1.
Phys Med Biol ; 69(5)2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38271728

RESUMO

Objective. This study aims to develop and assess a tumor contraction model, enhancing the precision of ablative margin (AM) evaluation after microwave ablation (MWA) treatment for hepatocellular carcinomas (HCCs).Approach. We utilize a probabilistic method called the coherent point drift algorithm to align pre-and post-ablation MRI images. Subsequently, a nonlinear regression method quantifies local tumor contraction induced by MWA, utilizing data from 47 HCC with viable ablated tumors in post-ablation MRI. After automatic non-rigid registration, correction for tumor contraction involves contracting the 3D contour of the warped tumor towards its center in all orientations.Main results. We evaluate the performance of our proposed method on 30 HCC patients who underwent MWA. The Dice similarity coefficient between the post-ablation liver and the warped pre-ablation livers is found to be 0.95 ± 0.01, with a mean corresponding distance between the corresponding landmarks measured at 3.25 ± 0.62 mm. Additionally, we conduct a comparative analysis of clinical outcomes assessed through MRI over a 3 month follow-up period, noting that the AM, as evaluated by our proposed method, accurately detects residual tumor after MWA.Significance. Our proposed method showcases a high level of accuracy in MRI liver registration and AM assessment following ablation treatment. It introduces a potentially approach for predicting incomplete ablations and gauging treatment success.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Micro-Ondas/uso terapêutico , Ablação por Cateter/métodos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos
2.
Comput Methods Programs Biomed ; 257: 108383, 2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-39260163

RESUMO

INTRODUCTION: This study aimed to investigate the efficacy of a small-gauge microwave ablation antenna (MWA) with an enhanced cooling system (ECS) for generating more spherical ablation zones. METHODS: A comparison was made between two types of microwave ablation antennas, one with ECS and the other with a conventional cooling system (CCS). The finite element method was used to simulate in vivo ablation. Two types of antennas were used to create MWA zones for 5, 8, 10 min at 50, 60, and 80 W in ex vivo bovine livers (n = 6) and 5 min at 60 W in vivo porcine livers (n = 16). The overtreatment ratio, ablation aspect ratio, carbonization area, and other characteristcs of antennas were measured and compared using numerical simulation and gross pathologic examination. RESULTS: In numerical simulation, the ECS antenna demonstrated a lower overtreatment ratio than the CCS antenna (1.38 vs 1.43 at 50 W 5 min, 1.19 vs 1.35 at 50 W 8 min, 1.13 vs 1.32 at 50 W 10 min, 1.28 vs 1.38 at 60 W 5 min, 1.14 vs 1.32 at 60 W 8 min, 1.10 vs 1.30 at 60 W 10 min). The experiments revealed that the ECS antenna generated ablation zones with a more significant aspect ratio (0.92 ± 0.03 vs 0.72 ± 0.01 at 50 W 5 min, 0.95 ± 0.02 vs 0.70 ± 0.01 at 50 W 8 min, 0.96 ± 0.01 vs 0.71 ± 0.04 at 50 W 10 min, 0.96 ± 0.01 vs 0.73 ± 0.02 at 60 W 5 min, 0.94 ± 0.03 vs 0.71 ± 0.03 at 60 W 8 min, 0.96 ± 0.02 vs 0.69 ± 0.04 at 60 W 10 min) and a smaller carbonization area (0.00 ± 0.00 cm2 vs 0.54 ± 0.06 cm2 at 50 W 5 min, 0.13 ± 0.03 cm2 vs 0.61 ± 0.09 cm2 at 50 W 8 min, 0.23 ± 0.05 cm2 vs 0.73 ± 0.05 m2 at 50 W 10 min, 0.00 ± 0.00 cm2 vs 1.59 ± 0.41 cm2 at 60 W 5 min, 0.23 ± 0.22 cm2 vs 2.11 ± 0.63 cm2 at 60 W 8 min, 0.57 ± 0.09 cm2 vs 2.55 ± 0.51 cm2 at 60 W 10 min). Intraoperative ultrasound images revealed a hypoechoic area instead of a hyperechoic area near the antenna. Hematoxylin-eosin staining of the dissected tissue revealed a correlation between the edge of the ablation zone and that of the hypoechoic area. CONCLUSIONS: The ECS antenna can produce more spherical ablation zones with less charring and a clearer intraoperative ultrasound image of the ablation area than the CCS antenna.

3.
Abdom Radiol (NY) ; 44(8): 2909-2915, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31089779

RESUMO

PURPOSE: We aimed to explore the feasibility of microwave ablation (MWA) assisted by three-dimensional visualization system for relapsed HB in children. METHODS: From August 2014 to February 2017, five patients with relapsed HB were enrolled. A total of 12 liver tumors were treated with MWA assisted by a three-dimensional visualization system. Follow-up data were obtained in all patients. The residual liver volume, local tumor progression, new intrahepatic tumors, survival outcome, and complications were analyzed. RESULTS: All tumors were completely ablated in a single session. The mean ablation time per tumor was 9.7 ± 8.6 min, and the median ablation/liver volume ratio was 2.37%. No local tumor progression was observed during a follow-up period of 9-39 months. All patients were still alive at the end of the follow-up. The median progression-free survival time after ablation was 9 months, and the median survival time after ablation was 12 months. No other complications were observed except for fever. CONCLUSIONS: MWA assisted by three-dimensional visualization system appears to be a safe and feasible local treatment for recurrent HB in pediatric patients.


Assuntos
Ablação por Cateter/métodos , Hepatoblastoma/diagnóstico por imagem , Hepatoblastoma/cirurgia , Imageamento Tridimensional , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética , Micro-Ondas/uso terapêutico , Adolescente , Criança , Pré-Escolar , Progressão da Doença , Estudos de Viabilidade , Feminino , Hepatoblastoma/mortalidade , Humanos , Neoplasias Hepáticas/mortalidade , Masculino , Estudos Retrospectivos , Taxa de Sobrevida
4.
Abdom Radiol (NY) ; 44(6): 2293-2300, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30919040

RESUMO

PURPOSE: To evaluate the effects of ablation strategies on local tumor progression (LTP) after microwave ablation (MWA) of hepatocellular carcinomas (HCCs) measuring 3-5 cm. MATERIALS AND METHODS: Between December 2011 and May 2017, 71 HCC patients with 71 nodules treated by ultrasound(US)-guided percutaneous MWA were divided into parallel (group A) and crossed (group B) antenna placement groups. All patients underwent MWA using two antennas with four insertions. LTP and overall survival (OS) rates were compared between the two groups. RESULTS: The median follow-up time was 16.8 months. There was no significant difference in the complete ablation rate and treatment sessions between the two groups. LTP was diagnosed in 8 of 48 nodules (16.7%) in group A and 1 of 23 nodules (4.3%) in group B, with no significant difference between two groups (P = 0.115). The 1-, 2-, and 3-year OS rates were 88.5%, 79%, and 71.8% in group A and 93.8%, 87.5%, and 87.5% in group B, respectively (P = 0.236). Multivariate analysis showed that the tumor diameter (P = 0.017), the distance between the antennas (P = 0.032), and the total emission time (P = 0.015) were associated with LTP. CONCLUSIONS: There were trends with lower LTP and improved OS in group B, despite the lack of statistically significant differences between the two strategies at a level of P < 0.05. The increase of distance between antennas and total emission time will facilitate reductions in LTP rate.


Assuntos
Carcinoma Hepatocelular/cirurgia , Ablação por Cateter/instrumentação , Neoplasias Hepáticas/cirurgia , Micro-Ondas/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/mortalidade , Progressão da Doença , Feminino , Humanos , Neoplasias Hepáticas/mortalidade , Masculino , Pessoa de Meia-Idade , Taxa de Sobrevida , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA