RESUMO
OBJECTIVES: Recently, patients with certain legacy cochlear implants (CIs) have sought out reimplantation to enjoy the benefits offered by newer processor technology. This decision can be difficult, especially when the individual relies exclusively on the device for communication and scores at the ceiling of performance metrics. To date, most outcome data is derived from reimplantation of a non-functioning CI-a relatively easy decision. The aim of this study is to report hearing outcomes following reimplantation of legacy implants to guide surgeons and patients approaching this high-stakes clinical situation. PATIENTS AND INTERVENTION: Four patients implanted with Advanced Bionics Clarion C1 devices over 20 years ago underwent reimplantation. RESULTS: Three reimplanted patients demonstrated a maintenance or improvement in their audiometric performance with one patient experiencing only a 5 % decrease in AzBioQ score. Each patient expressed satisfaction with the expansion of technological capabilities including improved battery life, and device connectivity. There were no failed reimplantations or other adverse effects. CONCLUSIONS: Reimplantation of a functioning legacy CI result in stability or improvement in auditory performance. All individuals in this series report that they enjoy the new connectivity and programming technologies. As the rate advancement in CI technology continues to increase and newer device architectures emerge, these data will help to inform the decision to reimplant functioning devices.
Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Resultado do Tratamento , Implante Coclear/métodos , Reimplante/métodos , Reoperação , Adulto , Idoso , Audição , Satisfação do Paciente , AudiometriaRESUMO
OBJECTIVE: To utilize sidestream dark field video microscopic technology to evaluate the endothelium in a canine hemorrhagic shock and resuscitation model. METHODS: 6 purpose-bred adult dogs were anesthetized, instrumented, and subjected to hemorrhagic shock from September 2021 through June 2022. Each dog was resuscitated with 5 resuscitation strategies in an experimental crossover design study: (1) lactated Ringer's solution (LRS) and hydroxyethyl starch (HES) solution; (2) canine chilled whole blood (CWB); (3) canine fresh frozen plasma (FFP) and packed RBCs (pRBC); (4) canine freeze-dried plasma (FDP) and hemoglobin-based oxygen carrier (HBOC); or (5) HBOC/FDP and canine lyophilized platelets. Sidestream dark field video microscopic evaluation was performed at 5 time points: commencement, after hemorrhage, after shock, after resuscitation (T135), and conclusion (T180). RESULTS: There was a significant difference between the perfused boundary region (PBR) measurements when comparing the LRS/HES resuscitation arm to the CWB and FFP/pRBC resuscitation arms at T180. A significant difference in PBR was appreciated in the LRS/HES arm at T135 and T180 compared to its baseline. No other significant differences in PBR were appreciated when resuscitation arms were compared longitudinally or to each other. CONCLUSIONS: Shelf-stable blood products preserved the endothelial glycocalyx similarly to CWB and pRBC/FFP as evaluated by sidestream dark field video microscopy. Lactated Ringer and HES solutions did not adequately preserve the endothelial glycocalyx compared to CWB and pRBC/FFP. CLINICAL RELEVANCE: Shelf-stable blood products are a viable option to preserve the endothelial glycocalyx when used during hemorrhagic resuscitation in dogs.
RESUMO
Hemorrhagic shock and subsequent resuscitation can cause significant dysregulation of critical systems, including the vascular endothelium. Following hemorrhage, the endothelial lining (glycocalyx) can shed, causing release of glycocalyx components, endothelial activation, and systemic inflammation. A canine model of hemorrhagic shock was used to evaluate five resuscitation fluids, including Lactated Ringers+Hetastarch, Whole Blood (WB), Fresh Frozen Plasma+packed Red Blood Cells (FFP+pRBC), and two hemoglobin-based oxygen carrier (HBOC) fluids, for their impact on glycocalyx shedding. Under anesthesia, purpose-bred adult canines were instrumented and subjected to a controlled hemorrhage with blood being drawn until a mean arterial pressure of <50â¯mmHg was reached or 40â¯% of the estimated blood volume was removed. Canines were left in shock for 45â¯mins before being resuscitated with one of the resuscitation fluids over 30â¯mins. Following resuscitation, the dogs were monitored up to 2 weeks. Following an additional 3-4 weeks for washout, the canines repeated the protocol, undergoing each resuscitation fluid individually. Blood samples were collected during each round at various timepoints for serum isolation, which was used for detection of glycocalyx biomarker. Comparison of baseline and post-hemorrhage alone showed a significant reduction in serum protein (p<0.0001), heparan sulfate (p<0.001), and syndecan-1 (p<0.0001) concentrations, and a significant increase in hyaluronan (p<0.0001) concentration. Intercomparisons of resuscitation fluids indicated minimal differences in glycocalyx markers over time. Comparisons within each fluid showed dynamic responses in glycocalyx biomarkers over time. Relative to individual baselines, syndecan-1 was significantly reduced after resuscitation in most cases (p<0.0001), excluding WB and FFP+pRBC. In all cases, VE-cadherin was significantly elevated at 24â¯hr compared to baseline (p<0.001). Hyaluronan was significantly elevated by 3â¯hr in all cases (p<0.01), except for HBOC fluids. Total glycosaminoglycans were significantly reduced only at 3â¯hr (p<0.001) for non-HBOC fluids. Similarly, heparan sulfate was significantly reduced with all fluids between resuscitation and 24â¯hr (p<0.01), except WB. The temporal changes in canine glycocalyx biomarkers were atypical of hemorrhage response in other species. This suggests that the hemorrhage lacked severity and/or typical glycocalyx biomarkers do not reflect the canine endothelium compared to other species. Further research is needed to characterize the canine endothelium and the response to resuscitation fluids.
Assuntos
Doenças do Cão , Hidratação , Glicocálix , Ressuscitação , Choque Hemorrágico , Animais , Cães , Glicocálix/metabolismo , Ressuscitação/veterinária , Ressuscitação/métodos , Choque Hemorrágico/veterinária , Choque Hemorrágico/terapia , Hidratação/veterinária , Doenças do Cão/terapia , Masculino , Feminino , Modelos Animais de Doenças , Biomarcadores/sangue , Sindecana-1/metabolismoRESUMO
BACKGROUND: Treatment of severe hemorrhagic shock typically involves hemostatic resuscitation with blood products. However, logistical constraints often hamper the wide distribution of commonly used blood products like whole blood. Shelf-stable blood products and blood substitutes are poised to be able to effectively resuscitate individuals in hemorrhagic shock when more conventional blood products are not readily available. METHODS: Purpose-bred adult dogs (n = 6) were anesthetized, instrumented, and subjected to hemorrhagic shock (mean arterial pressure <50 mm Hg or 40% blood volume loss). Then each dog was resuscitated with one of five resuscitation products: (1) lactated ringers solution and hetastarch (LRS/Heta), (2) canine chilled whole blood (CWB), (3) fresh frozen plasma (FFP) and packed red blood cells (pRBC), (4) canine freeze-dried plasma (FDP) and hemoglobin-based oxygen carrier (HBOC), or (5) HBOC/FDP and canine lyophilized platelets (LyoPLT). Each dog was allowed to recover after the hemorrhage resuscitation event and was then subjected to another hemorrhage event and resuscitated with a different product until each dog was resuscitated with each product. RESULTS: At the time when animals were determined to be out of shock as defined by a shock index <1, mean arterial pressure (mmHg) values (mean ± standard error) were higher for FFP/pRBC (n = 5, 83.7 ± 4.5) and FDP/HBOC+LyoPLT (n = 4, 87.8 ± 2.1) as compared with WB (n = 4, 66.0 ± 13.1). A transient increase in creatinine was seen in dogs resuscitated with HBOC and FDP. Albumin and base excess increased in dogs resuscitated with HBOC and FDP products compared with LRS/heta and CWB ( p < 0.01). CONCLUSION: Combinations of shelf-stable blood products compared favorably to canine CWB for resolution of shock. Further research is needed to ascertain the reliability and efficacy of these shelf-stable combinations of products in other models of hemorrhage that include a component of tissue damage as well as naturally occurring trauma.