Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Cancers (Basel) ; 15(14)2023 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-37509344

RESUMO

XBM was prospectively assessed in spontaneous urine collected just before flexible cystoscopy and washing cytology carried out within the first 2 years follow-up of 337 patients with NMIBC. Recurrences were pathologically confirmed in 49 patients (14.5%), 22 of them being high-risk (6.5%). The XBM sensitivity for detecting any type of recurrence was 69.4% and 63.6% in the cases of high-risk NMIBC. Negative predictive value (NPV) for XBM was 93% for all recurrences and 96.2% for high-risk recurrences. XBM could have avoided 213 invasive controls but missed the detection of 15 recurrences (30.6%)-8 of them of high-risk (36.4%). XBM false positive elevations were detected in 90 patients (26.7%), whereas 10 patients with the invasive method had a false positive result (3%), p <0.001. However, early detection of recurrences during the first year's follow-up after an XBM false positive result was observed in 18 patients (20%). On the other hand, 19 recurrences were detected during this period among the rest of the patients (7.7%)-p = 0.003, and odds ratio (OR) 3.0 (95% CI 1.5-6.0). Regarding one-year follow-up recurrences, 10% were high-risk recurrences in the XBM false positive group and 3.2% in the rest of the patients-p = 0.021, and OR 3.3 (95% CI 1.2-8.9). Additionally, 11.3% of the patients without false positive results developed a recurrence, p = 0.897, for any recurrence, being 10% and 5.2%, respectively, and high-risk and low-risk recurrences, p = 0.506. After searching for the best XBM cutoff for detecting the 38 high-risk initial recurrences and the early high-risk recurrences after a one-year follow-up, a linear discriminant analysis (LDA) of 0.13 could have avoided 11.3% of cystoscopies and bladder wash cytologies, as this cutoff missed only 1 high-risk recurrence (2.6%). More extensive and well-designed studies will confirm if XBM can improve the surveillance of NMIBC.

2.
Rev Esp Patol ; 56(2): 140-143, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37061243

RESUMO

Hybrid neurofibroma/schwannoma is a rare variant of hybrid peripheral nerve sheath tumours (HPNST). A Medline search up to December 2021 identified only six cases of this tumour in the orbit. We report the case of a 78-year-old man who presented with left exophthalmos. Computed tomography showed a left intraconal orbital mass. The clinico-radiological diagnosis was consistent with an intraconal cavernous angioma. Orbitotomy was performed, obtaining an 18×16×11mm mass. Two different morphologies were seen microscopically, diagnostic of hybrid neurofibroma/schwannoma. HPNSTs of the orbit are uncommon and most reported cases showed a hybrid neurofibroma/schwannoma morphology. Hybrid neurofibroma/schwannomas have been associated with neurofibromatosis and schwannomatosis. Local recurrences have been reported. The correct identification of these tumours is important due to their potential use as a syndromic marker.


Assuntos
Neoplasias de Bainha Neural , Neurilemoma , Neurofibroma , Neurofibromatoses , Masculino , Humanos , Idoso , Neurofibroma/patologia , Órbita/patologia , Neoplasias de Bainha Neural/diagnóstico , Neoplasias de Bainha Neural/patologia , Neurilemoma/diagnóstico por imagem , Neurilemoma/patologia
3.
Diagn Cytopathol ; 51(1): 26-35, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35899869

RESUMO

Lung carcinoma remains one of the most frequent and aggressive human neoplasms. Fortunately, in the last decades, the increasing knowledge of the molecular mechanisms leading to cancer development has allowed the use of targeted therapies with improvement of prognosis in many patients. Clinical management has also changed after the introduction of endobronchialultrasonographic bronchoscopy that allows a conservative staging of lung tumors, avoiding the need of mediastinoscopy for lymph node staging. Lung pathologists and cytopathologists are facing the challenge of giving the more comprehensive prognostic and predictive information with ever smaller tissue or cytological samples. The aim of this review is to summarize the molecular testing for non-small cell lung carcinoma and how pathologists can contribute to the patient's outcome with a conscious management of biological samples.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Carcinoma Pulmonar de Células não Pequenas/genética , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/genética , Técnicas de Diagnóstico Molecular
4.
Arch Pathol Lab Med ; 144(7): 878-882, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-31846366

RESUMO

CONTEXT.­: Social media sites are increasingly used for education, networking, and rapid dissemination of medical information, but their utility for facilitating research has remained largely untapped. OBJECTIVE.­: To describe in detail our experience using a social media platform (Twitter) for the successful initiation, coordination, and completion of an international, multi-institution pathology research study. DESIGN.­: Following a tweet describing a hitherto-unreported biopsy-related histologic finding in a mediastinal lymph node following endobronchial ultrasound-guided transbronchial needle aspiration, a tweet was posted to invite pathologists to participate in a validation study. Twitter's direct messaging feature was used to create a group to facilitate communication among participating pathologists. Contributing pathologists reviewed consecutive cases of mediastinal lymph node resection following endobronchial ultrasound-guided transbronchial needle aspiration and examined them specifically for biopsy site changes. Data spreadsheets containing deidentified data and digital photomicrographs of suspected biopsy site changes were submitted via an online file hosting service for central review by 5 pathologists from different institutions. RESULTS.­: A total of 24 pathologists from 14 institutions in 5 countries participated in the study within 143 days of study conception, and a total of 297 cases were collected and analyzed. The time interval between study conception and acceptance of the manuscript for publication was 346 days. CONCLUSIONS.­: To our knowledge, this is the first time that a social media platform has been used to generate a research idea based on a tweet, recruit coinvestigators publicly, communicate with collaborating pathologists, and successfully complete a pathology study.


Assuntos
Adenocarcinoma de Pulmão/patologia , Pesquisa Biomédica , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/efeitos adversos , Neoplasias Pulmonares/patologia , Linfonodos/patologia , Projetos de Pesquisa , Comunicação Acadêmica , Mídias Sociais , Adenocarcinoma de Pulmão/terapia , Comportamento Cooperativo , Fibrose , Humanos , Cooperação Internacional , Neoplasias Pulmonares/terapia , Mediastino , Valor Preditivo dos Testes , Fluxo de Trabalho
5.
Breast ; 16(1): 94-101, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16982194

RESUMO

We reviewed 3226 consecutive core biopsies (CBs) of 3054 mammographically detected breast lesions performed at our Centre from November 1993 to June 2003. CB diagnoses, classified according to the Non-operative Diagnosis Subgroup of the British National Health Service Breast Cancer Screening Programme (NHSBSP), were B5 (37.1%), B4 (0.5%), B3 (7.6%), B2 (50.9%) and B1 (3.9%). It was necessary to repeat the procedure in 172 cases (5.3%). The values for absolute sensitivity and specificity are 90.8% and 83.8%, respectively. The positive predictive value for categories B4 and B5 is 100%, with no false-positives. The positive predictive value for category B3 is 16.3%. The negative predictive value for B2 category is 97.2%, with a false-negative rate of 3.5%. In conclusion, this system of analysis has enabled us to confirm that our CB results surpass the minimum recommended standards proposed by the NHSBSP.


Assuntos
Biópsia por Agulha/classificação , Neoplasias da Mama/patologia , Carcinoma Intraductal não Infiltrante/patologia , Biópsia por Agulha/métodos , Neoplasias da Mama/diagnóstico por imagem , Carcinoma Lobular/patologia , Reações Falso-Negativas , Feminino , Humanos , Mamografia , Valor Preditivo dos Testes , Garantia da Qualidade dos Cuidados de Saúde
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA