Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Biomed Microdevices ; 26(1): 7, 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-38175269

RESUMO

An investigation was conducted to examine the effect of magnetic bead (MB) size on the effectiveness of isolating lung cancer cells using the immunomagnetic separation (IMS) method in a serpentine microchannel with added cavities (SMAC) structure. Carboxylated magnetic beads were specifically conjugated to target cells through a modification procedure using aptamer materials. Cells immobilized with different sizes (in micrometers) of MBs were captured and isolated in the proposed device for comparison and analysis. The study yields significance regarding the clarification of device working principles by using a computational model. Furthermore, an accurate evaluation of the MB size impact on capture efficiency was achieved, including the issue of MB-cell accumulation at the inlet-channel interface, despite it being overlooked in many previous studies. As a result, our findings demonstrated an increasing trend in binding efficiency as the MB size decreased, evidenced by coverages of 50.5%, 60.1%, and 73.4% for sizes of 1.36 µm, 3.00 µm, and 4.50 µm, respectively. Additionally, the overall capture efficiency (without considering the inlet accumulation) was also higher for smaller MBs. However, when accounting for the actual number of cells entering the channel (i.e., the effective capture), larger MBs showed higher capture efficiency. The highest effective capture achieved was 88.4% for the size of 4.50 µm. This research provides an extensive insight into the impact of MB size on the performance of IMS-based devices and holds promise for the efficient separation of circulating cancer cells (CTCs) in practical applications.


Assuntos
Neoplasias Pulmonares , Células Neoplásicas Circulantes , Humanos , Separação Imunomagnética , Ácidos Carboxílicos , Fenômenos Magnéticos
2.
Analyst ; 148(9): 1912-1929, 2023 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-36928639

RESUMO

Microfluidic cytometry (MC) and electrical impedance spectroscopy (EIS) are two important techniques in biomedical engineering. Microfluidic cytometry has been utilized in various fields such as stem cell differentiation and cancer metastasis studies, and provides a simple, label-free, real-time method for characterizing and monitoring cellular fates. The impedance microdevice, including impedance flow cytometry (IFC) and electrical impedance spectroscopy (EIS), is integrated into MC systems. IFC measures the impedance of individual cells as they flow through a microfluidic device, while EIS measures impedance changes during binding events on electrode regions. There have been significant efforts to improve and optimize these devices for both basic research and clinical applications, based on the concepts, electrode configurations, and cell fates. This review outlines the theoretical concepts, electrode engineering, and data analytics of these devices, and highlights future directions for development.


Assuntos
Técnicas Analíticas Microfluídicas , Microfluídica , Ciência de Dados , Eletrodos , Diferenciação Celular , Impedância Elétrica , Espectroscopia Dielétrica/métodos , Técnicas Analíticas Microfluídicas/métodos
3.
Biomed Microdevices ; 23(4): 51, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34596785

RESUMO

The manipulation and separation of circulating tumor cells (CTCs) in continuous fluidic flows play an essential role in various biomedical applications, particularly the early diagnosis and treatment of diseases. Recent advances in magnetic bead development have provided promising solutions to the challenges encountered in CTC manipulation and isolation. In this study, we proposed a biomicrofluidic platform for specifically isolating human lung carcinoma A549 cells in microfluidic channels. The principle of separation was based on the effect of the magnetic field on aptamer-conjugated magnetic beads, also known as immunomagnetic beads, in a serpentine microchannel with added cavities (SMAC). The magnetic cell separation performance of the proposed structure was modeled and simulated by using COMSOL Multiphysics. The experimental procedures for aptamer molecular conjugation on 1.36 µm-diameter magnetic beads and magnetic bead immobilization on A549 cells were also reported. The lung carcinoma cell-bead complexes were then experimentally separated by an external magnetic field. Separation performance was also confirmed by optical microscopic observations and fluorescence analysis, which showed the high selectivity and efficiency of the proposed system in the isolation and capture of A549 cells in our proposed SMAC. At the flow rate of 5 µL/s, the capture rate of human lung carcinoma cells exceeded 70% in less than 15 min, whereas that of the nontarget cells was approximately 4%. The proposed platform demonstrated its potential for high selectivity, portability, and facile operation, which are suitable considerations for developing point-of-care applications for various biological and clinical purposes.


Assuntos
Adenocarcinoma de Pulmão , Neoplasias Pulmonares , Células Neoplásicas Circulantes , Linhagem Celular Tumoral , Separação Celular , Humanos , Separação Imunomagnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA