Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Chem Rev ; 122(4): 4636-4699, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-35077645

RESUMO

Bioelectronic transducing surfaces that are nanometric in size have been the main route to detect single molecules. Though enabling the study of rarer events, such methodologies are not suited to assay at concentrations below the nanomolar level. Bioelectronic field-effect-transistors with a wide (µm2-mm2) transducing interface are also assumed to be not suited, because the molecule to be detected is orders of magnitude smaller than the transducing surface. Indeed, it is like seeing changes on the surface of a one-kilometer-wide pond when a droplet of water falls on it. However, it is a fact that a number of large-area transistors have been shown to detect at a limit of detection lower than femtomolar; they are also fast and hence innately suitable for point-of-care applications. This review critically discusses key elements, such as sensing materials, FET-structures, and target molecules that can be selectively assayed. The amplification effects enabling extremely sensitive large-area bioelectronic sensing are also addressed.


Assuntos
Técnicas Biossensoriais , Transistores Eletrônicos , Técnicas Biossensoriais/métodos , Nanotecnologia
2.
Anal Bioanal Chem ; 414(18): 5657-5669, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35410389

RESUMO

Early diagnosis in a premalignant (or pre-invasive) state represents the only chance for cure in neoplastic diseases such as pancreatic-biliary cancer, which are otherwise detected at later stages and can only be treated using palliative approaches, with no hope for a cure. Screening methods for the purpose of secondary prevention are not yet available for these cancers. Current diagnostic methods mostly rely on imaging techniques and conventional cytopathology, but they do not display adequate sensitivity to allow valid early diagnosis. Next-generation sequencing can be used to detect DNA markers down to the physical limit; however, this assay requires labeling and is time-consuming. The additional determination of a protein marker that is a predictor of aggressive behavior is a promising innovative approach, which holds the potential to improve diagnostic accuracy. Moreover, the possibility to detect biomarkers in blood serum offers the advantage of a noninvasive diagnosis. In this study, both the DNA and protein markers of pancreatic mucinous cysts were analyzed in human blood serum down to the single-molecule limit using the SiMoT (single-molecule assay with a large transistor) platform. The SiMoT device proposed herein, which exploits an inkjet-printed organic semiconductor on plastic foil, comprises an innovative 3D-printed sensing gate module, consisting of a truncated cone that protrudes from a plastic substrate and is compatible with standard ELISA wells. This 3D gate concept adds tremendous control over the biosensing system stability, along with minimal consumption of the capturing molecules and body fluid samples. The 3D sensing gate modules were extensively characterized from both a material and electrical perspective, successfully proving their suitability as detection interfaces for biosensing applications. KRAS and MUC1 target molecules were successfully analyzed in diluted human blood serum with the 3D sensing gate functionalized with b-KRAS and anti-MUC1, achieving a limit of detection of 10 zM and 40 zM, respectively. These limits of detection correspond to (1 ± 1) KRAS and (2 ± 1) MUC1 molecules in the 100 µL serum sample volume. This study provides a promising application of the 3D SiMoT platform, potentially facilitating the timely, noninvasive, and reliable identification of pancreatic cancer precursor cysts.


Assuntos
Cisto Pancreático , Proteínas Proto-Oncogênicas p21(ras) , Biomarcadores , Humanos , Cisto Pancreático/diagnóstico , Cisto Pancreático/metabolismo , Cisto Pancreático/patologia , Neoplasias Pancreáticas , Plásticos , Impressão Tridimensional , Neoplasias Pancreáticas
3.
Int J Mol Sci ; 23(24)2022 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-36555460

RESUMO

Thin self-standing films with potential antimicrobial synergistic activity have been produced by a simple green chemical synthesis with overnight thermal treatment. Their properties have been studied by scanning electron microscopy, X-ray photoelectron spectroscopy and other techniques to understand their potential range of applications. In this work, the focus was set on the development of a potential novel and effective alternative to conventional antimicrobial materials. By creating an antimicrobial polymer blend, and using it to develop and immobilize fine (~25 nm) silver nanophases, we further aimed to exploit its film-forming properties and create a solid composite material. The resulting polymer matrix showed improved water uptake percentage and better stability in the presence of water. Moreover, the antimicrobial activity of the films, which is due to both organic and inorganic components, has been evaluated by Kirby-Bauer assay against common foodborne pathogens (Staphylococcus aureus and Salmonella enterica) and resulted in a clear inhibition zone of 1.2 cm for the most complex nanocomposition. The excellent performance against bacteria of fresh and 6-month-old samples proves the prospects of this material for the development of smart and biodegradable food packaging applications.


Assuntos
Anti-Infecciosos , Quitosana , Nanopartículas Metálicas , Polímeros/farmacologia , Prata/farmacologia , Prata/química , Antibacterianos/farmacologia , Antibacterianos/química , Nanopartículas Metálicas/química , Anti-Infecciosos/farmacologia , Anti-Infecciosos/química , Embalagem de Alimentos/métodos , Água , Quitosana/química
4.
Anal Bioanal Chem ; 412(4): 811-818, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31865415

RESUMO

Early diagnosis of the infection caused by human immunodeficiency virus type-1 (HIV-1) is vital to achieve efficient therapeutic treatment and limit the disease spreading when the viremia is at its highest level. To this end, a point-of-care HIV-1 detection carried out with label-free, low-cost, and ultra-sensitive screening technologies would be of great relevance. Herein, a label-free single molecule detection of HIV-1 p24 capsid protein with a large (wide-field) single-molecule transistor (SiMoT) sensor is proposed. The system is based on an electrolyte-gated field-effect transistor whose gate is bio-functionalized with the antibody against the HIV-1 p24 capsid protein. The device exhibits a limit of detection of a single protein and a limit of quantification in the 10 molecule range. This study paves the way for a low-cost technology that can quantify, with single-molecule precision, the transition of a biological organism from being "healthy" to being "diseased" by tracking a target biomarker. This can open to the possibility of performing the earliest possible diagnosis.


Assuntos
Técnicas Biossensoriais/instrumentação , Proteína do Núcleo p24 do HIV/análise , HIV-1/isolamento & purificação , Transistores Eletrônicos , Anticorpos Imobilizados/química , Infecções por HIV/diagnóstico , Infecções por HIV/virologia , Humanos , Imunoensaio/instrumentação , Limite de Detecção , Modelos Moleculares
5.
Anal Bioanal Chem ; 411(19): 4899-4908, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30923859

RESUMO

In the last decade, saliva has been suggested as non-invasive diagnostic fluid, suitable for clinical use alternatively to blood serum and plasma. However, the clinical applicability of saliva has been hampered so far by the inadequate sensitivity of current methods to detect the lower salivary concentrations of many biomarkers monitored in blood products. Herein, a label-free biosensor based on electrolyte-gated organic thin-film transistor (EGOTFT) has been developed for the detection at the physical limit of C-reactive protein (CRP) in human saliva. CRP is a key relevant biomarker for inflammatory processes and is routinely monitored for many clinical purposes. Herein, an electrolyte-gated thin-film transistor (EGOTFT) has been proposed as a transducer of the biorecognition event taking place at the gate electrode, functionalized with a self-assembled monolayer (SAM) of highly densely packed capturing anti-CRP proteins. Thanks to the SAM, the biosensing platform herein proposed is endowed with ultra-high sensitivity, along with an extremely high selectivity, assessed by measuring the dose curves of CRP interacting with a bovine serum albumin-functionalized gate. Moreover, the biosensing platform is compatible with low-cost fabrication techniques and applicable to the ultra-sensitive detection of a plethora of clinically relevant biomarkers. Therefore, the EGOTFT device herein proposed, being able to operate in physiologically relevant fluids such as saliva, will set the ground to a major revolution in biosensing applications for early clinical detection.


Assuntos
Proteína C-Reativa/análise , Técnicas Eletroquímicas/métodos , Saliva/química , Transistores Eletrônicos , Anticorpos/imunologia , Técnicas Biossensoriais/métodos , Proteína C-Reativa/imunologia , Eletrodos , Eletrólitos , Humanos , Limite de Detecção
6.
Mikrochim Acta ; 185(2): 153, 2018 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-29594679

RESUMO

Hybrids consisting of silver nanoparticles (in varying fractions) and of TiOx/ZnO were prepared via top-down ion beam sputtering (IBS) deposition on silicon substrates. The deposited nanomaterials were characterized by scanning electron microscopy and X-ray photoelectron spectroscopy. It is shown that such composites represent a viable substrate for use in both surface enhanced Raman spectroscopy (SERS) and surface enhanced infrared absorption spectroscopy (SEIRAS), as exemplarily shown for crystal violet as the model analyte. The C-H bending mode at about 1181 cm-1 and the C-N vibration at 1361 cm-1 observed in the SERS and SEIRAS spectra, respectively, have been used as analytical signal. The substrate consisting of TiOx NPs with 33% fraction of silver provides the strongest enhancement in SERS (up to 10,000-fold), while TiOx/AgNPs with thickness of 2 and 1 nm in ion beam sputtering, respectively, provides the best sensitivity in SEIRAS. The substrates also display photocatalytic activity as shown by the degradation of adsorbed crystal violet under ultraviolet irradiation. Graphical abstract Schematic of the preparation of hybrid substrates consisting of Ag and TiOx/ZnO nanoparticles via ion beam sputtering deposition. They were applied in both surface enhanced Raman and surface enhanced infrared absorption spectroscopies using crystal violet as model analyte, showing enhancements up to >10,000-fold in Raman.

7.
Phys Chem Chem Phys ; 19(31): 20573-20581, 2017 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-28730189

RESUMO

Electrical double layer (EDL) thin film transistors (TFTs) are an interesting class of transistors that use an electrolyte as the gating medium. Recently it has been demonstrated that pure organic solvents can also be used as gating media for TFTs without the addition of exogenous electrolytes. Here we present a systematic study of the performances of TFTs based on two different semiconductors (P3HT and ZnO) gated through nine different solvents either pure or loaded with NaCl. The nature of the solvent impacts the transfer characteristics of the TFT through a change in the gating capacitance while the threshold voltage remains unaffected. Depending on the polarity of solvents, addition of NaCl gives rise to different responses. TFTs gated through highly polar solvents are unaffected by the salt concentration while for low polarity solvents the output current increases with salt up to a plateau. Furthermore, when the semiconductor surface is covered with a high capacitance thin dielectric layer, the TFT output current becomes dependent on the NaCl concentration also for high polarity solvents. This phenomenology was rationalized considering the different contributions of Helmholtz and Guy-Chapman EDLs to the capacitance and the dielectric saturation that decreases the solvent dielectric constant within the Helmholtz EDL.

8.
Nanomedicine ; 13(3): 1245-1254, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28115254

RESUMO

Here, long-circulating behaviors of Inulin-based nanomicelles are demonstrated for the first time in vivo. We show the synthesis and evaluation of biotin (BIO)-decorated polymeric INVITE micelles constituted of substances of natural origin, Inulin (INU) and Vitamin E (VITE), as long-circulating carriers for receptor-mediated targeted drug delivery. The resulting INVITE or INVITE-BIO micelles, nanometrically sized, did not reveal any cytotoxicity after 24h of incubation with Caco-2 cells. Moreover, in vitro studies on Caco-2 cells monolayers indicated that the transport of INVITE-BIO micelles was faster than surface unmodified INVITE micelles. In vivo optical imaging studies evidenced that, upon intravenous administration, INVITE-BIO micelles were quantitatively present in the body up to 48h. Instead, after oral administration, the micelles were not found in the systemic circulation but eliminated with the normal intestinal content. In conclusion, INVITE-BIO micelles may enhance drug accumulation in tumor-cells over-expressing the receptor for biotin through receptor mediated endocytosis.


Assuntos
Biotina/farmacocinética , Portadores de Fármacos/farmacocinética , Inulina/farmacocinética , Micelas , Vitamina E/farmacocinética , Animais , Biotina/química , Células CACO-2 , Portadores de Fármacos/química , Sistemas de Liberação de Medicamentos , Feminino , Humanos , Inulina/química , Camundongos Endogâmicos BALB C , Imagem Óptica , Vitamina E/química
9.
Sensors (Basel) ; 14(9): 16869-80, 2014 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-25215940

RESUMO

Bottom- and top-contact organic thin film transistors (OTFTs) were fabricated, using poly(3-hexylthiophene-2,5-diyl) (P3HT) and poly[2,5-bis(3-tetradecylthiophen-2-yl)thieno[3,2-b]thiophene] (PBTTT-C16) as p-type channel semiconductors. Four different types of OTFTs were fabricated and investigated as gas sensors against three volatile organic compounds, with different associated dipole moments. The OTFT-based sensor responses were evaluated with static and transient current measurements. A comparison between the different architectures and the relative organic semiconductor was made.


Assuntos
Condutometria/instrumentação , Eletrodos , Gases/química , Membranas Artificiais , Polímeros/química , Tiofenos/química , Transistores Eletrônicos , Desenho de Equipamento , Análise de Falha de Equipamento , Compostos Orgânicos Voláteis/análise
10.
Adv Mater ; 36(13): e2309705, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38108547

RESUMO

Screening asymptomatic organisms (humans, animals, plants) with a high-diagnostic accuracy using point-of-care-testing (POCT) technologies, though still visionary holds great potential. Convenient surveillance requires easy-to-use, cost-effective, ultra-portable but highly reliable, in-vitro-diagnostic devices that are ready for use wherever they are needed. Currently, there are not yet such devices available on the market, but there are a couple more promising technologies developed at readiness-level 5: the Clustered-Regularly-Interspaced-Short-Palindromic-Repeats (CRISPR) lateral-flow-strip tests and the Single-Molecule-with-a-large-Transistor (SiMoT) bioelectronic palmar devices. They both hold key features delineated by the World-Health-Organization for POCT systems and an occurrence of false-positive and false-negative errors <1-5% resulting in diagnostic-selectivity and sensitivity >95-99%, while limit-of-detections are of few markers. CRISPR-strip is a molecular assay that, can detect down to few copies of DNA/RNA markers in blood while SiMoT immunometric and molecular test can detect down to a single oligonucleotide, protein marker, or pathogens in 0.1mL of blood, saliva, and olive-sap. These technologies can prospectively enable the systematic and reliable surveillance of asymptomatic ones prior to worsening/proliferation of illnesses allowing for timely diagnosis and swift prognosis. This could establish a proactive healthcare ecosystem that results in effective treatments for all living organisms generating diffuse and well-being at efficient costs.


Assuntos
Sistemas CRISPR-Cas , Saúde Única , Animais , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , RNA
11.
J Mater Chem C Mater ; 12(1): 73-79, 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-38143451

RESUMO

Kelvin probe force microscopy (KPFM) allows the detection of single binding events between immunoglobulins (IgM, IgG) and their cognate antibodies (anti-IgM, anti-IgG). Here an insight into the reliability and robustness of the methodology is provided. Our method is based on imaging the surface potential shift occurring on a dense layer of ∼5 × 107 antibodies physisorbed on a 50 µm × 90 µm area when assayed with increasing concentrations of antigens in phosphate buffer saline (PBS) standard solutions, in air and at a fixed scanning location. A comprehensive investigation of the influence of the main experimental parameters that may interfere with the outcomes of KPFM immune-assay is provided, showing the robustness and reliability of our approach. The data are supported also by a thorough polarization modulation infrared reflection-absorption spectroscopy (PM-IRRAS) analysis of the physisorbed biolayer, in the spectral region of the amide I, amide II and amide A bands. Our findings demonstrate that a 10 min incubation in 500 µL PBS encompassing ≈ 30 antigens (100 zM) triggers an extended surface potential shift that involves the whole investigated area. Such a shift quickly saturates at increasing ligand concentration, showing that the developed sensing platform works as an OFF/ON detector, capable of assessing the presence of a few specific biomarkers in a given assay volume. The reliability of the developed methodology KPFM is an important asset in single molecule detections at a wide electrode interface.

12.
Biosens Bioelectron ; 237: 115450, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37343312

RESUMO

Herein, we report a scalable benchtop electrode fabrication method to produce highly sensitive and flexible third-generation fructose dehydrogenase amperometric biosensors based on water-dispersed 0D-nanomaterials. The electrochemical platform was fabricated via Stencil-Printing (StPE) and insulated via xurography. Carbon black (CB) and mesoporous carbon (MS) were employed as 0D-nanomaterials promoting an efficient direct electron transfer (DET) between fructose dehydrogenase (FDH) and the transducer. Both nanomaterials were prepared in water-phase via a sonochemical approach. The nano-StPE exhibited enhanced electrocatalytic currents compared to conventional commercial electrodes. The enzymatic sensors were exploited for the determination of D-fructose in model solutions and various food and biological samples. StPE-CB and StPE-MS integrated biosensors showed appreciable sensitivity (∼150 µA cm-2 mM-1) with µmolar limit of detection (0.35 and 0.16 µM, respectively) and extended linear range (2-500 and 1-250 µM, respectively); the selectivity of the biosensors, ensured by the low working overpotential (+0.15 V), has been also demonstrated. Good accuracy (recoveries between 95 and 116%) and reproducibility (RSD ≤8.6%) were achieved for food and urine samples. The proposed approach because of manufacturing versatility and the electro-catalytic features of the water-nanostructured 0D-NMs opens new paths for affordable and customizable FDH-based bioelectronics.


Assuntos
Técnicas Biossensoriais , Frutose , Reprodutibilidade dos Testes , Técnicas Biossensoriais/métodos , Eletrodos , Oxirredutases , Água
13.
J Mater Chem C Mater ; 11(27): 9093-9106, 2023 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-37457868

RESUMO

Antibody physisorption at a solid interface is a very interesting phenomenon that has important effects on applications such as the development of novel biomaterials and the rational design and fabrication of high-performance biosensors. The strategy selected to immobilize biorecognition elements can determine the performance level of a device and one of the simplest approaches is physical adsorption, which is cost-effective, fast, and compatible with printing techniques as well as with green-chemistry processes. Despite its huge advantages, physisorption is very seldom adopted, as there is an ingrained belief that it does not lead to high performance because of its lack of uniformity and long-term stability, which, however, have never been systematically investigated, particularly for bilayers of capture antibodies. Herein, the homogeneity and stability of an antibody layer against SARS-CoV-2-Spike1 (S1) protein physisorbed onto a gold surface have been investigated by means of multi-parametric surface plasmon resonance (MP-SPR). A surface coverage density of capture antibodies as high as (1.50 ± 0.06) × 1012 molecules per cm-2 is measured, corresponding to a thickness of 12 ± 1 nm. This value is compatible with a single monolayer of homogeneously deposited antibodies. The effect of the ionic strength (is) of the antibody solution in controlling physisorption of the protein was thoroughly investigated, demonstrating an enhancement in surface coverage at lower ionic strength. An atomic force microscopy (AFM) investigation shows a globular structure attributed to is-related aggregations of antibodies. The long-term stability over two weeks of the physisorbed proteins was also assessed. High-performance sensing was proven by evaluating figures of merit, such as the limit of detection (2 nM) and the selectivity ratio between a negative control and the sensing experiment (0.04), which is the best reported performance for an SPR S1 protein assay. These figures of merit outmatch those measured with more sophisticated biofunctionalization procedures involving chemical bonding of the capture antibodies to the gold surface. The present study opens up interesting new pathways toward the achievement of a cost-effective and scalable biofunctionalization protocol, which could guarantee the prolonged stability of the biolayer and easy handling of the biosensing system.

14.
Adv Mater ; 35(42): e2304102, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37452695

RESUMO

A cohort of 47 patients is screened for pancreatic cancer precursors with a portable 96-well bioelectronic sensing-array for single-molecule assay in cysts fluid and blood plasma, deployable at point-of-care (POC). Pancreatic cancer precursors are mucinous cysts diagnosed with a sensitivity of at most 80% by state-of-the-art cytopathological molecular analyses (e.g., KRASmut DNA). Adding the simultaneous assay of proteins related to malignant transformation (e.g., MUC1 and CD55) is deemed essential to enhance diagnostic accuracy. The bioelectronic array proposed here, based on single-molecule-with-a-large-transistor (SiMoT) technology, can assay both nucleic acids and proteins at the single-molecule limit-of-identification (LOI) (1% of false-positives and false-negatives). It comprises an enzyme-linked immunosorbent assay (ELISA)-like 8 × 12-array organic-electronics disposable cartridge with an electrolyte-gated organic transistor sensor array, and a reusable reader, integrating a custom Si-IC chip, operating via software installed on a USB-connected smart device. The cartridge is complemented by a 3D-printed sensing gate cover plate. KRASmut , MUC1, and CD55 biomarkers either in plasma or cysts-fluid from 5 to 6 patients at a time, are multiplexed at single-molecule LOI in 1.5 h. The pancreatic cancer precursors are classified via a machine-learning analysis resulting in at least 96% diagnostic-sensitivity and 100% diagnostic-specificity. This preliminary study opens the way to POC liquid-biopsy-based early diagnosis of pancreatic-cancer precursors in plasma.


Assuntos
Cistos , Neoplasias Pancreáticas , Humanos , Proteínas Proto-Oncogênicas p21(ras)/genética , Detecção Precoce de Câncer , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/genética , Neoplasias Pancreáticas/metabolismo , Neoplasias Pancreáticas
15.
Anal Bioanal Chem ; 404(6-7): 1703-11, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22825677

RESUMO

Metal nanomaterials have an emerging role in surface-assisted laser desorption ionisation-mass spectrometry (SALDI-MS) providing a useful tool to overcome some limitations intrinsically related to the use of conventional organic matrices in matrix-assisted LDI-MS. In this contribution, the possibility to use a stainless-steel-supported gold nanoparticle (AuNP) film as a versatile platform for SALDI-MS was assessed. A sacrificial anode electrosynthetic route was chosen in order to obtain morphologically controlled core-shell AuNPs; the colloidal AuNPs were, thereafter, drop cast onto a stainless-steel sample plate and the resulting AuNP film was thermally annealed in order to improve its effectiveness as LDI-MS promoter. Spectroscopic characterization of the nanostructured film by X-ray photoelectron spectroscopy was crucial for understanding how annealing induced changes in the surface chemistry and influenced the performance of AuNPs as desorption/ionisation promoter. In particular, it was demonstrated that the post-deposition treatments were essential to enhance the AuNP core/analyte interaction, thus resulting in SALDI-MS spectra of significantly improved quality. The AuNP films were applied to the detection of three different classes of low molecular weight (LMW) analytes, i.e. amino acids, peptides and LMW polymers, in order to demonstrate the versatility of this nanostructured material.


Assuntos
Aminoácidos/análise , Peptídeos/análise , Polímeros/análise , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Ouro , Nanopartículas Metálicas/química , Peso Molecular , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação
16.
Adv Sci (Weinh) ; 9(30): e2203900, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36031404

RESUMO

Pathogens ultra-sensitive detection is vital for early diagnosis and provision of restraining actions and/or treatments. Among plant pathogens, Xylella fastidiosa is among the most threatening as it can infect hundreds of plant species worldwide with consequences on agriculture and the environment. An electrolyte-gated transistor is here demonstrated to detect X. fastidiosa at a limit-of-quantification (LOQ) of 2 ± 1 bacteria in 0.1 mL (20 colony-forming-unit per mL). The assay is carried out with a millimeter-wide gate functionalized with Xylella-capturing antibodies directly in saps recovered from naturally infected plants. The proposed platform is benchmarked against the quantitave polymerase chain reaction (qPCR) gold standard, whose LOQ turns out to be at least one order of magnitude higher. Furthermore, the assay selectivity is proven against the Paraburkholderia phytofirmans bacterium (negative-control experiment). The proposed label-free, fast (30 min), and precise (false-negatives, false-positives below 1%) electronic assay, lays the ground for an ultra-high performing immunometric point-of-care platform potentially enabling large-scale screening of asymptomatic plants.


Assuntos
Xylella , Doenças das Plantas , Plantas/microbiologia , Eletrônica
17.
ACS Sens ; 5(6): 1822-1830, 2020 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-32495625

RESUMO

The increasing interest in technologies capable of tracking a biomarker down to the physical limit points toward new opportunities in early diagnostics of progressive diseases. Indeed, single-molecule detection technologies are foreseen to enable clinicians to associate the tiniest increase in a biomarker with the progression of a disease, particularly at its early stage. Bioelectronic organic transistors represent an extremely powerful tool to achieve label-free and single-molecule detection of clinically relevant biomarkers. These electronic devices are millimetric in size and in the future could be mass-produced at low cost. The core of the single molecule with a large transistor (SiMoT) platform, based on an electrolyte-gated field-effect transistor, is a gold gate electrode biofunctionalized with a self-assembled monolayer, a densely packed layer of recognition elements. So far, only the SiMoT detection of proteins, using the corresponding antibodies as recognition elements, has been reported. In this study, the SiMoT sensing response toward genomic biomarkers is proposed. Herein, the gate is functionalized with a genomic biomarker for multiple sclerosis (miR-182). This is relevant, not only because a limit of detection of a single molecule is achieved but also because it proves that the SiMoT label-free, single-molecule detection principle is the only one of its kind that can detect, by means of the same platform, both protein and genomic markers.


Assuntos
Técnicas Biossensoriais , Transistores Eletrônicos , Biomarcadores , Genômica , Nanotecnologia
18.
Sensors (Basel) ; 9(12): 9616-28, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-22303143

RESUMO

The paper provides an overview on the use of photoacoustic sensors based on semiconductor laser sources for the detection of trace gases. We review the results obtained using standard, differential and quartz enhanced photoacoustic techniques.

19.
Sensors (Basel) ; 9(4): 2697-705, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-22574040

RESUMO

We report on the development of a photoacoustic sensor for the detection of formaldehyde (CH(2)O) using a thermoelectrically cooled distributed-feedback quantum cascade laser operating in pulsed mode at 5.6 µm. A resonant photoacoustic cell, equipped with four electret microphones, is excited in its first longitudinal mode at 1,380 Hz. The absorption line at 1,778.9 cm(-1) is selected for CH(2)O detection. A detection limit of 150 parts per billion in volume in nitrogen is achieved using a 10 seconds time constant and 4 mW laser power. Measurements in ambient air will require water vapour filters.

20.
Sensors (Basel) ; 9(5): 3337-56, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-22412315

RESUMO

Current production and emerging NO(x) sensors based on optical and nanomaterials technologies are reviewed. In view of their potential applications in mechatronics, we compared the performance of: i) Quantum cascade lasers (QCL) based photoacoustic (PA) systems; ii) gold nanoparticles as catalytically active materials in field-effect transistor (FET) sensors, and iii) functionalized III-V semiconductor based devices. QCL-based PA sensors for NO(x) show a detection limit in the sub part-per-million range and are characterized by high selectivity and compact set-up. Electrochemically synthesized gold-nanoparticle FET sensors are able to monitor NO(x) in a concentration range from 50 to 200 parts per million and are suitable for miniaturization. Porphyrin-functionalized III-V semiconductor materials can be used for the fabrication of a reliable NO(x) sensor platform characterized by high conductivity, corrosion resistance, and strong surface state coupling.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA