Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 179
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 101(4): 787-797, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36740229

RESUMO

AIMS: Early healing after drug-eluting stent (DES) implantation may reduce the risk of stent thrombosis. The aim of this study was to compare patterns of early healing after implantation of the thin strut everolimus-eluting Synergy DES (Boston Scientific) or the biolimus-eluting Biomatix Neoflex DES (Biosensors). METHODS AND RESULTS: A total of 160 patients with the chronic or acute coronary syndrome were randomized 1:1 to Synergy or Biomatrix DES. Optical coherence tomography (OCT) was performed at baseline and at either 1- or 3-month follow-up. The primary endpoint was a coronary stent healing index (CSHI), a weighted index of strut coverage, neointimal hyperplasia, malapposition, and extrastent lumen. A total of 133 cases had OCT follow-up and 119 qualified for matched OCT analysis. The median CSHI score did neither differ significantly between the groups at 1 month: Synergy 8.0 (interquartile range [IQR]: 3.0; 14.0) versus Biomatrix 8.5 (IQR: 4.0; 15.0) (p = 0.47) nor at 3 months: Synergy 6.5 (IQR: 2.0; 13.0) versus Biomatrix 6.0 (IQR: 4.0; 11.0) (p = 0.83). Strut coverage was 84.6% (IQR: 72.0; 97.9) for Synergy versus 77.6% (IQR: 70.1; 90.3) for Biomatrix (p = 0.15) at 1 month and 90.3% (IQR 79.0; 98.8) (Synergy) versus 83.9% (IQR: 77.5; 92.6) (Biomatrix) (p = 0.068) at 3 months. Pooled 1- and 3-month coverage was 88.6% (IQR: 74.4; 98.4) for Synergy compared with 80.7% (IQR: 73.2; 90.8) for Biomatrix (p = 0.02). CONCLUSIONS: The early healing response after treatment with the Synergy or Biomatrix DES did not differ significantly as determined by a healing index. The Synergy DES showed overall better early stent strut coverage.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Everolimo , Doença da Artéria Coronariana/terapia , Polímeros , Implantes Absorvíveis , Resultado do Tratamento , Desenho de Prótese , Tomografia de Coerência Óptica
2.
Artigo em Inglês | MEDLINE | ID: mdl-36519717

RESUMO

OBJECTIVES: The objective of the present study was to compare plaque burden (PB) calculated from optical coherence tomography (OCT) using deep learning (DL) with PB derived from co-registered intravascular ultrasound (IVUS). BACKGROUND: A DL algorithm was developed for automated plaque characterization and PB quantification from OCT images. However, the performance of this algorithm for PB quantification has not been validated. METHODS: Five-year follow-up OCT and IVUS images from 15 patients implanted with bioresorbable vascular scaffold (BVS) at baseline were analyzed. Precise co-registration for 72 anatomical slices was achieved utilizing unique BVS radiopaque markers. PB derived from OCT DL and IVUS were compared. OCT cross-sections were divided into four subgroups with different media visibility level. The impact of media visibility on the numerical difference between OCT-derived and IVUS-derived PB was investigated. The stent sizes selected by OCT DL and IVUS were compared. RESULTS: Sixty-four paired OCT and IVUS cross-sections were compared. OCT DL showed good concordance with IVUS for PB assessment (ICC = 0.81, difference = -3.53 ± 6.17%, p < 0.001). The numerical difference between OCT DL-derived PB and IVUS-derived PB was not substantially impacted by missing segments of media visualization (p = 0.21). OCT DL showed a diagnostic accuracy of 92% in identifying PB > 65%. The stent sizes selected by OCT DL were smaller compared to the ones selected by IVUS (difference = 0.30 ± 0.34 mm, p < 0.001). CONCLUSIONS: The DL algorithm provides a feasible and reliable method for automated PB estimation from OCT, irrespective of media visibility. OCT DL showed good diagnostic accuracy in identifying PB > 65%, revealing its potential to complement conventional OCT imaging.

3.
Catheter Cardiovasc Interv ; 99(3): 706-713, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34402586

RESUMO

BACKGROUND: Volumetric intravascular ultrasound (IVUS) analysis is currently performed at a fixed frame interval, neglecting the cyclic changes in vessel dimensions occurring during the cardiac cycle that can affect the reproducibility of the results. Analysis of end-diastolic (ED) IVUS frames has been proposed to overcome this limitation. However, at present, there is lack of data to support its superiority over conventional IVUS. OBJECTIVES: The present study aims to compare the reproducibility of IVUS volumetric analysis performed at a fixed frame interval and at the ED frames, identified retrospectively using a novel deep-learning methodology. METHODS: IVUS data acquired from 97 vessels were included in the present study; each vessel was segmented at 1 mm interval (conventional approach) and at ED frame twice by an expert analyst. Reproducibility was tested for the following metrics; normalized lumen, vessel and total atheroma volume (TAV), and percent atheroma volume (PAV). RESULTS: The mean length of the analyzed segments was 50.0 ± 24.1 mm. ED analysis was more reproducible than the conventional analysis for the normalized lumen (mean difference: 0.76 ± 4.03 mm3 vs. 1.72 ± 11.37 mm3 ; p for the variance of differences ratio < 0.001), vessel (0.30 ± 1.79 mm3 vs. -0.47 ± 10.26 mm3 ; p < 0.001), TAV (-0.46 ± 4.03 mm3 vs. -2.19 ± 14.39 mm3 ; p < 0.001) and PAV (-0.12 ± 0.59% vs. -0.34 ± 1.34%; p < 0.001). Results were similar when the analysis focused on the 10 mm most diseased segment. The superiority of the ED approach was due to a more reproducible detection of the segment of interest and to the fact that it was not susceptible to the longitudinal motion of the IVUS probe and the cyclic changes in vessel dimensions during the cardiac cycle. CONCLUSIONS: ED IVUS segmentation enables more reproducible volumetric analysis and quantification of TAV and PAV that are established end points in longitudinal studies assessing the efficacy of novel pharmacotherapies. Therefore, it should be preferred over conventional IVUS analysis as its higher reproducibility is expected to have an impact on the sample size calculation for the primary end point.


Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/tratamento farmacológico , Vasos Coronários/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Resultado do Tratamento , Ultrassonografia de Intervenção/métodos
4.
Clin Transplant ; 36(1): e14488, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34747048

RESUMO

Cardiac allograft vasculopathy (CAV) remains a leading cause of long-term mortality after heart transplantation. Both preventive measures and treatment options are limited. This study aimed to evaluate the short-term effects of high-intensity interval training (HIT) on CAV in de novo heart transplant (HTx) recipients as assessed by optical coherence tomography (OCT). The study population was a subgroup of the 81-patient HITTS study in which HTx recipients were randomized to HIT or moderate intensity continuous training (MICT) for nine consecutive months. OCT images from baseline and 12 months were compared to assess CAV progression. The primary endpoint was defined as the change in the mean intima area. Paired OCT data were available for 56 patients (n = 23 in the HIT group and n = 33 in the MICT group). The intima area in the entire study population increased by 25% [from 1.8±1.4 mm2 to 2.3±2.0 mm2 , P < .05]. The change was twofold higher in the MICT group (.6±1.2 mm2 ) than in the HIT group (.3±.6 mm2 ). However, the treatment effect of HIT was not significant (treatment effect = -.3 mm2 , 95% CI [-.825 to .2 mm2 ] P = .29). These results suggest that early initiation of HIT compared with MICT does not attenuate CAV progression in de novo HTx recipients.


Assuntos
Transplante de Coração , Treinamento Intervalado de Alta Intensidade , Aloenxertos , Transplante de Coração/efeitos adversos , Humanos , Tomografia de Coerência Óptica
5.
J Thromb Thrombolysis ; 54(4): 647-659, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36205839

RESUMO

Vascular inflammation, lipid metabolism, and thrombogenicity play a key role not only in atherogenesis but also in the development of acute coronary syndromes. Biomarkers associated with coronary high-risk plaques defined according to intravascular imaging have not been systematically studied. A total of 69 patients with coronary artery disease who underwent both optical coherence tomography and intravascular ultrasound imaging, and who provided blood specimens were included. Comprehensive biomarkers for inflammation, lipid, and coagulation were analyzed. Composite models sought biomarker patterns associated with thin-cap fibroatheroma (TCFA) and "high-risk plaques" (TCFA and large plaque burden). Two different composite models were developed for TCFA, based on the finding that high sensitivity C-reactive protein (hsCRP), plasminogen activator inhibitor-1, fibrinogen, IL-6, homocysteine and amyloid A levels were elevated, and high-density lipoprotein cholesterol (HDL) and bile acid levels were decreased in these patients. Both composite models were highly accurate for detecting patients with TCFA (area under curve [AUC]: 0.883 in model-A and 0.875 in model-B, both p < 0.001). In addition, creatinine, hsCRP, fibrinogen, tumor necrosis factor-α, IL-6, homocysteine, amyloid A, HDL, prothrombin, and bile acid were useful for detecting patients with "high-risk plaques". Two composite models were highly accurate for detection of patients with "high-risk plaques" (AUC: 0.925 in model-A and 0.947 in model-B, both p < 0.001). Biomarkers useful for detection of patients with high-risk coronary plaques defined according to intravascular imaging have been identified. These biomarkers may be useful to risk stratify patients and to develop targeted therapy.Clinical Trial Registration https://www.umin.ac.jp/ctr/ , UMIN000041692. Biomarkers and high-risk plaques hsCRP, PAI-1, fibrinogen, IL-6, homocysteine, amyloid A, HDL, and bile acid were useful for detecting patients with TCFA. hsCRP, fibrinogen, IL-6, homocysteine, amyloid A, creatinine, TNFα, HDL, prothrombin, and bile acid were useful for detecting patients with "high-risk plaques" (plaque which has both TCFA and large plaque burden). White arrowhead denotes TCFA. Red and green dashed lines denote lumen area and external elastic membrane area, respectively.


Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Placa Aterosclerótica/patologia , Vasos Coronários/patologia , Proteína C-Reativa/análise , Protrombina/metabolismo , Creatinina , Interleucina-6 , Ultrassonografia de Intervenção/métodos , Valor Preditivo dos Testes , Tomografia de Coerência Óptica/métodos , Biomarcadores , Fibrinogênio/metabolismo , Homocisteína/metabolismo , Inflamação/patologia , Ácidos e Sais Biliares/metabolismo , Angiografia Coronária
6.
Int J Med Sci ; 19(2): 205-212, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35165506

RESUMO

This study aimed to determine the ability of single fiber reflectance (SFR) spectroscopy incorporated in endoscopic ultrasound fine needle biopsy (EUS-FNB) procedures in the pancreas to distinguish benign and malignant pancreatic tissue in patient with pancreatic masses suspected for malignancy. Methods: This study was designed as a prospective observational single center study and included consecutive adult patients, who were scheduled for EUS-FNB of a solid pancreatic mass suspected for pancreatic ductal adenocarcinoma (PDAC). In total, seven optical parameters, derived from the absorption acquired spectra, were analyzed: blood volume fraction (BVF), microvascular saturation, average vessel diameter, bilirubin concentration (BIL), Mie amplitude, Mie slope and Rayleigh amplitude. Results: Forty-five patients with a suspicious pancreatic lesion undergoing EUS-FNB were included, of which most of the patients (N=34) were ultimately diagnosed with PDAC. Finally, 27 out of 45 (60.0%) patients were used for the final analysis of the optical parameters. The median (IQR) BVF differed significantly in benign compared to malignant tissue (0.86 [0.30-2.03] and 4.49 [1.28-15.47]; p=0.046). Combining BVF and BIL to a new parameter (θ) improved the discrimination between PDAC and benign pancreatic tissue (p=0.026). The area under the curve of θ was 0.84, resulting in a 92.8%, 75.0%, 97.5%, 50.0% and 91.3% sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy for detection of PDAC. Conclusion: Differentiation between PDAC and benign pancreatic tissue using SFR spectroscopy during EUS-FNB procedures is promising. Future work should focus on comparing the diagnostic performance combining SFR spectroscopy with EUS-FNB and EUS-FNB alone.


Assuntos
Detecção Precoce de Câncer/métodos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Neoplasias Pancreáticas/diagnóstico , Análise Espectral/métodos , Idoso , Área Sob a Curva , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade
7.
Circ J ; 85(10): 1806-1813, 2021 09 24.
Artigo em Inglês | MEDLINE | ID: mdl-33828020

RESUMO

BACKGROUND: Intravascular polarization-sensitive optical frequency domain imaging (PS-OFDI) offers a novel approach to measure tissue birefringence, which is elevated in collagen and smooth muscle cells, that in turn plays a critical role in healing coronary thrombus (HCT). This study aimed to quantitatively assess polarization properties of coronary fresh and organizing thrombus with PS-OFDI in patients with acute coronary syndrome (ACS).Methods and Results:The POLARIS-I prospective registry enrolled 32 patients with ACS. Pre-procedural PS-OFDI pullbacks using conventional imaging catheters revealed 26 thrombus-regions in 21 patients. Thrombus was manually delineated in conventional OFDI cross-sections separated by 0.5 mm and categorized into fresh thrombus caused by plaque rupture, stent thrombosis, or erosion in 18 thrombus-regions (182 frames) or into HCT for 8 thrombus-regions (141 frames). Birefringence of coronary thrombus was compared between the 2 categories. Birefringence in HCTs was significantly higher than in fresh thrombus (∆n=0.47 (0.37-0.72) vs. ∆n=0.25 (0.17-0.29), P=0.007). In a subgroup analysis, when only using thrombus-regions from culprit lesions, ischemic time was a significant predictor for birefringence (ß (∆n)=0.001 per hour, 95% CI [0.0002-0.002], P=0.023). CONCLUSIONS: Intravascular PS-OFDI offers the opportunity to quantitatively assess the polarimetric properties of fresh and organizing coronary thrombus, providing new insights into vascular healing and plaque stability.


Assuntos
Síndrome Coronariana Aguda , Intervenção Coronária Percutânea , Placa Aterosclerótica , Trombose , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/patologia , Angiografia Coronária , Vasos Coronários/patologia , Humanos , Intervenção Coronária Percutânea/métodos , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Trombose/diagnóstico por imagem , Trombose/patologia , Tomografia de Coerência Óptica/métodos
8.
Neuroimage ; 215: 116808, 2020 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-32289451

RESUMO

Accumulation of iron within the cortex of Alzheimer's disease (AD) patients has been reported by numerous MRI studies using iron-sensitive methods. Validation of iron-sensitive MRI is important for the interpretation of in vivo findings. In this study, the relation between the spatial iron distribution and T2∗-weighted MRI in the human brain was investigated using a direct comparison of spatial maps of iron as detected by T2∗-weighted MRI, iron histochemistry and laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS), in postmortem brain tissue of the medial frontal gyrus of three control subjects and six AD patients. In addition, iron levels measured by LA-ICP-MS and three quantitative MRI methods, namely R2∗ (=1/T2∗), image phase and quantitative susceptibility mapping (QSM), were compared between 19 AD and 11 controls. Histochemistry results we obtained with the modified Meguro staining were highly correlated with iron levels as detected by LA-ICP-MS (r2 â€‹= â€‹0.82, P â€‹< â€‹0.0001). Significant positive correlations were also found between LA-ICP-MS and the three quantitative MRI measurements: R2∗ (r2 â€‹= â€‹0.63), image phase (r2 â€‹= â€‹0.70) and QSM (r2 â€‹= â€‹0.74 (all p â€‹< â€‹0.0001)). R2∗ and QSM showed the strongest correlation with iron content; the correlation of phase with iron clearly showed increased variation, probably due to its high orientation dependence. Despite the obvious differences in iron distribution patterns within the cortex between AD patients and controls, no overall significant differences were found in iron as measured by LA-ICP-MS, nor in R2∗, phase or susceptibility. In conclusion, our results show that histochemistry as well as quantitative MRI methods such as R2∗ mapping and QSM provide reliable measures of iron distribution in the cortex. These results support the use of MRI studies focusing on iron distribution in both the healthy and the diseased brain.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/metabolismo , Lobo Frontal/diagnóstico por imagem , Lobo Frontal/metabolismo , Ferro/metabolismo , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Lobo Frontal/química , Voluntários Saudáveis , Humanos , Ferro/análise , Terapia a Laser/métodos , Masculino , Espectrometria de Massas/métodos , Pessoa de Meia-Idade
9.
Circ J ; 84(1): 91-100, 2019 12 25.
Artigo em Inglês | MEDLINE | ID: mdl-31735729

RESUMO

BACKGROUND: Attenuation-compensated (AC) technique was recently introduced to improve the plaque characterization of optical coherence tomography (OCT). Histological validation demonstrated promising results but the efficacy and reproducibility of this technique for assessing in-vivo tissue composition remains unclear.Methods and Results:OCT images portraying native (n=200) and stented (n=200) segments and 31 histological cross-sections were analyzed. AC-OCT appeared superior to conventional (C)-OCT in detecting the external elastic lamina (EEM) borders (76% vs. 65.5%); AC-OCT enabled larger EEM arc detection compared with C-OCT (174.2±58.7° vs. 137.5±57.9°; P<0.001). There was poor agreement between the 2 techniques for detection of lipid in native and lipid and calcific tissue in stented segments (κ range: 0.164-0.466) but the agreement of C-OCT and AC-OCT was high for calcific tissue in native segments (κ=0.825). Intra and interobserver agreement of the 2 analysts was moderate to excellent with C-OCT (κ range: 0.681-0.979) and AC-OCT (κ range: 0.733-0.892) for all tissue types in both native and stented segments. Ex-vivoanalysis demonstrated that C-OCT was superior to AC-OCT (κ=0.545 vs. κ=0.296) for the detection of the lipid component in native segments. CONCLUSIONS: The AC technique allows better delineation of the EEM but it remains inferior for lipid pool detection and neointima characterization. Combined AC- and C-OCT imaging may provide additional value for complete assessment of plaque and neointima characteristics.


Assuntos
Doença da Artéria Coronariana , Vasos Coronários , Placa Aterosclerótica , Tomografia de Coerência Óptica , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/metabolismo , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/metabolismo
10.
Proc Natl Acad Sci U S A ; 113(43): 12244-12249, 2016 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-27791011

RESUMO

The identification of tumor subpopulations that adversely affect patient outcomes is essential for a more targeted investigation into how tumors develop detrimental phenotypes, as well as for personalized therapy. Mass spectrometry imaging has demonstrated the ability to uncover molecular intratumor heterogeneity. The challenge has been to conduct an objective analysis of the resulting data to identify those tumor subpopulations that affect patient outcome. Here we introduce spatially mapped t-distributed stochastic neighbor embedding (t-SNE), a nonlinear visualization of the data that is able to better resolve the biomolecular intratumor heterogeneity. In an unbiased manner, t-SNE can uncover tumor subpopulations that are statistically linked to patient survival in gastric cancer and metastasis status in primary tumors of breast cancer.


Assuntos
Neoplasias da Mama/patologia , Variação Genética , Prognóstico , Neoplasias Gástricas/patologia , Idoso , Biomarcadores Tumorais/genética , Neoplasias da Mama/genética , Linhagem da Célula/genética , Feminino , Regulação Neoplásica da Expressão Gênica , Humanos , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade , Medicina de Precisão , Neoplasias Gástricas/genética , Análise de Sobrevida
11.
Eur Heart J ; 39(18): 1602-1609, 2018 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-29409057

RESUMO

Aims: As a sine qua non for arterial wall physiology, local hemodynamic forces such as endothelial shear stress (ESS) may influence long-term vessel changes as bioabsorbable scaffolds dissolve. The aim of this study was to perform serial computational fluid dynamic (CFD) simulations to examine immediate and long-term haemodynamic and vascular changes following bioresorbable scaffold placement. Methods and results: Coronary arterial models with long-term serial assessment (baseline and 5 years) were reconstructed through fusion of intravascular optical coherence tomography and angiography. Pulsatile non-Newtonian CFD simulations were performed to calculate the ESS and relative blood viscosity. Time-averaged, systolic, and diastolic results were compared between follow-ups. Seven patients (seven lesions) were included in this analysis. A marked heterogeneity in ESS and localised regions of high blood viscosity were observed post-implantation. Percent vessel area exposed to low averaged ESS (<1 Pa) significantly decreased over 5 years (15.92% vs. 4.99%, P < 0.0001) whereas moderate (1-7 Pa) and high ESS (>7 Pa) did not significantly change (moderate ESS: 76.93% vs. 80.7%, P = 0.546; high ESS: 7.15% vs. 14.31%, P = 0.281), leading to higher ESS at follow-up. A positive correlation was observed between baseline ESS and change in lumen area at 5 years (P < 0.0001). Maximum blood viscosity significantly decreased over 5 years (4.30 ± 1.54 vs. 3.21± 0.57, P = 0.028). Conclusion: Immediately after scaffold implantation, coronary arteries demonstrate an alternans of extremely low and high ESS values and localized areas of high blood viscosity. These initial local haemodynamic disturbances may trigger fibrin deposition and thrombosis. Also, low ESS can promote neointimal hyperplasia, but may also contribute to appropriate scaffold healing with normalisation of ESS and reduction in peak blood viscosity by 5 years.


Assuntos
Implantes Absorvíveis , Vasos Coronários/patologia , Vasos Coronários/fisiopatologia , Endotélio Vascular/patologia , Endotélio Vascular/fisiopatologia , Modelos Cardiovasculares , Alicerces Teciduais , Fenômenos Biomecânicos , Vasos Coronários/cirurgia , Endotélio Vascular/cirurgia , Hidrodinâmica , Imageamento Tridimensional , Estresse Mecânico , Fatores de Tempo , Tomografia de Coerência Óptica
12.
J Proteome Res ; 17(3): 1054-1064, 2018 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-29430923

RESUMO

Technological advances in mass spectrometry imaging (MSI) have contributed to growing interest in 3D MSI. However, the large size of 3D MSI data sets has made their efficient analysis and visualization and the identification of informative molecular patterns computationally challenging. Hierarchical stochastic neighbor embedding (HSNE), a nonlinear dimensionality reduction technique that aims at finding hierarchical and multiscale representations of large data sets, is a recent development that enables the analysis of millions of data points, with manageable time and memory complexities. We demonstrate that HSNE can be used to analyze large 3D MSI data sets at full mass spectral and spatial resolution. To benchmark the technique as well as demonstrate its broad applicability, we have analyzed a number of publicly available 3D MSI data sets, recorded from various biological systems and spanning different mass-spectrometry ionization techniques. We demonstrate that HSNE is able to rapidly identify regions of interest within these large high-dimensionality data sets as well as aid the identification of molecular ions that characterize these regions of interest; furthermore, through clearly separating measurement artifacts, the HSNE analysis exhibits a degree of robustness to measurement batch effects, spatially correlated noise, and mass spectral misalignment.


Assuntos
Imageamento Tridimensional/métodos , Imagem Molecular/métodos , Proteômica/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Animais , Carcinoma de Células Escamosas/química , Carcinoma de Células Escamosas/metabolismo , Carcinoma de Células Escamosas/ultraestrutura , Neoplasias Colorretais/química , Neoplasias Colorretais/metabolismo , Neoplasias Colorretais/ultraestrutura , Humanos , Imageamento Tridimensional/instrumentação , Rim/química , Rim/metabolismo , Rim/ultraestrutura , Camundongos , Imagem Molecular/instrumentação , Neoplasias Bucais/química , Neoplasias Bucais/metabolismo , Neoplasias Bucais/ultraestrutura , Redução Dimensional com Múltiplos Fatores , Pâncreas/química , Pâncreas/metabolismo , Pâncreas/ultraestrutura , Placa Aterosclerótica/química , Placa Aterosclerótica/metabolismo , Placa Aterosclerótica/ultraestrutura , Proteômica/instrumentação , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação , Processos Estocásticos
13.
J Surg Oncol ; 118(2): 283-300, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29938401

RESUMO

Near-infrared (NIR) fluorescence imaging is gaining clinical acceptance over the last years and has been used for detection of lymph nodes, several tumor types, vital structures and tissue perfusion. This review focuses on NIR fluorescence imaging with indocyanine green and methylene blue for different clinical applications in abdominal surgery with an emphasis on oncology, based on a systematic literature search. Furthermore, practical information on doses, injection times, and intraoperative use are provided.


Assuntos
Neoplasias Abdominais/diagnóstico por imagem , Neoplasias Abdominais/cirurgia , Verde de Indocianina , Azul de Metileno , Imagem Óptica/métodos , Cirurgia Assistida por Computador/métodos , Abdome/diagnóstico por imagem , Abdome/cirurgia , Corantes , Humanos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Biópsia de Linfonodo Sentinela/métodos
14.
Circ J ; 82(6): 1575-1583, 2018 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-29576586

RESUMO

BACKGROUND: Development of methods for accurate reconstruction of bioresorbable scaffolds (BRS) and assessing local hemodynamics is crucial for investigation of vascular healing after BRS implantation.Methods and Results:Patients with BRS that crossed over in a coronary bifurcation were included for analysis. Reconstructions of the coronary lumen and BRS were performed by fusion of optical coherence tomography and coronary angiography generating a tree model (TM) and a hybrid model with BRS (TM-BRS). A virtual BRS model with thinner struts was created and all 3 models were analyzed using computational fluid dynamics to derive: (1) time-average shear stress (TASS), (2) TASS gradient (TASSG), which represents SS heterogeneity, and (3) fractional flow reserve (FFR). Reconstruction of the BRS was successful in all 10 patients. TASS and TASSG were both higher by TM-BRS than by TM in main vessels (difference 0.27±4.30 Pa and 10.18±27.28 Pa/mm, P<0.001), with a remarkable difference at side branch ostia (difference 13.51±17.40 Pa and 81.65±105.19 Pa/mm, P<0.001). With thinner struts, TASS was lower on the strut surface but higher at the inter-strut zones, whereas TASSG was lower in both regions (P<0.001 for all). Computational FFR was lower by TM-BRS than by TM for both main vessels and side branches (P<0.001). CONCLUSIONS: Neglecting BRS reconstruction leads to significantly lower SS and SS heterogeneity, which is most pronounced at side branch ostia. Thinner struts can marginally reduce SS heterogeneity.


Assuntos
Implantes Absorvíveis , Hemodinâmica , Modelos Cardiovasculares , Alicerces Teciduais , Idoso , Angiografia Coronária/métodos , Vasos Coronários/cirurgia , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Pessoa de Meia-Idade , Stents , Estresse Mecânico , Tomografia de Coerência Óptica/métodos , Cicatrização
15.
Catheter Cardiovasc Interv ; 89(4): 679-689, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28109054

RESUMO

By providing valuable information about the coronary artery wall and lumen, intravascular imaging may aid in optimizing interventional procedure results and thereby could improve clinical outcomes following percutaneous coronary intervention (PCI). Intravascular optical coherence tomography (OCT) is a light-based technology with a tissue penetration of approximately 1 to 3 mm and provides near histological resolution. It has emerged as a technological breakthrough in intravascular imaging with multiple clinical and research applications. OCT provides detailed visualization of the vessel following PCI and provides accurate assessment of post-procedural stent performance including detection of edge dissection, stent struts apposition, tissue prolapse, and healing parameters. Additionally, it can provide accurate characterization of plaque morphology and provides key information to optimize post-procedural outcomes. This manuscript aims to review the current clinical and research applications of intracoronary OCT and summarize the analytic OCT imaging software packages currently available. © 2017 Wiley Periodicals, Inc.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Intervenção Coronária Percutânea/métodos , Placa Aterosclerótica/diagnóstico , Cirurgia Assistida por Computador/métodos , Tomografia de Coerência Óptica/métodos , Doença da Artéria Coronariana/cirurgia , Humanos , Placa Aterosclerótica/cirurgia , Reprodutibilidade dos Testes
16.
Clin Transplant ; 31(9)2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28627046

RESUMO

AIMS: We examined the relationship between donor-specific HLA antibody (DSA) presence and graft function, hemodynamics, cardiac allograft vasculopathy (CAV), and major adverse cardiac events (MACE) in stable long-term heart-transplanted (HTx) patients. METHODS: Sera from 79 patients (median 7.5 years after HTx) were analyzed for DSA presence. Graft function was evaluated by echocardiography and right heart catheterization. CAV burden was determined by coronary angiography, optical coherence tomography (OCT), and coronary flow velocity reserve (CFVR). Patients were prospectively followed after DSA assessment. MACE included significant CAV progression, heart failure, treated rejection, and cardiovascular death. RESULTS: Sixty patients had no DSA, and 19 patients were sensitized. The vasculopathy burden by angiography, OCT, and CFVR was more pronounced in DSA-positive patients than in DSA-negative patients. DSA-positive patients had higher pulmonary capillary wedge pressure (16 [8; 21] vs 9 mm Hg [7; 11], P<.05) and right atrial pressure (8 [6; 9] vs 4 mm Hg [2; 6], P<.01) and lower global longitudinal strain (-13% [-10; -15] vs -16% [-14; -17], P<.01) than DSA-negative patients. DSA presence was a strong MACE predictor (HR 4.7 (95% CI 2.0-11.4), P<.001). CONCLUSIONS: DSA-positive patients had higher vasculopathy burden, higher filling pressures, and lower longitudinal myocardial deformation than DSA-negative patients. The DSA presence was a strong MACE predictor.


Assuntos
Antígenos HLA/imunologia , Transplante de Coração , Isoanticorpos/sangue , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/imunologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Cardiomiopatias/diagnóstico , Cardiomiopatias/imunologia , Cardiomiopatias/mortalidade , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/imunologia , Doença da Artéria Coronariana/mortalidade , Feminino , Seguimentos , Rejeição de Enxerto/diagnóstico , Rejeição de Enxerto/imunologia , Rejeição de Enxerto/mortalidade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/imunologia , Insuficiência Cardíaca/mortalidade , Hemodinâmica/imunologia , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/mortalidade , Prognóstico , Estudos Prospectivos , Método Simples-Cego , Adulto Jovem
17.
J Nucl Cardiol ; 24(4): 1253-1262, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-26860110

RESUMO

BACKGROUND: Coronary-computed tomography angiography (CTA) has limited accuracy to predict myocardial ischemia. Besides luminal area stenosis, other coronary plaque morphology and composition parameters may help to assess ischemia. With the integration of coronary CTA and adenosine stress CT myocardial perfusion (CTP), reliable information regarding coronary anatomy and function can be derived in one procedure. This analysis aimed to investigate the association between coronary stenosis severity, plaque composition and morphology and the presence of ischemia measured with adenosine stress myocardial CTP. METHODS AND RESULTS: 84 patients (age, 62 ± 10 years; 48% men) who underwent sequential coronary CTA and adenosine stress myocardial CT perfusion were analyzed. Automated quantification was performed in all coronary lesions (quantitative CTA). Downstream myocardial ischemia was assessed by visual analysis of the rest and stress CTP images and defined as a summed difference score of ≥1. One or more coronary plaques were present in 146 coronary arteries of which 31 (21%) were ischemia-related. Of the lesions with a stenosis percentage <50%, 50%-70%, and >70%, respectively, 9% (6/67), 18% (9/51), and 57% (16/28) demonstrated downstream ischemia. Furthermore, mean plaque burden, plaque volume, lesion length, maximal plaque thickness, and dense calcium volume were significantly higher in ischemia-related lesions, but only stenosis severity (%) (OR 1.06; 95% CI 1.02-1.10; P = .006) and lesion length (mm) (OR 1.26; 95% CI 1.02-1.55; P = .029) were independent correlates. CONCLUSIONS: Increasing stenosis percentage by quantitative CTA is positively correlated to myocardial ischemia measured with adenosine stress myocardial CTP. However, stenosis percentage remains a moderate determinant. Lumen area stenosis and lesion length were independently associated with ischemia, adjusted for coronary plaque volume, mean plaque burden, maximal lesion thickness, and dense calcium volume.


Assuntos
Adenosina/farmacologia , Angiografia Coronária/métodos , Teste de Esforço , Isquemia Miocárdica/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Estenose Coronária/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
18.
Circ J ; 80(11): 2317-2326, 2016 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-27725525

RESUMO

BACKGROUND: The optimal implantation technique for the bioresorbable scaffold (Absorb, Abbott Vascular) is still a matter of debate. The purpose of the present study was to evaluate the effect of implantation technique on strut embedment and scaffold expansion.Methods and Results:Strut embedment depth and scaffold expansion index assessed by optical coherence tomography (OCT) (minimum scaffold area/reference vessel area) were evaluated in the ABSORB Japan trial (OCT subgroup: 87 lesions) with respect to implantation technique using either quantitative coronary angiography (QCA) or OCT. Strut embedment was assessed at the strut level (n=667), while scaffold expansion was assessed at the lesion level (n=81). The mean embedment depth was 63±59 µm. Balloon sizing and inflation pressure had no direct effect on strut embedment. Plaque morphology affected strut embedment [nonatherosclerotic (58.9±54.3 µm), fibroatheroma (73.3±59.6 µm), fibrous plaque (59.7±51.1 µm), and fibrocalcific plaque (-3.1±61.6 µm, negative value means malapposition), P <0.001]. The balloon-artery ratio positively correlated with the expansion index. This relationship was stronger when the OCT-derived reference vessel diameter (RVD) was used as a reference for balloon selection rather than the QCA-derived one [predilatation (Pearson correlation r: QCA: 0.167 vs. OCT: 0.552), postdilatation (QCA: 0.316 vs. OCT: 0.717)]. CONCLUSIONS: Underlying plaque morphology influenced strut embedment, whereas implantation technique had no direct effect on it. Optimal balloon sizing based on OCT-derived RVD might be recommended. However, the safety of such a strategy should be investigated in a prospective trial. (Circ J 2016; 80: 2317-2326).


Assuntos
Implantes Absorvíveis , Implante de Prótese Vascular/métodos , Prótese Vascular , Angiografia Coronária , Placa Aterosclerótica , Poliésteres , Alicerces Teciduais , Feminino , Humanos , Masculino , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/cirurgia
19.
Anal Chem ; 87(24): 11978-83, 2015 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-26595321

RESUMO

Mass spectrometry imaging (MSI) is widely used for clinical research because when combined with histopathological analysis the molecular signatures of specific cells/regions can be extracted from the often-complex histologies of pathological tissues. The ability of MSI to stratify patients according to disease, prognosis, and response is directly attributable to this cellular specificity. MSI developments are increasingly focused on further improving specificity, through higher spatial resolution to better localize the signals or higher mass resolution to better resolve molecular ions. Higher spatial/mass resolution leads to increased data size and longer data acquisition times. For clinical applications, which analyze large series of patient tissues, this poses a challenge to keep data load and acquisition time manageable. Here we report a new tool to perform histology guided MSI; instead of analyzing large parts of each tissue section the histology from adjacent tissue sections is used to focus the analysis on the areas of interest, e.g., comparable cell types in different patient tissues, thereby minimizing data acquisition time and data load. The histology tissue section is annotated and then automatically registered to the MSI-prepared tissue section; the registration transformation is then applied to the annotations, enabling them to be used to define the MSI measurement regions. Using a series of formalin-fixed, paraffin-embedded human myxoid liposarcoma tissues, we demonstrate an 80% reduction of data load and acquisition time, thereby enabling high resolution (mass or spatial) to be more readily applied to clinical research. The software is freely available for download.


Assuntos
Técnicas Histológicas/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Técnicas Histológicas/normas , Humanos , Lipossarcoma Mixoide/diagnóstico , Lipossarcoma Mixoide/patologia , Inclusão em Parafina , Reprodutibilidade dos Testes
20.
Eur Radiol ; 25(10): 3073-83, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25994190

RESUMO

OBJECTIVE: To evaluate the diagnostic performance of automated coronary atherosclerotic plaque quantification (QCT) by different users (expert/non-expert/automatic). METHODS: One hundred fifty coronary artery segments from 142 patients who underwent coronary computed tomography angiography (CCTA) and intravascular ultrasound (IVUS) were analyzed. Minimal lumen area (MLA), maximal lumen area stenosis percentage (%AS), mean plaque burden percentage (%PB), and plaque volume were measured semi-automatically by expert, non-expert, and fully automatic QCT analyses, and then compared to IVUS. RESULTS: Between IVUS and expert QCT analysis, the correlation coefficients (r) for the MLA, %AS, %PB, and plaque volume were excellent: 0.89 (p < 0.001), 0.84 (p < 0.001), 0.91 (p < 0.001), and 0.94 (p < 0.001), respectively. There were no significant differences in the mean parameters (all p values >0.05) except %AS (p = 0.01). The automatic QCT analysis showed comparable performance to non-expert QCT analysis, showing correlation coefficients (r) of the MLA (0.80 vs. 0.82), %AS (0.82 vs. 0.80), %PB (0.84 vs. 0.73), and plaque volume (0.84 vs. 0.79) when they were compared to IVUS, respectively. CONCLUSION: Fully automatic QCT analysis showed clinical utility compared with IVUS, as well as a compelling performance when compared with semiautomatic analyses. KEY POINTS: • Coronary CTA enables the assessment of coronary atherosclerotic plaque. • High-risk plaque characteristics and overall plaque burden can predict future cardiac events. • Coronary atherosclerotic plaque quantification is currently unfeasible in practice. • Quantitative computed tomography coronary plaque analysis software (QCT) enables feasible plaque quantification. • Fully automatic QCT analysis shows excellent performance.


Assuntos
Doença da Artéria Coronariana/patologia , Placa Aterosclerótica/patologia , Idoso , Algoritmos , Angiografia Coronária/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Placa Aterosclerótica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia de Intervenção/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA