: Fine-needle aspiration biopsy (FNAB) is the current primary test to risk stratify thyroid nodules. However, in up to one third of biopsies, cytology is indeterminate. The Bethesda System for Reporting Thyroid Cytopathology categorizes thyroid cytology findings into six groups, with each group assigned a putative malignancy risk. This article reviews the Bethesda System, emphasizing the key facts necessary to understand thyroid biopsy results and effectively manage patients after FNAB. CONCLUSION: It is important to diagnose and stratify the risk of malignancy in thyroid nodules. A working knowledge of the Bethesda System permits accurate, evidence-based risk stratification of patients with thyroid nodules and thereby facilitates their management. Because it is a uniform diagnostic approach, the Bethesda System allows comparisons of different management strategies across different institutions.


Assuntos
Biópsia por Agulha Fina , Neoplasias da Glândula Tireoide/patologia , Ultrassonografia de Intervenção , Citodiagnóstico/métodos , Humanos , Neoplasias da Glândula Tireoide/classificação , Neoplasias da Glândula Tireoide/diagnóstico por imagem
17.
AJR Am J Roentgenol ; 201(6): W893-9, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24261396

RESUMO

OBJECTIVE: The purpose of this study was to classify noncystic splenic lesions detected on imaging in young patients (0-30 years) and to determine the optimal imaging workup for such lesions. MATERIALS AND METHODS: This study was conducted at three academic institutions by performing a database search of radiology reports (2002-2011) to identify patients with noncystic splenic lesions. Medical records were then searched to identify radiology examination indications, clinical follow-up, and lesion changes on subsequent imaging. All lesions had either definitive diagnosis (histopathology or laboratory results consistent with infectious cause) or lesion stability more than 2 years consistent with a benign cause. RESULTS: Benign (n = 32), benign indeterminate (n = 7), and malignant (n = 14) lesions were identified in 53 patients (26 males and 27 females; mean age, 19 years; age range, 1 month-30 years). Lesions were initially detected on the following imaging modalities: CT (n = 27), ultrasound (n = 12), MRI (n = 6), and PET/CT (n = 8). A total of 14 patients underwent MRI for lesion characterization, and 12 underwent PET/CT. MRI permitted definitive characterization of benign lesions in 10 of 14 (72%) patients, whereas PET/CT was used to diagnose nine of nine (100%) malignant splenic lesions and helped exclude malignancy in two of three benign lesions. CONCLUSION: Contrast-enhanced MRI is recommended for imaging workup of noncystic splenic lesions discovered in young patients because it can enable definitive diagnosis of most benign lesions. Lesions with indeterminate MRI features can be followed-up with ultrasound or CT. PET or PET/CT is recommended for patients with clinical evidence of malignancy but is less helpful for characterization of isolated splenic lesions.


Assuntos
Algoritmos , Diagnóstico por Imagem , Esplenopatias/diagnóstico , Adolescente , Adulto , Criança , Pré-Escolar , Meios de Contraste , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Esplenopatias/patologia
18.
J Pharmacol Exp Ther ; 334(2): 381-94, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20484155

RESUMO

Stomach ulceration is a major side effect of most chemopreventive drugs. We have established that although resveratrol is a promising chemopreventive compound, it delays the ulcer healing process. However, its analog hydroxystilbene-1 (HST-1) was devoid of such an ulcerogenic side effect. Consequently, here we tried to explore the chemopreventive efficacy of HST-1 compared with resveratrol in different cancer cell lines and identified the probable signaling pathways responsible for cell death. Our cell viability study established that HST-1, compared with resveratrol, showed better chemopreventive potential in all of the cell lines tested, with U937 and MCF-7 being the cells most affected. Furthermore, in U937 and MCF-7 cell lines, terminal deoxynucleotidyl transferase dUTP nick end labeling assay, cell cycle analysis, and nuclear fragmentation by confocal microscopy established that both HST-1 and resveratrol switched on the apoptotic death cascade to execute cell death. The initiator signal was Fas-independent but synchronized in terms of cytosolic Ca(2+) influx, dissipation of mitochondrial membrane potential, and oxidative burst. It is noteworthy that the executioner signal was cell-specific as in U937 cells; HST-1 and resveratrol treatment induced mitochondrial permealization followed by cardiolipin depletion and cytochrome c release, which eventually activated downstream caspases 9 and 3 to execute the death process. In contrast, in MCF-7 cells the death process was executed in a caspase-independent but calpain-dependent manner as calpain activation induced cleavage of cytosolic alpha-fodrin, stimulated mitochondrial release of apoptotic inducing factor and endonuclease G, and thus harmonized cytosolic and mitochondrial death signals to accomplish apoptosis.


Assuntos
Anticarcinógenos/farmacologia , Apoptose/efeitos dos fármacos , Calpaína/fisiologia , Caspases/fisiologia , Estilbenos/farmacologia , Apoptose/fisiologia , Cálcio/metabolismo , Cardiolipinas/metabolismo , Linhagem Celular Tumoral , Citocromos c/metabolismo , Citosol/metabolismo , Humanos , Potencial da Membrana Mitocondrial/efeitos dos fármacos , Proteínas de Transporte da Membrana Mitocondrial/fisiologia , Poro de Transição de Permeabilidade Mitocondrial , Espécies Reativas de Oxigênio/metabolismo , Explosão Respiratória , Resveratrol , Transdução de Sinais
19.
Ultrasound Med Biol ; 46(10): 2667-2676, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32622685

RESUMO

The purpose of this study was to develop an automated method for classifying liver fibrosis stage ≥F2 based on ultrasound shear wave elastography (SWE) and to assess the system's performance in comparison with a reference manual approach. The reference approach consists of manually selecting a region of interest from each of eight or more SWE images, computing the mean tissue stiffness within each of the regions of interest and computing a resulting stiffness value as the median of the means. The 527-subject database consisted of 5526 SWE images and pathologist-scored biopsies, with data collected from a single system at a single site. The automated method integrates three modules that assess SWE image quality, select a region of interest from each SWE measurement and perform machine learning-based, multi-image SWE classification for fibrosis stage ≥F2. Several classification methods were developed and tested using fivefold cross-validation with training, validation and test sets partitioned by subject. Performance metrics were area under receiver operating characteristic curve (AUROC), specificity at 95% sensitivity and number of SWE images required. The final automated method yielded an AUROC of 0.93 (95% confidence interval: 0.90-0.94) versus 0.69 (95% confidence interval: 0.65-0.72) for the reference method, 71% specificity with 95% sensitivity versus 5% and four images per decision versus eight or more. In conclusion, the automated method reported in this study significantly improved the accuracy for ≥F2 classification of SWE measurements as well as reduced the number of measurements needed, which has the potential to reduce clinical workflow.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Processamento de Imagem Assistida por Computador , Cirrose Hepática/classificação , Cirrose Hepática/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
20.
Ultrasound Med Biol ; 46(4): 972-980, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32005510

RESUMO

In this study, we evaluated the diagnostic accuracy of shear wave elastography (SWE) for differentiating high-risk non-alcoholic steatohepatitis (hrNASH) from non-alcoholic fatty liver and low-risk non-alcoholic steatohepatitis (NASH). Patients with non-alcoholic fatty liver disease scheduled for liver biopsy underwent pre-biopsy SWE. Ten SWE measurements were obtained. Biopsy samples were reviewed using the NASH Clinical Research Network Scoring System and patients with hrNASH were identified. Receiver operating characteristic curves for SWE-based hrNASH diagnosis were charted. One hundred sixteen adult patients underwent liver biopsy at our institution for the evaluation of non-alcoholic fatty liver disease. The area under the receiver operating characteristic curve of SWE for hrNASH diagnosis was 0.73 (95% confidence interval: 0.61-0.84, p < 0.001). The Youden index-based optimal stiffness cutoff value for hrNASH diagnosis was calculated as 8.4 kPa (1.67 m/s), with a sensitivity of 77% and specificity of 66%. SWE may be useful for the detection of NASH patients at risk of long-term liver-specific morbidity and mortality.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Fígado/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Biomarcadores , Biópsia com Agulha de Grande Calibre , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/diagnóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA