Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Neuroimage ; 226: 117286, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32992003

RESUMO

T2*-weighted gradient-echo sequences count among the most widely used techniques in neuroimaging and offer rich magnitude and phase contrast. The susceptibility effects underlying this contrast scale with B0, making T2*-weighted imaging particularly interesting at high field. High field also benefits baseline sensitivity and thus facilitates high-resolution studies. However, enhanced susceptibility effects and high target resolution come with inherent challenges. Relying on long echo times, T2*-weighted imaging not only benefits from enhanced local susceptibility effects but also suffers from increased field fluctuations due to moving body parts and breathing. High resolution, in turn, renders neuroimaging particularly vulnerable to motion of the head. This work reports the implementation and characterization of a system that aims to jointly address these issues. It is based on the simultaneous operation of two control loops, one for field stabilization and one for motion correction. The key challenge with this approach is that the two loops both operate on the magnetic field in the imaging volume and are thus prone to mutual interference and potential instability. This issue is addressed at the levels of sensing, timing, and control parameters. Performance assessment shows the resulting system to be stable and exhibit adequate loop decoupling, precision, and bandwidth. Simultaneous field and motion control is then demonstrated in examples of T2*-weighted in vivo imaging at 7T.


Assuntos
Artefatos , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Retroalimentação , Humanos , Movimento (Física)
2.
NMR Biomed ; 30(10)2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28678353

RESUMO

T2 * mapping offers access to a number of important structural and physiological tissue parameters. It is robust against RF field variations and overall signal scaling. However, T2 * measurement is highly sensitive to magnetic field errors, including perturbations caused by breathing motion at high baseline field. The goal of this work is to assess this issue in T2 * mapping of the brain and to study the benefit of field stabilization by feedback field control. T2 * quantification in the brain was investigated by phantom and in vivo measurements at 7 T. Repeated measurements were made with and without feedback field control using NMR field sensing and dynamic third-order shim actuation. The precision and reliability of T2 * quantification was assessed by studying variation across repeated measurements as well as fitting errors. Breathing effects were found to introduce significant error in T2 * mapping results. Field control mitigates this problem substantially. In a phantom it virtually eliminates the effects of emulated breathing fluctuations in the head. In vivo it enhances the structural fidelity of T2 * maps and reduces fitting residuals along with standard deviation. In conclusion, feedback field control improves the fidelity of T2 * mapping in the presence of field perturbations. It is an effective means of countering bulk susceptibility effects of breathing and hence holds particular promise for efforts to leverage high field for T2 * studies in vivo.


Assuntos
Retroalimentação , Imageamento por Ressonância Magnética/métodos , Adulto , Humanos , Masculino , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA