Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Clin Virol ; 129: 104479, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32531665

RESUMO

BACKGROUND: Currently, FDA-approved HIV-1 viral load (VL) assays use venipuncture-derived plasma. The Hologic Panther system uses 0.7 mL total volume for the Aptima HIV-1 Quant Assay standard (APT-Quant-std) and dilution (APT-Quant-dil) protocols. However, smaller plasma volumes from fingerstick whole blood (FSB) collected in EDTA-microtainer tubes (MCT) could provide an easier sample collection method for HIV-1 VL testing. OBJECTIVES: To evaluate the performance of the APT-Quant-std compared to the Roche CAP/CTM and Abbott m2000RT VL assays and an alternative APTQuant 1:7 dilution protocol, the latter using 100 µL of MCT-derived plasma from FSB. STUDY DESIGN: Linearity was determined using commercial HIV-1 RNA plasma controls. Dilutions ranging 1.56-2.95 log10 copies/mL were prepared to determine the APT-Quant-dil Limit of Quantitation (LOQ) using Probit analysis. Specificity of APT-Quant-std was calculated using 326 HIVnegative samples. To evaluate agreement, 329 plasma specimens were tested with APT-Quant-std, CAP/CTM, and m2000RT. Forty-seven matched venipuncture and MCT-derived plasma specimens were tested with APT-Quant-std and APT-Quant-dil. RESULTS: Among the RNA controls, specificity was 99.69 % for APT-Quant-std. The R2 values were 0.988 (APT-Quant-std/CAP/CTM), 0.980 (APT-Quant-std/ m2000RT), and 0.997 (APT-Quant-std/APT-Quant-dil). The APT-Quant-dil LOQ was estimated at 2.7 log10 copies/mL (500 copies/mL) (95 %CI 2.62-2.87). At 2.3 log10 copies/mL (200 copies/mL), the overall agreement was 91.0 % for APT-Quant-std/CAP/CTM, 85.7 % for APT-Quant-std/m2000RT, and 82.9 % for APT-Quant-std/APT-Quant-dil. Quantified APT-Quant-std results were on average 0.2 log10 copies/mL higher than CAP/CTM and m2000RT and 0.14 log10 copies/mL higher than APT-Quant-dil. CONCLUSION: APT-Quant showed similar performance compared to the CAP/CTM and m2000RT assays and remains sensitive and accurate using the dilution protocol.


Assuntos
Infecções por HIV , HIV-1 , Infecções por HIV/diagnóstico , HIV-1/genética , Humanos , RNA , RNA Viral/genética , Sensibilidade e Especificidade , Carga Viral
2.
J Clin Virol ; 91: 84-89, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28366544

RESUMO

OBJECTIVE: FDA-approved antigen/antibody combo and HIV-1/2 differentiation supplemental tests do not have claims for dried blood spot (DBS) use. We compared two DBS-modified protocols, the Bio-Rad GS HIV Combo Ag/Ab (BRC) EIA and Geenius™ HIV-1/2 (Geenius) Supplemental Assay, to plasma protocols and evaluated them in the CDC/APHL HIV diagnostic algorithm. METHODS: BRC-DBS p24 analytical sensitivity was calculated from serial dilutions of p24. DBS specimens included 11 HIV-1 seroconverters, 151 HIV-1-positive individuals, including 20 on antiretroviral therapy, 31 HIV-2-positive and one HIV-1/HIV-2-positive individuals. BRC-reactive specimens were tested with Geenius using the same DBS eluate. Matched plasma specimens were tested with BRC, an IgG/IgM immunoassay and Geenius. DBS and plasma results were compared using the McNemar's test. A DBS-algorithm applied to 348 DBS from high-risk individuals who participated in surveillance was compared to HIV status based on local testing algorithms. RESULTS: BRC-DBS detects p24 at a concentration 18 times higher than in plasma. In seroconverters, BRC-DBS detected more infections than the IgG/IgM immunoassay in plasma (p=0.0133), but fewer infections than BRC-plasma (p=0.0133). In addition, the BRC/Geenius-plasma algorithm identified more HIV-1 infections than the BRC/Geenius-DBS algorithm (p=0.0455). The DBS protocols correctly identified HIV status for established HIV-1 infections, including those on therapy, HIV-2 infections, and surveillance specimens. CONCLUSIONS: The DBS protocols exhibited promising performance and allowed rapid supplemental testing. Although the DBS algorithm missed some early infections, it showed similar results when applied to specimens from a high-risk population. Implementation of a DBS algorithm would benefit testing programs without capacity for venipuncture.


Assuntos
Teste em Amostras de Sangue Seco , Infecções por HIV/diagnóstico , Técnicas Imunoenzimáticas , Sorodiagnóstico da AIDS , Algoritmos , Teste em Amostras de Sangue Seco/instrumentação , Teste em Amostras de Sangue Seco/métodos , Monitoramento Epidemiológico , Anticorpos Anti-HIV/sangue , Antígenos HIV/sangue , Antígenos HIV/imunologia , Infecções por HIV/sangue , Infecções por HIV/imunologia , Infecções por HIV/virologia , HIV-1/imunologia , HIV-2/imunologia , Humanos , RNA Viral/sangue , Kit de Reagentes para Diagnóstico , Fatores de Risco , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA