Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 28(6): 2406-2416, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29318430

RESUMO

OBJECTIVES: To investigate safety and diagnostic value of 1.5-T MRI in carriers of conventional pacemaker (cPM) or conventional implantable defibrillator (cICD). METHODS: We prospectively compared cPM/cICD-carriers undergoing MRI (study group, SG), excluding those device-dependent or implanted <6 weeks before enrolment or prior to 01/01/2000, with cPM/cICD-carriers undergoing chest x-ray, CT or follow-up (reference group, RG). RESULTS: 142 MRI (55 cardiac) were performed in 120 patients with cPM (n=71) or cICD (n=71). In the RG 98 measurements were performed in 95 patients with cPM (n=40) or cICD (n=58). No adverse events were observed. No MRI prolonged/interrupted. All cPM/cICD were correctly reprogrammed after MRI without malfunctions. One temporary communication failure was observed in one cPM-carrier. Immediately after MRI, 12/14 device interrogation parameters did not change significantly (clinically negligible changes of battery voltage and cICD charging time), without significant variations for SG versus RG. Three-12 months after MRI, 9/11 device interrogation parameters did not change significantly (clinically negligible changes of battery impedance/voltage). Non-significant changes of three markers of myocardial necrosis. Non-cardiac MRI: 82/87 diagnostic without artefacts; 4/87 diagnostic with artefacts; 1/87 partially diagnostic. Cardiac MRI: in cPM-carriers, 14/15 diagnostic with artefacts, 1/15 partially diagnostic; in cICD-carriers, 9/40 diagnostic with artefacts, 22 partially diagnostic, nine non-diagnostic. CONCLUSIONS: A favourable risk-benefit ratio of 1.5-T MRI in cPM/cICD carriers was reported. KEY POINTS: • Cooperation between radiologists and cardiac electrophysiologists allowed safe 1.5-T MRI in cPM/cICD-carriers. • No adverse events for 142 MRI in 71 cPM-carriers and 71 cICD-carriers. • Ninety-nine per cent (86/87) of non-cardiac MRI in cPM/cICD-carriers were diagnostic. • All cPM-carrier cardiac MRIs had artefacts, 14 examinations diagnostic, 1 partially diagnostic. • Twenty-three per cent (9/40) of cardiac MRI in cICD-carriers were non-diagnostic.


Assuntos
Arritmias Cardíacas/terapia , Artefatos , Desfibriladores Implantáveis , Imageamento por Ressonância Magnética/normas , Marca-Passo Artificial , Idoso , Arritmias Cardíacas/diagnóstico por imagem , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Seguimentos , Humanos , Imagem Cinética por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
2.
Artigo em Inglês | MEDLINE | ID: mdl-28008694

RESUMO

Regular narrow QRS tachycardia, particularly if well-tolerated, is usually considered a "benign" arrhythmia of a supraventricular origin. This case concerns an 82-year-old male with ischemic heart disease who presented with recurrent episodes of a narrow QRS tachycardia that was initially diagnosed and treated as atrial tachyarrhythmia. However, careful physical examination and ECG analysis established the correct diagnosis, and the patient was managed appropriately. Remarkably, the observation of irregular cannon A waves, and Lewis lead recording, confirmed atrioventricular dissociation during tachycardia and indicated its underlying mechanism.


Assuntos
Eletrocardiografia/métodos , Bloqueio Cardíaco/complicações , Bloqueio Cardíaco/diagnóstico , Taquicardia Ventricular/complicações , Taquicardia Ventricular/diagnóstico , Idoso de 80 Anos ou mais , Cicatriz/complicações , Cicatriz/diagnóstico , Diagnóstico Diferencial , Humanos , Masculino
3.
Artigo em Inglês | MEDLINE | ID: mdl-27440741

RESUMO

Complete left bundle branch block (LBBB) is established according to standard electrocardiographic criteria. However, functional LBBB may be rate-dependent or can perpetuate during tachycardia due to repetitive concealed retrograde penetration of impulses through the contralateral bundle "linking phenomenon." In this brief article, we present two patients with basal complete LBBB in whom ablating the right bundle unmasked the actual antegrade conduction capabilities of the left bundle. These cases highlight intriguing overlap between electrophysiological concepts of complete block, linking, extremely slow, and concealed conduction.


Assuntos
Fascículo Atrioventricular/fisiopatologia , Fascículo Atrioventricular/cirurgia , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/cirurgia , Ablação por Cateter/métodos , Idoso , Idoso de 80 Anos ou mais , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Resultado do Tratamento
4.
J Electrocardiol ; 50(1): 148-150, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27443783

RESUMO

Ventricular fibrillation is typically the initial arrhythmia in commotio cordis following precordium impacts that occur within an electrically vulnerable period of the cardiac cycle. Conversely, complete heart block is very rare in this context, and its mechanism and temporal course are poorly understood. The presented case concerns a 12-year-old boy, athletic skier, who developed a transient complete heart block following commotio cordis. The electrocardiographic features, the proposed block level and mechanisms of complete heart block following commotio cordis are discussed.


Assuntos
Traumatismos em Atletas/diagnóstico , Commotio Cordis/diagnóstico , Eletrocardiografia/métodos , Bloqueio Cardíaco/diagnóstico , Esqui/lesões , Criança , Diagnóstico Diferencial , Humanos , Masculino
5.
Ann Noninvasive Electrocardiol ; 21(4): 420-4, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26969821

RESUMO

Intravenous adenosine is a short-acting blocker of the atrioventricular node that has been used to unmask subtle or latent preexcitation, and also to enable catheter ablation in selected patients with absent or intermittent preexcitation. Depending on the accessory pathway characteristics, intravenous adenosine may produce specific electrocardiographic changes highly suggestive of the preexcitation variant. Herein, we view different ECG responses to this pharmacological test in various preexcitation patterns that were confirmed by electrophysiological studies. Careful analysis of electrocardiographic changes during adenosine test, with emphasis on P-delta interval, preexcitation degree, and atrioventricular block, can be helpful to diagnose the preexcitation variant/pattern.


Assuntos
Adenosina/uso terapêutico , Antiarrítmicos/uso terapêutico , Eletrocardiografia/métodos , Síndromes de Pré-Excitação/tratamento farmacológico , Síndromes de Pré-Excitação/fisiopatologia , Síndrome de Wolff-Parkinson-White/tratamento farmacológico , Síndrome de Wolff-Parkinson-White/fisiopatologia , Adolescente , Adulto , Ablação por Cateter , Teste de Esforço , Feminino , Humanos , Masculino , Síndrome de Wolff-Parkinson-White/cirurgia
7.
J Arrhythm ; 36(4): 685-691, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32782640

RESUMO

BACKGROUND: Catheter ablation for atrial fibrillation (AF) traditionally requires the use of circular mapping catheter (CMC) for pulmonary vein isolation (PVI). This study aimed to assess the feasibility and effectiveness of a CMC-free approach for AF ablation performed by a contiguous optimized (CLOSE) ablation protocol. METHODS: A CLOSE-guided and CMC-free PVI protocol with a single transseptal puncture was attempted in 67 patients with AF. Left atrial (LA) CARTO voltage mapping was performed with the ablation catheter pre- and postablation to demonstrate entry block into the pulmonary veins, and pacing maneuvers were used to confirm exit block. RESULTS: The CMC-free approach was successful in achieving PVI in 66 (98.5%) cases, with procedure time of 148 ± 32 minutes, ablation time of 27.5 ± 5.7 minutes, and fluoroscopy time of 7.8 ± 1.0 minutes. First-pass PVI was seen in 58(86.5%) patients, and pacing maneuvers successfully identified the residual gap in eight of the other nine cases. No complication was observed. At 12 months follow-up, 60 (89.6%) patients remained free from AF. The CMC-free approach resulted in a cost saving of £47,190. CONCLUSION: A CMC-free CLOSE-guided PVI approach is feasible, safe, and cost-saving, and is associated with excellent clinical outcomes at 1 year.

8.
J Arrhythm ; 35(2): 290-295, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31007796

RESUMO

AIM: Ectopic atrial tachycardia (EAT) is a common arrhythmia in children, adolescents, and young adults. Radiofrequency (RF) ablation is often considered the treatment of choice in this population. We sought to evaluate the long-term follow-up after RF ablation. METHODS AND RESULTS: We retrospectively analyzed 36 young patients (age range 8-29 years), with clinical signs and symptoms suspected for EAT who underwent an electrophysiological study in our center. We evaluated the safety and acute success rate of ablation and the long-term follow-up. Ectopic foci were more frequently localized in the right atrium along the crista terminalis (28%) and EAT was successfully terminated in 97% of patients. At median follow-up (38 months), the recurrence rate was 20% with mostly recurrences expressed within 6 months. CONCLUSIONS: The study confirmed the safety and high acute success rate of EAT ablation in a population of children, adolescents, and young adults. Therefore, catheter ablation of EAT can be considered early in the course of treatment of these patients. The evidence of most recurrences within 6 months could be useful for advising patients on likely outcomes.

9.
Heart Rhythm ; 14(10): 1561-1569, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28583850

RESUMO

The underlying mechanisms and temporal course of complete heart block (CHB) after blunt cardiac injuries (BCIs) are poorly understood, and a systematic analysis of available data is lacking. In this systematic review, PubMed was searched for publications of reported cases of CHB-BCI analyzing clinical findings, electrocardiographic features, temporal course, and outcomes. Case reports on CHB-BCI were available for 50 patients, mainly secondary to traffic or sport accidents. A fatal outcome occurred in 10 of 50 (20%) of patients, while a structural damage of the atrioventricular (AV) conductive system was evident in 4 of 8 (50%) of necropsy studies. Clinical manifestation of CHB-BCI occurred within 72 hours of injury in 38 of 47 (∼80%) of patients, and 1:1 AV conduction was restored within 7-10 days in about half of early survivors. Permanent pacemaker implantation was indicated in 22 of 42 (∼50%) of early survivors because of recurrent or permanent CHB. Cardiac troponins, when analyzed, were elevated in 12 of 13 (∼90%) of patients, and electrocardiographic features of aberrancy were present in 29 of 40 (>70%) of patients. In conclusion, CHB secondary to BCI is associated with 20% mortality mainly occurring in the early posttraumatic period and most of the deaths are due to or triggered by this malignant arrhythmia. Recurrent or permanent CHB requiring pacemaker implantation occurs in ∼50% of survivors. A structural damage of the AV conductive system can be found in 50% of necropsy studies.


Assuntos
Bloqueio Atrioventricular , Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Contusões Miocárdicas/complicações , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/fisiopatologia , Humanos
10.
Heart Rhythm ; 13(2): 519-26, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26552752

RESUMO

BACKGROUND: The relevance of the temporal relationship between a unipolar electrogram (UEGM) and a bipolar electrogram (BEGM) in determining the site of origin (SOO) of focal arrhythmias has been largely demonstrated. OBJECTIVE: We sought to demonstrate that a negative concordance in the initial forces of these EGMs is also helpful in predicting the SOO of premature ventricular contractions (PVCs). METHODS: Mapping and radiofrequency (RF) ablation were performed in 41 patients with symptomatic PVCs in the absence of structural heart disease. Simultaneous recordings of the minimally filtered (0.5-500 Hz) UEGM and filtered BEGM (30-500 Hz) were analyzed at 247 mapping sites, where RF was attempted. EGMs of 63 mechanically induced PVCs were separately analyzed as a validation group. All ablation sites had a QS pattern in the UEGM. Acute PVC suppression was defined as a complete disappearance of ventricular ectopic beats after a 60-second pulse of RF. RESULTS: RF ablation obtained PVC suppression (RF+) in 33 of 247 sites (13.3%). A negative concordance pattern (NCP) during the initial 20 ms of both UEGM and BEGM was observed in 31 of 33 (94%) RF+ sites compared with 10 of 214 (4%)RF- sites (P < .0001). The NCP criterion demonstrated to be an additional powerful predictor of acute RF success with sensitivity, specificity, positive predictive value, and negative predictive value of 94%, 95%, 76%, and 99%, respectively. Similarly to RF+ sites, the NCP was observed in 60 of 63 sites (95.2%) in the mechanical PVC group. CONCLUSION: An NCP in both UEGM and BEGM may be an additional criterion that helps to localize the SOO of focal ventricular arrhythmias.


Assuntos
Ablação por Cateter/métodos , Vetorcardiografia/métodos , Complexos Ventriculares Prematuros , Adolescente , Adulto , Idoso , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Seleção de Pacientes , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Avaliação de Sintomas , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA