Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Clin Med ; 12(6)2023 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-36983397

RESUMO

BACKGROUND: Bicuspid aortic valve (BAV) affects approximately 1.5% of the general population and is seen in nearly 50% of candidates for aortic valve replacement (AVR). Despite increasingly utilised transcatheter aortic valve implantation (TAVI) in aortic stenosis (AS) patients, its use among patients with severe bicuspid AS is limited as BAV is a heterogeneous disease associated with multiple and complex anatomical challenges. AIM: To investigate the one-year outcomes of TAVI using the balloon-expandable Myval transcatheter heart valve (THV) (Meril Life Sciences Pvt. Ltd., Vapi, India) in patients with severe bicuspid AS. METHODS AND RESULTS: We collected data from consecutive patients with bicuspid AS who underwent TAVI with the Myval THV and had at least one-year follow-up. Baseline characteristics, procedural, and 30-day echocardiographic and clinical outcomes were collected. Sixty-two patients were included in the study. The median age was 72 [66.3, 77.0] years, 45 (72.6%) were males, and the mean STS PROM score was 3.2 ± 2.2%. All TAVI procedures were performed via the transfemoral route. The median follow-up duration was 13.5 [12.2, 18.3] months; all-cause mortality was reported in 7 (11.3%) patients and cardiovascular hospitalisation in 6 (10.6%) patients. All-stroke was reported in 2 (3.2%), permanent pacemaker implantation 5 (8.3%), and myocardial infarction 1 (1.6%) patients. The echocardiographic assessment revealed a mean pressure gradient of 10 [8, 16.5] mmHg, effective orifice area 1.7 [1.4, 1.9] cm2, moderate AR in 1 (2%), mild AR in 14 (27%), and none/trace AR in 37 (71%). In total, 1 patient was diagnosed with valve thrombosis (2.1%), Stage II (moderate) haemodynamic deterioration was seen in 3 (6.4%), and stage III (severe) haemodynamic deterioration in 1 (2.1%) patient. CONCLUSIONS: TAVI with the Myval THV in selected BAV anatomy is associated with favourable one-year hemodynamic and clinical outcomes.

2.
Europace ; 10(12): 1428-33, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18936042

RESUMO

AIMS: The aim was to study the common mapping methods for Mahaim fibre and their role in radiofrequency (RF) ablation. METHODS AND RESULTS: Fifteen patients having Mahaim fibre tachycardia underwent electrophysiological study. Mahaim fibre mapping methods like (i) Mahaim potential (M), (ii) shortest atrial stimulus-to-pre-excitation (STP), and (iii) mechanical trauma induced loss of conduction were studied. Accessory pathway mapping was performed by M potential in 10 patients (67%), shortest atrial STP in 3 patients (20%), and mechanical trauma in 2 patients (13%). Mahaim fibre was localized at right atrial freewall of tricuspid annulus (8-10 o'clock) in 13 patients (87%), at 6.30 o'clock in one patient, and at 5 o'clock in 1 patient. Fourteen patients underwent RF ablation. Thirteen patients had complete loss of conduction over accessory pathway and one had partial modification with a conduction delay. Radiofrequency ablation was not performed in one patient (shortest STP group) due to its closeness to the compact atrioventricular node. Mahaim junctional acceleration during RF ablation was observed in all patients of M potential, 1 patient of mechanical trauma, and none of the atrial STP group. One patient (M potential group) had tachycardia recurrence during follow-up. CONCLUSION: Mahaim fibre is commonly located between 8 and 10 o'clock at tricuspid annulus. M potential guides to successful RF ablation in most patients. Mahaim junctional acceleration is commonly seen during RF ablation guided by M potential map.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Pré-Excitação Tipo Mahaim/diagnóstico , Pré-Excitação Tipo Mahaim/cirurgia , Valva Tricúspide/cirurgia , Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Resultado do Tratamento , Adulto Jovem
3.
Eur J Echocardiogr ; 9(5): 599-604, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18296411

RESUMO

AIMS: TTK Chitra heart valve prosthesis (CHVP), a tilting disc mechanical heart valve of low cost and proven efficacy, has been in use for the last 15 years. Although various studies substantiating its long-term safety and efficacy are available, no study had assessed its echocardiographic characteristics. The purpose of this study was to determine the normal Doppler parameters of CHVP in the mitral position and to assess whether derivation of mitral valve area (MVA) using the continuity equation (CE) and more commonly used pressure half-time (PHT) method is comparable in the functional assessment of this tilting disc mitral prosthesis. METHODS AND RESULTS: Doppler echocardiography was performed in 40 consecutive patients with CHVP in the mitral position. All patients were clinically stable, without evidence of prosthetic valve dysfunction such as significant obstruction or regurgitation, endocarditis, left ventricular dysfunction (ejection fraction <40%), or significant aortic regurgitation. Valve sizes studied included 25, 27, and 29 mm. Mitral valve area was derived both by the PHT method and by the CE, using the stroke volume measured in the ventricular outflow tract divided by the time-velocity integral of CHVP jet. The peak Doppler gradient ranged from 5 to 21 (mean 11.0) mmHg, and the mean gradient ranged from 1.7 to 9.2 (mean 4.1) mmHg. Mean gradient negatively correlated with an increase in the actual orifice area (AOA) derived from the valve orifice diameter given by the manufacturer (r = -0.45, P = 0.004). Mitral valve area calculated by both PHT and CE increased significantly with an increase in the AOA (r = 0.42, P = 0.007 and r = 0.32, P = 0.046, respectively). Mitral valve area by the CE averaged 1.55 +/- 0.36 cm(2) (range 0.85 cm(2) for a 25 mm valve to 2.41 cm(2) for a 29 mm valve) and was smaller than by PHT (mean 2.04 +/- 0.41 cm(2), range 1.40-3.14 cm(2); P = 0.0001; t-test), irrespective of whether PHT is less than or >110 ms. CONCLUSION: The Doppler parameters obtained with CHVP in the mitral position are comparable with those obtained with the different prosthetic valves in common use. In the selected group of patients with CHVP, assessment of MVA by the PHT method is comparable with that by the CE. Areas by both methods were smaller than the AOA provided by the manufacturer, as seen in other similar design valves.


Assuntos
Ligas Dentárias , Ecocardiografia Doppler , Próteses Valvulares Cardíacas , Valva Mitral/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Valva Mitral/patologia , Volume Sistólico
4.
J Interv Card Electrophysiol ; 21(3): 215-8, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18246417

RESUMO

A 42-year-old male had history of recurrent palpitation and was documented to have wide QRS tachycardia. Magnetic resonance imaging angiogram showed evidence of arrhythmogenic right ventricular dysplasia and severe right ventricular dysfunction. Electrophysiology study showed evidence of bundle branch reentry ventricular tachycardia. It was successfully treated by radiofrequency ablation of right bundle branch. This is probably the first case of bundle branch reentry as a mechanism for ventricular tachycardia in a case of arrhythmogenic right ventricular dysplasia.


Assuntos
Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/cirurgia , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/cirurgia , Ablação por Cateter , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Adulto , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Eletrocardiografia , Humanos , Angiografia por Ressonância Magnética , Masculino , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia
5.
J Ovarian Res ; 10(1): 55, 2017 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-28806987

RESUMO

BACKGROUND: There is no universal screening method for discrimination between benign and malignant adnexal masses yet. Various authors have tried tumor markers, imaging studies, cytology but no one yet is a definite method for screening of cancer ovary, for which a combined diagnostic modality has come to practice in form of RMI. With this background we conducted our study "Evaluation of risk malignancy index and its diagnostic value in patients with adnexal masses". METHODS: The aim of the study was to determine the effectiveness of risk of malignancy index (RMI-3) in preoperative discrimination between benign and malignant masses and also to reveal the most suitable cut off value. We have conducted a prospective study between November 2014 to October 2016. We included the parameters like menopausal status, ultrasound features, and serum levels of tumor marker like CA-125 for calculating RMI 3. Then RMI was compared with the histopathological report which was taken as gold standard. RESULTS: In the present study malignant tumors constitute 54.76% (69/126) & benign tumors 45.24% (57/126). Bilaterality in adnexal masses and multilocularity is higher in malignant tumors than benign tumor, but a P -value >0.005 failed to be proved significant in our study. Solid area is seen in 24.69% (20/81) of benign and 75.30% (61/81) of malignant tumor. Similarly ascites was found in 38.09% (48/126) of cases. Out of which 18.75% (9/48) cases were found to be benign and malignancy was confirmed in 81.25% (39/48) patients. There is statistically significant number of malignant ovarian cancer patients where ascites and solid area is seen in USG findings (p = 0.000). Risk of Malignancy Index compared with individual parameters of Ultrasound score, CA-125 or menopausal score and a cut-off point of 236 shows a very high sensitivity (72.5%), specificity (98.2%), positive predictive value (98.1%), negative predictive value (74.7%) and diagnostic accuracy (84.13%) for discriminating malignant and benign pelvic masses. CONCLUSION: Simplicity and applicability of the method in the primary evaluation of patients with pelvic masses makes it a good option in daily clinical practice in non-specialized gynecologic departments and also in developing countries where access to a gynaecologist oncologist is limited.


Assuntos
Neoplasias Ovarianas/diagnóstico , Ovário/patologia , Adulto , Antígeno Ca-125/sangue , Feminino , Humanos , Menopausa , Pessoa de Meia-Idade , Neoplasias Ovarianas/sangue , Neoplasias Ovarianas/patologia , Risco , Ultrassonografia , Adulto Jovem
6.
Indian Heart J ; 56(2): 150-1, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15377139

RESUMO

Negotiating the pacing lead into the right ventricle via left superior vena cava, at times, can be difficult. We report two such cases in which pacing leads were introduced into the right ventricle via left superior vena cava, with the help of stylet tip shaped into a large pigtail loop.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Flutter Atrial/diagnóstico , Flutter Atrial/terapia , Estimulação Cardíaca Artificial/métodos , Idoso , Idoso de 80 Anos ou mais , Angiografia/métodos , Desfibriladores Implantáveis , Ecocardiografia Doppler , Eletrocardiografia , Feminino , Seguimentos , Átrios do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista , Medição de Risco , Índice de Gravidade de Doença , Resultado do Tratamento , Veia Cava Superior
7.
Indian Heart J ; 55(6): 637-40, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14989516

RESUMO

BACKGROUND: Subclavian vein puncture is commonly performed to insert the pacing lead for permanent pacemaker implantation. Our aim was to study the safety and feasibility of venogram-guided extrathoracic subclavian vein puncture for permanent pacemaker lead insertion. METHODS AND RESULTS: Sixty patients (32 males, and 28 females) underwent permanent pacemaker lead insertion by extrathoracic subclavian vein puncture at our institute between March 2002 and December 2002. Fifteen patients underwent dual-chamber and 45 single-chamber pacemaker implantation. All the patients underwent extrathoracic subclavian vein puncture guided by venogram, except 1 who underwent dual-chamber pacemaker implantation in whom the ventricular lead insertion was via the cephalic vein on an elective basis. The procedure was successful in all the patients. Inadvertent subclavian artery puncture occurred in 2 patients without any complication. There was no incidence of pneumothorax, hemothorax or pacemaker site infection. CONCLUSIONS: Venogram-guided extrathoracic subclavian vein puncture is safe and successful. It may be adopted as one of the preferred approaches for permanent pacemaker lead insertion.


Assuntos
Marca-Passo Artificial , Flebografia/métodos , Flebotomia/métodos , Implantação de Prótese/métodos , Veia Subclávia/cirurgia , Adolescente , Adulto , Idoso , Criança , Meios de Contraste , Eletrodos Implantados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Flebografia/instrumentação , Flebotomia/instrumentação , Estudos Prospectivos , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Veia Subclávia/diagnóstico por imagem
9.
Europace ; 8(2): 140-3, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16627427

RESUMO

In a 12-year-old girl with history of recurrent palpitation, an ambulatory 24 h Holter electrocardiogram showed a wide QRS complex rhythm with atrioventricular dissociation. During an electrophysiology study, an atriofascicular pathway was diagnosed with an inducible antidromic atrioventricular re-entrant tachycardia. At slower heart rates, the patient had a wide QRS complex escape rhythm similar to the tachycardia and the pre-excited QRS complex morphology. This indicates the presence of pacemaker-like cells in the atriofascicular accessory pathway giving rise to the wide QRS complex escape rhythm at a slower heart rate.


Assuntos
Bloqueio de Ramo/complicações , Bloqueio de Ramo/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/complicações , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Bloqueio de Ramo/cirurgia , Ablação por Cateter , Criança , Eletrocardiografia Ambulatorial , Feminino , Frequência Cardíaca/fisiologia , Humanos , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA