1.
Electrophoresis ; 41(7-8): 481-492, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31598992

RESUMO

Peak shapes in electrophoresis are often distorted from the ideal Gaussian shape due to disturbing phenomena, of which the most important is electromigration dispersion. For fully dissociated analytes, there is a tight analogy between nonlinear models describing a separation process in chromatography and electrophoresis. When the velocity of the separated analyte depends on the concentration of the co-analyte, the consequence is a mutual influence of the analytes couples, which distorts both analyte zones. In this paper, we introduce a nonlinear model of electromigration for the analysis of two co-migrating fully dissociated analytes. In the initial stages of separation, they influence each other, which causes much more complicated peak shapes. The analysis has revealed that the two most important phenomena-the displacement and the tag-along effects-are common both for nonlinear chromatography and electrophoresis, though their description is partly based on rather different phenomena. The comparison between the nonlinear model of electromigration we describe and the numerical computer solution of the original continuity equations has proven an almost perfect agreement. The predicted features in peak shapes in initial stages of separation have been fully confirmed by the experiments.


Assuntos
Cromatografia , Eletroforese Capilar , Dinâmica não Linear , Modelos Químicos
2.
Electrophoresis ; 41(7-8): 493-501, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31651992

RESUMO

Thermodynamic acidity constants (acid or acid-base dissociation constants, sometimes called also as ionization constants) and limiting ionic mobilities (both of them at defined temperature, usually 25°C) are the fundamental physicochemical characteristics of a weak electrolyte, that is, weak acid or weak base or ampholyte. We introduce a novel method for determining the data of a weak electrolyte by the nonlinear regression of effective electrophoretic mobility versus buffer composition dependence when measured in a set of BGEs with various pH. To correct the experimental data for zero ionic strength we use the extended Debye-Hückel model and Onsager-Fuoss law with no simplifications. Contrary to contemporary approaches, the nonlinear regression is performed on limiting mobility data calculated by PeakMaster's correction engine, not on the raw experimental mobility data. Therefore, there is no requirement to perform all measurements at a constant ionic strength of the set of BGEs. We devised the computer program AnglerFish that performs the necessary calculations in a user-friendly fashion. All thermodynamic pKa values and limiting electrophoretic mobilities for arbitrarily charged substances having any number of ionic forms are calculated by one fit. The user input consists of the buffer composition of the set of BGEs and experimentally measured effective mobilities of the inspected weak electrolyte.


Assuntos
Eletrólitos/química , Eletroforese Capilar/métodos , Software , Algoritmos , Eletrólitos/análise , Concentração de Íons de Hidrogênio , Dinâmica não Linear , Concentração Osmolar , Termodinâmica
3.
Electrophoresis ; 40(5): 668-682, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30478971

RESUMO

The continuity equations that describe the movement of ions in liquid solutions under the influence of an external stationary electric field, as it is utilized in electrophoresis, were introduced a long time ago starting with Kohlrausch in 1897. From that time on, there have been many attempts to solve the equations and to discuss the results. In electrophoresis, special attention has always been devoted to the peak shapes obtained by the detector since the shapes have a tight connection with the phenomena taking place during electromigration and influence the efficiency and selectivity of the separation. Among these phenomena, the most important is electromigration dispersion. In this commented review paper, we compare various models of electromigration, try to find points that connect them, and discuss the range of their validity in light of the linear and nonlinear theory of electromigration.


Assuntos
Eletroforese Capilar , Modelos Químicos , Íons/análise , Íons/química , Íons/isolamento & purificação , Modelos Estatísticos
4.
Electrophoresis ; 40(21): 2810-2819, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31429941

RESUMO

A simple, sensitive, specific, and cost-effective analytical methodology was developed for the analysis of human plasma samples spiked with imatinib by CZE with on-line UV detection in the context of Therapeutic Drug Monitoring. Several analytical conditions such as the ionic strength (I) and the pH of the BGE composed of citric acid and ε-amino caproic acid were studied in regards of the presence of sodium chloride (NaCl) in plasma samples (1% m/v). Computer simulations (Simul software) were used to confirm the experimental results and to understand imatinib electrophoretic behavior in the presence of NaCl. Furthermore, the advantages of adding ACN to the sample containing NaCl to combine efficient protein precipitation and on-line CZE stacking of imatinib were demonstrated. LOD and LOQ values of 48 and 191 ng/mL were obtained from plasma sample supernatant after protein precipitation with ACN, which is much lower than mean imatinib plasma level observed for patients treated by imatinib mesylate (about 1000 ng/mL). Good linearity was obtained in the concentration range 191-5000 ng/mL (R2  > 0.997). RSD of less than 1.68% and 2.60% (n = 6) for migration times and corrected peak areas, respectively, were observed at the LOQ.


Assuntos
Acetonitrilas/química , Eletroforese Capilar/métodos , Mesilato de Imatinib/sangue , Cloreto de Sódio/química , Humanos , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes , Software
5.
Electrophoresis ; 40(5): 756-765, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30548637

RESUMO

Point-of-care systems based on microchip capillary electrophoresis require single-use, disposable microchips prefilled with all necessary solutions so an untrained operator only needs to apply the sample and perform the analysis. While microchip fabrication can be (and has been) standardized, some manufacturing differences between microchips are unavoidable. To improve analyte precision without increasing device costs or introducing additional error sources, we recently proposed the use of integrated internal standards (ISTDs): ions added to the BGE in small concentrations which form system peaks in the electropherogram that can be used as a measurement reference. Here, we further expand this initial proof-of-principle test to study a clinically-relevant application of K ion concentrations in human blood; however, using a mock blood solution instead of real samples to avoid interference from other obstacles (e.g. cell lysis). Cs as an integrated ISTD improves repeatability of K ion migration times from 6.97% to 0.89% and the linear calibration correlation coefficient (R2 ) for K quantification from 0.851 to 0.967. Peak area repeatability improves from 11.6-13.3% to 4.75-5.04% at each K concentration above the LOQ. These results further validate the feasibility of using integrated ISTDs to improve imprecision in disposable microchip CE devices by demonstrating their application for physiological samples.


Assuntos
Eletroforese Capilar/instrumentação , Eletroforese Capilar/métodos , Dispositivos Lab-On-A-Chip , Humanos , Modelos Biológicos , Potássio/sangue , Padrões de Referência , Reprodutibilidade dos Testes
6.
Electrophoresis ; 40(21): 2799-2805, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31281995

RESUMO

Novel capillary electrophoresis methods using CDs as chiral selectors were developed and validated for the chiral separation of lansoprazole and rabeprazole, two proton pump inhibitors. Fourteen different neutral and anionic CDs were screened at pH 4 and 7 in the preliminary analysis. Sulfobutyl-ether-ß-CD with a degree of substitution of 6.5 and 10 at neutral pH proved to be the most suitable chiral selector for both compounds. Various dual CD systems were also compared, and the possible mechanisms of enantiomer separation were investigated. A dual selector system containing sulfobutyl-ether-ß-CD degree of substitution 6.5 and native γ-CD proved to be the most adequate system for the separations. Method optimization was carried out using an experimental design approach, performing an initial fractional factorial screening design, followed by a central composite design to establish the optimal analytical conditions. The optimized methods (25 mM phosphate buffer, pH 7, 10 mM sulfobutyl-ether-ß-CD/20 mM γ-CD, +20 kV voltage; 17°C temperature; 50 mbar/3 s injection, detection at 210 nm for lansoprazole; 25 mM phosphate buffer, pH 7, 15 mM sulfobutyl-ether-ß-CD/30 mM γ-CD, +20 kV voltage; 18°C temperature; 50 mbar/3 s injection, detection at 210 nm for rabeprazole) provided baseline separation for lansoprazole (Rs = 2.91) and rabeprazole (Rs = 2.53) enantiomers with favorable migration order (in both cases the S-enantiomers migrates first). The optimized methods were validated according to current guidelines and proved to be reliable, linear, precise, and accurate for the determination of 0.15% distomer as chiral impurity in dexlansoprazole and dexrabeprazole samples.


Assuntos
Ciclodextrinas/química , Eletroforese Capilar/métodos , Lansoprazol/análise , Rabeprazol/análise , Lansoprazol/química , Lansoprazol/isolamento & purificação , Limite de Detecção , Modelos Lineares , Rabeprazol/química , Rabeprazol/isolamento & purificação , Reprodutibilidade dos Testes , Estereoisomerismo
7.
Electrophoresis ; 40(5): 683-692, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30548631

RESUMO

The linear theory of electromigration, including the first-order nonlinear approximation, is generalized to systems with any equilibria fast enough to be considered instantaneous in comparison with the timescale of peak movement. For example, this theory is practically applied in the electrokinetic chromatography (EKC) mode of the CZE. The model enables the calculation of positions and shapes of analyte and system peaks without restricting the number of selectors, the complexation stoichiometry, or simultaneous acid-base equilibria. The latest version of our PeakMaster software, PeakMaster 6-Next Generation, implements the theory in a user-friendly way. It is a free and open-source software that performs all calculations and shows the properties of the background electrolyte and the expected electropherogram within a few seconds. In this paper, we mathematically derive the model, discuss its applicability to EKC systems, and introduce the PeakMaster 6 software.


Assuntos
Eletroforese Capilar/métodos , Software , Eletrocromatografia Capilar/métodos , Eletrólitos/química , Íons/química , Modelos Lineares , Modelos Químicos
8.
Electrophoresis ; 39(5-6): 742-751, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29193171

RESUMO

The partial-filling affinity capillary electrophoresis (pf-ACE) works with a ligand present in a background electrolyte that forms a weak complex with an analyte. In contrast to a more popular mobility-shift affinity capillary electrophoresis, only a short plug of the ligand is introduced into a capillary in the pf-ACE. Both methods can serve for determining apparent stability constants of the formed complexes but this task is hindered in the pf-ACE by the fact that the analyte spends only a part of its migration time in a contact with the ligand. In 1998, Amini and Westerlund published a linearization strategy that allows for extracting an effective mobility of an analyte in the presence of a neutral ligand out of the pf-ACE data. The main purpose of this paper is to show that the original formula is only approximate. We derive a new formula and demonstrate its applicability by means of computer simulations. We further inspect several strategies of data processing in the pf-ACE regarding a risk of an error propagation. This establishes a good practice of determining apparent stability constants of analyte-ligand complexes by means of the pf-ACE.


Assuntos
Fenômenos Bioquímicos , Simulação por Computador , Eletroforese Capilar/métodos , Eletrólitos/química , Ligantes , Regressão Psicológica , Termodinâmica
9.
Electrophoresis ; 39(11): 1390-1398, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29451297

RESUMO

Conductivity detection is a universal detection technique often encountered in electrophoretic separation systems, especially in modern chip-electrophoresis based devices. On the other hand, it is sparsely combined with another contemporary trend of enhancing limits of detection by means of various preconcentration strategies. This can be attributed to the fact that a preconcentration experimental setup usually brings about disturbances in a conductivity baseline. Sweeping with a neutral sweeping agent seems a good candidate for overcoming this problem. A neutral sweeping agent does not hinder the conductivity detection while a charged analyte may preconcentrate on its boundary due to a decrease in its effective mobility. This study investigates such sweeping systems theoretically, by means of computer simulations, and experimentally. A formula is provided for the reliable estimation of the preconcentration factor. Additionally, it is demonstrated that the conductivity signal can significantly benefit from slowing down the analyte and thus the overall signal enhancement can easily overweight amplification caused solely by the sweeping process. The overall enhancement factor can be deduced a priori from the linearized theory of electrophoresis implemented in the PeakMaster freeware. Sweeping by neutral cyclodextrin is demonstrated on an amplification of a conductivity signal of flurbiprofen in a real drug sample. Finally, a possible formation of unexpected system peaks in systems with a neutral sweeping agent is revealed by the computer simulation and confirmed experimentally.


Assuntos
Ciclodextrinas/química , Condutividade Elétrica , Eletroforese Capilar/métodos , Analgésicos , Simulação por Computador , Flurbiprofeno/química , Limite de Detecção
10.
Anal Chem ; 89(5): 2886-2892, 2017 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-28192985

RESUMO

To improve point-of-care quantification using microchip capillary electrophoresis (MCE), the chip-to-chip variabilities inherent in disposable, single-use devices must be addressed. This work proposes to integrate an internal standard (ISTD) into the microchip by adding it to the background electrolyte (BGE) instead of the sample-thus eliminating the need for additional sample manipulation, microchip redesigns, and/or system expansions required for traditional ISTD usage. Cs and Li ions were added as integrated ISTDs to the BGE, and their effects on the reproducibility of Na quantification were explored. Results were then compared to the conclusions of our previous publication which used Cs and Li as traditional ISTDs. The in-house fabricated microchips, electrophoretic protocols, and solution matrixes were kept constant, allowing the proposed method to be reliably compared to the traditional method. Using the integrated ISTDs, both Cs and Li improved the Na peak area reproducibility approximately 2-fold, to final RSD values of 2.2-4.7% (n = 900). In contrast (to previous work), Cs as a traditional ISTD resulted in final RSDs of 2.5-8.8%, while the traditional Li ISTD performed poorly with RSDs of 6.3-14.2%. These findings suggest integrated ISTDs are a viable method to improve the precision of disposable MCE devices-giving matched or superior results to the traditional method in this study while neither increasing system cost nor complexity.

11.
Anal Bioanal Chem ; 408(30): 8623-8641, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27558099

RESUMO

We focus on the state-of-the-art theory of electromigration under single and multiple complexation equilibrium. Only 1:1 complexation stoichiometry is discussed because of its unique status in the field of affinity capillary electrophoresis (ACE). First, we summarize the formulas for the effective mobility in various ACE systems as they appeared since the pioneering days in 1992 up to the most recent theories till 2015. Disturbing phenomena that do not alter the mobility of the analyte directly but cause an unexpected peak broadening have been studied only recently and are also discussed in this paper. Second, we turn our attention to the viscosity effects in ACE. Change in the background electrolyte viscosity is unavoidable in ACE but numerous observations scattered throughout the literature have not been reviewed previously. This leads to an uncritical employment of correction factors that may or may not be appropriate in practice. Finally, we consider the ionic strength effects in ACE, too. Limitations of the current theories are also discussed and the tasks identified where open problems still prevail. Graphical Abstract A weak base (A) undergoes an acidic-basic equilibria (in blue) and migrates with an electrophoretic mobility of [Formula: see text]. Simultaneously, it interacts with a selector (sel) while the analyte-selector complex migrates with an electrophoretic mobility of [Formula: see text]. The strength of the interaction (in orange) is governed by the binding constant, K A , and the concentration of the selector, c sel . This all gives the analyte an effective mobility of [Formula: see text] and moves it out of the zero position (EOF; right top insert). The interaction of the positively charged analyte with the neutral selector slows down the analyte with increasing selector concentration (right bottom insert).

12.
Electrophoresis ; 36(5): 655-61, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25475400

RESUMO

For Gaussian peaks, the migration time of the analyte results as the position of the top of the peak and the zone variance is proportional to the peak width. Similar relations have not yet been derived for the Haarhoff-van der Linde (HVL) function, which appears as a fundamental peak-shape function in electrophoresis. We derive the relations between the geometrical measures of the HVL-shaped peak, that is the position of its maximum, its width and a measure of its asymmetry, and the respective parameters a1, a2, and a3, of the corresponding HVL function. Under the condition of the HVL-shaped peak, the a1 parameter reflects the true migration time of the analyte, which may differ from the peak top position significantly. Our procedure allows us to express the parameters without the need of any external data processing (nonlinear regression). We demonstrate our approach on simulated peaks and on experimental data integrated by the ChemStation software (delivered with the CE instrumentation by Agilent Technologies). A significant improvement is achieved reading the migration time of the experimental and simulated peaks, which draws the error of the HVL-shaped peak migration time evaluation down to the resolution of the data sampling rate.


Assuntos
Eletroforese/métodos , Modelos Teóricos , Simulação por Computador , Software , Fatores de Tempo
13.
Electrophoresis ; 36(5): 646-54, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25503084

RESUMO

Although the classical formula of peak resolution was derived to characterize the extent of separation only for Gaussian peaks of equal areas, it is often used even when the peaks follow non-Gaussian distributions and/or have unequal areas. This practice can result in misleading information about the extent of separation in terms of the severity of peak overlap. We propose here the use of the equivalent peak resolution value, a term based on relative peak overlap, to characterize the extent of separation that had been achieved. The definition of equivalent peak resolution is not constrained either by the form(s) of the concentration distribution function(s) of the peaks (Gaussian or non-Gaussian) or the relative area of the peaks. The equivalent peak resolution value and the classically defined peak resolution value are numerically identical when the separated peaks are Gaussian and have identical areas and SDs. Using our new freeware program, Resolution Analyzer, one can calculate both the classically defined and the equivalent peak resolution values. With the help of this tool, we demonstrate here that the classical peak resolution values mischaracterize the extent of peak overlap even when the peaks are Gaussian but have different areas. We show that under ideal conditions of the separation process, the relative peak overlap value is easily accessible by fitting the overall peak profile as the sum of two Gaussian functions. The applicability of the new approach is demonstrated on real separations.


Assuntos
Eletroforese Capilar/métodos , Distribuição Normal , Reprodutibilidade dos Testes , Software
14.
Electrophoresis ; 36(5): 712-21, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25545697

RESUMO

This paper reports on recent research creating a family of electrophoresis-based point of care devices for the determination of a wide range of ionic analytes in various sample matrices. These devices are based on a first version for the point-of-care measurement of Li(+), reported in 2010 by Floris et al. (Lab Chip 2010, 10, 1799-1806). With respect to this device, significant improvements in accuracy, precision, detection limit, and reliability have been obtained especially by the use of multiple injections of one sample on a single chip and integrated data analysis. Internal and external validation by clinical laboratories for the determination of analytes in real patients by a self-test is reported. For Li(+) in blood better precision than the standard clinical determination for Li(+) was achieved. For Na(+) in human urine the method was found to be within the clinical acceptability limits. In a veterinary application, Ca(2+) and Mg(2+) were determined in bovine blood by means of the same chip, but using a different platform. Finally, promising preliminary results are reported with the Medimate platform for the determination of creatinine in whole blood and quantification of both cations and anions through replicate measurements on the same sample with the same chip.


Assuntos
Análise Química do Sangue/instrumentação , Eletrólitos/sangue , Eletroforese/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Animais , Cálcio/sangue , Bovinos , Desenho de Equipamento , Humanos , Lítio/sangue , Magnésio/sangue , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Electrophoresis ; 35(19): 2688-700, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24946108

RESUMO

It has been 20 years since Lurie et al. first published their model of electromigration of an analyte under simultaneous interaction with two cyclodextrins as chiral selectors. Since then, the theory of (enantio)separation in dual and complex mixtures of (chiral) selectors is well understood. In spite of this, a trial-and-error approach still prevails in analytical practice. Such a situation is likely caused by the fact that the entire theory is spread over numerous papers and the relations between various models are not always clear. The present review condenses the theory for the first time. Available mathematical models and feasible practical approaches are summarized and their advantages and limitations discussed.


Assuntos
Eletroforese Capilar , Cromatografia Capilar Eletrocinética Micelar , Ciclodextrinas , Eletroforese Capilar/instrumentação , Eletroforese Capilar/métodos , Estereoisomerismo
16.
Anal Chem ; 85(18): 8526-34, 2013 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-23895553

RESUMO

This article elucidates the practical impact of the complexation of buffer constituents with complexation agents on electrophoretic results, namely, complexation constant determination, system peak development, and proper separation of analytes. Several common buffers, which were selected based on the pH study in Part I of this paper series (Riesová, M.; Svobodová, J.; Tosner, Z.; Benes, M.; Tesarová, E.; Gas, B. Anal. Chem., 2013, DOI: 10.1021/ac4013804); e.g., CHES, MES, MOPS, Tricine were used to demonstrate behavior of such complex separation systems. We show that the value of a complexation constant determined in the interacting buffers environment depends not only on the analyte and complexation agent but it is also substantially affected by the type and concentration of buffer constituents. As a result, the complexation parameters determined in the interacting buffers cannot be regarded as thermodynamic ones and may provide misleading information about the strength of complexation of the compound of interest. We also demonstrate that the development of system peaks in interacting buffer systems significantly differs from the behavior known for noncomplexing systems, as the mobility of system peaks depends on the concentration and type of neutral complexation agent. Finally, we show that the use of interacting buffers can totally ruin the results of electrophoretic separation because the buffer properties change as the consequence of the buffer constituents' complexation. As a general conclusion, the interaction of buffer constituents with the complexation agent should always be considered in any method development procedures.

17.
Electrophoresis ; 34(5): 768-76, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23192321

RESUMO

A neutral marker of the EOF can gain a nonzero effective mobility because of its possible interaction with a charged complexing agent, such as a chiral selector in CE. We determined effective mobilities of four compounds often used as EOF markers (dimethyl sulfoxide, mesityl oxide, nitromethane, and thiourea) in the BGE-containing sulfated ß-CD (60 g/L). All the compounds studied were measurably mobilized by their interaction with the selector. The highest effective mobility (-3.0·10(-9) m(2) s(-1) V(-1)) was observed for thiourea and the lowest (-1.5·10(-9) m(2) s(-1) V(-1)) for dimethyl sulfoxide and nitromethane. The mobilities were determined by a new two-detector pressure mobilization method (2d method), which we propose, and the results were confirmed by standard CE measurements. In the 2d method, one marker zone is situated in the BGE containing the charged selector, while the second marker zone is surrounded with a selector-free BGE, which prevents its complexation. The initial distance between the two marker zones equals the capillary length from the inlet to the first detector. After a brief voltage application, the final distance between the marker zones is determined based on known capillary length from the first to the second detector. The difference between these two distances determines the effective mobility.


Assuntos
Eletro-Osmose/métodos , Eletroforese Capilar/métodos , Modelos Químicos , beta-Ciclodextrinas/química , Acetona/química , Dimetil Sulfóxido/química , Eletrólitos/química , Hexanonas/química , Metano/análogos & derivados , Metano/química , Nitroparafinas/química , Tioureia/química
18.
Electrophoresis ; 33(19-20): 3012-20, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22996563

RESUMO

This paper describes the results of the second-level testing of the simulation program Simul 5 Complex. We compare the published experimental results with the simulated migration behavior of the enantiomers at different pH and chiral selector concentration values and use the same optimization object function, separation selectivity, as the original papers. Simul 5 Complex proved to be a suitable tool for the prediction of the effective mobilities, separation selectivities, and migration order reversals in these pH-dependent and CD concentration dependent enantiomer separations. In addition, by performing simulations of four different separations systems (both real and model systems), Simul 5 Complex revealed the existence of unexpected and hitherto unexplained electromigration dispersion effects that were caused by the complexation process itself and could significantly impair the quality of the separations.


Assuntos
Eletroforese Capilar , Modelos Químicos , Simulação por Computador , Dipeptídeos/química , Dipeptídeos/isolamento & purificação , Eletrólitos , Concentração de Íons de Hidrogênio , Software , Estereoisomerismo , Tropanos/química , Tropanos/isolamento & purificação
19.
Phys Rev Lett ; 108(13): 138101, 2012 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-22540727

RESUMO

In this Letter we provide a theory to show that high-field electrokinetic translocation of DNA through nanopores or nanochannels causes large transient variations of the ionic concentrations in front and at the back of the DNA due to concentration polarization (CP). The CP causes strong local conductivity variations, which can successfully explain the nontrivial current transients and ionic distributions observed in molecular dynamics simulations of nanopore DNA translocations as well as the transient current dips and spikes measured for translocating hairpin DNA. Most importantly, as the future of sequencing of DNA by nanopore translocation will be based on time-varying electrical conductance, CP, must be considered in experimental design and interpretation--currently these studies are mostly based on the incomplete pore conductance models that ignore CP and transients in the electrical conductance.


Assuntos
DNA/química , Modelos Químicos , Nanoporos , Conformação de Ácido Nucleico
20.
Electrophoresis ; 32(5): 595-603, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21290389

RESUMO

The method for determination of rate constants of interconversion of enantiomers in chiral and achiral environments of a dynamic enantioseparation system was investigated in order to reveal its accuracy, sensitivity and robustness. Two significantly different enantioseparation systems were selected, one with a single (well-defined) chiral selector (CS) and the second with a mixture of CSs, and the rate constants of interconversion for these two systems were compared statistically. While the rate constants of interconversion in the chiral environment were found to be significantly different, the rate constants in achiral environment were confirmed to be statistically the same. The accuracy of the method was independent of experimental conditions. Influence of a CS and temperature on the rate of interconversion were discussed within the scope of determined thermodynamic parameters and statistical evaluation. A certain temperature may exist at which two different types of CSs influence the rate of interconversion equally while the extent of their influence may largely differ at other temperatures.


Assuntos
Eletroforese/métodos , Algoritmos , Ciclodextrinas , Cinética , Modelos Lineares , Estereoisomerismo , Temperatura