Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Chin J Traumatol ; 26(3): 183-186, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36641320

RESUMO

For the treatment of an intertrochanteric fracture combined with femoral head necrosis in middle-age patients, it has been controversial whether to perform fracture reduction and fixation first then total hip replacement, or direct total hip replacement. We present a rare case of 53-year-old male patient suffered from bilateral intertrochanteric fracture caused by a road traffic injury. The patient had a history of femoral head necrosis for eight years, and the Harris score was 30. We performed total hip replacement with prolonged biologic shank prostheses for primary repair. One year after the surgery, nearly full range of motion was achieved without instability (active flexion angle of 110°, extension angle of 20°, adduction angle of 40°, abduction angle of 40°, internal rotation angle of 25°, and external rotation angle of 40°). The Harris score was 85. For the middle-aged patient with unstable intertrochanteric fractures and osteonecrosis of the femoral head, we can choose primary repair for concurrent bilateral intertrochanteric fracture and femoral head necrosis with prolonged shank biologic total hip replacement.


Assuntos
Artroplastia de Quadril , Produtos Biológicos , Necrose da Cabeça do Fêmur , Fraturas do Quadril , Masculino , Pessoa de Meia-Idade , Humanos , Artroplastia de Quadril/métodos , Cabeça do Fêmur/cirurgia , Necrose da Cabeça do Fêmur/etiologia , Necrose da Cabeça do Fêmur/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas do Quadril/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
2.
J Orthop Surg Res ; 14(1): 223, 2019 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-31319875

RESUMO

BACKGROUND: The accelerometer-based navigation (ABN) system is an emerging navigation system for total knee arthroplasty (TKA). This study aimed to determine whether the ABN system could improve the accuracy of mechanical alignment, component positioning, and short-term clinical outcomes for TKA when compared to conventional instruments (CON). METHODS: A total of 204 patients were selected and divided into two groups (CON: 135, ABN: 69) after applying the inclusion and exclusion criteria. Then, 1:1 propensity score matching was performed for age, gender, body mass index, hip-knee-ankle angle (HKA), Knee Society Score (KSS), Western Ontario and McMaster Universities (WOMAC) score, and follow-up times. A total of 82 consecutive patients (82 knees) underwent total knee arthroplasty using ABN (n = 41) or CON (n = 41) were enrolled in this study. The postoperative HKA, frontal femoral component (FFC) angle, frontal tibial component (FTC) angle, lateral femoral flexion (LFF) angle, and lateral tibial component (LTC) angle were compared between the two groups to evaluate mechanical alignment and component positioning. Additional clinical parameters, including haemoglobin reduction, the KSS, and the WOMAC score, were assessed at the final follow-up (the mean follow-up period was 20.9 months in the CON group and 21.2 months in the ABN group). RESULTS: The ABN group had a significantly improved mean absolute deviation of HKA (P = 0.033), FFC (P = 0.004), FTC (P = 0.017), LFF (P = 0.023), and LTC (P = 0.031) compared to those of the CON group. The numbers of FFCs and LTCs within 3° were significantly different (P = 0.021, P = 0.023, respectively) between the two groups. However, no differences in the numbers of FTCs within 3° (P = 0.166) and LFF within 3° (P = 0.556) were found. The ABN group had a significantly higher KS function score (P = 0.032), and the pain and stiffness scores were significantly different (P = 0.034, P = 0.020, respectively) between the two groups. Moreover, the ABN system could reduce hidden blood loss postoperatively. However, no difference was found in the KS knee score and the total WOMAC score between the two groups. CONCLUSION: This study demonstrates that ABN system improved TKA mechanical alignment and component positioning and decreased the hidden blood loss postoperatively compared to conventional instruments. However, no significant differences were found in short-term clinical outcomes between ABN and conventional instruments at the final follow-up. However, whether this system contributes to revision rates and long-term clinical outcomes requires further study.


Assuntos
Acelerometria/métodos , Artroplastia do Joelho/métodos , Pontuação de Propensão , Navegação Espacial , Acelerometria/normas , Idoso , Artroplastia do Joelho/normas , Estudos de Casos e Controles , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA