Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38582974

RESUMO

AIMS: The ultra-low-temperature cryoablation (ULTC) ablation system using -196°C N2 cryogen has been reported to create lesions with freeze duration-dependent depth titratable to over 10 mm with minimum attenuation by scar. Cryocure-VT (NCT04893317) was a first-in-human clinical trial evaluating the safety and efficacy of a novel, purpose-built ULTC catheter in endocardial ablation of scar-dependent ventricular tachycardias (VTs). METHODS AND RESULTS: This prospective, multi-centre study enrolled patients referred for de novo or second ablations of recurrent monomorphic VT of both ischaemic and non-ischaemic aetiologies. Primary safety and efficacy endpoints of the study were freedom from device- or procedure-related major adverse events (MAEs) up to 30 days post-ablation, acute non-inducibility of clinical VTs at the end of the procedure, and freedom from sustained VT or implantable defibrillator intervention at 6 months. Ultra-low-temperature cryoablation was performed in 64 patients (age 67 ± 11 years, 78% ischaemic, ejection fraction = 35 ± 10%) at 9 centres. The primary acute effectiveness endpoint was achieved in 94% (51/54) of patients in whom post-ablation induction was attempted. There were no protocol-defined MAEs; four procedure-related serious adverse events resolved without clinical sequelae. At 6-month follow-up, 38 patients (60.3%) remained VT-free, and freedom from defibrillator shock was 81.0%, with no significant difference between ischaemic and non-ischaemic cohorts. In 47 patients with defibrillator for at least 6 months prior to the ablation, the VT burden was reduced from median of 4, inter-quartile range (IQR, 1-9) to 0, IQR (0-2). CONCLUSION: In this first-in-human multi-centre experience, endocardial ULTC ablation of monomorphic VT appears safe and effective in patients with both ischaemic-cardiomyopathy and non-ischaemic-cardiomyopathy. CLINICAL TRIAL REGISTRATION: NCT04893317.


Assuntos
Cardiomiopatias , Ablação por Cateter , Criocirurgia , Taquicardia Ventricular , Idoso , Humanos , Pessoa de Meia-Idade , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Cardiomiopatias/cirurgia , Ablação por Cateter/efeitos adversos , Cicatriz/complicações , Criocirurgia/efeitos adversos , Estudos Prospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Temperatura , Resultado do Tratamento
2.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38587017

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , América Latina , Resultado do Tratamento , Catéteres , Ásia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
3.
N Engl J Med ; 382(19): 1823-1831, 2020 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-32374963

RESUMO

BACKGROUND: Access to pacemakers and defibrillators is problematic in places with limited resources. Resterilization and reuse of implantable cardiac devices obtained post mortem from patients in wealthier nations have been undertaken, but uncertainty around the risk of infection is a concern. METHODS: A multinational program was initiated in 1983 to provide tested and resterilized pacemakers and defibrillators to underserved nations; a prospective registry was established in 2003. Patients who received reused devices in this program were matched in a 1:3 ratio with control patients who received new devices implanted in Canada. The primary outcome was infection or device-related death, with mortality from other causes modeled as a competing risk. RESULTS: Resterilized devices were implanted in 1051 patients (mean [±SD] age, 63.2±18.5 years; 43.6% women) in Mexico (36.0%), the Dominican Republic (28.1%), Guatemala (26.6%), and Honduras (9.3%). Overall, 85% received pacemakers and 15% received defibrillators, with one (55.5%), two (38.8%), or three (5.7%) leads. Baseline characteristics did not differ between these patients and the 3153 matched control patients. At 2 years of follow-up, infections had occurred in 21 patients (2.0%) with reused devices and in 38 (1.2%) with new devices (hazard ratio, 1.66; 95% confidence interval, 0.97 to 2.83; P = 0.06); there were no device-related deaths. The most common implicated pathogens were Staphylococcus aureus and S. epidermidis. CONCLUSIONS: Among patients in underserved countries who received a resterilized and reused pacemaker or defibrillator, the incidence of infection or device-related death at 2 years was 2.0%, an incidence that did not differ significantly from that seen among matched control patients with new devices in Canada.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Reutilização de Equipamento , Infecções/etiologia , Marca-Passo Artificial/efeitos adversos , Adulto , Idoso , Estudos de Casos e Controles , Países em Desenvolvimento , Feminino , Seguimentos , Humanos , Incidência , Infecções/epidemiologia , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Mortalidade , Fatores de Risco , Esterilização
4.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37038759

RESUMO

AIMS: To allow timely initiation of anticoagulation therapy for the prevention of stroke, the European guidelines on atrial fibrillation (AF) recommend remote monitoring (RM) of device-detected atrial high-rate episodes (AHREs) and progression of arrhythmia duration along pre-specified strata (6 min…<1 h, 1 h…<24 h, ≥ 24 h). We used the MATRIX registry data to assess the capability of a single-lead implantable cardioverter-defibrillator (ICD) with atrial sensing dipole (DX ICD system) to follow this recommendation in patients with standard indication for single-chamber ICD. METHODS AND RESULTS: In 1841 DX ICD patients with daily automatic RM transmissions, electrograms of first device-detected AHREs per patient in each duration stratum were adjudicated, and the corresponding positive predictive values (PPVs) for the detections to be true atrial arrhythmia were calculated. Moreover, the incidence and progression of new-onset AF was assessed in 1451 patients with no AF history. A total of 610 AHREs ≥6 min were adjudicated. The PPV was 95.1% (271 of 285) for episodes 6min…<1 h, 99.6% (253/254) for episodes 1 h…<24 h, 100% (71/71) for episodes ≥24 h, or 97.5% for all episodes (595/610). The incidence of new-onset AF was 8.2% (119/1451), and in 31.1% of them (37/119), new-onset AF progressed to a higher duration stratum. Nearly 80% of new-onset AF patients had high CHA2DS2-VASc stroke risk, and 70% were not on anticoagulation therapy. Age was the only significant predictor of new-onset AF. CONCLUSION: A 99.7% detection accuracy for AHRE ≥1 h in patients with DX ICD systems in combination with daily RM allows a reliable guideline-recommended screening for subclinical AF and monitoring of AF-duration progression.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/epidemiologia , Desfibriladores Implantáveis/efeitos adversos , Átrios do Coração , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Anticoagulantes
5.
J Cardiovasc Electrophysiol ; 29(2): 308-315, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29064134

RESUMO

INTRODUCTION: Expert societies recently published strong recommendations to reduce the exposure of patients and staff to ionizing radiation (IR) during interventional and electrophysiology (EP) procedures. However, adherence to these guidelines remains difficult and the impact of implementing such recommendations is poorly characterized. METHODS AND RESULTS: We conducted a single-center cohort study to quantify radiation exposure over time in three EP laboratories at the Montreal Heart Institute during 5,546 consecutive procedures from 2012 to 2015 by 11 primary operators. Overall, 2,618 (47.2%) procedures were catheter-based and 2,928 (52.8%) were device interventions. Interventions to reduce radiation exposure included educational initiatives to raise awareness (i.e., limiting cine acquisition, patient position, table height), slower frame rate, lower radiation dose per pulse, collimation, and integration with 3-D mapping systems and/or MediGuide technology. An 85% reduction in IR exposure was observed from 2012 to 2015, with the mean dose-area-product (DAP) decreasing from 7.65 ± 0.05 Gy·cm2 to 1.15 ± 0.04 Gy·cm2 (P < 0.001). This was true for catheter-based procedures (mean DAP 16.99 ± 0.08 to 2.00 ± 0.06 Gy·cm2 , P < 0.001) and device interventions (mean DAP 4.18 ± 0.06 to 0.64 ± 0.05 Gy·cm2 , P < 0.001). The median effective dose of IR recorded per quarter by 282 cervical dosimeters on EP staff decreased from 0.57 (IQR 0.18, 1.03) mSv in 2012 to 0.00 (IQR 0.00, 0.19) mSv in 2015, P < 0.001. CONCLUSION: Enforcing good clinical practices with simple measures and low-dose fluoroscopy settings are highly effective in reducing IR exposure in the EP lab. These promising results should encourage other EP labs to adopt similar protective measures.


Assuntos
Cateterismo Cardíaco/métodos , Técnicas Eletrofisiológicas Cardíacas , Exposição Ocupacional/prevenção & controle , Implantação de Prótese/métodos , Doses de Radiação , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Humanos , Exposição Ocupacional/efeitos adversos , Saúde Ocupacional , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Fatores de Proteção , Exposição à Radiação/efeitos adversos , Proteção Radiológica , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
6.
Europace ; 20(suppl_2): ii1-ii4, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29722859

RESUMO

Aims: Achieving adequate catheter tip-tissue contact is essential for delivering robust radiofrequency (RF) ablation lesions. We measured the contact force generated by a remote magnetic-guided catheter navigation system. Methods and results: A plexiglass model with an integrated scale was fashioned to mimic transvenous and retrograde access to sites in the right atrium and right and left ventricles. An 8 Fr RF ablation catheter was steered by remote magnetic guidance at fields of 0.08 and 0.10 T, with and without a long sheath positioned at the entrance of the chamber. Ten contact force readings were taken at each setting, with the scale recalibrated prior to each measurement. Generalized estimating equations were used to compare contact force measurements while adjusting for the non-independent data structure. A total of 240 contact force measurements were taken. Without a long sheath, contact forces with magnetic fields of 0.10 T (n = 60) and 0.08 T (n = 60) were similar (6.1 ± 1.4 g vs. 6.0 ± 1.3 g, P = 0.089). Contact forces were not significantly different with simulated transvenous (n = 80) and retrograde aortic (n = 40) approaches (6.2 ± 1.4 g vs. 5.7 ± 1.2 g, P = 0.132). The contact force increased substantially with a long sheath (P < 0.001) and was significantly higher with 0.10 T (n = 60) vs. 0.08 T (n = 60) fields (20.4 ± 0.6 g vs. 18.0 ± 0.5 g, P < 0.001). Conclusion: Magnetic fields of 0.08 and 0.10 T provide stable catheter contact forces, as reflected by the small variability between measurements. The average contact force is approximately 6 g without a sheath and increases to 20 g with a long sheath positioned at the entrance of the chamber of interest.


Assuntos
Cateterismo Cardíaco/métodos , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Ventrículos do Coração/cirurgia , Magnetismo/métodos , Cirurgia Assistida por Computador/métodos , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Átrios do Coração/anatomia & histologia , Ventrículos do Coração/anatomia & histologia , Humanos , Magnetismo/instrumentação , Imãs , Modelos Anatômicos , Modelos Cardiovasculares , Pressão , Cirurgia Assistida por Computador/instrumentação , Transdutores de Pressão
7.
J Cardiovasc Electrophysiol ; 28(5): 559-563, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28233925

RESUMO

INTRODUCTION: The standard 4-minute application time for transcatheter cryoablation was determined in the 1990s when the system employed less potent chlorofluorocarbon refrigerants. The current refrigerant, nitrous oxide, generates substantially colder temperatures, with a faster cooling rate. METHODS AND RESULTS: We conducted a preclinical study on 32 mongrel dogs with stratified randomization of right atrial, right ventricular, and left ventricular chambers to 2-minute versus 4-minute application times using 8-mm electrode tip cryocatheters (Freezor Max, Medtronic CryoCath LP, Montreal, Canada). Animals were sacrificed one month after the procedure. Three-dimensional morphometric analyses were conducted in a blinded fashion. A total of 193 identified ablation lesions were processed for histological analyses, 102 with 2-minute applications and 91 with 4-minute applications. Ablation lesion surface area (167.8 ± 21.6 mm2 vs. 194.3 ± 22.6 mm2 , P = 0.40), maximum depth (4.4 ± 0.2 mm vs. 4.5 ± 0.2 mm, P = 0.71), and volume (125.7 ± 69.5 mm3 vs. 141.0 ± 83.5 mm3 , P = 0.25) were similar between groups. Overall, 90.2% of ablation lesions in the right atrium were transmural, 45.6% in the right ventricle, and 2.4% in the left ventricle, with no differences between 2-minute and 4-minute application times (P = 0.55). Thrombus was detected on the endocardial surface of 0.0% and 3.3% of ablation lesions created with 2-minute and 4-minute application times, respectively (P = 0.10). CONCLUSION: Single 2-minute and 4-minute application times result in catheter ablation lesions of similar size using the modern cryoablation system with nitrous oxide as a refrigerant. While these findings suggest the potential to reduce the standard 4-minute application time, further studies are required to compare clinical efficacy.


Assuntos
Cateterismo Cardíaco/métodos , Temperatura Baixa , Criocirurgia/métodos , Átrios do Coração/cirurgia , Ventrículos do Coração/cirurgia , Óxido Nitroso/farmacologia , Animais , Cães , Átrios do Coração/patologia , Ventrículos do Coração/patologia , Modelos Animais , Fatores de Tempo
8.
Europace ; 19(6): 1043-1048, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27377075

RESUMO

AIMS: It remains unknown whether contact force (CF) sensing technology is of value for cavotricuspid isthmus (CTI) ablation. We prospectively evaluated procedural parameters and outcomes of CF-guided vs. CF-blinded CTI ablation for typical atrial flutter (AFL). METHODS AND RESULTS: A total of 70 consecutive patients (62.5 ± 10.9 years) undergoing CTI ablation for AFL were prospectively enrolled, 35 in CF-blinded and 35 in CF-guided groups. A CF-sensing catheter (power 25-35 W) was used in all. In the CF-guided group, CF target range was 10-25 g, whereas in the CF-blinded group, the operator was blinded to CF. The isthmus was divided into anterior, middle, and posterior segments for region-specific CF analysis. The procedural endpoint of bidirectional isthmus block following a 20-min observation period was achieved in all. A trend towards lower fluoroscopy and procedure duration was observed when the CF-guided group was compared with the CF-blinded group. The total radiofrequency (RF) energy delivery time required to achieve bidirectional block was significantly lower in the CF-guided vs. CF-blinded group [10.0 min (IQR 8.3;15.1) vs. 15.9 min (IQR 9.6;24.7), P= 0.0020], with a significant inverse correlation between CF and total RF delivery time (r = -0.36; P= 0.0027). Mean CF measurements significantly increased from anterior to posterior anatomical zones of CTI in the CF-blinded group (ANOVA P= 0.0466). CONCLUSIONS: Catheter ablation of AFL guided by real-time CF assessment results in a significant reduction in total RF delivery time. Real-time CF measurements facilitate the maintenance of homogenous efficient contact all along the CTI, particularly in the anterior segment where CF is generally lower.


Assuntos
Flutter Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Transdutores de Pressão , Potenciais de Ação , Idoso , Análise de Variância , Flutter Atrial/diagnóstico , Flutter Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Distribuição de Qui-Quadrado , Desenho de Equipamento , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 27(11): 1337-1343, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27458078

RESUMO

INTRODUCTION: Cardiac resynchronization therapy (CRT) implant procedures are often complex and prolonged, resulting in substantial ionizing radiation (IR) exposure to the patient and operator. We assessed the impact of lower-dose fluoroscopy settings and a sensor-based electromagnetic tracking system (MediGuide™, MDG) on reducing IR exposure during CRT implantation. METHODS: A single-center 2-group cohort study was conducted on 348 consecutive patients, age 66.4 ± 11.0 years, 80.4% male, with CRT implant procedures from 2013 to 2015. Patients were arbitrarily assigned to MDG (N = 239) versus no MDG (N = 109) guidance. Lower-dose fluoroscopy settings were adopted in January 2015 (3 instead of 6 fps; 23 instead of 40 nGy/pulse; N = 101). RESULTS: Overall, MDG was associated with an 82.1% reduction in IR exposure (393 µGray·m2 vs. 2191 µGray·m2 , P < 0.001). Lower-dose fluoroscopy resulted in a 59.5% reduction in IR-exposure without MDG (1055 µGray·m2 vs. 2608 µGray·m2 , P < 0.001) and 81.8% reduction with MDG (108 µGray·m2 vs. 595 µGray·m2 , P < 0.001). Low-dose fluoroscopy combined with MDG was associated with a 95.9% lower exposure to IR when compared to standard fluoroscopy without MDG (108 µGray·m2 vs. 2608 µGray·m2 , P < 0.001). Procedures with MDG were shorter (96 minutes vs. 123 minutes, P < 0.001) and associated with a trend towards a higher success rate (94.6% vs. 89.0%, P = 0.062), with fewer coronary sinus cannulation failures (2.1% vs. 6.4%, P = 0.040). CONCLUSION: Low-dose fluoroscopy settings are highly effective (>50%) in reducing IR exposure during CRT implant procedures. When combined with MDG, >95% reduction in IR exposure is achieved. Moreover, MDG shortens procedural duration and may improve acute procedural outcomes.

10.
J Cardiovasc Electrophysiol ; 26(12): 1327-32, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26332293

RESUMO

INTRODUCTION: Rate and rhythm control strategies for atrial fibrillation (AF) are not always effective or well tolerated in patients with congestive heart failure (CHF). We assessed reasons for treatment failure, associated characteristics, and effects on survival. METHODS AND RESULTS: A total of 1,376 patients enrolled in the AF-CHF trial were followed for 37  ±  19 months, 206 (15.0%) of whom failed initial therapy leading to crossover. Rhythm control was abandoned more frequently than rate control (21.0% vs. 9.1%, P < 0.0001). Crossovers from rhythm to rate control were driven by inefficacy, whereas worsening heart failure was the most common reason to crossover from rate to rhythm control. In multivariate analyses, failure of rhythm control was associated with female sex, higher serum creatinine, functional class III or IV symptoms, lack of digoxin, and oral anticoagulation. Factors independently associated with failure of rate control were paroxysmal (vs. persistent) AF, statin therapy, and presence of an implantable cardioverter-defibrillator. Crossovers were not associated with cardiovascular mortality (hazard ratio [HR] 1.11 from rhythm to rate control; 95% confidence interval [95% CI, 0.73-1.73]; P = 0.6069; HR 1.29 from rate to rhythm control; 95% CI, 0.73-2.25; P = 0.3793) or all-cause mortality (HR 1.16 from rhythm to rate control, 95% CI [0.79-1.72], P = 0.4444; HR 1.15 from rate to rhythm control, 95% [0.69, 1.91], P = 0.5873). CONCLUSIONS: Rhythm control is abandoned more frequently than rate control in patients with AF and CHF. The most common reasons for treatment failure are inefficacy for rhythm control and worsening heart failure for rate control. Changing strategies does not impact survival.


Assuntos
Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Frequência Cardíaca , Idoso , Antiarrítmicos/uso terapêutico , Anticoagulantes/uso terapêutico , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Fibrilação Atrial/mortalidade , Creatinina/sangue , Desfibriladores Implantáveis , Digoxina/uso terapêutico , Progressão da Doença , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Masculino , Pessoa de Meia-Idade , Fatores Sexuais , Falha de Tratamento
11.
Europace ; 17(9): 1383-90, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25935164

RESUMO

AIMS: Electrical reconnection after pulmonary vein (PV) isolation is associated with atrial fibrillation (AF) recurrence. Reconnection may already develop within a 30 min waiting period and may only occur as dormant conduction (DC) revealed by adenosine infusion. This study determines incidence and predictors of DC after cryoballoon ablation incorporating a 30 min waiting period and the effect of treating this 'late' DC on 1 year AF-recurrence. METHODS AND RESULTS: Consecutive patients scheduled for a first ablation were prospectively included. Intravenous adenosine was administered 30 min after PV isolation to unmask DC (adenosine+). Additional applications were performed to abolish DC. Atrial fibrillation recurrence was evaluated after 3, 6, and 12 months with ECG and 24 h Holter recordings. Results were compared with a prior group of consecutive patients that underwent cryoablation without DC testing (adenosine-). The adenosine+ group consisted of 36 patients (78% male, 61 ± 10 years, paroxysmal AF 86%). ***Dormant conduction was found in 42% of patients (15/36) and 14% of PVs (20/143). Multivariate analysis showed that PV isolation during the first freeze independently reduced DC risk (OR = 0.064, P < 0.01). After 12 ± 1 months, 11 (83%) of adenosine+ patients had no AF-recurrences, compared with 37 (60%) of adenosine- patients (n = 62, 70% male, 59 ± 11 years, 90% paroxysmal AF, P = 0.02). Ablation with DC treatment independently reduced the risk of AF-recurrence (OR = 0.26, P = 0.02). CONCLUSION: Incorporating a 30-min waiting period after cryoballoon ablation increases the incidence of DC compared with previous results. Absence of PV isolation during the first freeze is associated with an increased risk of late DC. Treatment of this DC seems to improve outcome.


Assuntos
Adenosina/administração & dosagem , Antiarrítmicos/administração & dosagem , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Complicações Pós-Operatórias , Veias Pulmonares/cirurgia , Idoso , Criocirurgia/métodos , Eletrocardiografia Ambulatorial , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Recidiva , Resultado do Tratamento
12.
Pacing Clin Electrophysiol ; 38(1): 63-70, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25311868

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) implant procedures are often complex and prolonged, resulting in significant ionizing radiation (IR) exposure to the patient and operator. We report our early experience working with a novel sensor-based electromagnetic tracking system (MediGuide™, MDG, St. Jude Medical Inc., St. Paul, MN, USA), in terms of procedural IR exposure reduction. METHODS AND RESULTS: Information regarding patient demographics, procedural details, procedural duration, and IR exposure were prospectively collected on 130 consecutive CRT procedures performed between January 2013 and January 2014. Sixty procedures were performed with MDG guidance, and 70 were performed without MDG guidance. Despite a nonsignificant trend toward shorter procedure duration with the use of MDG (120 minutes vs 138 minutes with non-MDG, P = 0.088), a 66% reduction in total IR exposure (median 769 µGray · m(2) vs 2,608 µGray · m(2), P < 0.001) was found. This reduction was primarily driven by a >90% reduction in IR dose required to cannulate the coronary sinus (median 80 µGray · m(2) vs 922 µGray · m(2), P < 0.001), and to a lesser extent from a reduction in IR dose required for LV lead placement (median 330 µGray·m(2) vs 737 µGray · m(2), P = 0.059). In addition, a significant learning curve effect was observed with a significantly shorter procedural duration for the last 15 cases compared to the first 15 cases (median 98 minutes vs 175 minutes, P < 0.001). CONCLUSION: The nonfluoroscopic MDG positioning system is associated with a dramatic reduction in exposure to IR during CRT implant procedures, with a 90% decrease in the IR dose required to cannulate the coronary sinus. A steep learning curve was quantified.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Implantação de Prótese/métodos , Lesões por Radiação/prevenção & controle , Idoso , Radiação Eletromagnética , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Cirurgia Assistida por Computador
13.
Pacing Clin Electrophysiol ; 38(7): 784-90, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25682843

RESUMO

BACKGROUND: Fluoroscopic guidance is used to position catheters during cardiac ablation. We evaluated the impact of a novel nonfluoroscopic sensor-guided electromagnetic navigation system (MG) on radiation exposure during catheter ablation of atrial fibrillation (AF) or atrial flutter (AFL). METHODS: A total of 134 consecutive patients referred for ablation of AF (n = 44) or AFL (n = 90) ablation were prospectively enrolled. In one group the MG system was used for nonfluoroscopic catheter positioning, whereas in the conventional group standard fluoroscopy was utilized. Fluoroscopy times were assessed for each stage of procedure and total radiation exposure was quantified. RESULTS: Patient characteristics were similar between the groups. The procedural end point was achieved in all. Median (interquartile range [IQR]) fluoroscopy times were 12.5 minutes (7.6, 17.4) MG group versus 21.5 minutes (15.3, 23.0) conventional group (P < 0.0001) for AF ablation, and 0.8 minutes (0.4, 2.5) MG group versus 9.9 minutes (5.1, 22.5) conventional group (P < 0.0001) for AFL ablation. Median (IQR) total radiation exposure (µGy·m(2)) was 1,107 (906, 2,033) MG group versus 2,835 (1,688, 3,855) conventional group (P = 0.0001) for AF ablation, and 161 (65, 537) MG group versus 1,651 (796, 4,569) conventional group (P < 0.0001) for AFL ablation. No difference in total procedural time was seen. CONCLUSIONS: The use of a novel nonfluoroscopic catheter tracking system is associated with a significant reduction in radiation exposure during AF and AFL ablation (61% and 90% reduction, respectively). In the era of heightened awareness of the importance of radiation reduction, this system represents a safe and efficient tool to decrease radiation exposure during electrophysiological ablation procedures.


Assuntos
Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/métodos , Exposição à Radiação/análise , Radiografia Intervencionista/instrumentação , Fibrilação Atrial/diagnóstico por imagem , Flutter Atrial/diagnóstico por imagem , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Doses de Radiação , Proteção Radiológica , Radiografia Intervencionista/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
14.
J Card Fail ; 20(5): 365-72, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24508810

RESUMO

BACKGROUND: Invasively measured maximum increase in left ventricular pressure (LV dP/dtmax) has been used to assess biventricular (BiV) pacing. We quantified extracardiac factors contributing to its variability, and developed a protocol to minimize these effects in an acute pacing experiment. METHODS AND RESULTS: Continuous pressure was recorded by a guidewire sensor placed in the LV. Four to six test pacing interventions were performed, each repeated 3 times and followed by a baseline pacing configuration. Maximum increase in LV dP/dtmax from any measurement of BiV pacing was median 20.3% in 25 patients, compared with BiV pacing off. When directly comparing sequential measurements with BiV pacing on and off, median increase was 7.4%. Noncardiac sources of modulation included respiratory variation (6.4%), drift from first to last baseline measurement (5.0%), and discrepancy among repeated recordings of the same pacing intervention (3.3%). Comparing test interventions to interleaved baseline measurements reduced discrepancy among recordings to 2.1%; P < .001. CONCLUSIONS: With repeated measurements of baseline state, and by comparing test interventions only to baseline measurements performed before and after, it is possible to minimize extracardiac factors and focus on the effects of test pacing interventions.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Hemodinâmica/fisiologia , Projetos de Pesquisa/normas , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico
15.
Heart Rhythm O2 ; 5(4): 234-242, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38690147

RESUMO

Background: Cardiac radioablation is a new treatment for patients with refractory ventricular tachycardia (VT). The target for cardiac radioablation is subject to cardiorespiratory motion (CRM), the heart's movement with breathing and cardiac contraction. Data regarding the magnitude of target CRM are limited but are highly important for treatment planning. Objectives: The study sought to assess CRM amplitude by using ablation catheter geometrical data. Methods: Electroanatomic mapping data of patients undergoing catheter ablation for VT at 3 academic centers were exported. The spatial position of the ablation catheter as a function of time while in contact with endocardium was analyzed and used to quantify CRM. Results: Forty-four patients with ischemic and nonischemic cardiomyopathy and VT contributed 1364 ablation lesions to the analysis. Average cardiac and respiratory excursion were 1.62 ± 1.21 mm and 12.12 ± 4.10 mm, respectively. The average ratio of respiratory to cardiac motion was approximately 11:1. CRM was greatest along the craniocaudal axis (9.66 ± 4.00 mm). Regional variations with respect to respiratory and cardiac motion were observed: basal segments had smaller displacements vs midventricular and apical segments. Patient characteristics (previous cardiac surgery, height, weight, body mass index, and left ventricular ejection fraction) had a statistically significant, albeit clinically moderate, impact on CRM. Conclusion: CRM is primarily determined by respiratory displacement and is modulated by the location of the target and the patient's biometric characteristics. The patient-specific quantification of CRM may allow to decrease treatment volume and reduce radiation exposure of surrounding organs at risk while delivering the therapeutic dose to the target.

16.
J Interv Card Electrophysiol ; 67(5): 921-1072, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38609733

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Consenso , Sociedades Médicas , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Humanos , Europa (Continente) , América Latina , Ásia
17.
Heart Rhythm ; 21(9): e31-e149, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38597857

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Consenso , Sociedades Médicas , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Humanos , Ablação por Cateter/métodos , Europa (Continente) , América Latina , Ásia
19.
Pacing Clin Electrophysiol ; 36(11): 1417-26, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23875951

RESUMO

BACKGROUND: There is no scientific literature that examines radiofrequency (RF) interference from Smart Meters with cardiac implantable electronic devices (CIEDs). The objective of this in vitro study was to assess any potential interference with Medtronic CIEDs (Medtronic Inc., Minneapolis, MN, USA). METHODS: In the Quebec testing, five models of Medtronic CIEDs were placed in an acrylic cylinder filled with a saline solution and faced a Landis+Gyr Smart Meter or Router (Landis+Gyr AG, Zug, Switzerland). The distance between CIEDs and the meter casing or router antenna was 10 cm. The Meter's normal operating conditions were modified to artificially set the number of impulsions at an abnormally high level (one, two, and three impulses per second). Each scenario was repeated one to five times, for 1 minute each. In the U.S. testing, 6 cm and 15 cm (∼2.25' and ∼6') separated the six models of Medtronic CIEDs from the Schlumberger Smart Meter (Itron Inc., Liberty Lake, WA, USA), which generally sent out a 96-bit Standard Consumption Message over 3 seconds. The transmission varied in frequencies along with the interval between cycles. RESULTS: A total of 6,966 RF transmissions were completed during the 34 tests conducted in Quebec. In the United States, the CIED was exposed to the meter for 10 minutes to provide a minimum of 200 completed RF transmissions. No interference was observed in worst-case scenarios (testing of meters and CIEDs at their performance limits). CONCLUSIONS: Landis+Gyr Smart Meters/Routers and Schlumberger Smart Meters do not interfere with the functioning of the Medtronic CIEDs tested, when placed, respectively, 10 cm and 6 cm and 15 cm apart.


Assuntos
Artefatos , Redes de Comunicação de Computadores/instrumentação , Desfibriladores Implantáveis , Fontes de Energia Elétrica , Falha de Equipamento , Marca-Passo Artificial , Tecnologia sem Fio/instrumentação , Eletricidade , Análise de Falha de Equipamento/métodos , Quebeque
20.
Expert Rev Cardiovasc Ther ; 21(3): 227-236, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36852632

RESUMO

BACKGROUND: Robotic magnetic navigation (RMN) has emerged as a potential solution to overcome challenges associated with catheter ablation of arrhythmias in patients with congenital heart disease (CHD). OBJECTIVES: To assess safety and efficacy of RMNguided catheter ablation in patients with CHD. DESIGN AND METHODS: A systematic review and pooled analysis was conducted on patients with CHD who underwent RMNguided catheter ablation. Random effects models were used to generate pooled estimates with the inverse variance method used for weighting studies. RESULTS: Twentyfour nonoverlapping records included 167 patients with CHD, mean age 36.5 years, 44.6% female. Type of CHD was simple in 27 (16.2%), moderate in 32 (19.2%), and complex in 106 (63.5%). A total of 202 procedures targeted 260 arrhythmias, the most common being macroreentrant atrial circuits. The mean procedural duration was 207.5 minutes, with a mean fluoroscopy time of 12.1 minutes. The pooled acute success rate was 89.2% [95% CI (77.8%, 97.4%)]. Freedom from arrhythmia recurrence was 84.5% [95% CI (72.5%, 94.0%)] over a mean follow-up of 24.3 months. The procedural complication rate was 3.5% with no complication attributable to RMN technology. CONCLUSION: RMN-guided ablation appears to be safe and effective across a variety of arrhythmia substrates and types of CHD.


Assuntos
Ablação por Cateter , Cardiopatias Congênitas , Procedimentos Cirúrgicos Robóticos , Humanos , Feminino , Adulto , Masculino , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Resultado do Tratamento , Cardiopatias Congênitas/complicações , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fenômenos Magnéticos