RESUMO
INTRODUCTION: Pancreatic cancer (PC) surveillance of high-risk individuals (HRI) is becoming more common worldwide, aiming at anticipating PC diagnosis at a preclinical stage. In 2015, the Italian Registry of Families at Risk of Pancreatic Cancer was created. We aimed to assess the prevalence and incidence of pancreatic findings, oncological outcomes, and harms 7 years after the Italian Registry of Families at Risk of Pancreatic Cancer inception, focusing on individuals with at least a 3-year follow-up or developing events before. METHODS: HRI (subjects with a family history or mutation carriers with/without a family history were enrolled in 18 centers). They underwent annual magnetic resonance with cholangiopancreatography or endoscopic ultrasound (NCT04095195). RESULTS: During the study period (June 2015-September 2022), 679 individuals were enrolled. Of these, 524 (77.2%) underwent at least baseline imaging, and 156 (29.8%) with at least a 3-year follow-up or pancreatic malignancy/premalignancy-related events, and represented the study population. The median age was 51 (interquartile range 16) years. Familial PC cases accounted for 81.4% of HRI and individuals with pathogenic variant for 18.6%. Malignant (n = 8) and premalignant (1 PanIN3) lesions were found in 9 individuals. Five of these 8 cases occurred in pathogenic variant carriers, 4 in familial PC cases (2 tested negative at germline testing and 2 others were not tested). Three of the 8 PC were stage I. Five of the 8 PC were resectable, 3 Stage I, all advanced cases being prevalent. The 1-, 2-, and 3-year cumulative hazard of PC was 1.7%, 2.5%, and 3%, respectively. Median overall and disease-free survival of patients with resected PC were 18 and 12 months (95% CI not computable). Considering HRI who underwent baseline imaging, 6 pancreatic neuroendocrine neoplasms (1 resected) and 1 low-yield surgery (low-grade mixed-intraductal papillary mucinous neoplasm) were also reported. DISCUSSION: PC surveillance in a fully public health care system is feasible and safe, and leads to early PC or premalignant lesions diagnoses, mostly at baseline but also over time.
Assuntos
Carcinoma Ductal Pancreático , Carcinoma , Neoplasias Pancreáticas , Humanos , Adolescente , Estudos Prospectivos , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/epidemiologia , Pâncreas/patologia , Imageamento por Ressonância Magnética , Carcinoma Ductal Pancreático/patologiaRESUMO
BACKGROUND AND AIMS: Self-expandable metal stents (SEMSs) are standardly used for distal malignant biliary obstruction (dMBO). Although data suggest that covered versus uncovered SEMSs increase the time to recurrent biliary obstruction (TRBO), no data are available for fully covered (FC) versus partially covered (PC) designs. METHODS: PubMed, Scopus, and Cochrane databases were screened up to January 2023 for studies concerning dMBO treated by an FC- or PC-SEMS and describing adverse events (AEs), recurrences, or TRBO for specific design subpopulations. Pooled proportions or means were calculated using a random-effects model. Several subanalyses were preplanned, including a subanalysis restricted to prospective studies and unresectable diseases. Heterogeneity and publication bias were explored. Standardized differences (d-values) were calculated between groups. RESULTS: From 1290 records, 62 studies (3327 using FC-SEMSs and 2322 using PC-SEMSs) were included. FC- versus PC-SEMSs showed negligible differences in the rate of total AEs (12% vs 9.9%) and all specific AEs, including cholecystitis (2.5% vs 2.6%). In a subanalysis restricted to prospective studies and unresectable diseases, the rate of RBO was comparable between FC-SEMSs (27.3% [95% confidence interval {CI}, 23.7-31.2], I2 = 35.34%) and PC-SEMSs (25.3% [95% CI, 20.2-30.7], I2 = 85.09%), despite small differences (d-values between .186 and .216) in the rate of ingrowth (.5% vs 2.9%) favoring FC-SEMSs and migration (9.8% vs 4.3%) favoring PC-SEMSs. TRBO was shorter for FC-SEMSs (238 days [95% CI, 191-286], I2 = 63.1%) versus PC-SEMSs (369 days [95% CI, 290-449], I2 = 71.9%; d-value = .116). CONCLUSIONS: Despite considerable heterogeneity and small standardized differences, PC-SEMSs consistently exhibited longer TRBO than FC-SEMSs across analyses, without any other differences in AE rates, potentially proposing PC-SEMSs as the standard comparator and TRBO as the primary outcome for future randomized studies on dMBO. (Clinical trial registration number: CRD42023393965.).
Assuntos
Colecistite , Colestase , Stents Metálicos Autoexpansíveis , Humanos , Estudos Prospectivos , Falha de Prótese , Colestase/etiologia , Colestase/cirurgia , Stents , Resultado do Tratamento , Estudos RetrospectivosRESUMO
BACKGROUND: Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is a valid option for EUS-guided biliary drainage that has been increasingly used in the last decade. The aims of this study were to provide a systematic review with meta-analysis and meta-regression of the features and outcomes of this procedure. METHODS: The MEDLINE, Scopus, Web of Science, and Cochrane databases were searched for literature pertinent to EUS-HGS. Meta-analysis of the proportions and meta-regression of potential modifiers of the main outcome measures were applied. The main outcome was technical success; secondary outcomes were clinical success and procedure-related adverse events (AEs). RESULTS: 33 studies, including 1644 patients, were included in the meta-analysis. Malignant biliary obstruction (MBO) was the underlying cause in almost all cases (99.6%); the main indications for EUS-HGS were duodenal/papillary invasion (34.8%), surgically altered anatomy (18.4%), and hilar stenosis (16.0%). The pooled technical success of EUS-HGS was 97.7% (95%CI 96.1%-99.0%; I 2 = 0%), the intention-to-treat clinical success rate was 88.1% (95%CI 84.7%-91.2%; I 2 = 33.9%), and procedure-related AEs occurred in 12.0% (95%CI 9.8%-14.5%; I 2 = 20.4%), with cholangitis/sepsis (2.8%) and bleeding (2.3%) the most frequent. The rate of procedure-related AEs was lower with the use of dedicated stents on univariable meta-regression analysis. Meta-regression showed that technical success and clinical success rates were modified by the centers' experience (>4/year). CONCLUSIONS: EUS-HGS represents an effective and safe procedure for EUS-guided biliary drainage in patients with MBO. Future studies should address the impact of center experience, patient selection, and the use of dedicated stents to improve performance of this technique.
Assuntos
Colestase , Drenagem , Endossonografia , Humanos , Colestase/cirurgia , Colestase/etiologia , Drenagem/métodos , Drenagem/efeitos adversos , Endossonografia/efeitos adversos , Endossonografia/métodos , Gastrostomia/efeitos adversos , Gastrostomia/métodos , Análise de Regressão , Stents , Resultado do Tratamento , Ultrassonografia de Intervenção/efeitos adversos , Ultrassonografia de Intervenção/métodosRESUMO
BACKGROUND: Endoscopic full-thickness resection (EFTR) is an effective and safe technique for nonlifting colorectal lesions. Technical issues or failures with the full-thickness resection device (FTRD) system are reported, but there are no detailed data. The aim of our study was to quantify and classify FTRD technical failures. METHODS: We performed a retrospective study involving 17 Italian centers with experience in advanced resection techniques and the required devices. Each center shared and classified all prospectively collected consecutive failures during colorectal EFTR using the FTRD from 2018 to 2022. The primary outcome was the technical failure rate and their classification; secondary outcomes included subsequent management, clinical success, and complications. RESULTS: Included lesions were mainly recurrent (52â%), with a mean (SD) dimension of 18.4 (7.5) mm. Among 750 EFTRs, failures occurred in 77 patients (35 women; mean [SD] age 69.4 [8.9] years). A classification was proposed: type I, snare noncutting (53â%); type II, clip misdeployment (31â%); and type III, cap misplacement (16â%). Among endoscopic treatments completed, rescue endoscopic mucosal resection was performed in 57 patients (74â%), allowing en bloc and R0 resection in 71â% and 64â%, respectively. The overall adverse event rate was 27.3â%. Pooled estimates for the rates of failure, complications, and rescue endoscopic therapy were similar for low and high volume centers (Pâ=â0.08, Pâ=â0.70, and Pâ=â0.71, respectively). CONCLUSIONS: Colorectal EFTR with the FTRD is a challenging technique with a non-negligible rate of technical failure and complications. Experience in rescue resection techniques and multidisciplinary management are mandatory in this setting.
Assuntos
Neoplasias Colorretais , Ressecção Endoscópica de Mucosa , Humanos , Feminino , Masculino , Idoso , Estudos Retrospectivos , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/patologia , Ressecção Endoscópica de Mucosa/métodos , Ressecção Endoscópica de Mucosa/efeitos adversos , Ressecção Endoscópica de Mucosa/instrumentação , Pessoa de Meia-Idade , Colonoscopia/métodos , Colonoscopia/efeitos adversos , Falha de Tratamento , Itália , Complicações Pós-Operatórias/etiologiaRESUMO
BACKGROUND: Malignant Distal Biliary Obstruction (MBDO) is a common event occurring along the natural history of both pancreatic cancer and cholangiocarcinoma. Epidemiological and biological features make MBDO one of the key elements of the clinical management of patients suffering for of pancreatic cancer or cholangiocarcinoma. The development of dedicated biliary lumen-apposing metal stents (LAMS) is changing the clinical work up of patients with MBDO. i-EUS is an Italian network of clinicians and scientists with a special interest in biliopancreatic endoscopy, EUS in particular. METHODS: The scientific methodology was chosen in line with international guidance and in a fashion similar to those applied by broader scientific associations. PICO questions were elaborated and subsequently voted by a broad panel of experts within a simplified Delphi process. RESULTS AND CONCLUSIONS: The manuscripts describes the results of a consensus conference organized by i-EUS with the aim of providing an evidence based-guidance for the appropriate use of the techniques in patients with MBDO.
Assuntos
Neoplasias dos Ductos Biliares , Colestase , Drenagem , Stents , Humanos , Drenagem/métodos , Colestase/cirurgia , Colestase/etiologia , Colestase/terapia , Neoplasias dos Ductos Biliares/complicações , Neoplasias dos Ductos Biliares/cirurgia , Neoplasias Pancreáticas/complicações , Neoplasias Pancreáticas/cirurgia , Colangiocarcinoma/complicações , Endossonografia/métodos , Itália , Técnica DelphiRESUMO
BACKGROUND: Duodenoscope-related multidrug-resistant organism (MDRO) infections raise concerns. Disposable duodenoscopes have been recently introduced in the market and approved by regulatory agencies with the aim to reduce the risk of endoscopic retrograde cholangiopancreatography (ERCP) associated infections. The aim of this study was to evaluate the outcome of procedures performed with single-use duodenoscopes in patients with clinical indications to single-operator cholangiopancreatoscopy. METHODS: This is a multicenter international, retrospective study combining all patients who underwent complex biliopancreatic interventions using the combination of a single-use duodenoscope and a single-use cholangioscope. The primary outcome was technical success defined as ERCP completion for the intended clinical indication. Secondary outcomes were procedural duration, rate of cross-over to reusable duodenoscope, operator-reported satisfaction score (1 to 10) on performance rating of the single-use duodenoscope, and adverse event (AE) rate. RESULTS: A total of 66 patients (26, 39.4% female) were included in the study. ERCP was categorized according to ASGE ERCP grading system as 47 (71.2%) grade 3 and 19 (28.8%) grade 4. The technical success rate was 98.5% (65/66). Procedural duration was 64 (interquartile range 15-189) min, cross-over rate to reusable duodenoscope was 1/66 (1.5%). The satisfaction score of the single-use duodenoscope classified by the operators was 8.6 ± 1.3 points. Four patients (6.1%) experienced AEs not directly related to the single-use duodenoscope, namely 2 post-ERCP pancreatitis (PEP), 1 cholangitis and 1 bleeding. CONCLUSIONS: Single-use duodenoscope is effective, reliable and safe even in technically challenging procedures with a non-inferiority to reusable duodenoscope, making these devices a viable alternative to standard reusable equipment.
Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Pancreatite , Humanos , Feminino , Masculino , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Estudos Retrospectivos , Cateterismo , Duodenoscópios/efeitos adversos , Pancreatite/etiologia , Pancreatite/prevenção & controleRESUMO
Background and Objectives: The implementation and monitoring of the European Society of Gastrointestinal Endoscopy (ESGE) performance measures for colonoscopy are suboptimal in clinical practice. Electronic reporting systems may play an important role in data retrieval. We aimed to define the possibility of systematically assessing and monitoring ESGE performance measures for colonoscopy through reporting systems. Materials and Methods: We conducted a survey during a nationwide event on the quality of colonoscopy held in Rome, Italy, in March 2023 by a self-administered questionnaire. Analyses were conducted overall and by workplace setting. Results: The attendance was 93% (M/F 67/26), with equal distribution of age groups, regions and public or private practices. Only about one-third (34%) and 21.5% of participants stated that their reporting system allows them to retrieve all the ESGE performance measures, overall and as automatic retrieval, respectively. Only 66.7% and 10.7% of respondents can systematically report the cecal intubation and the adenoma detection rate, respectively. The analysis according to hospital setting revealed no significant difference for all the items. Conclusions: We found a generalized lack of systematic tracking of performance measures for colonoscopy due to underperforming reporting systems. Our results underline the need to update reporting systems to monitor the quality of endoscopy practice in Italy.
Assuntos
Colonoscopia , Humanos , Colonoscopia/normas , Colonoscopia/estatística & dados numéricos , Inquéritos e Questionários , Masculino , Feminino , Pessoa de Meia-Idade , Itália , Adulto , Idoso , Endoscopia Gastrointestinal/normas , Endoscopia Gastrointestinal/estatística & dados numéricos , Sociedades Médicas , Europa (Continente)RESUMO
Pancreatic fluid collections (PFCs) are well-known complications of acute pancreatitis. The overinfection of these collections leads to a worsening of the prognosis with an increase in the morbidity and mortality rate. The primary strategy for managing infected pancreatic necrosis (IPN) or symptomatic PFCs is a minimally invasive step-up approach, with endosonography-guided (EUS-guided) transmural drainage and debridement as the preferred and less invasive method. Different stents are available to drain PFCs: self-expandable metal stents (SEMSs), double pigtail stents (DPPSs), or lumen-apposing metal stents (LAMSs). In particular, LAMSs are useful when direct endoscopic necrosectomy is needed, as they allow easy access to the necrotic cavity; however, the rate of adverse events is not negligible, and to date, the superiority over DPPSs is still debated. Moreover, the timing for necrosectomy, the drainage technique, and the concurrent medical management are still debated. In this review, we focus attention on indications, timing, techniques, complications, and particularly on aspects that remain under debate concerning the EUS-guided drainage of PFCs.
Assuntos
Endossonografia , Pancreatite Necrosante Aguda , Humanos , Endossonografia/métodos , Doença Aguda , Pancreatite Necrosante Aguda/diagnóstico por imagem , Pancreatite Necrosante Aguda/cirurgia , Pancreatite Necrosante Aguda/etiologia , Stents/efeitos adversos , Drenagem/métodos , Ultrassonografia de Intervenção , Estudos Retrospectivos , Resultado do TratamentoRESUMO
Background and Objectives: Biliary drainage (BD) in patients with surgically altered anatomy (SAA) could be obtained endoscopically with different techniques or with a percutaneous approach. Every endoscopic technique could be challenging and not clearly superior over another. The aim of this survey is to explore which is the standard BD approach in patients with SAA. Materials and Methods: A 34-question online survey was sent to different Italian tertiary and non-tertiary endoscopic centers performing interventional biliopancreatic endoscopy. The core of the survey was focused on the first-line and alternative BD approaches to SAA patients with benign or malignant obstruction. Results: Out of 70 centers, 39 answered the survey (response rate: 56%). Only 48.7% of them declared themselves to be reference centers for endoscopic BD in SAA. The total number of procedures performed per year is usually low, especially in non-tertiary centers; however, they have a low tendency to refer to more experienced centers. In the case of Billroth-II reconstruction, the majority of centers declared that they use a duodenoscope or forward-viewing scope in both benign and malignant diseases as a first approach. However, in the case of failure, the BD approach becomes extremely heterogeneous among centers without any technique prevailing over the others. Interestingly, in the case of Roux-en-Y, a significant proportion of centers declared that they choose the percutaneous approach in both benign (35.1%) and malignant obstruction (32.4%) as a first option. In the case of a previous failed attempt at BD in Roux-en-Y, the subsequent most used approach is the EUS-guided intervention in both benign and malignant indications. Conclusions: This survey shows that the endoscopic BD approach is extremely heterogeneous, especially in patients with Roux-en-Y reconstruction or after ERCP failure in Billroth-II reconstruction. Percutaneous BD is still taken into account by a significant proportion of centers in the case of Roux-en-Y anatomy. The total number of endoscopic BD procedures performed in non-tertiary centers is usually low, but this result does not correspond to an adequate rate of referral to more experienced centers.
Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Drenagem , Humanos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Drenagem/métodos , ItáliaRESUMO
AIM: To highlight correlations existing between incidence and mortality of pancreatic cancer, and health care indicators in 36 European countries. METHODS: The Global Burden of Disease (GBD) and Eurostat databases were queried between 2004 and 2019. Incidence and mortality were age-standardized. From Eurostat, indicators regarding expenditure, hospital beds, medical technology, health personnel, physicians by medical specialty and unmet needs for medical examination were extracted. Correlations between GBD and Eurostat data were analysed through mediation analysis applying clustering for countries. RESULTS: Incidence increased by +0.6% per year (p = 0.001) and mortality by +0.3% (p = 0.001), being increasing for most of the European countries considered. Incidence and mortality were strongly positively correlated (p = 0.001). Higher current health expenditure, expenditure in inpatient curative care, the number of available beds, the number of computed tomography scan, magnetic resonance units, practising medical doctors were all related to higher incidence (p < 0.05), whereas the unmet need for medical examinations was related to lower incidence. When the mediator' effect of incidence was handled, these indicators, together with expenditure on outpatient curative cares, the number of pet scanners and of radiation therapy equipment, were related to lower mortality (p < 0.05). CONCLUSIONS: Health care environment correlates with reported incidence and mortality of pancreatic cancer. This highlights both that ameliorated socio-economic societies suffer from higher incidence but lower mortality, as well as the epidemiological bias originating from countries' diagnostic ability.
Assuntos
Carga Global da Doença , Neoplasias Pancreáticas , Humanos , Incidência , Análise de Mediação , Gastos em Saúde , Saúde Global , Neoplasias Pancreáticas/epidemiologia , Neoplasias Pancreáticas/terapiaRESUMO
BACKGROUND AND AIMS: EUS-guided gallbladder drainage (EUS-GBD) with lumen-apposing metal stents (LAMSs) has been reported as a rescue treatment with encouraging results for the relief of jaundice in patients with distal malignant biliary obstruction (DMBO) and after failure of both ERCP and EUS-guided choledochoduodenostomy. METHODS: This was a multicenter retrospective analysis of all cases of consecutive EUS-GBD with LAMSs used as a rescue treatment for patients with DMBO in 14 Italian centers from June 2015 to June 2020. Primary endpoints were technical and clinical success, whereas the secondary endpoint was the adverse event (AE) rate. RESULTS: Forty-eight patients (52.1% women) with a mean age of 74.3 ± 11.7 years were included in the study. Biliary stricture was related to pancreatic adenocarcinoma (85.4%), duodenal adenocarcinoma (2.1%), cholangiocarcinoma (4.2%), ampullary cancer (2.1%), colon cancer (4.2%), and metastatic breast cancer (2.1%). The mean diameter of the common bile duct was 13.3 ± 2.8 mm. LAMSs were placed transgastrically in 58.3% of cases and transduodenally in 41.7%. Technical success was 100%, whereas clinical success was 81.3%, with a mean total bilirubin reduction after 2 weeks of 66.5%. The mean procedure time was 26.4 minutes, and the mean hospital stay was 9.2 ± 8.2 days. AEs occurred in 5 patients (10.4%): 3 were classified as intraprocedural and 2 were classified as delayed because they occurred after >15 days. When the American Society for Gastrointestinal Endoscopy lexicon was used, 2 AEs were mild and 3 were moderate (2 buried LAMSs). The mean follow-up was 122 days. CONCLUSIONS: Our study shows that EUS-GBD with LAMSs used as a rescue treatment for patients affected by DMBO represents a valuable option in terms of technical and clinical success rates, with an acceptable AE rate. To the best of our knowledge, this is the largest study concerning the use of this procedure. (Clinical trial registration number: NCT03903523.).
Assuntos
Adenocarcinoma , Ampola Hepatopancreática , Colestase , Neoplasias do Ducto Colédoco , Neoplasias Pancreáticas , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Vesícula Biliar , Estudos Retrospectivos , Adenocarcinoma/complicações , Neoplasias Pancreáticas/complicações , Neoplasias do Ducto Colédoco/complicações , Endossonografia/métodos , Stents/efeitos adversos , Colestase/etiologia , Colestase/cirurgia , Drenagem/métodos , Ultrassonografia de Intervenção/efeitos adversos , Resultado do TratamentoRESUMO
BACKGROUND : The advantage of using the macroscopic on-site evaluation (MOSE) technique during endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) performed with 22G Franseen needles has not been investigated. We aimed to compare EUS-FNB with MOSE vs. EUS-FNB performed with three needle passes. METHODS : This randomized trial involved 10 Italian referral centers. Consecutive patients referred for EUS-FNB of pancreatic or nonpancreatic solid lesions were included in the study and randomized to the two groups. MOSE was performed by gross visualization of the collected material by the endoscopists and considered adequate when a white/yellowish aggregate core longer than 10âmm was retrieved. The primary outcome was diagnostic accuracy. Secondary outcomes were specimen adequacy, number of needle passes, and safety. RESULTS : 370 patients with 234 pancreatic lesions (63.2â%) and 136 nonpancreatic lesions (36.8â%) were randomized (190 EUS-FNB with MOSE and 180 with standard EUS-FNB). No statistically significant differences were found between EUS-FNB with MOSE and conventional EUS-FNB in terms of diagnostic accuracy (90.0â% [95â%CI 84.8â%-93.9â%] vs. 87.8â% [95â%CI 82.1â%-92.2â%]; Pâ=â0.49), sample adequacy (93.1â% [95â%CI 88.6â%-96.3â%] vs. 95.5â% [95â%CI 91.4â%-98â%]; Pâ=â0.31), and rate of adverse events (2.6â% vs. 1.1â%; Pâ=â0.28). The median number of passes was significantly lower in the EUS-FNB with MOSE group (1 vs. 3; Pâ<â0.001). CONCLUSIONS : The accuracy of EUS-FNB with MOSE is noninferior to that of EUS-FNB with three needle passes. MOSE reliably assesses sample adequacy and reduces the number of needle passes required to obtain the diagnosis with a 22G Franseen needle.
Assuntos
Neoplasias Pancreáticas , Humanos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Biópsia Guiada por Imagem , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/patologiaRESUMO
OBJECTIVES: A new short device for percutaneous endoscopic cholangioscopy was recently developed. However, feasibility and safety has not yet been evaluated. The aim of this study was to assess clinical success, technical success, and adverse events (AEs). METHODS: This observational multicenter retrospective study included all patients who underwent percutaneous cholangioscopy using a short cholangioscope between 2020 and 2022. The clinical success, defined as the complete duct clearance or obtaining at least one cholangioscopy-guided biopsy, was assessed. The histopathological accuracy, technical success, and the AE rate were also evaluated. RESULTS: Fifty-one patients (60 ± 15 years, 45.1% male) were included. The majority of patients had altered anatomy (n = 40, 78.4%), and biliary stones (n = 34, 66.7%) was the commonest indication. The technique was predominantly wire-guided (n = 44, 86.3%) through a percutaneous sheath (n = 36, 70.6%) following a median interval of 8.5 days from percutaneous drainage. Cholangioscopy-guided electrohydraulic lithotripsy was performed in 29 cases (56.9%), combined with a retrieval basket in eight cases (27.6%). The clinical success was 96.6%, requiring a median of one session (range 1-3). Seventeen patients (33.3%) underwent cholangioscopy-guided biopsies. There were four (7.8%) cholangioscopy-related AEs (cholangitis and peritonitis). Overall, the technical success and AE rates were 100% and 19.6%, respectively, in a median follow-up of 7 months. CONCLUSION: Percutaneous endoscopic cholangioscopy with a new short device is effective and safe, requiring a low number of sessions to achieve duct clearance or accurate histopathological diagnosis.
RESUMO
OBJECTIVES: Repeated endoscopic ultrasound (EUS)-guided tissue acquisition represents the standard practice for solid pancreatic lesions after previous nondiagnostic or inconclusive results. Since data are lacking, we aimed to evaluate the diagnostic performance of repeated EUS fine-needle biopsy (rEUS-FNB) in this setting. The primary outcome was diagnostic accuracy; sample adequacy, sensitivity, specificity, and safety were secondary outcomes. METHODS: Consecutive patients undergoing rEUS-FNB for solid pancreatic lesions at 23 Italian centers from 2019 to 2021 were retrieved. Pathology on the surgical specimen, malignant histology together with ≥6-month follow-up, and benign pathology together with ≥12-month follow-up were adopted as gold standards. RESULTS: Among 462 patients, 56.5% were male, with a median age of 68 (59-75) years, malignancy prevalence 77.0%. Tumor size was 26 (20-35) mm. Second-generation FNB needles were used in 89.6% cases. Diagnostic accuracy, sensitivity, and specificity of rEUS-FNB were 89.2%, 91.4%, and 81.7%, respectively (19 false-negative and 12 false-positive results). On multivariate analysis, rEUS-FNB performed at high-volume centers (odds ratio [OR] 2.12; 95% confidence interval [CI] 1.10-3.17; P = 0.03) and tumor size (OR 1.03; 95% CI 1.00-1.06; P = 0.05) were independently related to diagnostic accuracy. Sample adequacy was 94.2%. Use of second-generation FNB needles (OR 5.42; 95% CI 2.30-12.77; P < 0.001) and tumor size >23 mm (OR 3.04; 95% CI 1.31-7.06; P = 0.009) were independently related to sample adequacy. CONCLUSION: Repeated EUS-FNB allowed optimal diagnostic performance after nondiagnostic or inconclusive results. Patients' referral to high-volume centers improved diagnostic accuracy. The use of second-generation FNB needles significantly improved sample adequacy over standard EUS-FNB needles.
RESUMO
Background and Objectives: Bleeding is one of the most feared and frequent adverse events in the case of EUS-guided drainage of WOPN using lumen-apposing metal stents (LAMSs) and of direct endoscopic necrosectomy (DEN). When it occurs, its management is still controversial. In the last few years, PuraStat, a novel hemostatic peptide gel has been introduced, expanding the toolbox of the endoscopic hemostatic agents. The aim of this case series was to evaluate the safety and efficacy of PuraStat in preventing and controlling bleeding of WOPN drainage using LAMSs. Materials and Methods: This is a multicenter, retrospective pilot study from three high-volume centers in Italy, including all consecutive patients treated with the novel hemostatic peptide gel after LAMSs placement for the drainage of symptomatic WOPN between 2019 and 2022. Results: A total of 10 patients were included. All patients underwent at least one session of DEN. Technical success of PuraStat was achieved in 100% of patients. In seven cases PuraStat was placed for post-DEN bleeding prevention, with one patient experiencing bleeding after DEN. In three cases, on the other hand, PuraStat was placed to manage active bleeding: two cases of oozing were successfully controlled with gel application, and a massive spurting from a retroperitoneal vessel required subsequent angiography. No re-bleeding occurred. No PuraStat-related adverse events were reported. Conclusions: This novel peptide gel could represent a promising hemostatic device, both in preventing and managing active bleeding after EUS-guided drainage of WON. Further prospective studies are needed to confirm its efficacy.
Assuntos
Pancreatite Necrosante Aguda , Humanos , Pancreatite Necrosante Aguda/cirurgia , Pancreatite Necrosante Aguda/etiologia , Estudos Retrospectivos , Projetos Piloto , Stents/efeitos adversos , Hemorragia/etiologia , Drenagem/efeitos adversos , Resultado do Tratamento , Necrose/etiologiaRESUMO
Anastomotic defects are deleterious complications after either oncologic or bariatric surgery, leading to high morbidity and mortality. Besides surgical revision in early stages or instable patients, endoscopic treatment has become the mainstay. To date, many options for endoscopic treatment in this setting exist, including fully covered metal stent placement, endoscopic vacuum therapy (EVT), endoscopic internal drainage with pigtail placement (EID), leak closure with through the scope or over the scope clips, endoluminal suturing, fibrin glue sealing and a combination of all these techniques. Current evidence is mostly based on retrospective single and multicenter studies. No guidelines exist in this important field. Treatment options have to be chosen upon each case individually, taking into account clinical and anatomic criteria, such as timing, size, infectious wound complications and hemodynamic stability. Local expertise and availability of treatment devices need to be taken into account whenever choosing a treatment strategy. This review aimed to present current treatment options in terms of effectiveness, advantages and disadvantages in order to guide the clinician for his decision making. Additionally, we aimed to provide a treatment algorithm.
Assuntos
Fístula Anastomótica , Tratamento de Ferimentos com Pressão Negativa , Humanos , Estudos Retrospectivos , Fístula Anastomótica/cirurgia , Fístula Anastomótica/etiologia , Tratamento de Ferimentos com Pressão Negativa/efeitos adversos , Tratamento de Ferimentos com Pressão Negativa/métodos , Endoscopia/métodos , Esôfago , Stents/efeitos adversos , Resultado do TratamentoRESUMO
Postoperative non variceal upper gastrointestinal haemorrhage may occur early or late and affect a variable percentage of patients-up to about 2%. Most cases of intraluminal bleeding are an indication for urgent Esophagogastroduodenoscopy (EGD) and require endoscopic haemostatic treatment. In addition to the approach usually adopted in non-variceal upper haemorrhages, these cases may be burdened with difficulties in terms of anastomotic tissue, angled positions, and the risk of further complications. There is also extreme variability related to the type of surgery performed, in the context of oncological disease or bariatric surgery. At the same time, the world of haemostatic devices available in digestive endoscopy is increasing, meeting high efficacy rates and attempting to treat even the most complex cases. Our narrative review summarises the current evidence in terms of different approaches to endoscopic haemostasis in upper bleeding in altered anatomy after surgery, proposing an up-to-date guidance for endoscopic clinicians and at the same time, highlighting areas of future scientific research.
Assuntos
Procedimentos Cirúrgicos do Sistema Digestório , Hemostáticos , Trato Gastrointestinal Superior , Humanos , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/cirurgia , Endoscopia GastrointestinalRESUMO
BACKGROUND & AIMS: This cohort study compared colorectal cancer (CRC) incidence and mortality between people who participated in an Italian regional biennial fecal immunochemical test (FIT) screening program and people who did not. METHODS: The program started in 2005. The target population included over 1,000,000 people aged 50 to 69 years. The FIT was a one-sample OC-Sensor (Eiken Chemical Co, Tokyo, Japan) (cutoff, ≥20 µg hemoglobin/g feces). The average annual response rate to invitation was 51.4%. The records of people invited up to June 2016 were extracted from the screening data warehouse. Attenders were subjects who responded to the first 2 invitations or to the single invitation sent them before they became ineligible. Non-attenders were subjects who did not respond to any of these invitations. The records were linked with the regional CRC registry. People registered up to December 2016 were identified. Self-selection-adjusted incidence rate ratios (IRRs) and incidence-based CRC mortality rate ratios (MRRs) for attenders to non-attenders, with 95% confidence intervals (CIs), were calculated. RESULTS: The cohort generated 2,622,131 man-years and 2,887,845 woman-years at risk with 4490 and 3309 CRC cases, respectively. The cohort of attenders was associated with an IRR of 0.65 (95% CI, 0.61-0.69) for men, 0.75 (95% CI, 0.70-0.80) for women and 0.69 (95% CI, 0.66-0.72) for both sexes combined. The self-selection-adjusted IRR was 0.67 (95% CI, 0.62-0.72) for men and 0.79 (95% CI, 0.72-0.88) for women. The IRR for stage I, II, III, and IV CRC was 1.35 (95% CI, 1.20-1.50), 0.61 (95% CI, 0.53-0.69), 0.60 (95% CI, 0.53-0.68) and 0.28 (95% CI, 0.24-0.32) for men and 1.64 (95% CI, 1.43-1.89), 0.60 (95% CI, 0.52-0.69), 0.73 (95% CI, 0.63-0.85) and 0.35 (95% CI, 0.30-0.42) for women. The overall incidence-based CRC MRR was 0.32 (95% CI, 0.28-0.37) for men, 0.40 (95% CI, 0.34-0.47) for women and 0.35 (95% CI, 0.31-0.39) for both sexes combined. The adjusted MRR was 0.35 (95% CI, 0.29-0.41) for men and 0.46 (95% CI, 0.37-0.58) for women. CONCLUSIONS: Attendance to a FIT screening program is associated with a CRC incidence reduction of 33% among men and 21% among women, and a CRC mortality reduction of 65% and 54%, respectively.
Assuntos
Neoplasias Colorretais , Detecção Precoce de Câncer , Estudos de Coortes , Colonoscopia , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/epidemiologia , Fezes/química , Feminino , Hemoglobinas/análise , Humanos , Masculino , Programas de Rastreamento , Sangue OcultoRESUMO
BACKGROUND AND AIMS: Meta-analytic comparison of EUS-guided gallbladder drainage (EUS-GBD) versus percutaneous gallbladder drainage (PT-GBD) for acute cholecystitis (AC) brings the risk of spurious results if too few studies are included. Trial sequential analysis (TSA) can overcome this, providing information about its credibility. METHODS: Comparative studies between EUS-GBD, using lumen-apposing metal stents, and PT-GBD for AC until July 2021 were used for conventional meta-analysis and TSA, which allowed the use of monitoring boundaries and the estimation of the required information size (RIS) needed to prove credibility. RESULTS: Four studies accrued 535 patients. Technical success was in favor of PT-GBD (relative risk [RR], .967; P = .036), but TSA estimated that 1663 participants would be needed to avoid a Type I error (false positive). Clinical success was similar (RR, .965; P = .146), and TSA supported the absence of any demonstrable superiority of one therapy rather than a Type II error (false negative). EUS-GBD reduced overall adverse events (RR, .424; P < .001) and unplanned readmissions (RR, .215; P < .001), and TSA confirmed the avoidance of a Type I error, with early RIS achievement, providing necessary credibility. EUS-GBD had fewer reinterventions (RR, .244; P < .001), but a Type I error was not avoided, needing additional 97 patients to the accrued 535 to prove credibility. CONCLUSIONS: PT-GBD can provide superior technical success than EUS-GBD if a very large sample size is accrued, thus limiting the single-patient benefit. Clinical success is probably equivalent. EUS-GBD convincingly decreased overall adverse events and unplanned readmissions, whereas the need for reinterventions requires additional studies.
Assuntos
Colecistite Aguda , Colecistostomia , Colecistite Aguda/cirurgia , Drenagem/métodos , Endossonografia/métodos , Vesícula Biliar/diagnóstico por imagem , Vesícula Biliar/cirurgia , Humanos , StentsRESUMO
BACKGROUND AND AIMS: There is increasing interest in expanding the use of lumen-apposing metal stents (LAMSs) in patients with pancreatic fluid collections (PFCs). The aim of this study was to determine whether there is a hospital volume threshold for which patient outcomes could be optimized. METHODS: Data from a large multicenter series of patients with PFCs treated with LAMSs were retrieved. Rate of adverse events (AEs) was the primary outcome. Multivariable models with restricted cubic splines were used to identify a hospital volume threshold by plotting hospital volume against the log odds ratio (OR) of AE rate. Propensity score matching was applied to obtain 2 well-balanced groups according to hospital volume, and univariate/multivariate logistic regression analysis was performed to identify significant predictors of AEs. RESULTS: Overall, 516 patients were included. Increasing hospital volume was associated with a reduced AE rate (P = .03), and the likelihood of experiencing an AE declined as hospital volume increased up to 15 cases. After propensity score matching, 175 patients in the high-volume (>15 cases) and 132 in the low-volume hospital group were compared. Overall, 41 AEs were observed (13.3%), of which 14 (8%) and 27 (20.4%) occurred at high-volume and low-volume centers, respectively (P = .001). Severe and fatal events were observed more frequently in low-volume centers (6% vs 1.7% and 2.2% vs 0%, respectively; P = .05). In multivariate analysis, main pancreatic duct injury (OR, 2.62; 95% confidence interval [CI], 1.26-4.67; P = .02), presence of abnormal vessels (OR, 2.93; 95% CI, 1.41-5.02; P = .006), and institutional experience (OR, 2.95; 95% CI, 1.48-5.90; P = .002) were significant predictors of AEs. CONCLUSIONS: With 15 procedures representing the minimum number of cases associated with the lowest risk for postprocedural AEs, hospital volume is associated with improved outcomes. (Clinical trial registration number: NCT03903523.).