Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Rev Med Interne ; 29(5): 415-7, 2008 May.
Artigo em Francês | MEDLINE | ID: mdl-18206271

RESUMO

EKG may be difficult to perform in the elderly. Tremors may induce an EKG pattern suggestive of torsade de pointe. Unexpected good clinical tolerance and appropriate analysis of the EKG allow to correct the diagnosis.


Assuntos
Eletrocardiografia , Torsades de Pointes/fisiopatologia , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Humanos , Masculino , Tremor/fisiopatologia
2.
Chest ; 108(2): 335-9, 1995 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-7634863

RESUMO

In the first part of this study, 61 patients admitted for the first episode or the first recurrence of a spontaneous pneumothorax (SP) were randomly treated with thoracic drainage (TD; 28 patients) or with simple needle aspiration (NA; 33 patients). Success rate of therapy was significantly higher with TD than with NA (93%, CI 84 to 100 vs 67%, CI 51 to 83; p = 0.01). Hospital stay was similar between the two groups (7 +/- 4.6 vs 7 +/- 5.6 days), mainly because NA was delayed by 72 h in 26 patients. Recurrence rates at 3 months were 29% (CI 11 to 47%) after TD, and 14% (CI 0 to 29%) after NA (p > 0.20, NS). In the second part of the study, an additional population of 35 patients was treated by immediate NA, with a success rate of 68.5% (CI 53.5 to 83.5%), and a recurrence rate at 3 months of 30% (CI 10 to 50%). Taken together, our results indicate that NA may be proposed as a first-line treatment of SP, with a successful result in two thirds of patients and recurrence in one fifth of patients. In patients who do not heal with NA, a combined risk of TD failure and short-term recurrence of 50% may be an incentive for undelayed surgical procedures.


Assuntos
Pneumotórax/terapia , Adolescente , Adulto , Tubos Torácicos , Distribuição de Qui-Quadrado , Drenagem/efeitos adversos , Drenagem/métodos , Drenagem/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Agulhas , Estudos Prospectivos , Recidiva , Sucção/efeitos adversos , Sucção/métodos , Sucção/estatística & dados numéricos , Fatores de Tempo
3.
Chest ; 101(2): 583-5, 1992 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-1735303

RESUMO

We present the cases of two young heroin addicts seropositive for HIV who had life-threatening spontaneous acute anterior mediastinitis due to Staphylococcus aureus. This was the consequence of the spreading to the mediastinum of an infection of the chest wall. Complete cure was achieved with antibiotics and surgical drainage. Spontaneous mediastinitis should arouse suspicion of the possibility of HIV infection.


Assuntos
Infecções por HIV/complicações , Dependência de Heroína/complicações , Mediastinite/complicações , Infecções Estafilocócicas/complicações , Doença Aguda , Adulto , Humanos , Masculino , Mediastinite/diagnóstico por imagem , Radiografia , Infecções Estafilocócicas/diagnóstico por imagem
4.
Chest ; 110(3): 846-8, 1996 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8797439

RESUMO

We report three consecutive cases of patients who had refractory hypoxemia and paradoxical embolism during the course of pulmonary embolism. Transesophageal echocardiography showed an atrial septal aneurysm and a patent foramen ovale in all patients. The latter was detected by an early and massive passage of contrast from the right to the left atrium. We suggest that the presence of an atrial septal aneurysm plus a patent foramen ovale greatly enhances both magnitude of shunting and the risk of systemic embolism. The presence of an atrial septal aneurysm plus a patent foramen ovale should be considered and checked using transesophageal echocardiography in every patient with significant pulmonary embolism.


Assuntos
Aneurisma/complicações , Cardiopatias/complicações , Comunicação Interatrial/complicações , Hipóxia/complicações , Embolia Pulmonar/complicações , Idoso , Aneurisma/diagnóstico por imagem , Ecocardiografia Transesofagiana , Feminino , Cardiopatias/diagnóstico por imagem , Comunicação Interatrial/diagnóstico por imagem , Humanos , Fatores de Risco
5.
Chest ; 103(2): 383-5, 1993 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-8432123

RESUMO

To test the hypothesis that the use of protected specimen brushing (PSB) via flexible bronchoscopy does not predispose to bacteremia in ICU patients, we prospectively performed aerobic and anaerobic blood cultures immediately following bronchoscopy with PSB. A total of 123 episodes in 68 consecutive patients with suspected pneumonia were analyzed. Blood cultures were negative in 110 cases (89 percent) and positive in 13 cases (11 percent) (p < 0.001). Twelve of these 13 patients with positive blood cultures had quantitative PSB specimen cultures showing nonsignificant growth (< 10(3) CFU/ml). In nine patients, the bacteria recovered from blood cultures (coagulase-negative staphylococci or sarcina) were considered nonpathogenic according to conventional criteria. Blood cultures grew a Staphylococcus aureus in two patients with previously documented staphylococcal septicemia. In one patient with no identifiable site of infection, the blood culture yielded Enterococcus faecalis. The only patient with both a positive blood culture and PSB culture results indicating pneumonia had different organisms recovered from the two samples. Blood cultures taken after PSB in the 17 other episodes of pneumonia (PSB specimen cultures > or = 10(3) CFU/ml) were negative. At the time of brushing and blood sampling for culture, none of these patients was receiving antibiotics active on the organisms found. In conclusion, the incidence of bacteremia after PSB in ICU patients seems very low even in patients with documented pneumonia. Substantial savings would result from not performing routine blood cultures after PSB.


Assuntos
Bacteriemia/etiologia , Brônquios/microbiologia , Broncoscopia/efeitos adversos , Unidades de Terapia Intensiva , Pneumonia/diagnóstico , Manejo de Espécimes/efeitos adversos , Idoso , Bacteriemia/diagnóstico , Bactérias/isolamento & purificação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
6.
Chest ; 110(5): 1294-8, 1996 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-8915237

RESUMO

Heat and moisture exchangers (HME) are increasingly used to warm and humidify inspired gases in intubated ventilated patients. But these devices add dead space that may alter the alveolar ventilation. This could impair the efficiency of spontaneous ventilation (SV) during weaning trials from mechanical ventilation. Fifteen patients were tested with an HME (Hygrobac-DAR) and a heated humidifier (HH) (Fischer-Paykel MR 450) in a random order during weaning trials in SV with inspiratory pressure support. Minute ventilation VE, tidal volume), and respiratory rate were recorded and arterial blood was sampled for blood gas analysis with each device. The HME gave a significantly greater VE than the HH (9.3 +/- 0.8 L/min vs 8.1 +/- 0.8 L/min; p < 0.005), because of increased respiratory rate (21 +/- 2/min vs 19 +/- 2/min; p < 0.05). Tidal volume was unchanged for HME and HH (470 +/- 32 mL vs 458 +/- 39 mL). The higher PaCO2 with HME than with HH (44 +/- 2 mm Hg vs 42 +/- 2 mm Hg; p < 0.005) revealed an insufficient alveolar ventilation response to the increase in dead space. Arterial Po2 rose with the HME, but not significantly above the HH values (103 +/- 6 mm Hg vs 97 +/- 6 mm Hg; p = 0.055), possibly because of a positive end-expiratory pressure effect of the HME. The need to increase VE in SV when an HME is used should be taken into account during difficult weaning from mechanical ventilation.


Assuntos
Troca Gasosa Pulmonar , Respiração , Desmame do Respirador , Ventiladores Mecânicos , Adulto , Idoso , Idoso de 80 Anos ou mais , Dióxido de Carbono/sangue , Desenho de Equipamento , Feminino , Temperatura Alta , Humanos , Umidade , Inalação , Intubação Intratraqueal , Masculino , Pessoa de Meia-Idade , Oxigênio/sangue , Respiração com Pressão Positiva , Alvéolos Pulmonares/fisiopatologia , Respiração Artificial , Espaço Morto Respiratório , Volume de Ventilação Pulmonar , Água
7.
Chest ; 115(6): 1646-52, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10378563

RESUMO

STUDY OBJECTIVE: To determine the correlation between simple rating of condensation seen in the flex-tube connecting the heating and humidifying device used with the endotracheal tube and hygrometric parameters (absolute and relative humidity and tracheal temperature) measured by psychrometry. DESIGN: Prospective randomized clinical trial. SETTING: Medical ICU of Louis Mourier Hospital, Colombes, France, a university-affiliated teaching hospital. PATIENTS: Forty-five consecutive mechanically ventilated critically ill patients. INTERVENTIONS: Patients undergoing mechanical ventilation were randomly assigned to receive humidification with one of the four heat and moisture exchangers (HMEs) tested or with a conventional heated humidifier. MEASUREMENTS: The hygrometric performances of four HMEs (BB2215, BB50, and BB100 from Pall Biomedical, Saint-Germaine-en-Laye, France; and Hygrobac-Dar from Mallinckrodt, Mirandola, Italy) and a heated humidifier (Fisher & Paykel; Auckland, New Zealand) were studied after 3 h and also after 48 h of use for the Hygrobac-Dar and correlated to a clinical visual inspection rating the amount of condensation in the flex-tube of the endotracheal tube. RESULTS: A total of 95 measurements in 45 patients were performed. The best hygrometric parameters were obtained with the heated humidifier (p < 0.001). The Hygrobac-Dar yielded significantly higher values for both humidities and tracheal temperature than the other three HMEs (p < 0.001). The performance of Hygrobac-Dar was unchanged after 48 h of use. There was a significant correlation between the condensation seen in the flex-tube and the hygrometric parameters measured by psychrometry (absolute humidity, rho = 0.7; relative humidity, rho = 0.7; tracheal temperature, rho = 0.5, p < 0.0001). CONCLUSION: In mechanically ventilated ICU patients, visual evaluation of the condensation in the flex-tube provides an estimation of the heating and humidifying efficacy of the heating and humidifying device used, thus allowing the clinician bedside monitoring of airway humidification.


Assuntos
Umidade , Sistemas Automatizados de Assistência Junto ao Leito , Respiração Artificial/métodos , Insuficiência Respiratória/terapia , Doença Aguda , Temperatura Corporal , Estado Terminal , Temperatura Alta , Humanos , Unidades de Terapia Intensiva , Intubação Intratraqueal , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Respiração Artificial/normas , Traqueia/fisiologia
8.
Am J Hypertens ; 10(1): 24-31, 1997 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9008245

RESUMO

Seven normotensive untreated patients with obstructive sleep apnea (OSA) and five control subjects without OSA were compared. Patients with cardiac dilation, chronic airflow limitation, liver and kidney disease, or diabetes mellitus were excluded. Change in pressure-heart rate relation to alpha-adrenergic stimulation (P-HRR), extracellular volume (ECV), and plasma volume (Vp) were measured during daytime. Plasma atrial natriuretic peptide (ANP), plasma renin and aldosterone concentrations were obtained at 1 hour intervals during the night. A mean apnea/hypopnea index (AHI) of 52.2 +/- 23.9/h and a mean lowest arterial oxygen saturation (SaO2) of 61.2 +/- 19.3% (mean +/- SD) were determined from polysomnographic monitoring in the patient group. Release of ANP was significantly higher during sleep in OSA patients than in control subjects (P < .01), with a maximum concentration between 4 and 6 AM in the former. Daytime ECV was significantly higher (P < .05) and Vp significantly lower (P < .05) in OSA patients. Night maximum concentration of ANP (max ANP) was negatively related to AHI (P < .05). P-HRR was negatively related to AHI (P < .05) and positively related to max ANP (P < .05). In conclusion, OSA syndrome alters hormonal system control of body fluid compartment regulation. The decreased response in night max ANP secretion in the most severe OSA patients could be explained by the smaller Vp observed in these patients, decreasing atrial and ventricular pressure loading. Furthermore, alteration of P-HRR, correlated to AHI and max ANP, strengthens the hypothesis that patients who develop hypertension are those in whom the protective mechanism of ANP release failed.


Assuntos
Agonistas alfa-Adrenérgicos/administração & dosagem , Pressão Sanguínea/efeitos dos fármacos , Frequência Cardíaca/efeitos dos fármacos , Síndromes da Apneia do Sono/fisiopatologia , Adulto , Aldosterona/sangue , Fator Natriurético Atrial/sangue , Humanos , Pessoa de Meia-Idade , Renina/sangue , Síndromes da Apneia do Sono/sangue , Síndromes da Apneia do Sono/tratamento farmacológico
9.
Intensive Care Med ; 23(7): 753-9, 1997 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9290989

RESUMO

OBJECTIVE: The determination of basal cardiac output (CO) and of its variations during different therapeutic interventions liable to increase or decrease it in mechanically ventilated patients using transesophageal echocardiography (TEE). DESIGN: To compare CO measurements simultaneously obtained by transmitral single-plane TEE and thermodilution. SETTING: Medical intensive care unit. PATIENTS: Twenty-two consecutive mechanically ventilated patients hospitalized for various medical conditions were included. INTERVENTIONS: The comparisons between transmitral single-plane TEE and thermodilution measurements were made at baseline and after different therapeutic interventions affecting CO (fluids or dobutamine infusion or positive end-expiratory pressure titration). MEASUREMENTS: Seventy-four measurements were obtained. Cardiac output using TEE was the product of the mitral valve area, the time-velocity integral of flow at the same site and the heart rate. RESULTS: A significant correlation was observed between thermodilution and TEE measurements of CO (n = 74, r = 0.78, p < 0.001) despite wide limits of agreement (mean +/- 2SD = -0.3 +/- 3.1 l/min). Thermodilution and TEE CO determinations both had significant inverse correlation with the arterial-venous oxygen content difference in ten consecutive patients (r = 0.77, p < 0.01 and r = 0.71, p < 0.01, respectively). The correlation between variations of CO greater than 20% obtained by thermodilution and TEE was significant (r = 0.89, p < 0.001). The operative characteristics implied the ability of TEE to predict significant variations of thermodilution CO (sensitivity 85% and negative predictive values 86%). Moreover, arterial-venous oxygen content difference changes of 5% or more were better detected using TEE than thermodilution. CONCLUSIONS: These results suggest that although transesophageal CO measurements cannot replace thermodilution ones, the determination of CO variations obtained using TEE may be useful in the management of critically ill mechanically ventilated patients. This technique may make it possible to monitor hemodynamics during initial therapeutic interventions in those patients in whom right heart catheterization cannot be performed immediately.


Assuntos
Débito Cardíaco , Ecocardiografia Transesofagiana/normas , Respiração Artificial , Termodiluição/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Gasometria , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo
10.
Intensive Care Med ; 19(5): 279-84, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-8408937

RESUMO

OBJECTIVE: To evaluate the bacteriology of early aspiration pneumonia using a protected specimen brush and quantitative culture techniques, and whether penicillin G is adequate as initial treatment pending culture results. PATIENTS AND METHODS: 52 patients (of which 45 required mechanical ventilation) meeting usual clinical criteria for aspiration pneumonia were prospectively included. On admission, patients were given intravenous penicillin G and a protected specimen brush was performed < or = 48 h after. RESULTS: Cultures of the brush were negative (< 10(3) CFU/ml) in 33 patients (1 had blood cultures positive with S. pneumoniae) and positive (> or = 10(3) CFU/ml) for S. pneumoniae in 2 patients. Seventeen patients had a positive culture (> or = 10(3) CFU/ml) for at least one penicillin G resistant microorganism, with a total of 20 organisms (S. aureus: 6; H. influenzae: 2; Enterobacteriaceae: 8; P. aeruginosa: 3; C. albicans: 1). In 4 of these patients, a penicillin-sensitive pathogen was also recovered in significant concentrations (S. pneumoniae: 2; Streptococcus sp.: 2). These 17 patients with a resistant pathogen did not differ from the 35 other patients with respect to need for ventilatory support and mortality rate. By contrast, they were older (61.1 +/- 21.9 vs. 42.9 +/- 18.8 years; p < 0.005) and required longer mechanical ventilation (6.1 +/- 4.6 vs. 3.5 +/- 2.7 days; p < 0.03) and hospitalization (11.2 +/- 8.8 vs. 6.7 +/- 4.7 days; p < 0.02). Of 17 patients 12 with penicillin G resistant organisms versus 0/35 without, were in-hospital patients and/or had a digestive disorder (p < 0.001). CONCLUSION: The broad range of offending organisms seen in early aspiration pneumonia precludes use of any single empiric regimen, making protected specimen brush mandatory in many patients. Nevertheless, the involvement of S.pneumoniae in a notable proportion of our patients suggests that routine penicillin prophylaxis after early aspiration (at least in most patients with community-acquired aspiration) is warranted given the potential severity of pneumococcal sepsis in such patients.


Assuntos
Broncoscópios , Infecções Comunitárias Adquiridas/tratamento farmacológico , Infecções Comunitárias Adquiridas/microbiologia , Infecção Hospitalar/tratamento farmacológico , Infecção Hospitalar/microbiologia , Penicilina G/uso terapêutico , Pneumonia Aspirativa/tratamento farmacológico , Pneumonia Aspirativa/microbiologia , Manejo de Espécimes/instrumentação , Adulto , Fatores Etários , Idoso , Assepsia/instrumentação , Infecções Comunitárias Adquiridas/diagnóstico , Infecções Comunitárias Adquiridas/epidemiologia , Comorbidade , Infecção Hospitalar/diagnóstico , Infecção Hospitalar/epidemiologia , Doenças do Sistema Digestório/epidemiologia , Resistência Microbiana a Medicamentos , Feminino , Mortalidade Hospitalar , Humanos , Infusões Intravenosas , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Penicilina G/farmacologia , Pneumonia Aspirativa/diagnóstico , Pneumonia Aspirativa/epidemiologia , Prognóstico , Estudos Prospectivos , Respiração Artificial/estatística & dados numéricos
12.
Am Rev Respir Dis ; 146(2): 295-9, 1992 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-1489115

RESUMO

The management of patients with unilateral pneumonia and severe hypoxemia often represents a therapeutic challenge. Mechanical ventilation with the diseased lung uppermost may improve gas exchange, but it is not devoid of adverse effects. No hemodynamic measurements have been reported in patients ventilated in this manner; therefore, whether or not the improvement in PaO2 is counterbalanced by hemodynamic deterioration remains unknown. Almitrine bismesylate is a drug that seems able to improve gas exchange in patients with chronic obstructive pulmonary disease or the adult respiratory distress syndrome. The increase in PaO2 after its administration has been attributed to an improvement in ventilation-perfusion relationships. Its use has never been reported during unilateral pneumonia with severe hypoxemia. We therefore compared its effects with those of lateral position in eight consecutive mechanically ventilated patients with unilateral pneumonia. Blood gas and hemodynamic measurements were performed both at maintenance FIO2 and at an FIO2 of 1.0. Almitrine (1 mg/kg over 1 h) had no effect on PaO2 under either FIO2 condition. Cardiac output remained unchanged, but mean pulmonary artery pressure increased from 22.5 +/- 1.2 to 26.5 +/- 1.3 mm Hg (p < 0.02). By contrast, lateral position had striking effects on PaO2, which increased from 100 +/- 14 mm Hg in supine position to 156 +/- 23 mm Hg (p < 0.01) when the abnormal lung was placed uppermost at maintenance FIO2 and from 207 +/- 21 (supine) to 300 +/- 28 mm Hg (lateral) (p < 0.01) at FIO2 1.0.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Almitrina/uso terapêutico , Infecções Bacterianas/terapia , Hipóxia/terapia , Pneumonia/terapia , Postura , Adulto , Almitrina/administração & dosagem , Almitrina/farmacologia , Infecções Bacterianas/complicações , Infecções Bacterianas/fisiopatologia , Gasometria , Feminino , Hemodinâmica/efeitos dos fármacos , Humanos , Hipóxia/etiologia , Hipóxia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Oximetria , Pneumonia/complicações , Pneumonia/fisiopatologia , Estudos Prospectivos , Troca Gasosa Pulmonar/efeitos dos fármacos , Relação Ventilação-Perfusão/efeitos dos fármacos
13.
Am Rev Respir Dis ; 147(4): 946-51, 1993 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8466131

RESUMO

In patients with clinical suspicion of pneumonia, quantitative cultures of protected brushing specimens (PBS) yielding > or = 10(3) CFU/ml of at least one microorganism have been found useful for differentiating airway colonization and lung infection, especially in mechanically ventilated patients. The amount of secretions collected by protected catheter brushing is small and difficult to determine accurately. Thus, the clinical significance of PBS cultures yielding organisms in concentrations > or = 10(2) but < 10(3) CFU/ml, in the absence of active antimicrobial treatment, is unknown. The 34 consecutive results of PBS cultures yielding organisms in concentrations > or = 10(2) but < 10(3) CFU/ml in 30 patients under mechanical ventilation or weaned for < or = 4 days were prospectively studied. No patients were receiving agents active on the organism recovered. In 5 cases, the diagnosis of pneumonia was ruled out by recovery without treatment (n = 4) or negative postmortem lung cultures (n = 1). A second PBS was cultured in 29 episodes (2.7 +/- 1.8 days after the first PBS). In 12 instances (Group 1), cultures of the second PBS yielded > or = 10(3) CFU/ml of the same organism as that found in the first PBS (S. pneumoniae, 1; S. aureus, 1; H. influenzae, 1; E. coli, 1; P. aeruginosa, 4; and A. baumannii, 4), and these patients were therefore treated with appropriate antibiotics. A total of 17 patients had a negative repeat PBS culture (no growth or trivial concentrations) and were considered free of pneumonia and given no antibiotic treatment for this episode.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Técnicas Bacteriológicas/instrumentação , Pneumonia/microbiologia , Manejo de Espécimes/instrumentação , Bactérias/crescimento & desenvolvimento , Contagem de Colônia Microbiana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pneumonia/diagnóstico , Estudos Prospectivos , Respiração Artificial
14.
Am Rev Respir Dis ; 143(4 Pt 1): 738-43, 1991 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-2008985

RESUMO

Circuits on mechanical ventilators with cascade humidifiers are routinely changed every day or every other day, although humidifying cascades have been considered unlikely to increase the risk of respiratory infection because they do not generate aerosols. Moreover, changing ventilator tubings every 24 rather than every 48 h increases the risk of ventilator-associated pneumonia. To study the effects of ventilator circuit changes on the rate of nosocomial pneumonia and on patient and circuit colonization, 73 consecutive patients requiring continuous mechanical ventilation for more than 48 h were randomly assigned to either ventilator circuit changes every 48 h (Group 1, n = 38) or no change (Group 2, n = 35). Patients dying or being weaned before 96 h were not analyzed (Group 1 n = 3; Group 2 n = 7; leaving Group 1 n = 35 and Group 2 n = 28; p = 0.13). Ventilator-associated pneumonia was defined as the occurrence during mechanical ventilation or within 48 h after weaning of a new and persistent infiltrate on chest X-ray, purulent tracheal secretions, and a positive culture of a protected brush specimen (greater than or equal to 10(3) cfu/ml). Bacterial colonization was assessed every 48 h by quantitative cultures of pharyngeal swab, tracheal aspirate, humidifying cascade, and expiratory tubing trap. The two groups were similar in terms of age, indication for and duration of ventilation, and severity of illness.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Infecções Bacterianas/etiologia , Infecção Hospitalar/etiologia , Pneumonia/etiologia , Respiração Artificial/efeitos adversos , Idoso , Bactérias/isolamento & purificação , Infecções Bacterianas/microbiologia , Infecção Hospitalar/microbiologia , Contaminação de Equipamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Faringe/microbiologia , Pneumonia/microbiologia , Estudos Prospectivos , Respiração Artificial/métodos , Traqueia/microbiologia
15.
Am J Respir Crit Care Med ; 161(1): 104-9, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10619805

RESUMO

The cost of mechanical ventilation (MV) is high. Efforts to reduce this cost, as long as they are not detrimental for the patients, are needed. MV with heat and moisture exchangers (HME) changed every 48 h is safe, efficient, and cost-effective. Preliminary reports suggest that the life span of these filters may be prolonged. We determined prospectively whether a hygroscopic and hydrophobic HME (Hygrobac-Dar; Mallinckrodt) provided safe and efficient heating and humidification of the inspired gases when changed only once a week. Patients who were considered to require mechanical ventilation for more than 48 h were included in the study. HMEs were initially set for 7 d. Efficient airway heating and humidification were assessed by clinical parameters (number of tracheal suctionings and instillations required, peak airway pressures) and hygrometric measurements performed by psychrometry. Resistance was measured from Day 0 to Day 7. Bacterial colonization of circuits and HMEs was studied. A total of 377 days of mechanical ventilation with 60 HMEs was studied. Clinical parameters and hygrometric measurements did not change between Day 0 and Day 7. Mean absolute humidity was 30.3 +/- 1.3 mg H(2)O/L on Day 0 and 30.8 +/- 1.5 mg H(2)O/L on Day 7 (p = 0.7). Endotracheal tube occlusion never occurred. Three HMEs were replaced prematurely because of insufficient absolute humidity. This rare event occurred only in patients with COPD and after the third day of use. In addition, the absolute humidity delivered by the HMEs was significantly lower in patients with COPD than in the rest of the population. Resistance did not change from Day 0 to Day 7 (2.4 +/- 0.3 versus 2.7 +/- 0.3 cm H(2)O/L/s; p = 0.4). Bacterial samples of both circuits and ventilator sides of HMEs were sterile in most cases. We conclude that mechanical ventilation can be safely conducted in non-COPD patients using an HME changed only once a week, leading to substantial cost savings (about $110,000 per year if these findings were applied to the university-affiliated hospitals in Paris).


Assuntos
Equipamentos Descartáveis , Filtração/instrumentação , Temperatura Alta , Umidade , Respiração Artificial/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Resistência das Vias Respiratórias , Bactérias/crescimento & desenvolvimento , Bactérias/isolamento & purificação , Infecções Bacterianas/prevenção & controle , Contagem de Colônia Microbiana , Análise Custo-Benefício , Equipamentos Descartáveis/microbiologia , Contaminação de Equipamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/terapia , Respiração Artificial/economia , Respiração Artificial/instrumentação , Unidades de Cuidados Respiratórios , Segurança
16.
Crit Care Med ; 28(3): 665-71, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10752812

RESUMO

OBJECTIVE: To determine whether three hydrophobic and hygroscopic heat and moisture exchangers (HMEs) retain their heating and humidifying properties (assessed by psychrometric measurements of absolute humidity, relative humidity, and tracheal temperature) for 48 hrs without any drop in their bacteriologic efficiency. DESIGN: Prospective randomized clinical trial. PATIENTS: Sixty-one consecutive unselected mechanically ventilated intensive care unit patients. INTERVENTIONS: Patients were randomly allocated to one of the three HMEs studied (Hygrobac-Dar from Mallinckrodt, n = 21; Humid-Vent from Gibeck, n = 20; and Clear-Thermal from Intersurgical, n = 20). MEASUREMENTS AND MAIN RESULTS: Hygrometric parameters were measured by psychrometry after 3, 24, and 48 hrs of use. Peak airway pressure was recorded every 6 hrs and averaged over 24 hrs. Bacterial colonization of both patients and circuits was studied. Patients in all three groups were similar in terms of age, indications for, and overall duration of mechanical ventilation. Tracheal tube occlusion never occurred. Hygrometric data included 371 measurements whereas bacteriologic data included >700 samples and cultures. The Hygrobac-Dar HMEs gave a significantly higher absolute humidity whatever the time of measurement (3, 24, or 48 hrs) than the other two HMEs (p < .001). The Clear-Thermal HMEs gave the poorest hygrometric parameters (p < .01); five of them were replaced prematurely (24 hrs) because the absolute humidity was <25 mg H2O/L. This did not occur for the other HMEs. Mean peak airway pressures were identical in the three groups. The bacterial colonizations of both patient and circuit were similar (and negligible for circuits) for all three groups. CONCLUSION: Some HMEs may be used safely for 48 hrs without change. However, this does not pertain to every brand of HME. Objective in vivo evaluation of their humidifying performances is decisive before extending their duration of use.


Assuntos
Respiração Artificial/instrumentação , Avaliação da Tecnologia Biomédica , Doença Aguda , Análise de Variância , Contagem de Colônia Microbiana , Análise Custo-Benefício , Segurança de Equipamentos , Feminino , Filtração , Humanos , Umidade , Pneumopatias Obstrutivas/terapia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Respiração Artificial/economia , Insuficiência Respiratória/terapia , Fatores de Tempo , Molhabilidade
17.
Am J Respir Crit Care Med ; 151(4): 986-92, 1995 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-7697277

RESUMO

The contribution of ventilator circuit bacterial contamination to the occurrence of ventilator-associated pneumonia remains controversial. In a previous study, we found that the incidence of pneumonia was identical with ventilator circuit changes every 48 h and with no ventilator circuit changes. The present study prospectively assessed whether keeping ventilator circuits clean with a heat and moisture exchanger exhibiting antimicrobial barrier properties affects patient colonization and the incidence of nosocomial pneumonia in patients receiving mechanical ventilation for more than 48 h. Consecutive patients were randomly allocated to humidification with either a heat and moisture exchanger (Group 1, n = 61) or a heated humidifier (Group 2, n = 70). In both groups, no circuit changes were performed throughout ventilatory support. Duration of mechanical ventilation was identical in both groups (10 +/- 8.6 d (range: 2 to 47) in Group 1 and 12.5 +/- 14.2 d [range: 2 to 85] in Group 2). The incidence of pneumonia (positive quantitative culture of protected brush specimen) was similar in both groups (6/61 and 8/70 in Groups 1 and 2, respectively; p = 0.8), as was duration of ventilation prior to pneumonia (9 +/- 5.9 versus 8.2 +/- 5.7 d; p = 0.8). Ventilator tubing contamination was considerably reduced with the use of a heat and moisture exchanger. In contrast, bacterial colonization of the pharynx and trachea was identical in both groups. These results suggest that circuit colonization plays little or no role in the occurrence of ventilator-associated pneumonia, provided usual maintenance precautions are applied.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Infecção Hospitalar/etiologia , Contaminação de Equipamentos , Pneumonia Bacteriana/etiologia , Respiração Artificial/instrumentação , Adulto , Idoso , Cuidados Críticos , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/prevenção & controle , Contaminação de Equipamentos/prevenção & controle , Feminino , Temperatura Alta , Humanos , Umidade , Incidência , Masculino , Pessoa de Meia-Idade , Pneumonia Bacteriana/epidemiologia , Pneumonia Bacteriana/prevenção & controle , Estudos Prospectivos
18.
Am J Respir Crit Care Med ; 152(5 Pt 1): 1562-9, 1995 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-7582295

RESUMO

Heat and moisture exchangers (HME) (Dar-Hygrobac II, Peters) can safely be used every 24 h for long-term mechanical ventilation and provide a cost-saving alternative to heated humidifiers. We have prospectively determined whether changing HMEs every 48 h only affects their clinical and bacteriological efficiency in a series of consecutive nonselected ICU patients requiring long-term mechanical ventilation. Two consecutive periods were compared. During period 1, HMEs were replaced every day; during period 2, they were changed every 48 h. Patients from the two periods were similar in terms of age and indication for and overall duration of MV (10 +/- 8.6 versus 10 +/- 9 d, p = 0.9). Minute ventilation and maximum values for peak airway pressure were identical during the two periods. These values were also identical after 1 and 2 d of HME use during period 2, indicating that HME resistance was not increased by prolonged use. Obstruction of the tracheal tube occurred only once in a period 1 patient. The results of quantitative cultures indicate that the maximum and mean levels of bacterial colonization during the two periods were similar for the pharynx, trachea, Y-connector, patient, and ventilator side of the HME. More importantly, the incidence of nosocomial pneumonia was similar during the two periods (6/61 versus 8/68, p = 0.7). Thus, prolonged HME use is safe and provides a substantial reduction in the cost of mechanical ventilation.


Assuntos
Infecção Hospitalar/prevenção & controle , Pneumonia Bacteriana/prevenção & controle , Respiração Artificial/instrumentação , Adulto , Idoso , Análise Custo-Benefício , Infecção Hospitalar/diagnóstico , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/microbiologia , Contaminação de Equipamentos/prevenção & controle , Contaminação de Equipamentos/estatística & dados numéricos , Estudos de Avaliação como Assunto , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Pneumonia Bacteriana/diagnóstico , Pneumonia Bacteriana/epidemiologia , Pneumonia Bacteriana/microbiologia , Estudos Prospectivos , Respiração Artificial/economia , Respiração Artificial/estatística & dados numéricos , Segurança , Fatores de Tempo
19.
Am J Respir Crit Care Med ; 161(6): 1942-8, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10852771

RESUMO

We investigated the incidence, risk factors for, and outcome of ventilator-associated pneumonia (VAP) in patients with acute respiratory distress syndrome (ARDS). We compared 134 patients with ARDS with 744 patients without ARDS on mechanical ventilation. Fiberoptic bronchoscopic examination and quantitative bacterial cultures (protected brush or catheter sampling [threshold: 10(3) cfu/ml], or bronchoalveolar lavage [threshold: 10(4) cfu/ml]) were used to diagnose pneumonia. VAP occurred in 49 patients (36.5%). The incidence of pneumonia was 23% (173 of 744 patients) among patients without ARDS (p < 0.002). Nonfermenting gram-negative rods caused significantly more pneumonia in ARDS patients. Mortality rates were identical in ARDS patients with (28 of 49 patients, 57%) and without (50 of 85 patients, 59%) pulmonary infection (p = 0.8). VAP resulted in a considerable increase in attributable time on mechanical ventilation of both the overall population of ARDS patients and of survivors. Both the use of sucralfate (adjusted odds ratio [OR]: 4. 42; 95% confidence interval [CI]: 2.01 to 9.7, p = 0.0002) and the duration of exposure to sucralfate (adjusted OR: 1.206; 95% CI: 1. 095 to 1.328, p = 0.0002) were associated with an increased risk of VAP during ARDS. VAP considerably prolongs the time on mechanical ventilation without affecting survival. Patients given sucralfate may be at greater risk of developing pulmonary infection during ARDS.


Assuntos
Infecção Hospitalar/epidemiologia , Pneumonia Bacteriana/epidemiologia , Síndrome do Desconforto Respiratório/terapia , Ventiladores Mecânicos , Adulto , Idoso , Antiulcerosos/administração & dosagem , Antiulcerosos/efeitos adversos , Infecção Hospitalar/diagnóstico , Infecção Hospitalar/etiologia , Estudos Transversais , França/epidemiologia , Humanos , Incidência , Unidades de Terapia Intensiva , Pessoa de Meia-Idade , Pneumonia Bacteriana/diagnóstico , Pneumonia Bacteriana/etiologia , Prognóstico , Fatores de Risco , Sucralfato/administração & dosagem , Sucralfato/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA