Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Opt Express ; 30(5): 6768-6777, 2022 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-35299455

RESUMO

We present a Raman distributed temperature sensor based on standard telecom single mode fibers and efficient polarization-independent superconducting nanowire single photon detectors. Our device shows 3 cm and 1.5 °C resolution on a 5 m fiber upon one minute integration. We show that spatial resolution is limited by the laser pulse width and not by the detection system. Moreover, for long fibers the minimum distance for a measurable temperature step change increases of around 4 cm per km length, because of chromatic dispersion at the Stokes and Anti-Stokes wavelengths. Temperature resolution is mainly affected by the drop in the laser repetition rate when long fibers are tested. On a 500 m fiber, a trade-off of 10 cm and 8 °C resolution is achieved with 3 minutes integration. Fiber-based distributed temperature sensing, combining centimetric spatial resolution with hundreds of meters sensing range, could pave the way for a new kind of applications, such as 2D and 3D temperature mapping of complex electronic devices, particles detectors, cryogenic and aerospace instrumentation.

2.
Opt Lett ; 47(11): 2618-2621, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35648888

RESUMO

Optical projection tomography (OPT) is a powerful tool for three-dimensional (3D) imaging of mesoscopic samples. While it is able to achieve resolution of a few tens of microns over a sample volume of several cubic centimeters, the reconstructed images often suffer from artifacts caused by inaccurate calibration. In this work, we focus on the refractive-index mismatch between the sample and the surrounding medium. We derive a 3D cone-beam forward model of OPT that approximates the effect of refractive-index mismatch. We then implement a fast and efficient reconstruction method to correct for the induced seagull-shaped artifacts on experimental images of fluorescent beads.


Assuntos
Artefatos , Tomografia Óptica , Algoritmos , Refratometria , Tomografia Óptica/métodos
3.
Opt Lett ; 43(8): 1782-1785, 2018 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-29652363

RESUMO

Extended-focus optical coherence tomography (xf-OCT) is a variant of optical coherence tomography (OCT) wherein the illumination and/or detection modes are engineered to provide a constant diffractionless lateral resolution over an extended depth of field (typically 3 to 10× the Rayleigh range). xf-OCT systems operating at 800 nm have been devised and used in the past to image brain structures at high-resolution in vivo, but are limited to ∼500 µm in penetration depth due to their short illumination wavelength. Here we present an xf-OCT system optimized to an image deeper within the cortex by using a longer illumination central wavelength of 1310 nm. The system offers a lateral resolution of 3 and 6.5 µm, over a depth of 900 µm and >1.5 mm using a 10× and 5× objective, respectively, in air. We characterize the system's resolution using microbeads embedded in PDMS and demonstrate its capabilities by imaging the cortical structure and microvasculature in anesthetized mice to a depth of ∼0.8 mm. Finally, we illustrate the difference in penetration depths obtainable with the new system and an xf-OCT system operating at 800 nm.


Assuntos
Córtex Cerebral/irrigação sanguínea , Córtex Cerebral/diagnóstico por imagem , Microvasos/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Animais , Circulação Cerebrovascular , Imageamento Tridimensional , Camundongos , Camundongos Endogâmicos C57BL
4.
Opt Express ; 25(24): 30807-30819, 2017 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-29221107

RESUMO

Optical coherence microscopy (OCM) is an interferometric technique providing 3D images of biological samples with micrometric resolution and penetration depth of several hundreds of micrometers. OCM differs from optical coherence tomography (OCT) in that it uses a high numerical aperture (NA) objective to achieve high lateral resolution. However, the high NA also reduces the depth-of-field (DOF), scaling with 1/NA2. Interferometric synthetic aperture microscopy (ISAM) is a computed imaging technique providing a solution to this trade-off between resolution and DOF. An alternative hardware method to achieve an extended DOF is to use a non-Gaussian illumination. Extended focus OCM (xfOCM) uses a Bessel beam to obtain a narrow and extended illumination volume. xfOCM detects back-scattered light using a Gaussian mode in order to maintain good sensitivity. However, the Gaussian detection mode limits the DOF. In this work, we present extended ISAM (xISAM), a method combining the benefits of both ISAM and xfOCM. xISAM uses the 3D coherent transfer function (CTF) to generalize the ISAM algorithm to different system configurations. We demonstrate xISAM both on simulated and experimental data, showing that xISAM attains a combination of high transverse resolution and extended DOF which has so far been unobtainable through conventional ISAM or xfOCM individually.

5.
Diabetologia ; 59(3): 550-9, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26613896

RESUMO

AIMS/HYPOTHESIS: It is generally accepted that structural and functional quantitative imaging of individual islets would be beneficial to elucidate the pathogenesis of type 1 diabetes. We here introduce functional optical coherence imaging (FOCI) for fast, label-free monitoring of beta cell destruction and associated alterations of islet vascularisation. METHODS: NOD mouse and human islets transplanted into the anterior chamber of the eye (ACE) were imaged with FOCI, in which the optical contrast of FOCI is based on intrinsic variations of the index of refraction resulting in a faster tomographic acquisition. In addition, the phase sensitivity allows simultaneous label-free acquisition of vascularisation. RESULTS: We demonstrate that FOCI allows longitudinal quantification of progressive autoimmune insulitis, including the three-dimensional quantification of beta cell volume, inflammation and vascularisation. The substantially increased backscattering of islets is dominated by the insulin-zinc nanocrystals in the beta cell granules. This translates into a high specificity for the functional beta cell volume of islets. Applying FOCI to a spontaneous mouse model of type 1 diabetes, we quantify the modifications of the pancreatic microvasculature accompanying the progression of diabetes and reveal a strong correlation between increasing insulitis and density of the vascular network of the islet. CONCLUSIONS/INTERPRETATION: FOCI provides a novel imaging technique for investigating functional and structural diabetes-induced alterations of the islets. The label-free detection of beta cell volume and infiltration together with vascularisation offers a unique extension to study ACE-transplanted human islets. These results are contributing to a deeper understanding of human islet transplant rejection and label-free in vivo monitoring of drug efficacy.


Assuntos
Diabetes Mellitus Tipo 1/patologia , Animais , Modelos Animais de Doenças , Genótipo , Humanos , Células Secretoras de Insulina/patologia , Ilhotas Pancreáticas/patologia , Transplante das Ilhotas Pancreáticas , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos NOD , Camundongos Knockout
6.
Commun Biol ; 6(1): 352, 2023 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-37002381

RESUMO

The limitations of 2D microscopy constrain our ability to observe and understand tissue-wide networks that are, by nature, 3-dimensional. Optical projection tomography (OPT) enables the acquisition of large volumes (ranging from micrometres to centimetres) in various tissues. We present a multi-modal workflow for the characterization of both structural and quantitative parameters of the mouse small intestine. As proof of principle, we evidence its applicability for imaging the mouse intestinal immune compartment and surrounding mucosal structures. We quantify the volumetric size and spatial distribution of Isolated Lymphoid Follicles (ILFs) and quantify the density of villi throughout centimetre-long segments of intestine. Furthermore, we exhibit the age and microbiota dependence for ILF development, and leverage a technique that we call reverse-OPT for identifying and homing in on regions of interest. Several quantification capabilities are displayed, including villous density in the autofluorescent channel and the size and spatial distribution of the signal of interest at millimetre-scale volumes. The concatenation of 3D imaging with reverse-OPT and high-resolution 2D imaging allows accurate localisation of ROIs and adds value to interpretations made in 3D. Importantly, OPT may be used to identify sparsely-distributed regions of interest in large volumes whilst retaining compatibility with high-resolution microscopy modalities, including confocal microscopy. We believe this pipeline to be approachable for a wide-range of specialties, and to provide a new method for characterisation of the mouse intestinal immune compartment.


Assuntos
Imageamento Tridimensional , Tomografia Óptica , Camundongos , Animais , Imageamento Tridimensional/métodos , Intestino Delgado/diagnóstico por imagem , Intestinos , Tomografia Óptica/métodos , Microscopia Confocal
7.
Front Neurosci ; 17: 1189615, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37397462

RESUMO

Traumatic brain injury (TBI) is caused by a wide range of physical events and can induce an even larger spectrum of short- to long-term pathophysiologies. Neuroscientists have relied on animal models to understand the relationship between mechanical damages and functional alterations of neural cells. These in vivo and animal-based in vitro models represent important approaches to mimic traumas on whole brains or organized brain structures but are not fully representative of pathologies occurring after traumas on human brain parenchyma. To overcome these limitations and to establish a more accurate and comprehensive model of human TBI, we engineered an in vitro platform to induce injuries via the controlled projection of a small drop of liquid onto a 3D neural tissue engineered from human iPS cells. With this platform, biological mechanisms involved in neural cellular injury are recorded through electrophysiology measurements, quantification of biomarkers released, and two imaging methods [confocal laser scanning microscope (CLSM) and optical projection tomography (OPT)]. The results showed drastic changes in tissue electrophysiological activities and significant releases of glial and neuronal biomarkers. Tissue imaging allowed us to reconstruct the injured area spatially in 3D after staining it with specific nuclear dyes and to determine TBI resulting in cell death. In future experiments, we seek to monitor the effects of TBI-induced injuries over a prolonged time and at a higher temporal resolution to better understand the subtleties of the biomarker release kinetics and the cell recovery phases.

8.
Small ; 8(17): 2752-6, 2012 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-22859385

RESUMO

Potassium niobate nonlinear nanoparticles are used for the first time to monitor the evolution of embryonic stem cells (ESC) by second harmonic microscopy. These particles feature the complete absence of photo-bleaching and unlimited excitation wavelength flexibility. The potential of this approach is made evident for tissue-regeneration studies and applications, by capturing a high-speed movie of ESC-derived cardiomyocytes autonomously beating within a cluster. Time-resolved data are analyzed to retrieve 3D information of the contraction pattern at the cellular level.


Assuntos
Células-Tronco Embrionárias/citologia , Miocárdio/citologia , Nanotecnologia , Animais , Camundongos
9.
Sci Rep ; 12(1): 3464, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-35236913

RESUMO

The growth of data throughput in optical microscopy has triggered the extensive use of supervised learning (SL) models on compressed datasets for automated analysis. Investigating the effects of image compression on SL predictions is therefore pivotal to assess their reliability, especially for clinical use. We quantify the statistical distortions induced by compression through the comparison of predictions on compressed data to the raw predictive uncertainty, numerically estimated from the raw noise statistics measured via sensor calibration. Predictions on cell segmentation parameters are altered by up to 15% and more than 10 standard deviations after 16-to-8 bits pixel depth reduction and 10:1 JPEG compression. JPEG formats with higher compression ratios show significantly larger distortions. Interestingly, a recent metrologically accurate algorithm, offering up to 10:1 compression ratio, provides a prediction spread equivalent to that stemming from raw noise. The method described here allows to set a lower bound to the predictive uncertainty of a SL task and can be generalized to determine the statistical distortions originated from a variety of processing pipelines in AI-assisted fields.


Assuntos
Compressão de Dados , Algoritmos , Compressão de Dados/métodos , Processamento de Imagem Assistida por Computador/métodos , Microscopia , Reprodutibilidade dos Testes , Aprendizado de Máquina Supervisionado
10.
Opt Express ; 19(8): 7580-6, 2011 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-21503066

RESUMO

We describe the performance of a reflective pulse-shaper based on a Micro-ElectroMechanical System (MEMS) linear mirror array. It represents a substantial upgrade of a preceding release [Opt. Lett. 35, 3102 (2010)] as it allows simultaneous piston and tilt mirror motion, allowing both phase- and binary amplitude-shaping with no wavelength restriction. Moreover, we show how the combination of in-axis and tilt movement can be used for active correction of spatial chirp.

11.
Chimia (Aarau) ; 65(5): 346-9, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21744691

RESUMO

The activity of the GAP-Biophotonics research group at the University of Geneva in the field of coherent control for discriminating similar biomolecules, such as flavins, proteins and DNA bases, is presented and future developments are discussed.


Assuntos
DNA/química , Flavinas/química , Proteínas/química , Estrutura Molecular , Fotometria/instrumentação
12.
Biomed Opt Express ; 12(6): 3619-3629, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34221683

RESUMO

Optical projection tomography (OPT) is a powerful tool for three-dimensional imaging of mesoscopic biological samples with great use for biomedical phenotyping studies. We present a fluorescent OPT platform that enables direct visualization of biological specimens and processes at a centimeter scale with high spatial resolution, as well as fast data throughput and reconstruction. We demonstrate nearly isotropic sub-28 µm resolution over more than 60 mm3 after reconstruction of a single acquisition. Our setup is optimized for imaging the mouse gut at multiple wavelengths. Thanks to a new sample preparation protocol specifically developed for gut specimens, we can observe the spatial arrangement of the intestinal villi and the vasculature network of a 3-cm long healthy mouse gut. Besides the blood vessel network surrounding the gastrointestinal tract, we observe traces of vasculature at the villi ends close to the lumen. The combination of rapid acquisition and a large field of view with high spatial resolution in 3D mesoscopic imaging holds an invaluable potential for gastrointestinal pathology research.

13.
Opt Express ; 18(22): 23218-25, 2010 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-21164663

RESUMO

We demonstrate the excitation of second harmonic radiation of noncentrosymmetric nanoparticles dispersed on a planar optical waveguide by the evanescent field of the guided mode. Polarization imaging reveals information on the orientation of the crystal axis of individual nanoparticles. Interference patterns generated from adjacent particles at the second harmonic frequency are--to the authors knowledge--observed for the first time. The actual form of the interference pattern is explained on the basis of a dipole radiation model, taking into account the nanoparticles' orientation, surface effects, and the characteristics of the imaging optics.

14.
Opt Lett ; 35(18): 3102-4, 2010 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-20847792

RESUMO

We demonstrate the capabilities of a new optical microelectromechanical systems device that we specifically developed for broadband femtosecond pulse shaping. It consists of a one-dimensional array of 100 independently addressable, high-aspect-ratio micromirrors with up to 3 µm stroke. We apply linear and quadratic phase modulations demonstrating the temporal compression of 800 and 400 nm pulses. Because of the device's surface flatness, stroke, and stroke resolution, phase shaping over an unprecedented bandwidth is attainable.


Assuntos
Raios Infravermelhos , Dispositivos Ópticos , Raios Ultravioleta , Cor , Fatores de Tempo
15.
Opt Express ; 17(17): 15342-9, 2009 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-19688012

RESUMO

We demonstrate the possibility to excite second-harmonic (SH) active Fe(IO(3))(3) nanocrystals with two distinct laser sources at 800 and 1550 nm, and we show, by a complementary experimental and numerical study, how the wavelength flexibility inherent to non-phase-matched SH nanoparticles can be efficiently exploited to increase imaging penetration depth of markers embedded in biological samples.


Assuntos
Microscopia de Fluorescência por Excitação Multifotônica/métodos , Nanotecnologia/métodos , Animais , Simulação por Computador , Ferro/química , Lasers , Camundongos , Microscopia/métodos , Método de Monte Carlo , Nanopartículas/química , Nefelometria e Turbidimetria/métodos , Óptica e Fotônica , Fótons , Poliestirenos/química
16.
Opt Express ; 16(14): 10405-11, 2008 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-18607452

RESUMO

We present a technique to characterize ultrashort pulses at the focal plane of a high numerical aperture objective with unprecedented spatial resolution, by performing a FROG measurement with a single nanocrystal as nonlinear medium. This approach can be extended to develop novel phase-sensitive techniques in laser scanning microscopy, probing the microscopic environment by monitoring phase and amplitude distortions of femtosecond laser pulses.


Assuntos
Lasers , Microscopia Confocal/instrumentação , Microscopia Confocal/métodos , Microscopia de Fluorescência por Excitação Multifotônica/instrumentação , Microscopia de Fluorescência por Excitação Multifotônica/métodos , Óptica e Fotônica/instrumentação , Fótons , Membrana Celular/patologia , Desenho de Equipamento , Concentração de Íons de Hidrogênio , Modelos Estatísticos , Propriedades de Superfície , Fatores de Tempo
17.
Sci Rep ; 7: 43275, 2017 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-28230188

RESUMO

We present a 3D time-lapse imaging method for monitoring mitochondrial dynamics in living HeLa cells based on photothermal optical coherence microscopy and using novel surface functionalization of gold nanoparticles. The biocompatible protein-based biopolymer coating contains multiple functional groups which impart better cellular uptake and mitochondria targeting efficiency. The high stability of the gold nanoparticles allows continuous imaging over an extended time up to 3000 seconds without significant cell damage. By combining temporal autocorrelation analysis with a classical diffusion model, we quantify mitochondrial dynamics and cast these results into 3D maps showing the heterogeneity of diffusion parameters across the whole cell volume.


Assuntos
Imageamento Tridimensional/métodos , Microscopia/métodos , Dinâmica Mitocondrial , Imagem com Lapso de Tempo/métodos , Células HeLa , Humanos , Coloração e Rotulagem/métodos
18.
Biomed Opt Express ; 8(1): 1-15, 2017 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-28101397

RESUMO

Functional magnetic resonance (fMRI) imaging is the current gold-standard in neuroimaging. fMRI exploits local changes in blood oxygenation to map neuronal activity over the entire brain. However, its spatial resolution is currently limited to a few hundreds of microns. Here we use extended-focus optical coherence microscopy (xfOCM) to quantitatively measure changes in blood flow velocity during functional hyperaemia at high spatio-temporal resolution in the somatosensory cortex of mice. As optical coherence microscopy acquires hundreds of depth slices simultaneously, blood flow velocity measurements can be performed over several vessels in parallel. We present the proof-of-principle of an optimised statistical parametric mapping framework to analyse quantitative blood flow timetraces acquired with xfOCM using the general linear model. We demonstrate the feasibility of generating maps of cortical hemodynamic reactivity at the capillary level with optical coherence microscopy. To validate our method, we exploited 3 stimulation paradigms, covering different temporal dynamics and stimulated limbs, and demonstrated its repeatability over 2 trials, separated by a week.

19.
Biomed Opt Express ; 8(7): 3343-3359, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28717571

RESUMO

We present a novel extended-focus optical coherence microscope (OCM) attaining 0.7 µm axial and 0.4 µm lateral resolution maintained over a depth of 40 µm, while preserving the advantages of Fourier domain OCM. Our system uses an ultra-broad spectrum from a supercontinuum laser source. As the spectrum spans from near-infrared to visible wavelengths (240 nm in bandwidth), we call the system visOCM. The combination of such a broad spectrum with a high-NA objective creates an almost isotropic 3D submicron resolution. We analyze the imaging performance of visOCM on microbead samples and demonstrate its image quality on cell cultures and ex-vivo brain tissue of both healthy and alzheimeric mice. In addition to neuronal cell bodies, fibers and plaques, visOCM imaging of brain tissue reveals fine vascular structures and sub-cellular features through its high spatial resolution. Sub-cellular structures were also observed in live cells and were further revealed through a protocol traditionally used for OCT angiography.

20.
Biomater Sci ; 5(5): 966-971, 2017 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-28282092

RESUMO

We report a bioinspired multifunctional albumin derived polypeptide coating comprising grafted poly(ethylene oxide) chains, multiple copies of the HIV TAT derived peptide enabling cellular uptake as well as mitochondria targeting triphenyl-phosphonium (TPP) groups. Exploring these polypeptide copolymers for passivating gold nanoparticles (Au NPs) yielded (i) NIR-emitting markers in confocal microscopy and (ii) photo-thermal active probes in optical coherence microscopy. We demonstrate the great potential of such multifunctional protein-derived biopolymer coatings for efficiently directing Au NP into cells and to subcellular targets to ultimately probe important cellular processes such as mitochondria dynamics and vitality inside living cells.


Assuntos
Corantes Fluorescentes/química , Ouro/química , Nanopartículas Metálicas/química , Mitocôndrias/ultraestrutura , Peptídeos/química , Albumina Sérica/química , Produtos do Gene tat do Vírus da Imunodeficiência Humana/química , Células HeLa , Humanos , Raios Infravermelhos , Nanopartículas Metálicas/ultraestrutura , Microscopia Confocal/métodos , Compostos Organofosforados/química , Polietilenoglicóis/química , Temperatura , Compostos de Terfenil/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA