Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Audiol Neurootol ; 28(6): 478-487, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37482054

RESUMO

INTRODUCTION: Cochlear implant (CI) and electric-acoustic stimulation (EAS) users may experience better performance with maps that align the electric filter frequencies to the cochlear place frequencies, known as place-based maps, than with maps that present spectrally shifted information. Individual place-based mapping procedures differ in the frequency content that is aligned to cochlear tonotopicity versus discarded or spectrally shifted. The performance benefit with different place-based maps may vary due to individual differences in angular insertion depth (AID) of the electrode array and whether functional acoustic low-frequency information is available in the implanted ear. The present study compared masked speech recognition with two types of place-based maps as a function of AID and presence of acoustic low-frequency information. METHODS: Sixty adults with normal hearing listened acutely to CI or EAS simulations of two types of place-based maps for one of three cases of electrode arrays at shallow AIDs. The strict place-based (Strict-PB) map aligned the low- and mid-frequency information to cochlear tonotopicity and discarded information below the frequency associated with the most apical electrode contact. The alternative place-based map (LFshift-PB) aligned the mid-frequency information to cochlear tonotopicity and provided more of the speech spectrum by compressing low-frequency information on the apical electrode contacts (i.e., <1 kHz). Three actual cases of a 12-channel, 24-mm electrode array were simulated by assigning the carrier frequency for an individual channel as the cochlear place frequency of the associated electrode contact. The AID and cochlear place frequency for the most apical electrode contact were 460° and 498 Hz for case 1, 389° and 728 Hz for case 2, and 335° and 987 Hz for case 3, respectively. RESULTS: Generally, better performance was observed with the Strict-PB maps for cases 1 and 2, where mismatches were 2-4 octaves for the most apical channel with the LFshift-PB map. Similar performance was observed between maps for case 3. For the CI simulations, performance with the Strict-PB map declined with decreases in AID, while performance with the LFshift-PB map remained stable across cases. For the EAS simulations, performance with the Strict-PB map remained stable across cases, while performance with the LFshift-PB map improved with decreases in AID. CONCLUSIONS: Listeners demonstrated differences with the Strict-PB versus LFshift-PB maps as a function of AID and whether acoustic low-frequency information was available (CI vs. EAS). These data support the use of the Strict-PB mapping procedure for AIDs ≥335°, though further study including time for acclimatization in CI and EAS users is warranted.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Humanos , Implante Coclear/métodos , Cóclea , Estimulação Acústica , Percepção da Fala/fisiologia , Acústica , Estimulação Elétrica
2.
Ear Hear ; 44(5): 955-968, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36879386

RESUMO

OBJECTIVES: Children with severe-to-profound unilateral hearing loss, including cases of single-sided deafness (SSD), lack access to binaural cues that support spatial hearing, such as recognizing speech in complex multisource environments and sound source localization. Listening in a monaural condition negatively impacts communication, learning, and quality of life for children with SSD. Cochlear implant (CI) use may restore binaural hearing abilities and improve outcomes as compared to alternative treatments or no treatment. This study investigated performance over 24 months of CI use in young children with SSD as compared to the better hearing ear alone and to children with bilateral normal hearing (NH). DESIGN: Eighteen children with SSD who received a CI between the ages of 3.5 and 6.5 years as part of a prospective clinical trial completed assessments of word recognition in quiet, masked sentence recognition, and sound source localization at regular intervals out to 24-month postactivation. Eighteen peers with bilateral NH, matched by age at the group level, completed the same test battery. Performance at 24-month postactivation for the SSD group was compared to the performance of the NH group. RESULTS: Children with SSD have significantly poorer speech recognition in quiet, masked sentence recognition, and localization both with and without the use of the CI than their peers with NH. The SSD group experienced significant benefits with the CI+NH versus the NH ear alone on measures of isolated word recognition, masked sentence recognition, and localization. These benefits were realized within the first 3 months of use and were maintained through the 24-month postactivation interval. CONCLUSIONS: Young children with SSD who use a CI experience significant isolated word recognition and bilateral spatial hearing benefits, although their performance remains poorer than their peers with NH.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Unilateral , Localização de Som , Percepção da Fala , Humanos , Criança , Pré-Escolar , Lactente , Perda Auditiva Unilateral/reabilitação , Qualidade de Vida , Estudos Prospectivos , Audição
3.
Audiol Neurootol ; 27(6): 437-448, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35439753

RESUMO

INTRODUCTION: Cochlear implant (CI) recipients with normal hearing (NH) in the contralateral ear experience a significant improvement in sound source localization when listening with the CI in combination with their NH-ear (CI + NH) as compared to with the NH-ear alone. The improvement in localization is primarily due to sensitivity to interaural level differences (ILDs). Sensitivity to interaural timing differences (ITDs) may be limited by auditory aging, frequency-to-place mismatches, the signal coding strategy, and duration of CI use. The present report assessed the sensitivity of ILD and ITD cues in CI + NH listeners who were recipients of long electrode arrays that provide minimal frequency-to-place mismatches and were mapped with a coding strategy that presents fine structure cues on apical channels. METHODS: Sensitivity to ILDs and ITDs for localization was assessed using broadband noise (BBN), as well as high-pass (HP) and low-pass (LP) filtered noise for adult CI + NH listeners. Stimuli were 200-ms noise bursts presented from 11 speakers spaced evenly over an 180° arc. Performance was quantified in root-mean-squared error and response patterns were analyzed to evaluate the consistency, accuracy, and side bias of the responses. Fifteen listeners completed the task at the 2-year post-activation visit; seven listeners repeated the task at a later annual visit. RESULTS: Performance at the 2-year visit was best with the BBN and HP stimuli and poorer with the LP stimulus. Responses to the BBN and HP stimuli were significantly correlated, consistent with the idea that CI + NH listeners primarily use ILD cues for localization. For the LP stimulus, some listeners responded consistently and accurately and with limited side bias, which may indicate sensitivity to ITD cues. Two of the 7 listeners who repeated the task at a later annual visit experienced a significant improvement in performance with the LP stimulus, which may indicate that sensitivity to ITD cues may improve with long-term CI use. CONCLUSIONS: CI recipients with a NH-ear primarily use ILD cues for sound source localization, though some may use ITD cues as well. Sensitivity to ITD cues may improve with long-term CI listening experience.


Assuntos
Implante Coclear , Implantes Cocleares , Localização de Som , Estimulação Acústica , Localização de Som/fisiologia , Audição
4.
Audiol Neurootol ; 27(3): 227-234, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34808626

RESUMO

INTRODUCTION: The objective of this study was to assess the influence of postponing the first post-activation follow-up due to the COVID-19 pandemic on the aided sound field detection thresholds and speech recognition of cochlear implant (CI) users. METHODS: A retrospective review was performed at a tertiary referral center. Two groups of adult CI recipients were evaluated: (1) patients whose first post-activation follow-up was postponed due to COVID-19 closures (postponed group; n = 10) and (2) a control group that attended recommended post-activation follow-ups prior to the COVID-19 pandemic (control group; n = 18). For both groups, electric thresholds were estimated at initial activation based on comfort levels and were measured behaviorally at subsequent post-activation follow-ups. For the control group, behavioral thresholds were measured at the 1-month follow-up. For the postponed group, behavioral thresholds were not measured until 3 months post-activation since the 1-month follow-up was postponed. The aided pure-tone average (PTA) and word recognition results were compared between groups at the 3-month follow-up and at an interim visit 2-9 weeks later. RESULTS: At the 3-month follow-up, the postponed group had significantly poorer word recognition (23 vs. 42%, p = 0.027) and aided PTA (42 vs. 37 dB HL, p = 0.041) than the control group. No significant differences were observed between 3-month data from the control group and interim data from the postponed group. CONCLUSIONS: The postponed follow-up after CI activation was associated with poorer outcomes, both in terms of speech recognition and aided audibility. However, these detrimental effects were reversed following provision of an individualized map, with behaviorally measured electric threshold and comfort levels. While adult CI recipients demonstrate an improvement in speech recognition with estimated electric thresholds, the present results suggest that behavioral mapping within the initial weeks of device use may support optimal outcomes.


Assuntos
COVID-19 , Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Limiar Auditivo , Implante Coclear/métodos , Seguimentos , Humanos , Pandemias , Percepção da Fala/fisiologia
5.
Ear Hear ; 43(6): 1605-1619, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35994570

RESUMO

The indications for cochlear implantation have expanded to include individuals with profound sensorineural hearing loss in the impaired ear and normal hearing (NH) in the contralateral ear, known as single-sided deafness (SSD). There are additional considerations for the clinical assessment and management of adult cochlear implant candidates and recipients with SSD as compared to conventional cochlear implant candidates with bilateral moderate to profound sensorineural hearing loss. The present report reviews the current evidence relevant to the assessment and management of adults with SSD. A systematic review was also conducted on published studies that investigated outcomes of cochlear implant use on measures of speech recognition in quiet and noise, sound source localization, tinnitus perception, and quality of life for this patient population. Expert consensus and systematic review of the current literature were combined to provide guidance for the clinical assessment and management of adults with SSD.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Perda Auditiva Neurossensorial , Perda Auditiva Unilateral , Localização de Som , Percepção da Fala , Adulto , Humanos , Qualidade de Vida , Perda Auditiva Neurossensorial/cirurgia , Surdez/reabilitação , Perda Auditiva Unilateral/reabilitação , Resultado do Tratamento
6.
Ear Hear ; 42(4): 941-948, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33369942

RESUMO

OBJECTIVES: Electrocochleography (ECochG), obtained before the insertion of a cochlear implant (CI) array, provides a measure of residual cochlear function that accounts for a substantial portion of variability in postoperative speech perception outcomes in adults. It is postulated that subsequent surgical factors represent independent sources of variance in outcomes. Prior work has demonstrated a positive correlation between angular insertion depth (AID) of straight arrays and speech perception under the CI-alone condition, with an inverse relationship observed for precurved arrays. The purpose of the present study was to determine the combined effects of ECochG, AID, and array design on speech perception outcomes. DESIGN: Participants were 50 postlingually deafened adult CI recipients who received one of three straight arrays (MED-EL Flex24, MED-EL Flex28, and MED-EL Standard) and two precurved arrays (Cochlear Contour Advance and Advanced Bionics HiFocus Mid-Scala). Residual cochlear function was determined by the intraoperative ECochG total response (TR) measured before array insertion, which is the sum of magnitudes of spectral components in response to tones of different stimulus frequencies across the speech spectrum. The AID was then determined with postoperative imaging. Multiple linear regression was used to predict consonant-nucleus-consonant (CNC) word recognition in the CI-alone condition at 6 months postactivation based on AID, TR, and array design. RESULTS: Forty-one participants received a straight array and nine received a precurved array. The AID of the most apical electrode contact ranged from 341° to 696°. The TR measured by ECochG accounted for 43% of variance in speech perception outcomes (p < 0.001). A regression model predicting CNC word scores with the TR tended to underestimate the performance for precurved arrays and deeply inserted straight arrays, and to overestimate the performance for straight arrays with shallower insertions. When combined in a multivariate linear regression, the TR, AID, and array design accounted for 72% of variability in speech perception outcomes (p < 0.001). CONCLUSIONS: A model of speech perception outcomes that incorporates TR, AID, and array design represents an improvement over a model based on TR alone. The success of this model shows that peripheral factors including cochlear health and electrode placement may play a predominant role in speech perception with CIs.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Audiometria de Resposta Evocada , Cóclea/cirurgia , Humanos
7.
Ear Hear ; 41(5): 1349-1361, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32205726

RESUMO

OBJECTIVES: The spatial position of a cochlear implant (CI) electrode array affects the spectral cues provided to the recipient. Differences in cochlear size and array length lead to substantial variability in angular insertion depth (AID) across and within array types. For CI-alone users, the variability in AID results in varying degrees of frequency-to-place mismatch between the default electric frequency filters and cochlear place of stimulation. For electric-acoustic stimulation (EAS) users, default electric frequency filters also vary as a function of residual acoustic hearing in the implanted ear. The present study aimed to (1) investigate variability in AID associated with lateral wall arrays, (2) determine the subsequent frequency-to-place mismatch for CI-alone and EAS users mapped with default frequency filters, and (3) examine the relationship between early speech perception for CI-alone users and two aspects of electrode position: frequency-to-place mismatch and angular separation between neighboring contacts, a metric associated with spectral selectivity at the periphery. DESIGN: One hundred one adult CI recipients (111 ears) with MED-EL Flex24 (24 mm), Flex28 (28 mm), and FlexSOFT/Standard (31.5 mm) arrays underwent postoperative computed tomography to determine AID. A subsequent comparison was made between AID, predicted spiral ganglion place frequencies, and the default frequency filters for CI-alone (n = 84) and EAS users (n = 27). For CI-alone users with complete insertions who listened with maps fit with the default frequency filters (n = 48), frequency-to-place mismatch was quantified at 1500 Hz and angular separation between neighboring contacts was determined for electrodes in the 1 to 2 kHz region. Multiple linear regression was used to examine how frequency-to-place mismatch and angular separation of contacts influence consonant-nucleus-consonant (CNC) scores through 6 months postactivation. RESULTS: For CI recipients with complete insertions (n = 106, 95.5%), the AID (mean ± standard deviation) of the most apical contact was 428° ± 34.3° for Flex24 (n = 11), 558° ± 65.4° for Flex28 (n = 48), and 636° ± 42.9° for FlexSOFT/Standard (n = 47) arrays. For CI-alone users, default frequency filters aligned closely with the spiral ganglion map for deeply inserted lateral wall arrays. For EAS users, default frequency filters produced a range of mismatches; absolute deviations of ≤ 6 semitones occurred in only 37% of cases. Participants with shallow insertions and minimal or no residual hearing experienced the greatest mismatch. For CI-alone users, both smaller frequency-to-place mismatch and greater angular separation between contacts were associated with better CNC scores during the initial 6 months of device use. CONCLUSIONS: There is significant variability in frequency-to-place mismatch among CI-alone and EAS users with default frequency filters, even between individuals implanted with the same array. When using default frequency filters, mismatch can be minimized with longer lateral wall arrays and insertion depths that meet the edge frequency associated with residual hearing for CI-alone and EAS users, respectively. Smaller degrees of frequency-to-place mismatch and decreased peripheral masking due to more widely spaced contacts may independently support better speech perception with longer lateral wall arrays in CI-alone users.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Estimulação Acústica , Audição , Humanos
8.
Am J Otolaryngol ; 41(4): 102518, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32451290

RESUMO

OBJECTIVE: Cochlear nerve preserving translabyrinthine vestibular schwannoma (VS) resection enables concurrent cochlear implantation. Implantation in patients with VS raises important concerns including the ability to undergo postoperative magnetic resonance imaging (MRI) monitoring of residual tumor growth or tumor recurrence, specifically with a retained magnet. We aim to assess the feasibility of MRI monitoring and the impact on image quality with retained cochlear implant (CI) magnets. METHODS: Retrospective review of post-operative head MRI scans in CI recipients with a retained CI magnet, after cochlear nerve preserving translabyrinthine excision of VS. The ability to visualize the ipsilateral and contralateral internal auditory canal (IAC) and cerebellopontine angle (CPA) were assessed. RESULTS: A total of eight surveillance head MRI were performed in six patients. In one case, in which the receiver was positioned lower, the view of the ipsilateral IAC and CPA was distorted. In all other cases, the views of both the ipsilateral and contralateral IAC and CPA were overall unimpaired. DISCUSSION: Imaging artifact only very rarely impedes adequate visualization of the ipsilateral IAC or CPA in CI recipients. In anticipation of the need for further IAC and CPA imaging, it would be advisable to place the receiver in an exaggerated superior-posterior position to further decrease obscuring artifact. Thus, serial monitoring of VS tumors can be performed safely with preservation of image quality with a retained receiver magnet. CONCLUSIONS: When placing the CI receiver-stimulator farther posterior-superiorly, excellent visualization of the IAC and CPA can be accomplished without significantly impairing the image quality.


Assuntos
Implante Coclear/métodos , Nervo Coclear , Neoplasias dos Nervos Cranianos/diagnóstico por imagem , Neoplasias dos Nervos Cranianos/cirurgia , Imageamento por Ressonância Magnética/métodos , Neuroma Acústico/diagnóstico por imagem , Neuroma Acústico/cirurgia , Tratamentos com Preservação do Órgão/métodos , Doenças do Nervo Vestibulococlear/diagnóstico por imagem , Doenças do Nervo Vestibulococlear/cirurgia , Nervo Vestibulococlear/diagnóstico por imagem , Nervo Vestibulococlear/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Período Pós-Operatório , Estudos Retrospectivos
9.
Audiol Neurootol ; 22(4-5): 259-271, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29298446

RESUMO

OBJECTIVE: Patients with moderate-to-profound sensorineural hearing loss in 1 ear and normal hearing in the contralateral ear, known as unilateral hearing loss (UHL) or single-sided deafness (SSD), may experience improved quality of life with the use of a cochlear implant (CI) in the affected ear. Quality of life assessment before and after implantation may reveal changes to aspects of hearing beyond those explicitly evaluated with behavioral measures. METHODS: The present report completed 2 experiments investigating quality of life outcomes in CI recipients with UHL. The first experiment assessed quality of life during the 1st year of device use with 3 questionnaires: the Speech, Spatial, and Qualities of Hearing Scale (SSQ), the Abbreviated Profile of Hearing Aid Benefit (APHAB), and the Tinnitus Handicap Inventory. Twenty subjects were evaluated preoperatively and 1, 3, 6, 9, and 12 months post-activation. Quality of life results were compared over the study period using traditional scoring methods and the SSQ pragmatic subscales. Subscales specific to localization and speech perception in noise were compared to behavioral measures at the preoperative and 12-month intervals. The 2nd experiment evaluated quality of life preoperatively and at the 12-month interval for CI recipients with UHL and CI recipients with bilateral hearing loss, including conventional CI users and those listening with electric-acoustic stimulation (EAS). The 3 cohorts differed in CI candidacy criteria, including the amount of residual hearing in the contralateral ear. RESULTS: For subjects with moderate-to-profound UHL, receipt of a CI significantly improved quality of life, with benefits noted as early as 1 month after initial activation. The UHL cohort reported less perceived difficulty at the pre- and postoperative intervals than the conventional CI and EAS cohorts, which may be due to the presence of the normal-hearing ear. Each group experienced a significant benefit in quality of life on the APHAB with CI use. CONCLUSIONS: Cochlear implantation in cases of substantial UHL may offer significant improvements in quality of life. Quality of life measures revealed a reduction in perceived tinnitus severity and subjective improvements in speech perception in noise, spatial hearing, and listening effort. While self-report of difficulties were lower for the UHL cohort than the conventional CI and EAS cohorts, subjects in all 3 groups reported an improvement in quality of life with CI use.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Unilateral/cirurgia , Qualidade de Vida , Adulto , Idoso , Feminino , Audição , Testes Auditivos , Humanos , Masculino , Pessoa de Meia-Idade , Percepção da Fala , Inquéritos e Questionários , Resultado do Tratamento
10.
Ear Hear ; 38(5): 611-619, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28375876

RESUMO

OBJECTIVES: The present study evaluated early auditory localization abilities of cochlear implant (CI) recipients with normal or near-normal hearing (NH) in the contralateral ear. The goal of the study was to better understand the effect of CI listening experience on localization in this population. DESIGN: Twenty participants with unilateral hearing loss enrolled in a prospective clinical trial assessing outcomes of cochlear implantation (ClinicalTrials.gov Identifier: NCT02203305). All participants received the MED-EL Standard electrode array, were fit with an ear-level audio processor, and listened with the FS4 coding strategy. Localization was assessed in the sound field using an 11-speaker array with speakers uniformly positioned on a horizontal, semicircular frame. Stimuli were 200-msec speech-shaped noise bursts. The intensity level (52, 62, and 72 dB SPL) and sound source were randomly interleaved across trials. Participants were tested preoperatively, and 1, 3, and 6 months after activation of the audio processor. Performance was evaluated in two conditions at each interval: (1) unaided (NH ear alone [NH-alone] condition), and (2) aided, with either a bone conduction hearing aid (preoperative interval; bone conduction hearing aid + NH condition) or a CI (postoperative intervals; CI + NH condition). Performance was evaluated by comparing root-mean-squared (RMS) error between listening conditions and between measurement intervals. RESULTS: Mean RMS error for the soft, medium, and loud levels were 66°, 64°, and 69° in the NH-alone condition and 72°, 66°, and 70° in the bone conduction hearing aid + NH condition. Participants experienced a significant improvement in localization in the CI + NH condition at the 1-month interval (38°, 35°, and 38°) as compared with the preoperative NH-alone condition. Localization in the CI + NH condition continued to improve through the 6-month interval. Mean RMS errors were 28°, 25°, and 28° in the CI + NH condition at the 6-month interval. CONCLUSIONS: Adult CI recipients with normal or near-normal hearing in the contralateral ear experienced significant improvement in localization after 1 month of device use, and continued to improve through the 6-month interval. The present results show that binaural acclimatization in CI users with unilateral hearing loss can progress rapidly, with marked improvements in performance observed after only 1 month of listening experience.


Assuntos
Implantes Cocleares , Perda Auditiva Unilateral , Localização de Som , Adulto , Idoso , Implante Coclear , Auxiliares de Audição , Perda Auditiva Unilateral/reabilitação , Humanos , Pessoa de Meia-Idade
11.
Laryngoscope ; 134(2): 919-925, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37466238

RESUMO

OBJECTIVE: To assess the perceived benefit of cochlear implant (CI) use for children with unilateral hearing loss (UHL) and evaluate whether perceived abilities are associated with performance on measures of speech recognition and spatial hearing. METHOD: Nineteen children with moderate-to-profound UHL underwent cochlear implantation. The Speech Spatial and Qualities of Hearing Questionnaire modified for children (SSQ-C) were completed by parental proxy pre-operatively and at 3, 6, 9, 12, 18, and 24 months post-activation. Linear mixed models evaluated perceived benefits over the study period. Pearson correlations assessed the association between subjective report and performance on measures of word recognition with the CI alone and spatial hearing (speech recognition in spatially-separated noise and sound source localization) in the combined condition (CI plus contralateral ear). RESULTS: For the SSQ-C, parents reported significant improvements with CI use as compared to pre-operative perceptions (p < 0.001); improved perceptions were either maintained or continued to improve over the 2-year post-activation period. Perceived benefit did not significantly correlate with word recognition with the CI alone or spatial hearing outcomes in the combined condition. CONCLUSION: Families of children with UHL observed benefits of CI use early after cochlear implantation that was maintained with long-term device use. Responses to subjective measures may broaden our understanding of the experiences of pediatric CI users with UHL in addition to outcomes on typical measures of CI performance. LEVEL OF EVIDENCE: 3 Laryngoscope, 134:919-925, 2024.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Unilateral , Localização de Som , Percepção da Fala , Humanos , Criança , Perda Auditiva Unilateral/cirurgia , Perda Auditiva Unilateral/reabilitação , Percepção da Fala/fisiologia , Audição , Localização de Som/fisiologia , Resultado do Tratamento
12.
J Speech Lang Hear Res ; 67(6): 1932-1944, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38748909

RESUMO

PURPOSE: The purpose of this study was to evaluate the ability to discriminate yes/no questions from statements in three groups of children: bilateral cochlear implant (CI) users, nontraditional CI users with aidable hearing preoperatively in the ear to be implanted, and controls with normal hearing. Half of the nontraditional CI users had sufficient postoperative acoustic hearing in the implanted ear to use electric-acoustic stimulation, and half used a CI alone. METHOD: Participants heard recorded sentences that were produced either as yes/no questions or as statements by three male and three female talkers. Three raters scored each participant response as either a question or a statement. Bilateral CI users (n = 40, 4-12 years old) and normal-hearing controls (n = 10, 4-12 years old) were tested binaurally in the free field. Nontraditional CI recipients (n = 22, 6-17 years old) were tested with direct audio input to the study ear. RESULTS: For the bilateral CI users, performance was predicted by age but not by 125-Hz acoustic thresholds; just under half (n = 17) of the participants in this group had measurable 125-Hz thresholds in their better ear. For nontraditional CI recipients, better performance was predicted by lower 125-Hz acoustic thresholds in the test ear, and there was no association with participant age. Performance approached that of the normal-hearing controls for some participants in each group. CONCLUSIONS: Results suggest that a 125-Hz acoustic hearing supports discrimination of yes/no questions and statements in pediatric CI users. Bilateral CI users with little or no acoustic hearing at 125 Hz develop the ability to perform this task, but that ability emerges later than for children with better acoustic hearing. These results underscore the importance of preserving acoustic hearing for pediatric CI users when possible.


Assuntos
Implantes Cocleares , Percepção da Fala , Humanos , Criança , Masculino , Feminino , Pré-Escolar , Adolescente , Fatores Etários , Limiar Auditivo , Implante Coclear , Estimulação Acústica/métodos , Audição
13.
Laryngoscope ; 134(4): 1868-1873, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37767794

RESUMO

OBJECTIVE: Determine variables that influence post-activation performance for cochlear implant (CI) recipients who lost low-frequency acoustic hearing. METHODS: A retrospective review evaluated CNC word recognition for adults with normal to moderately severe low-frequency hearing (preoperative unaided thresholds of ≤70 dB HL at 250 Hz) who were implanted between 2012 and 2021 at a tertiary academic center, lost functional acoustic hearing, and were fit with a CI-alone device. Performance scores were queried from the 1, 3, 6, 12, and 24-month post-activation visits. A linear mixed model evaluated the effects of age at implantation, array length (long vs. mid/short), and preoperative low-frequency hearing (normal to mild, moderate, and moderately severe) on speech recognition with a CI alone. RESULTS: 113 patients met the inclusion criteria. There was a significant main effect of interval (p < 0.001), indicating improved word recognition post-activation despite loss of residual hearing. There were significant main effects of age (p = 0.029) and array length (p = 0.038), with no effect of preoperative low-frequency hearing (p = 0.171). There was a significant 2-way interaction between age and array length (p = 0.018), indicating that older adults with mid/short arrays performed more poorly than younger adults with long lateral wall arrays when functional acoustic hearing was lost. CONCLUSION: CI recipients with preoperative functional low-frequency hearing experience a significant improvement in speech recognition with a CI alone as compared to preoperative performance-despite the loss of low-frequency hearing. Age and electrode array length may play a role in post-activation performance. These data have implications for the preoperative counseling and device selection for hearing preservation candidates. LEVEL OF EVIDENCE: 4 Laryngoscope, 134:1868-1873, 2024.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Humanos , Idoso , Percepção da Fala/fisiologia , Audição , Testes Auditivos , Resultado do Tratamento
14.
Laryngoscope ; 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656740

RESUMO

OBJECTIVES: Research samples that are representative of patient populations are needed to ensure the generalizability of study findings. The primary aim was to assess the efficacy of a study design and recruitment strategy in obtaining a participant sample that was representative of the broader cochlear implant (CI) patient population at the CI center. A secondary aim was to review whether the CI recipient population was representative of the state population. METHODS: Demographic variables were compared for a research participant sample (n = 79) and the CI patient population (n = 338). The participant sample was recruited from the CI patient population. The study design included visits that were at the same location and frequency as the recommended clinical follow-up intervals. The demographics for the combined group (participant sample and patient population) were then compared to the reported demographics for the population in North Carolina. RESULTS: There were no significant differences between the participant sample and patient population for biological sex, age at implantation, racial distribution, socioeconomic position, degree of urbanization, or drive time to the CI center (p ≥ 0.086). The combined CI recipient population was significantly different from the North Carolina population for the distributions of race, ethnicity, and degree of urbanization (p < 0.001). CONCLUSION: The study design and recruitment strategy allowed for recruitment of a participant sample that was representative of the CI patient population. Disparities in access to cochlear implantation persist, as supported by the significant differences in the combined CI recipient population and the population for our state. LEVEL OF EVIDENCE: 3 Laryngoscope, 2024.

15.
Otol Neurotol ; 45(6): e460-e467, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38865720

RESUMO

OBJECTIVE: Misplacement of electrode arrays in the internal auditory canal (IAC) presents a unique clinical challenge. Speech recognition is limited for cochlear implant (CI) users with misplaced arrays, and there are risks with revision surgery including facial and/or cochlear nerve injury. DATABASES REVIEWED: PubMed, Embase, and Scopus. METHODS: A literature search was performed from inception to September 2023. The search terms were designed to capture articles on misplaced arrays and the management options. Articles written in English that described cases of array misplacement into the IAC for children and adults were included. The level of evidence was assessed using Oxford Center for Evidence Based Medicine guidelines. Descriptive statistical analyses were performed. RESULTS: Twenty-eight cases of arrays misplaced in the IAC were identified. Thirteen (46%) were patients with incomplete partition type 3 (IP3), and 7 (25%) were patients with common cavity (CC) malformations. Most misplaced arrays were identified postoperatively (19 cases; 68%). Of these cases, 11 (58%) were managed with array removal. No facial nerve injuries were reported with revision surgery. Eight cases (42%) were left in place. Several underwent mapping procedures in an attempt improve the sound quality with the CI. CONCLUSION: Electrode array misplacement in the IAC is a rare complication that reportedly occurs predominately in cases with IP3 and CC malformations. Removal of misplaced arrays from the IAC reportedly has not been associated with facial nerve injuries. Cases identified with IAC misplacement postoperatively can potentially be managed with modified mapping techniques before proceeding with revision surgery.


Assuntos
Implante Coclear , Implantes Cocleares , Orelha Interna , Humanos , Implantes Cocleares/efeitos adversos , Implante Coclear/efeitos adversos , Implante Coclear/métodos , Orelha Interna/cirurgia , Eletrodos Implantados/efeitos adversos , Reoperação/estatística & dados numéricos
16.
Front Hum Neurosci ; 17: 1141065, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37250696

RESUMO

Introduction: Candidacy criteria for cochlear implantation in the United States has expanded to include children with single-sided deafness (SSD) who are at least 5 years of age. Pediatric cochlear implant (CI) users with SSD experience improved speech recognition with increased daily device use. There are few studies that report the hearing hour percentage (HHP) or the incidence of non-use for pediatric CI recipients with SSD. The aim of this study was to investigate factors that impact outcomes in children with SSD who use CIs. A secondary aim was to identify factors that impact daily device use in this population. Methods: A clinical database query revealed 97 pediatric CI recipients with SSD who underwent implantation between 2014 and 2022 and had records of datalogs. The clinical test battery included speech recognition assessment for CNC words with the CI-alone and BKB-SIN with the CI plus the normal-hearing ear (combined condition). The target and masker for the BKB-SIN were presented in collocated and spatially separated conditions to evaluate spatial release from masking (SRM). Linear mixed-effects models evaluated the influence of time since activation, duration of deafness, HHP, and age at activation on performance (CNC and SRM). A separate linear mixed-effects model evaluated the main effects of age at testing, time since activation, duration of deafness, and onset of deafness (stable, progressive, or sudden) on HHP. Results: Longer time since activation, shorter duration of deafness, and higher HHP were significantly correlated with better CNC word scores. Younger age at device activation was not found to be a significant predictor of CNC outcomes. There was a significant relationship between HHP and SRM, with children who had higher HHP experiencing greater SRM. There was a significant negative correlation between time since activation and age at test with HHP. Children with sudden hearing loss had a higher HHP than children with progressive and congenital hearing losses. Conclusion: The present data presented here do not support a cut-off age or duration of deafness for pediatric cochlear implantation in cases of SSD. Instead, they expand on our understanding of the benefits of CI use in this population by reviewing the factors that influence outcomes in this growing patient population. Higher HHP, or greater percentage of time spent each day using bilateral input, was associated with better outcomes in the CI-alone and in the combined condition. Younger children and those within the first months of use had higher HHP. Clinicians should discuss these factors and how they may influence CI outcomes with potential candidates with SSD and their families. Ongoing work is investigating the long-term outcomes in this patient population, including whether increasing HHP after a period of limited CI use results in improved outcomes.

17.
Otol Neurotol ; 44(4): 297-309, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36791341

RESUMO

OBJECTIVE: To assess spatial hearing, tinnitus, and quality-of-life outcomes in adults with single-sided deafness (SSD) who underwent cochlear implantation. DATABASES REVIEWED: PubMed, MEDLINE, Embase, Cochrane Central Register of Controlled Trials, Web of Science, and Scopus databases were searched from January 2008 to September 2021 following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. METHODS: Studies reporting spatial hearing, tinnitus, and quality-of-life outcomes in adult cochlear implant (CI) recipients (≥18 yr old) with SSD were evaluated. Study characteristics, demographic data, spatial hearing (speech recognition in noise, sound source localization), tinnitus (severity, loudness), and quality-of-life outcomes were collected. RESULTS: From an initial search of 1,147 articles, 36 studies that evaluated CI use in 796 unique adults with SSD (51.3 ± 12.4 yr of age at time of implantation) were included. The mean duration of deafness was 6.2 ± 9.6 years. There was evidence of improvement for speech recognition in noise using different target-to-masker spatial configurations, with the largest benefit observed for target-to-masker configurations assessing head shadow (mean, 1.87-6.2 dB signal-to-noise ratio). Sound source localization, quantified as root-mean-squared error, improved with CI use (mean difference [MD], -25.3 degrees; 95% confidence interval [95% CI], -35.9 to -14.6 degrees; p < 0.001). Also, CI users reported a significant reduction in tinnitus severity as measured with the Tinnitus Handicap Inventory (MD, -29.97; 95% CI, -43.9 to -16.1; p < 0.001) and an improvement in spatial hearing abilities as measured with the Spatial, Speech, and Qualities of Hearing questionnaire (MD, 2.3; 95% CI, 1.7 to 2.8; p < 0.001). CONCLUSIONS: Cochlear implantation and CI use consistently offer improvements in speech recognition in noise, sound source localization, tinnitus, and perceived quality of life in adults with SSD.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Unilateral , Perda Auditiva Unilateral/psicologia , Perda Auditiva Unilateral/cirurgia , Humanos , Adulto , Qualidade de Vida , Localização de Som , Percepção da Fala , Zumbido
18.
Laryngoscope Investig Otolaryngol ; 8(1): 296-302, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36846426

RESUMO

Objectives: Access to cochlear implantation may be negatively influenced by extended travel time to a cochlear implant (CI) center or lower socioeconomic status (SES) for the individual. There is a critical need to understand the influence of these variables on patient appointment attendance for candidacy evaluations, and CI recipients' adherence to post-activation follow-up recommendations that support optimal outcomes. Methods: A retrospective chart review of adult patients referred to a CI center in North Carolina for initial cochlear implantation candidacy evaluation between April 2017 and July 2019 was conducted. Demographic and audiologic data were collected for each patient. Travel time was determined using geocoding. SES was proxied using ZCTA-level Social Deprivation Index (SDI) information. Independent samples t tests compared variables between those who did and did not attend the candidacy evaluation. Pearson correlations assessed the association of these variables and the duration of time between initial CI activation and return for first follow-up visit. Results: Three hundred and ninety patients met the inclusion criteria. There was a statistically significant difference between SDI of those who attended their candidacy evaluation versus those who did not. Age at referral or travel time did not show statistical significance between these two groups. There was no significant correlation with age at referral, travel time, or SDI with the duration of time (days) between initial activation and the 1-month follow-up. Conclusions: Our findings suggest that SES may influence a patient's ability to attend a cochlear implantation candidacy evaluation appointment and may further impact the decision to pursue cochlear implantation.Level of evidence: 4 - Case Series.

19.
Laryngoscope ; 133(10): 2792-2797, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36757052

RESUMO

OBJECTIVES: Assess the long-term patterns of perceived tinnitus severity and subjective benefit for adult cochlear implant (CI) users with asymmetric or unilateral hearing loss (AHL or UHL). METHODS: Forty adults underwent cochlear implantation as part of a prospective clinical trial assessing the outcomes of CI use in cases of AHL (n = 20) and UHL (n = 20). Subjective measures included the Tinnitus Handicap Inventory (THI), the Speech, Spatial, & Qualities of Hearing Scale (SSQ), and the Abbreviated Profile of Hearing Aid Benefit (APHAB). Responses were obtained preoperatively and at routine intervals out to 5 years post-activation. RESULTS: For subjective benefit, participants with AHL and UHL reported a significant improvement as compared to preoperative abilities, which was maintained with long-term CI use. For perceived tinnitus severity, participants with AHL and UHL reported a significant reduction with CI use as compared to preoperative perceptions. The perceived tinnitus severity significantly differed for the AHL and UHL cohorts over time. This pattern of results is likely influenced by the worse perceived severity levels for the UHL cohort preoperatively and the fluctuating perceived severity levels for some participants in the AHL cohort post-activation. CONCLUSION: Adults with AHL and UHL report an early, significant reduction in perceived tinnitus severity and improvement in quality of life with CI use that is generally maintained with long-term device use. Questionnaires such as the THI, SSQ, and APHAB may contribute to a more holistic assessment of the benefits of cochlear implantation in this population. LEVEL OF EVIDENCE: 2 Laryngoscope, 133:2792-2797, 2023.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Unilateral , Perda Auditiva , Percepção da Fala , Zumbido , Adulto , Humanos , Implante Coclear/métodos , Perda Auditiva/cirurgia , Perda Auditiva Unilateral/cirurgia , Perda Auditiva Unilateral/reabilitação , Estudos Prospectivos , Qualidade de Vida , Percepção da Fala/fisiologia , Zumbido/cirurgia , Resultado do Tratamento
20.
Laryngoscope ; 133(6): 1480-1485, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36053850

RESUMO

OBJECTIVE: To assess long-term binaural hearing abilities for cochlear implant (CI) users with unilateral hearing loss (UHL) or asymmetric hearing loss (AHL). METHODS: A prospective, longitudinal, repeated measures study was completed at a tertiary referral center evaluating adults with UHL or AHL undergoing cochlear implantation. Binaural hearing abilities were assessed with masked speech recognition tasks using AzBio sentences in a 10-talker masker. Performance was evaluated as the ability to benefit from spatial release from masking (SRM). SRM was calculated as the difference in scores when the masker was presented toward the CI-ear (SRMci ) or the contralateral ear (SRMcontra ) relative to the co-located condition (0°). Assessments were completed pre-operatively and at annual intervals out to 5 years post-activation. RESULTS: Twenty UHL and 19 AHL participants were included in the study. Linear Mixed Models showed significant main effects of interval and group for SRMcontra . There was a significant interaction between interval and group, with UHL participants reaching asymptotic performance early and AHL participants demonstrating continued growth in binaural abilities to 5 years post-activation. The improvement in SRM showed a significant positive correlation with contralateral unaided hearing thresholds (p = 0.050) as well as age at implantation (p = 0.031). CONCLUSIONS: CI recipients with UHL and AHL showed improved SRM with long-term device use. The time course of improvement varied by cohort, with the UHL cohort reaching asymptotic performance early and the AHL cohort continuing to improve beyond 1 year. Differences between cohorts could be driven by differences in age at implantation as well as contralateral unaided hearing thresholds. LEVEL OF EVIDENCE: 3 Laryngoscope, 133:1480-1485, 2023.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Unilateral , Perda Auditiva , Percepção da Fala , Adulto , Humanos , Estudos Prospectivos , Audição , Perda Auditiva/cirurgia , Perda Auditiva Unilateral/cirurgia , Perda Auditiva Unilateral/reabilitação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA