1.
Anal Chem ; 86(7): 3240-53, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24432804

RESUMO

Nearing 30 years since its introduction, 3D printing technology is set to revolutionize research and teaching laboratories. This feature encompasses the history of 3D printing, reviews various printing methods, and presents current applications. The authors offer an appraisal of the future direction and impact this technology will have on laboratory settings as 3D printers become more accessible.


Assuntos
Biotecnologia , Química , Impressão Tridimensional/normas
2.
Nitric Oxide ; 38: 1-7, 2014 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-24530476

RESUMO

Red blood cells (RBCs) release adenosine triphosphate (ATP) in response to a variety of stimuli, including flow-induced deformation. Hydroxyurea (HU), a proven therapy for individuals with sickle cell disease (SCD), is known to improve blood flow. However, the exact mechanism leading to the improved blood flow is incomplete. Here, we report that the incubation of human RBCs with HU enhances ATP release from these cells and that this ATP is capable of stimulating nitric oxide (NO) production in an endothelium. RBCs incubated with HU were pumped through micron-size flow channels in a microfluidic device. The release of ATP from the RBCs was measured using the luciferin-luciferase assay in detection wells on the device that were separated from the flow channels by a porous polycarbonate membrane. NO released from a layer of bovine artery endothelial cells (bPAECs) cultured on the polycarbonate membrane was also measured using the extracellular NO probe DAF-FM. ATP release from human RBCs incubated with 100 µM HU was observed to be 2.06±0.37-fold larger than control samples without HU (p<0.05, N ≥ 3). When HU-incubated RBCs were flowed under a layer of bPAECs, NO released from the bPAEC layer was measured to be 1.34±0.10-fold higher than controls. An antagonist of the P2Y receptor established that this extra 30% increase in NO release is ATP mediated. Furthermore, when RBCs were incubated with L-NAME, a significant decrease in endothelium-derived NO production was observed. Control experiments suggest that RBC-generated NO indirectly affects endothelial NO production via its effects on RBC-derived ATP release.


Assuntos
Trifosfato de Adenosina/metabolismo , Endotélio/metabolismo , Eritrócitos/efeitos dos fármacos , Eritrócitos/metabolismo , Hidroxiureia/farmacologia , Óxido Nítrico/biossíntese , Relação Dose-Resposta a Droga , Humanos , Técnicas Analíticas Microfluídicas , Relação Estrutura-Atividade
3.
Analyst ; 139(22): 5686-94, 2014 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-25105251

RESUMO

In this paper, we describe the development of a planar, pillar array device that can be used to image either side of a tunable membrane, as well as sample and detect small molecules in a cell-free region of the microchip. The pores are created by sealing two parallel PDMS microchannels (a cell channel and a collector channel) over a gold pillar array (5 or 10 µm in height), with the device being characterized and optimized for small molecule cross-over while excluding a flowing cell line (here, red blood cells, RBCs). The device was characterized in terms of the flow rate dependence of analyte cross-over and cell exclusion as well as the ability to perform amperometric detection of catechol and nitric oxide (NO) as they cross-over into the collector channel. Using catechol as the test analyte, the limits of detection (LOD) of the cross-over for the 10 µm and 5 µm pillar array heights were shown to be 50 nM and 105 nM, respectively. Detection of NO was made possible with a glassy carbon detection electrode (housed in the collector channel) modified with Pt-black and Nafion, to enhance sensitivity and selectivity, respectively. Reproducible cross-over of NO as a function of concentration resulted in a linear correlation (r(2) = 0.995, 7.6-190 µM), with an LOD for NO of 230 nM on the glassy carbon/Pt-black/0.05% Nafion electrode. The applicability of the device was demonstrated by measuring the NO released from hypoxic RBCs, with the device allowing the released NO to cross-over into a cell free channel where it was detected in close to real-time. This type of device is an attractive alternative to the use of 3-dimensional devices with polycarbonate membranes, as either side of the membrane can be imaged and facile integration of electrochemical detection is possible.


Assuntos
Eletrodos , Microfluídica/instrumentação , Catecóis/análise , Eritrócitos/química , Análise de Injeção de Fluxo , Humanos , Limite de Detecção , Óxido Nítrico/análise
4.
Lab Chip ; 14(12): 2023-32, 2014 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-24763966

RESUMO

We report two 3D printed devices that can be used for electrochemical detection. In both cases, the electrode is housed in commercially available, polymer-based fittings so that the various electrode materials (platinum, platinum black, carbon, gold, silver) can be easily added to a threaded receiving port printed on the device; this enables a module-like approach to the experimental design, where the electrodes are removable and can be easily repolished for reuse after exposure to biological samples. The first printed device represents a microfluidic platform with a 500 × 500 µm channel and a threaded receiving port to allow integration of either polyetheretherketone (PEEK) nut-encased glassy carbon or platinum black (Pt-black) electrodes for dopamine and nitric oxide (NO) detection, respectively. The embedded 1 mm glassy carbon electrode had a limit of detection (LOD) of 500 nM for dopamine and a linear response (R(2) = 0.99) for concentrations between 25-500 µM. When the glassy carbon electrode was coated with 0.05% Nafion, significant exclusion of nitrite was observed when compared to signal obtained from equimolar injections of dopamine. When using flow injection analysis with a Pt/Pt-black electrode and standards derived from NO gas, a linear correlation (R(2) = 0.99) over a wide range of concentrations (7.6-190 µM) was obtained, with the LOD for NO being 1 µM. The second application showcases a 3D printed fluidic device that allows collection of the biologically relevant analyte adenosine triphosphate (ATP) while simultaneously measuring the release stimulus (reduced oxygen concentration). The hypoxic sample (4.8 ± 0.5 ppm oxygen) released 2.4 ± 0.4 times more ATP than the normoxic sample (8.4 ± 0.6 ppm oxygen). Importantly, the results reported here verify the reproducible and transferable nature of using 3D printing as a fabrication technique, as devices and electrodes were moved between labs multiple times during completion of the study.


Assuntos
Dopamina/análise , Técnicas Eletroquímicas , Técnicas Analíticas Microfluídicas , Óxido Nítrico/análise , Impressão Tridimensional , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Eletrodos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Oxigênio/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA