Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Mikrobiyol Bul ; 58(2): 209-219, 2024 Apr.
Artigo em Turco | MEDLINE | ID: mdl-38676587

RESUMO

Scedosporium/Lomentospora is an opportunistic fungal pathogen found worldwide. While Scedosporium apiospermum and Scedosporium boydii are commonly observed globally, Lomentospora prolificans, which mainly affects immunosuppressed individuals, is rarely encountered and is more prevalent in arid climates, particularly in Australia and Spain. L.prolificans is a fungus commonly found in environmental sources such as contaminated water and soil. This species is known as an opportunistic pathogen that can cause deep-seated fungal infections, especially in immunosuppressed individuals. In this case report, a fatal case of L.prolificans fungemia in a patient with T-cell large granular leukemia during profound neutropenia was presented. The patient admitted to the hospital with prolonged fever, neutropenia, and shortness of breath. Antibiotherapy was administered to the patient for febrile neutropenia, but the fever persisted and his clinical status rapidly deteriorated. L.prolificans was isolated from the blood culture, and considering its antifungal resistance, combination therapy of voriconazole and terbinafine was initiated. However, the patient died of septic shock and multiple organ failure. In conclusion, although L.prolificans infections are rare, they can be life-threatening, especially in immunosuppressed individuals. Diagnosis and treatment of such infections may be difficult, therefore rapid diagnostic methods and appropriate treatment protocols should be developed. Consideration of infections caused by rare fungal pathogens in patients with risk factors may be critical for patient care. The literature review revealed that the first case of L.prolificans fungemia from Türkiye was reported in 2023. This case presentation represents the second reported case. However, in our case, L.prolificans fungemia occurred in 2018, it can be considered that L.prolificans may have been an invasive fungal pathogen of significant concern in Türkiye much earlier than previously documented.


Assuntos
Antifúngicos , Fungemia , Voriconazol , Humanos , Evolução Fatal , Fungemia/microbiologia , Fungemia/tratamento farmacológico , Fungemia/diagnóstico , Fungemia/complicações , Antifúngicos/uso terapêutico , Masculino , Voriconazol/uso terapêutico , Terbinafina/uso terapêutico , Choque Séptico/microbiologia , Choque Séptico/tratamento farmacológico , Hospedeiro Imunocomprometido , Infecções Oportunistas/microbiologia , Infecções Oportunistas/tratamento farmacológico , Infecções Oportunistas/diagnóstico , Infecções Oportunistas/complicações , Quimioterapia Combinada , Pessoa de Meia-Idade , Scedosporium/isolamento & purificação
2.
Phys Chem Chem Phys ; 20(17): 11598-11607, 2018 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-29651474

RESUMO

Fast dynamics (down to 10 ms) during exposure to changing relative humidity of single optically trapped K2CO3 particles were observed in the submicron to micron size range with time-resolved broadband light scattering and Raman spectroscopy. The study shows that complex multiple processes accompany efflorescence and deliquescence of unsupported aerosol particles. Efflorescence can occur in a single process in less than 10 ms (prompt) or proceed via multiple successive processes (multistep) that can last up to more than 10 seconds. The efflorescence relative humidity lies in the range of 9 to 25%. Raman spectra of the effloresced particles reveal that the final state of the particle is independent of the pathway. Deliquescence cycles start with an initial uptake of water followed by multiple complex processes which end at the deliquescence relative humidity (44-50%). The study reveals that complex multiple processes during phase transitions are not limited to deposited particles where heterogeneous processes may occur or large particles in the upper micrometer size range as previously observed.

3.
Phys Chem Chem Phys ; 18(7): 5477-85, 2016 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-26863396

RESUMO

We describe a broadband light scattering setup for the characterization of size and refractive index of single submicron-to-micron sized aerosol particles. Individual particles are isolated in air by a quadruple Bessel beam optical trap or a counter-propagating optical tweezer. The use of very broadband radiation in the wavelength range from 320 to 700 nm covering the ultraviolet region allows to size submicron particles. We show that a broad wavelength range is required to determine the particle radius and the refractive index with an uncertainty of several nanometers and ∼ 0.01, respectively. The smallest particle radius that can be accurately determined lies around 300 nm. Wavelength-dependent refractive index data over a broad range are obtained, including the ultraviolet region where corresponding data are rare. Four different applications are discussed: (1) the sizing of submicron polystyrene latex spheres, (2) the evaporation of binary glycerol water droplets, (3) hydration/dehydration cycling of aqueous potassium carbonate droplets, and (4) photochemical reactions of oleic acid droplets.

5.
J Chem Phys ; 142(15): 154506, 2015 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-25903896

RESUMO

We report on the dynamics of aerosol droplets in optical traps under the influence of additional constant and pulsed external forces. Experimental results are compared with simulations of the three-dimensional droplet dynamics for two types of optical traps, the counter-propagating Bessel beam (CPBB) trap and the quadruple Bessel beam (QBB) trap. Under the influence of a constant gas flow (constant external force), the QBB trap is found to be more stable compared with the CPBB trap. By contrast, under pulsed laser excitation with laser pulse durations of nanoseconds (pulsed external force), the type of trap is of minor importance for the droplet stability. It typically needs pulsed laser forces that are several orders of magnitude higher than the optical forces to induce escape of the droplet from the trap. If the droplet strongly absorbs the pulsed laser light, these escape forces can be strongly reduced. The lower stability of absorbing droplets is a result of secondary thermal processes that cause droplet escape.

6.
Chronic Illn ; 20(1): 86-95, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-36883242

RESUMO

OBJECTIVES: To evaluate the presence of chronic critical illness (CCI) in COVID-19 patients and compare clinical characteristics and prognosis of patients with and without CCI admitted to intensive care unit (ICU). METHODS: It was a retrospective, observational study at a university hospital ICU. Patients were accepted as CCI if they had prolonged ICU stay (≥14 days) and got ≥1 score for cardiovascular sequential organ failure assessment (SOFA) score and ≥2 score in other parameters on day 14 of ICU admission which was described as persistent organ dysfunction. RESULTS: 131 of 397 (33%) patients met CCI criteria. CCI patients were older (p = 0.003) and frailer (p < 0.001). Their Acute Physiology and Chronic Health Evaluation (APACHE) II and SOFA scores were higher, PaO2/FiO2 ratio was lower (p < 0.001). Requirement of invasive mechanical ventilation (IMV), steroid use, and septic shock on admission were higher in the CCI group (p < 0.001). CCI patients had higher ICU and hospital mortality than other patients (54.2% vs. 19.9% and 55.7% vs. 22.6%, p < 0.001, respectively). Regression analysis revealed that IMV (OR: 8.40, [5.10-13.83], p < 0.001) and PaO2/FiO2 < 150 on admission (OR: 2.25, [1.36-3.71], p = 0.002) were independent predictors for CCI. DISCUSSION: One-third of the COVID-19 patients admitted to the ICU were considered as CCI with significantly higher ICU and hospital mortality.


Assuntos
COVID-19 , Humanos , Estado Terminal , Estudos Retrospectivos , APACHE , Unidades de Terapia Intensiva , Prognóstico
7.
Turk Thorac J ; 23(5): 336-342, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35943069

RESUMO

OBJECTIVE: This study investigated the efficacy of high-flow nasal oxygen therapy in patients with severe acute exacerbation of chronic obstructive pulmonary disease admitted to the intensive care unit. MATERIAL AND METHODS: Totally, 23 patients were enrolled in the study. High-flow nasal oxygen therapy was administered with a predefined protocol. Vital signs, Visual Analog Scale for dyspnea, and arterial blood gas parameters were recorded at the beginning under low-flow oxygen support therapy and the 1st, 6th, 12th, and 24th hours of high-flow nasal oxygen therapy. High-flow nasal oxygen therapy duration, intensive care unit length of stay, and intensive care unit, in-hospital, and 60-day mortality were recorded as outcomes and compared according to the presence of pneumonia upon admission. RESULTS: In 12 patients (52.2%), pneumonia was present. High-flow nasal oxygen therapy was applied for a median of 57 hours [49.2-104.5]. Overall decreases were detected in heart rate (P = .001), respiratory rate (P < .001), and Visual Analog Scale for dyspnea (P = .001) during the first 24 hours of the therapy. Although there was an increase in PaCO2 (P = .001), pH increased (P < .001) over time too. No change in partial arterial oxygen pressure (P = .63) and partial arterial oxygen pressure/fraction of inspired oxygen ratio (P = .22) was noted. Nineteen patients (77%) were successfully weaned from high-flow nasal oxygen therapy. While the high-flow nasal oxygen therapy failure rate was 23%, the in-hospital and 60-day mortality rates were 8.6%. Outcomes were not different between patients with and without pneumonia. CONCLUSION: High-flow nasal oxygen therapy was efficient in relieving respiratory distress and well-tolerated with no adverse out- come in severe acute exacerbation of chronic obstructive pulmonary disease patients admitted to the intensive care unit.

8.
Turk Thorac J ; 19(4): 209-215, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30322437

RESUMO

OBJECTIVES: We aimed to obtain information about the characteristics of the ICUs in our country via a point prevalence study. MATERIAL AND METHODS: This cross-sectional study was planned by the Respiratory Failure and Intensive Care Assembly of Turkish Thoracic Society. A questionnaire was prepared and invitations were sent from the association's communication channels to reach the whole country. Data were collected through all participating intensivists between the October 26, 2016 at 08:00 and October 27, 2016 at 08:00. RESULTS: Data were collected from the 67 centers. Overall, 76.1% of the ICUs were managed with a closed system. In total, 35.8% (n=24) of ICUs were levels of care (LOC) 2 and 64.2% (n=43) were LOC 3. The median total numbers of ICU beds, LOC 2, and LOC 3 beds were 12 (8-23), 14 (10-25), and 12 (8-20), respectively. The median number of ventilators was 12 (7-21) and that of ventilators with non-invasive ventilation mode was 11 (6-20). The median numbers of patients per physician during day and night were 3.9 (2.3-8) and 13 (9-23), respectively. The median number of patients per nurse was 2.5 (2-3.1); 88.1% of the nurses were certified by national certification corporation. CONCLUSION: In terms of the number of staff, there is a need for specialist physicians, especially during the night and nurses in our country. It was thought that the number of ICU-certified nurses was comparatively sufficient, yet the target was supposed to be 100% for this rate.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA